1
2
3-4
5-6
7
8
8-9
9
9
Product Image
Table of Contents
What is a Programmable
Room Thermostat?
Installation Procedure
Mode Select
Pairing the SmartHub
Pairing the SmartStat
What is a Mesh Network?
Approach Sensor
34-35
36
37
38
38
39
LCD Display
Setting the Switching Times
Timer Override
Optional Features
Optional Features Table
Time Clock Mode Wiring Diagram
Mode 2 - Time Clock
LCD Display
Temperature Display
Setting the Clock
Setting the Comfort Levels
Setting the Temperature
Temperature Hold
Locking/Unlocking the neoStat
3410
Mode 1 - Thermostat
11-12
13
14
15-16
17
18
19
Frost Protection
Power ON/OFF
Holiday Programming
Optional Features
Re-calibrating the Thermostat
Error Codes
Floor Temp Sensor Probe Type
Diagrams
Factory Reset
20
21
22
23-26
27
27
28
29-32
33
SmartStat

3
What is a Programmable Room Thermostat?
A programmable room thermostat is both a programmer and a room thermostat.
A programmer allows you to set “On”and “O” periods to suit your own lifestyle.
A room thermostat works by sensing the air temperature, switching on the heating
when the air temperature falls below the thermostat setting, and switching it o once
this set temperature has been reached.
So a programmable room thermostat lets you choose what times you want the heating
to be on, and what temperature it should reach while it is on. It will allow you to select
dierent temperatures in your home at dierent times of the day (and days of the week)
to meet your particular needs and preferences.
Setting a programmable room thermostat to a higher temperature will not make the
room heat up any faster. How quickly the room heats up depends on the design and
size of the heating system.
Similarly reducing the temperature setting does not aect how quickly the room cools
down. Setting a programmable room thermostat to a lower temperature will result in
the room being controlled at a lower temperature, and saves energy.
Smart Series

4
The way to set and use your programmable room thermostat is to nd the lowest
temperature settings that you are comfortable with at the dierent times you have
chosen, and then leave it alone to do its job.
The best way to do this is to set the room thermostat to a low temperature
– say 18°C , and then turn it up by 1°C each day until you are comfortable with the
temperature. You won’t have to adjust the thermostat further. Any adjustment above
this setting will waste energy and cost you more money.
You are able to temporarily adjust the heating program by overriding or using the
temperature hold feature. These features are explained further on pages 17 and 18
of this manual.
Programmable room thermostats need a free ow of air to sense the temperature,
so they must not be covered by curtains or blocked by furniture. Nearby electric
res, televisions, wall or table lamps may also prevent the thermostat from working
properly.
SmartStat

5
Installation Procedure
The SmartStat is designed to be ush mounted and requires a back box of 35mm
(minimum depth) to be sunk into the wall prior to installation.
Step 1
Using a small screwdriver, slightly loosen the screw from the bottom face of
the thermostat. Then carefully separate the front half from the back plate.
Step 2
Place the thermostat front somewhere safe.
Terminate the thermostat as shown in the diagrams on pages 28-31 of this booklet.
Note: For time clock wiring connections, terminate as shown on page 38.
Step 3
Screw the thermostat back plate securely into the back box.
Step 4
Clip the front of the thermostat onto the back plate, securing it in place with the
retaining screw.
Do
Mount the thermostat at eye level.
Read the instructions fully so you get the best from our product.
Don’t
Do not install near to a direct heat source as this will aect functionality.
Do not push hard on the LCD screen as this may cause irreparable damage.
Smart Series

6
1 2
3 4
SmartStat

7
SmartStat can either be used as a thermostat or a time clock.
Thermostat mode is the default setting.
To change between thermostat or time clock modes, follow these steps.
• Use the Left / Right keys to scroll to ...........................................................................
• Press and hold the Tick button for 3 seconds ...............................................................
• SETUP will be highlighted, now press and hold the tick key for 10 seconds.....
• Use the Left / Right keys to scroll between modes .....................................................
Mode 1 = Thermostat
Mode 2 = Time Clock
• Press the Tick key to conrm selection............................................................................
The SmartStat will revert to the main display screen for the selected mode.
For time clock mode instructions, rst pair the time clock with the SmartHub as
explained on page 8, then turn to page 33.
Mode Select
Smart Series

8
The next step is to join the SmartStat to the Hub, we recommend joining the
thermostat located nearest to the SmartHub rst.
To add a SmartStat, follow these steps;
• In the app, select ADD ZONE, enter a preset or custom title, thenpress NEXT.
• You now have two minutes to join the thermostat to the Hub.
• On the SmartStat, use the Left / Right keys to select , press and hold Tick............
• SETUP will be highlighted, now press the tick key once .....................................................
• Feature 01 is displayed on screen.
Pairing the SmartStat
Pairing the SmartHub
To pair the SmartHub with the Polypipe Smart App, follow these steps.
• Connect the Hub to your router with the Ethernet cable provided.
• Connect the power supply to the neoHub.
• The router will automatically assign an IP address to the Hub, the Link LED
will light up RED once the SmartHub has connected to your network.
• Once connected to the cloudserver, the Link LED will turn GREEN.
• Connect your smartphone or tablet device to the same WiFi network as your router.
• Download the FREE Polypipe SmartApp from the Apple App Store or Google Play Store
and register an account.
• Once you have registered your account, press Sign In, then press Add Location.
• Pressthe connect button on the SmartHub to add the location to your account.
• When successfully connected, enter a title for the location (e.g. Home).
SmartStat

9
What is a Mesh Network
Approach Sensor
SmartStat works using a mesh network, meaning SmartStats have the ability
to send & receive signals via other thermostats on the network. This signal is relayed
from one thermostat to another until it reaches its destination. This communication
method extends the communication range whilst oering increased network stability
when compared with standard RF thermostats.
The Mesh symbol is shown when the device is communicating with the Hub, if the
mesh symbol disappears this indicates connection to the SmartHub has been lost.
The SmartStat uses proximity to detect when you are about to use the touch
keys. As you approach the thermostat, the touch keys and backlight will light up.
This can be useful if you need to adjust the set temp or timer in a dark room.
• Press the Tick key once again to pair the thermostat to the Hub....................
• The MESH symbol appears ashing on the display.
• When the SmartStat successfully connects to the Hub the
MESH symbol will be permanently displayed.
• Press ADD ANOTHER for addtional zones or press FINISH to complete setup.
Please note, you only have to pair the hub to your account once.
To pair any additional Smart Stat, select ZONES, edit, then ADD ZONE.
Smart Series

10
Mode 1 - Thermostat
SmartStat

11
5
10
12
13
14
15
16
9
6
1 2 3 4
8
7
11
Smart Series

12
1. Mesh Symbol- Displayed when connected to the SmartHub.
2. Day Indicator - Displays the day of the week.
3. Frost Protection – Displayed whenfrost protection is enabled.
4. Flame Symbol – Displayed whenthe thermostat iscalling for heat and ashes when
optimum start is active.
5. Holiday – Displayed when the thermostat is in holiday mode.
6. FloorLimit Symbol –Displayed when the oor probe has reached the oor
temperature limit congured in the setup menu.
7. Floor/Room Temp - Indicates the displayed sensor mode.
8. Set - Displayed when changes are being made to the current setpoint.
9. Program Indicator - Displayed during programming (6 level mode) to show which
level is being altered.
10. Program Indicator - Displayed during programming (4 level mode) to show which
level is being altered.
11. Main Menu- Displays whichoption is currently selected.
12. Keypad Lock Indicator – Displayed whenthe keypad is locked.
13. Temperature – Displays the current sensor temperature.
14. Temperature Format - Degrees Celsius or Fahrenheit.
15. Hold Left - Displayed when a temperature hold isactive, the remaining time
will be shown.
16. Time/Day/Month/Year- Displays whensetting the Clock/Calendar or a
Holiday Period.
LCD Display
SmartStat

13
The SmartStat can be congured for dierent sensor options such as built in air
sensor, oor sensor or both. The display will clearly indicate which sensor is being used
by showing either“Room Temp”or “Floor Temp”before the actual temperature value.
When the SmartStat is set to use both the air & the oor sensor, the room temperature
will be displayed by default.
To view the current oor temperature, press and hold the Left and Right
arrow keys for 5 seconds, the oor temperature will then be displayed....................
Temperature Display
Room Temperature Floor Temperature
Smart Series

14
Setting the Clock
To set the clock, follow these steps.
• Use the Left / Right keys to scroll to ..........................................................................
• Press and hold Tick to turn o the display ...................................................................
• Use the right arrow key to select CLOCK .......................................................................
• Press Tick to conrm selection ..........................................................................................
• Use Up / Down keys to set the year ................................................................................
• Press Tick to conrm selection ..........................................................................................
• Repeat the steps to set the Month, Date & Time ........................................................
• Press Tick to conrm the new clock settings ...............................................................
• Use the down arrow to scroll to ..................................................................................
• Press Tick to turn the display on .......................................................................................
Day
Time
SmartStat

15
Comfort Levels Explained
The SmartStat oers three program mode options; Weekday/Weekend
programming, 7 Day programming and 24 Hour programming. There is also the option to
use the thermostat as a Non-Programmable thermostat.
When thermostats are connected to the mesh network, the program mode for
the system is congured by using the Polypipe SmartApp.
The thermostat is supplied with comfort levels already programmed, but these can be
changed easily. The default times and temperature settings are;
07:00 - 21°C (Wake) 09:00 - 16°C (Leave) 16:00 - 21°C (Return) 22:00 - 16°C (Sleep)
If you only want to use 2 levels, you should program the unused levels to --:--
For Weekday/Weekend programming, the four comfort levels are the same for Mon-Fri, but can
be dierent for Sat-Sun. For 7 Day programming each day of the week can have four dierent
comfort levels. In 24 Hour mode all days are programmed with the same comfort levels.
• To program the comfort levels, use the Left / Right keys to scroll to EDIT .............
• Press Tick to conrm selection ......................................................................................................
• Use the Left / Right keys to select day / period of week (the selection will ash).
• Press Tick to conrm selection ......................................................................................................
• WAKE will now ash and the current time and temperature setting will be shown.
• Press Tick to alter WAKE settings ...................................................................................................
Smart Series

16
• Use the Up / Down keys to set the hours .............................................................
• Press Tick to conrm ............................................................................................................
• Use the Up / Down keys to set the minutes ........................................................
• Press Tick to conrm ............................................................................................................
• Use the Up / Down keys to set the temperature ...............................................
• Press Tick to conrm the settings ...................................................................................
• Press the right arrow key ...................................................................................................
• LEAVE will now ash and the current settings will be displayed.
• Press Tick to alter LEAVE settings ....................................................................................
• Repeat these steps to set all comfort levels.
• For any unused periods set time to --:--
• Use the Left / Right keys to scroll to DONE and press Tick .....................
SmartStat

17
Temperature Control
The Up / Down keys allow you to adjust the set temperature ..................................
When you press either key, you will see the word SET and the desired
temperature value. Use the Up / Down keys to adjust the SET value .....................
Press Tick to conrm settings and return to the main display ...........................................
Note: This new temperature is maintained only until the next programmed comfort level.
At this time, the thermostat will revert back to the programmed levels.
Set Icon
Set Temperature
Smart Series

18
Temperature Hold
To cancel a temperature Hold, withhold selected on the main menu,
pressthe tick key and then press tick again while Cancel ishighlighted.
Hold Time Remaining
Hold Left Indicator
The temperature hold function allows you to manually override the current operating
program and set a dierent temperature for a desired period.
• Use the Left / Right keys to scroll to HOLD.................................................................
• Press Tick to conrm selection ................................................................................................
• Use the Up / Down keys to set the desired Hold period ......................................
• Press Tick to conrm selection ................................................................................................
• Use the Up / Down keys to set the desired Hold temperature ..........................
• Press Tick to conrm selection ................................................................................................
You will see the HOLD LEFT indication is displayed on screen.
The time will countdown the set duration and then revert to the normal program.
SmartStat

19
Locking the Display
The SmartStat has a keypad lock facility. To activate the lock follow these steps.
• Use the‘Left/Right’ keys to scroll to‘HOLD’ & press for 10 seconds ........
The display will show 0000. At this point enter a four digit pin number.
• Use the Up / Down keys to enter the rst two digits ........................................
• Press to conrm .................................................................................................................
• Use the Up / Down keys to enter the second two digits .................................
• Press to conrm .................................................................................................................
The display will return to the main screen and display the keypad lock indicator ......
Note: The keypad lock indicator is only displayed when the lock is active.
To unlock the SmartStat press Tick once. The display will show 00:00 and you will
need to enter the four digit pin number you set previously.
• Use the Up / Down and keys to enter the rst two digits...........................
• Use the Up / Down and keys to enter the second two digits ...................
The display will unlock and return to the main screen.
Unlocking the Display
Smart Series
Table of contents
Other Polypipe Thermostat manuals
Popular Thermostat manuals by other brands

Danfoss
Danfoss DEVIreg 330 installation guide

Alien green
Alien green Mostat Instructions for installation

Honeywell
Honeywell T841A installation instructions

Honeywell
Honeywell TB7100A1000 - MultiPro Commercial Thermostat installation instructions

NEXGEN
NEXGEN NXG08 user manual

Honeywell
Honeywell RTH110B Instalación y guía para el usuario