Porta Source IG3200W User manual

Operator’s Manual
Porta Source
TM
3200 Watt
Inverter Generator
P/N: 20795
ECN: 10550
REV3: 10/01/14
© 2014 Ardisam, Inc.
All Rights Reserved
Get parts online at
www.PortaSourceGenerators.com
SN
READ OM ICON R1
CAUTION ICON R1
Product #: IG3200W
20795-0001R1

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
2
INTRODUCTION
Congratulations on your investment in quality. Thank you for purchasing an IG3200W Inverter Generator from Porta Source. We
have worked to ensure that the IG3200W meets the highest standards for usability and durability. With proper care, your generator
will provide many years of service.
Please read this entire manual before use. Porta Source reserves the right to change, alter or improve the product and
this document at any time without prior notice.
CONTENTS
Registration ....................................................................................................................................................................................................................................2
Warnings & Safety Precautions............................................................................................................................................................................................ 3-4
Engine Safety Precautions..................................................................................................................................................................................................... 5-7
Safety Decals..............................................................................................................................................................................................................................8-9
Features & Controls............................................................................................................................................................................................................. 10-11
Specications...............................................................................................................................................................................................................................11
Pre-Operation Check.......................................................................................................................................................................................................... 12-13
Operation............................................................................................................................................................................................................................... 14-15
Maintenance ......................................................................................................................................................................................................................... 16-18
Transport & Storage...................................................................................................................................................................................................................19
Troubleshooting & Repair .......................................................................................................................................................................................................20
Illustrated Parts Breakdown.............................................................................................................................................................................................21-25
Electrical Wire Diagram ............................................................................................................................................................................................................26
Notes........................................................................................................................................................................................................................................ 27-28
Warranty ................................................................................................................................................................................................................................. 29-31
Federal Emissions Information
Porta Source warrants to the retail purchaser, that this small, o-road engine was designed, built and equipped to conform at the
time of initial sale to all applicable regulations of the U.S. Environmental Protection Agency (EPA).
Registration and Service
Record the model number and serial number in the space provided for easy
reference when ordering parts or requesting technical support. Excluding
emissions-related warranty items, the warranty is valid only if the completed
registration is received by Ardisam within 30 days of purchase. (SEE WARRANTY
SECTION FOR MORE INFORMATION.) You can register your warranty online by
visiting www.PortaSourceGenerators.com, or by mailing it to: Ardisam, 1160 Eighth
Avenue, Cumberland, WI 54829. For additional information, call Porta Source
customer service at (800) 345-6007 Mondays through Fridays from 8 a.m. to 5 p.m.
CST.
Read and keep this manual for future reference. This manual contains important information on SAFETY, ASSEMBLY, OPERATION,
AND MAINTENANCE. The owner must be certain that all the product information is included with the unit. This information
includes the MANUAL, the REPLACEMENT PARTS and the WARRANTIES. This information must be included to make sure state laws
and other laws are followed. This manual should remain with the product even if it is resold.
OWNERSHIP RECORDS
Owner’s Name:
Owner’s Address:
City: State/Province: Zip Code/Postal Code:
Model Number: Serial Number:
Date of Purchase:
Notes:
20795-0002R1
SERIAL NUMBER
DATA PLATE

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 3
Operator’s Manual
3200 Watt Inverter Generator
WARNINGS & SAFETY PRECAUTIONS
Owner’s Responsibility
Accurate assembly and safe and eective use of the machine is
the owner’s responsibility.
• Read and follow all safety instructions.
• Carefully follow the pre-operation check instructions.
• Maintain the machine according to directions and
schedule included in this Porta Source Operator’s
Manual.
• Ensure that anyone who uses the machine is familiar
with all controls and safety precautions.
Special Messages
Your manual contains special messages to bring attention to
potential safety concerns, machine damage as well as helpful
operating and servicing information. Please read all the
information carefully to avoid injury and machine damage.
NOTE: General information is given throughout the
manual that may help the operator in the
operation or service of the machine.
THIS SYMBOL POINTS OUT IMPORTANT
SAFETY INSTRUCTIONS WHICH IF NOT
FOLLOWED COULD ENDANGER YOUR
PERSONAL SAFETY OR THE SAFETY OF
YOUR EQUIPMENT. READ AND FOLLOW ALL
INSTRUCTIONS IN THIS MANUAL BEFORE
ATTEMPTING TO OPERATE THIS EQUIPMENT.
Before Operating Engine:
Please read this section carefully. Read entire operating and
maintenance instructions for this product. Failure to follow
instructions could result in serious injury or death. Operate the
machine according to the safety instructions outlined here and
inserted throughout the text. Anyone who uses this machine
must read the instructions and be familiar with the controls.
Intended Use /
Foreseeable Misuse
IMPORTANT: This is a motorized inverter generator that
processes DC energy into smooth AC power. It is a pedestrian-
use product, with a gasoline-fueled internal combustion
engine to generate usable power. It shall not be used for any
other purpose.
WARNING
WARNING INDICATES A HAZARD WHICH, IF NOT
AVOIDED, COULD RESULT IN DEATH OR SERIOUS
INJURY AND/OR PROPERTY DAMAGE.
CAUTION
CAUTION INDICATES YOU CAN BE HURT OR
YOUR EQUIPMENT DAMAGED IF THE SAFETY
INSTRUCTIONS THAT FOLLOW THIS SIGNAL
WORD ARE NOT OBEYED.
IMPORTANT
INDICATES HELPFUL INFORMATION FOR PROPER
ASSEMBLY, OPERATION, OR MAINTENANCE OF
YOUR EQUIPMENT.
WARNING
CALIFORNIA PROPOSITION 65 WARNING
ENGINE EXHAUST FROM THIS PRODUCT
CONTAINS CHEMICALS KNOWN TO THE STATE OF
CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS,
OR OTHER REPRODUCTIVE HARM.
WARNING
YOU MUST READ, UNDERSTAND AND COMPLY
WITHALLSAFETYANDOPERATINGINSTRUCTIONS
IN THIS MANUAL BEFORE ATTEMPTING TO SETUP
AND OPERATE YOUR MACHINE.
FAILURE TO COMPLY WITH ALL SAFETY AND
OPERATING INSTRUCTIONS CAN RESULT IN LOSS
OF MACHINE CONTROL, SERIOUS PERSONAL
INJURY TO YOU AND/OR BYSTANDERS, AND RISK
OF EQUIPMENT AND PROPERTY DAMAGE. THE
TRIANGLE IN THE TEXT SIGNIFIES IMPORTANT
CAUTIONS OR WARNINGS WHICH MUST BE
FOLLOWED.

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
4
GENERAL SAFETY RULES
Read, understand, and follow all instructions on the machine
and in the manual(s). Be thoroughly familiar with the controls
and the proper use of the machine before starting.
• Use this equipment for its intended purpose only.
• Familiarize yourself with all of the safety and
operating decals on this equipment and on any of its
attachments or accessories.
• Never operate in an enclosed area, in a vehicle or
indoors even if doors and windows are open.
• Only allow responsible individuals who are familiar
with the instructions to operate the machine. Do
not allow children to operate this machine. Do not
allow adults to operate the machine without proper
instruction.
• Operate generator only on level surfaces and where it
will not be exposed to excessive moisture, dirt, dust or
corrosive vapors.
• Keep hands, feet, clothing, etc., away from drive belts,
fans and other moving parts. Never remove any fan
guard or shield while the unit is operating.
• Do not operate the machine without proper guards or
other safety protective devices in place.
• See manufacturer’s instructions for proper operation
and installation of accessories. Only use accessories
approved by the manufacturer.
• Do not operate or work on this product when
fatigued or under the inuence of alcohol, drugs or
other medication which can cause drowsiness or
aect your ability to operate this machine safely.
• Do NOT operate generator in rain or snow.
• If the equipment should start to vibrate abnormally,
stop the engine (motor). Turn the engine key switch
to the “STOP” position. Check immediately for cause.
Vibration is generally a warning of trouble. If the
noise or vibrations of the machine increase, stop
immediately and perform an inspection.
• Never leave the machine unattended when the
engine is running. Turn the engine key switch to the
“STOP” position. Regularly inspect the machine. Make
sure parts are not damaged or loose.
• Certain parts of the generator get extremely hot
during operation. Avoid severe burns, keep clear of
the generator until it has cooled.
• Do not alter the construction of the generator or change
controls which might create an unsafe operating
condition.
• Keep all screws, nuts and bolts tight.
• Do not transport the machine from one place to
another with the engine running.
• Never use the generator or any of its parts as a step.
Stepping on the unit can stress and break parts and
may result in dangerous operating conditions from
leaking exhaust gases, fuel leakage, oil leakage, etc.
• When moving the packaged machine, always do so
with a partner.
• Check local regulations for any restrictions on the use
of this machine.
Product-Specic Safety Rules
• The generator produces dangerously high voltage
when in operation. Avoid contact with bare wires,
terminals, connections, etc., while the unit is running,
even on equipment connected to the generator.
Ensure all appropriate covers, guards and barriers are
in place before operating the generator.
• Never handle any kind of electrical cord or device
while standing in water, while barefoot or while hands
or feet are wet. DANGEROUS electrical shock may
result.
• The generator must be earth grounded in accordance
with all relevant electrical codes and standards before
operating. A 10 gauge copper wire should be used
to connect the ground terminal of the generator to
a grounding rod. A wire too thin may not provide
sucient electrical current carrying capacity to be an
adequate ground path.
• Use a ground fault circuit interrupter in any damp or
highly conductive area (such as metal decking or steel
work).
• Do not use worn, bare, frayed or otherwise damaged
electrical cord sets with the generator.
• In case of accident caused by electric shock,
immediately shut down the source of electrical power.
If this is not possible, attempt to free the victim
from the live conductor. AVOID direct contact with
the victim. Use a non-conducting implement, such
as a rope or board, to free the victim from the live
conductor. If the victim is unconscious, apply rst aid
and get immediate medical help.

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 5
Operator’s Manual
3200 Watt Inverter Generator
ENGINE SAFETY PRECAUTIONS
Warning Carbon Monoxide Poisoning
Engines give o carbon monoxide, an odorless, colorless,
poisonous gas. Carbon monoxide may be present even if you
do not smell or see any engine exhaust. Breathing carbon
monoxide can cause nausea, fainting or death, in addition
to drowsiness, dizziness and confusion. If you experience
any of these symptoms, seek fresh air and medical attention
immediately.
If your product comes with a separate engine manual, be sure
to read and follow all safety and warning precautions outlined
there, in addition to any in this manual.
Preventing Carbon Monoxide Poisoning
• Always start and run engine outdoors. Do not start
or run engine in an enclosed area, even if doors or
windows are open.
• Never try to ventilate engine exhaust indoors. Carbon
monoxide can reach dangerous levels very quickly.
• Never run engine outdoors where exhaust fumes may
be pulled into a building.
• Never run engine outdoors in a poorly ventilated area
where the exhaust fumes may be trapped and not
easily taken away. (Examples include: in a large hole
or areas where hills surround your working area.)
• Never run engine in an enclosed or partially enclosed
area. (Examples include: buildings that are enclosed
on one or more sides, under tents, car ports or
basements.)
• Always run the engine with the exhaust and muer
pointed in the direction away from the operator.
• Never point the exhaust muer towards anyone.
People should always be many feet away from the
operation of the engine and its attachments.
• Do not change the engine governor settings or over-
speed the engine.
WARNING
ENGINES GIVE OFF CARBON MONOXIDE, AN
ODORLESS, COLORLESS, POISONOUS GAS.
CARBON MONOXIDE MAY BE PRESENT EVEN IF
YOU DO NOTSMELLORSEEANYENGINEEXHAUST.
BREATHING CARBON MONOXIDE CAN CAUSE
NAUSEA, FAINTING OR DEATH, IN ADDITION TO
DROWSINESS, DIZZINESS AND CONFUSION.
IF YOU EXPERIENCE ANY OF THESE SYMPTOMS,
SEEK FRESH AIR AND MEDICAL ATTENTION
IMMEDIATELY.
20795-0003R1
GROUND GENERATOR WITH THE APPROPRIATE
AMOUNT OF COPPER FOR CURRENT CAPACITY.
COPPER WIRE
DIAMETER
0.005 IN/AMP
GENERATOR
GROUND SCREW
WARNING
NEVER USE INSIDE
A HOME OR GARAGE
ONLY USE OUTDOORS,
AWAY FROM DOORS
AND WINDOWS
DO NOT USE GENERATOR INDOORS.
CARBON MONOXIDE POISONING CAN CAUSE DEATH.
20795-0004R1

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
6
• Always wipe up excess (spilled) fuel from engine
before starting. Clean up spilled fuel immediately.
If fuel is spilled, do not start the engine but move
product and fuel container from area. Clean up spilled
fuel and allow to evaporate and dry after wiping and
before starting.
• Allow fuel fumes/vapors to escape from the area
before starting engine.
• Test the fuel cap for proper installation before starting
and using engine.
• Always run the engine with fuel cap properly installed
on the engine.
• Never smoke while relling or draining engine fuel
tank.
• Do not store engine with fuel in fuel tank indoors. Fuel
and fuel vapors are highly explosive.
• Never pour fuel from engine fuel tank.
• Never siphon fuel by mouth to drain fuel tank.
• Always have an adult ll the fuel tank and never allow
children to ll the engine.
• Never allow an adult or anyone under the inuence of
drugs or alcohol to ll engine.
When storing gasoline or equipment with fuel in the tank,
store away from furnaces, stoves, water heaters or other
appliances that have a pilot light or other ignition source
because they can ignite gasoline vapors.
Burns and Fires
The muer, muer guard and other parts of the engine
become extremely hot during the operation of the engine.
These parts remain extremely hot after the engine has
stopped.
Prevention of Burns and Fires
• Never remove the muer guard from the engine.
• Never touch the muer guard because it is extremely
hot and will cause severe burns.
• Never touch parts of the engine that become hot after
operation.
• Always keep materials and debris away from muer
guard and other hot parts of the engine to avoid res.
Gasoline Fires and Handling Fuel Safely
Use extra care in handling gasoline and other fuels. They are
ammable and vapors are explosive.
• When storing extra fuel be sure that it is in an
appropriate container and away from any re hazards.
• Prevent re and explosion caused by static electric
discharge. Use only nonmetal, portable fuel
containers approved by the Underwriter’s Laboratory
(U.L.) or the American Society for Testing & Materials
(ASTM).
• Always ll fuel tank outside in a well ventilated area.
Never ll your fuel tank with fuel indoors. (Examples
include: basement, garage, barn, shed, house, porch,
etc.) Never ll tank near appliances with pilot lights,
heaters, or other ignition sources. If the fuel has to be
drained, this should be done outdoors. The drained
fuel should be stored in a container specically
designed for fuel storage or it should be disposed of
carefully.
• Never remove the fuel cap or add fuel with the engine
running. Stop engine and allow to cool before lling.
• Never drain fuel from engine in an enclosed area.
WARNING
HOT GASES ARE A NORMAL BYPRODUCT OF A
FUNCTIONING INTERNAL COMBUSTION ENGINE.
FOLLOW ALL SAFETY INSTRUCTIONSTO PREVENT
BURNS AND FIRES.
NEVER ALTER OR MODIFY THE ENGINE FROM
THE FACTORY. SERIOUS INJURY OR DEATH MAY
OCCUR IF ENGINE IS MODIFIED OR ALTERED.
WHEN WORKING ON OR REPLACING PARTS FOR
THE ENGINE OR PRODUCT, YOU MUST ALWAYS
TURN THE ENGINE KEY SWITCH TO THE STOP
POSITION.
CAUTION
DO NOT REFILL TANK WHILE ENGINE IS RUNNING
OR HOT. ALWAYS CLOSE FUEL VALVE BEFORE
REFUELING.
BE CAREFUL NOT TO ALLOW DUST, DIRT, WATER
OR OTHER FOREIGN OBJECTS INTO FUEL.
DO NOT FILL ABOVE THE TOP OF THE FUEL
STRAINER OR IT MAY OVERFLOW WHEN THE FUEL
EXPANDS.
KEEP AWAY FROM OPEN FLAMES.

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 7
Operator’s Manual
3200 Watt Inverter Generator
Children and bystanders
Tragic accidents can occur if the operator is not alert to the
presence of children and/or bystanders. Never assume that
others will remain where you last saw them.
• Keep the area of operation clear of all persons,
especially small children and pets. Keep children
under the watchful care of a responsible adult.
• Never allow children to operate the machine.
Service
• Always stop the engine whenever you leave the
equipment, before cleaning, repairing or inspecting
the unit. Engine should be turned o and cool. Never
make adjustments or repairs with the engine (motor)
running. Turn the engine key switch to the “STOP”
position to prevent accidental starting.
• Always wear eye protection when you make
adjustments or repairs. Keep all nuts and bolts tight
and keep equipment in good condition.
• Never tamper with safety devices. Check their proper
operation regularly.
• When servicing or repairing the machine, do not tip the
machine over or up unless specically instructed to do
so in this manual. Service and repair procedures can be
done with the machine in an upright position. Some
procedures will be easier if the machine is lifted on a
raised platform or working surface.
• To reduce re hazard, keep machine free of grass,
leaves or other debris build-up. Clean up oil or fuel
spillage. Allow machine to cool before storing.
• Clean and replace safety and instruction decals as
necessary.
• To guard against engine over-heating, always have
engine lters mounted and clean.
• Inspect machine before storage. When not in use, turn
the engine key switch to the“STOP” position. Store
indoors in a dry, securely locked location inaccessible
to children.
• Use only original equipment parts from Porta Source
including all nuts and bolts.
• Avoid connecting the generator to commercial power
outlets.
• Avoid connecting the generator in parallel with any
other generator.

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
8
SAFETY DECALS
This IG3200W Inverter Generator has been designed and manufactured to provide you with the safety and reliability you would
expect from an industry leader in powered chore equipment manufacturing.
Reading this manual and the safety instructions it contains will provide you with the necessary basic knowledge to operate
this equipment safely and eectively. We have placed a safety decal on the generator to remind you of some of this important
information while you are operating the unit.
These important safety decals are illustrated below, and are shown here to help familiarize you with the location and content of
the safety messages you will see as you perform normal operations. Please review these decals now, and if you have any questions
regarding its meaning or how to comply with these instructions, reread the complete safety instruction text in this manual. For
additional questions European customers may contact their local dealer and US customers must call Porta Source customer
service.
Should a decal become unreadable because of being worn, faded, or otherwise damaged during the use of your IG3200W, please
use the part number information provided to order a replacement label. European customers can order from their local authorized
dealer and US customers can order by calling Porta Source customer service. These decals are easily applied, and will act as a
constant visual reminder to you, and others who may use the equipment, to follow the safety instructions necessary for safe,
eective operation of your inverter generator.
(Part # 20996)
DECAL SERIAL NUMBER IG3200W
Product Name Plate with Serial Number
(Part # 20926)
DECAL STARTING INSTRUCTIONS IG3200
Starting Instructions and Engine Oil Type

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 9
Operator’s Manual
3200 Watt Inverter Generator
16061
RUN CHOKE
MARCHE ÉTRANGLÉ
(Part # 20927)
DECAL PICTOGRAMS HOT SURF
CARBON MONO 2M
Hot Surface, Carbon
Monoxide, Keep Distance
(Part # 16063)
TAG HANG NO OIL
GENERATOR
Add Specied
Engine Oil
(Part #20929)
DECAL WARNING
FIRE HAZARD NO E85
IG3200W
Engine Fuel is Flammable (Part # 20928)
DECAL FUEL SHUTOFF
IG3200W
Fuel Valve ON and O
(Part # 11708)
DECAL SPARK PLUG
ACCESS IG800W 43 X 51
Spark Plug Location
(Part # 16061)
DECAL CHOKE
GENERATOR 50 X 18
Run and Choke
SAFETY DECALS CONT.

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
10
FEATURES & CONTROLS
ENGINE CONTROL
HOUR METER
0000.20
ON
OFF
I
O
STOP
RUN
START
ELECTRIC
START
ECONOMY MODE
STATUS
OUTPUT
OVERLOAD
OIL ALERT
120V/20A 120V/30A
AC
OFF
ON
PUSH
DC
OFF
ON
PUSH
12V/5A
USB
5V/1000mA
2 - 120V/20A A/C OUTLETS
120V/30A A/C
LOCKING OUTLET
USB CHARGE PORT
12V/5A DC OUTLET
FUEL TANK CAP
FUEL STRAINER
AIR FILTER
GENERATOR STATUS DISPLAY
12 VOLT BATTERY
CARRY HANDLE
LOCKABLE
TRANSPORTATION
WHEELS
A/C CIRCUIT
PROTECTION
HOUR METER
ECONOMY
MODE
SWITCH
ELECTRIC
START
KEY SLOT
OIL FILTER ASSY
DC CIRCUIT
PROTECTION
RECOIL STARTER
FUEL SHUTOFF VALVE
20795-0005R1
EXHAUST
MUFFLER
GROUNDING SCREW

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 11
Operator’s Manual
3200 Watt Inverter Generator
Ac Voltage 60Hz -120V
Max Output 3200 watts
Rated Output 2800 watts
Dc Output 12V / 6A
Engine Displacement 149.5cc
Engine Type 4-cycle
Noise Level (@7M) 60 dB
Fuel Tank Capacity 1.66 gallons (6.3 liters)
Recommended Fuel Type Minimum 87 octane gasoline
NOTE: If using an ethanol
blended fuel, a fuel
stabilizer, mixed
to manufacturer
specications, is
recommended.
Run Time (100% Load) 3.8 hours
Oil Tank Capacity 30.4 ounces (0.9 liter)
Oil Type 10W-30 (SJ, SL or better)
Spark Plug A7RTC (TORCH) (NGK CR7HSA)
Spark Plug Gap 0.6 - 0.7 mm
Weight Of Unit 83.78 lb
Unit Size L X W X H
(Inches)
24.2 x 13.43 x 19.92
SPECIFICATIONS
Oil Warning System
When the oil level reaches a low level, the engine will stop
automatically. In order to restart the engine, the oil must be
relled.
NOTE:
It is important to check the oil level every 20 hours of
run time as indicated on the hour meter.
Engine Key Switch: SEE FIGURE 1
The engine key switch must be in the“RUN” position to start
and run the generator. Turn the engine switch to the “STOP”
position to stop the generator.
NOTE:
It is recommended to keep the engine switch in the
STOP position while the generator is not in use.
Economy Control Switch: SEE FIGURE 1
When the Economy Mode control switch is in the“ON”
position, the economy control unit controls the engine speed
according to the connected load. The results are better fuel
usage and lower noise levels.
NOTE: When starting the generator, and while plugging
in and starting connected devices, make sure the
economy control switch is in the OFF position.
When all units are running smoothly, push the
economy switch to the ON position .
DC Circuit Protector
The DC circuit protector turns o automatically when the load
exceeds the generator’s rated output. SEE FIGURE 1
NOTE: If generator turns o due to access load, reduce
the load to within specic generator rated output
levels.
FIGURE 2
FIGURE 1
AC/DC PROTECTOR
ECONONY MODE
20795-0006R1
ON
OFF
STOP
RUN
START
ELECTRIC START
OFF
ON
PUSH
Fuel Valve
The fuel valve must be in the ON position to run the generator.
When the generator is not in use, turn the fuel valve to the
OFF position. SEE FIGURE 2
20795-0007R1
ON
OFF

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
12
Filling Fuel Tank:
1. Make sure the generator is not running and is completely
cool before relling the fuel tank.
2. Move to a well ventilated area, outdoors, away from
ames and sparks.
3. Clean debris from area around the fuel cap.
4. Loosen fuel cap slowly. Prevent the cap from coming in
contact with dirt or debris.
5. Carefully add fuel without spilling.
6. Do not ll fuel tank completely full, allow space for fuel to
expand.
7. Immediately replace fuel cap and tighten. Wipe o spilled
fuel and allow to dry before starting engine.
Check Engine Oil: SEE FIGURE 3.
Make sure the engine oil is at the upper level of the oil ll hole.
Add oil as necessary.
To add/check the engine oil:
1. Be sure the generator is located on a level surface before
checking or relling the oil.
2. Remove the side panel on the engine recoil side of the
generator. Two screws must be removed, one from each
upper corner of the side panel.
NOTE:
Included in
the
box is a Phillips head screwdriver.
3. Clean around oil ll area.
4. Unscrew dipstick and wipe clean with cloth.
5. Reinsert dipstick without tightening.
6. If oil level is below the lower level line, rell with 10W-
30 (SJ, SL or better) oil to upper level line (capacity 30.4
ounces).
NOTE: Change oil and lter if contaminated. Refer to Oil
Maintenance.
WARNING
DO NOT REFILL TANK WHILE ENGINE IS RUNNING
OR HOT. ALWAYS CLOSE FUEL VALVE BEFORE
REFUELING.
BE CAREFUL NOT TO ALLOW DUST, DIRT, WATER
OR OTHER FOREIGN OBJECTS INTO FUEL.
DO NOT FILL ABOVE THE TOP OF THE FUEL
STRAINER OR IT MAY OVERFLOW WHEN THE FUEL
EXPANDS.
KEEP AWAY FROM OPEN FLAMES.
CAUTION
• DO NOT SPRAY WATER ON OR NEAR THE
ELECTRONICS OF THE GENERATOR AS THIS
MAY RESULT IN DAMAGE TO THE ELECTRICAL
COMPONENTS.
• ENGINE IS SHIPPED FROM FACTORY WITHOUT
OIL. YOU MUST ADD ENGINE OIL BEFORE
STARTING ENGINE. IF ENGINE IS STARTED
WITHOUT OIL, ENGINE MAY BE DAMAGED
BEYOND REPAIR AND WILL NOT BE COVERED BY
WARRANTY.
• NEVER STORE ENGINE WITH FUEL IN THE TANK
INDOORS. FUEL AND FUEL VAPORS ARE HIGHLY
FLAMMABLE.
• AN ADULT ONLY MUST ALWAYS HANDLE AND
FILL THE ENGINE WITH FUEL.
• ALWAYS HANDLE FUEL IN AWELLVENTILATED
AREA, OUTDOORS, AWAY FROM FLAMES OR
SPARKS.
• DO NOT START ENGINE IF FUEL IS SPILLED.
WIPE OFF EXCESS FUEL AND ALLOW TO DRY.
REMOVE ENGINE FROM AREA TO AVOID
SPARKS.
PREOPERATION CHECK
NOTE: Pre-Operation checks should be made each time
the generator is used.
Check Fuel
Make sure there is sucient fuel in the tank. If fuel is low, rell
with a minimum 87 octane gasoline. If fuel contains ethanol, a
fuel stabilizer should be used.
Be sure to use the fuel lter screen on the fuel strainer neck.
• Fuel tank capacity is 1.66 gallons.
FIGURE 3
REMOVE SIDE PANEL
UPPER LEVEL
LOWER LEVEL
OIL FILL CAP
20795-0008R1
SCREWS
SIDE
PANEL

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 13
Operator’s Manual
3200 Watt Inverter Generator
Ground Generator SEE FIGURE 5.
Make sure to properly ground the generator. The generator
must be on a rm, level surface with at least ve feet of
clearance on all sides.
Connect the Battery SEE FIGURE 4.
1. Loosen the two screws and remove the battery cover.
2. Clamp the RED wire to the POSITIVE (+) terminal.
3. Clamp the BLACK wire to the NEGATIVE (-) terminal.
Note: DO NOT reverse positions of the wire to the
terminal of the battery.
4. Make sure the battery is installed properly and securely.
5. Replace the battery cover and tighten the two screws.
Note: Recommended battery: 12V 6AH
20795-0003R1
GROUND GENERATOR WITH THE APPROPRIATE
AMOUNT OF COPPER FOR CURRENT CAPACITY.
COPPER WIRE
DIAMETER
0.005 IN/AMP
GENERATOR
GROUND SCREW
12V/6AH BATTERY
BATTERY BOX COVER
COVER SCREWS
20795-0017R1
FIGURE 4
FIGURE 5
Wheel Brake Operation SEE FIGURE 6.
The function of the wheel brake is to prevent the generator
from moving.
1. Press the brake lever down to engage the brake.
2. Lift up on the brake lever to release the brake.
20795-0018R1
BRAKE LEVER
FIGURE 6

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
14
c. Move the choke lever to the “RUN” position.
NOTE: The remote control triggers the automatic choke.
Therefore, the choke must be in the “RUN”
position at all times during remote starter use. For
recoil or electric starting procedures the unit must
be manually choked.
d. Press the “ON” button on the remote start transmitter
(key fob) twice.
NOTE:
• Allowing the engine to warm up a few minutes
without a load will prolong the life of the generator.
• If the unit was run out of fuel it may take several
attempts to prime the fuel system. Operating the
electric start also primes the fuel system.
• The remote start receiver will not accept the remote
start command if the battery is not fully charged.
Therefore a recoil or keyed electric start may be
necessary if the battery is not fully charged.
• For cold weather operation, store the unit in a cool
environment. Transferring the unit from a cold to
a warm place can cause the build up of harmful
condensation.
• Once the remote control “OFF” button is pressed it
will take 10 seconds before the remote “ON” button
reactivates.
• The remote control “ON” button must be pressed
twice in less than 3 seconds to send the start signal to
the remote start receiver.
• The unit will not start if the oil level is below the
recommended amount.
To Stop The Generator (SEE FIGURES 7&8)
1. Disconnect any electrical devices.
2. Turn ignition switch key to the“STOP” position, or press
the “OFF” button on the remote transmitter (key fob).
3. Turn the fuel valve to the “OFF” position.
CAUTION
• IF ENGINE FAILSTO START AFTER FOLLOWING
STARTING PROCEDURES, PLEASE CONTACT
OUR CUSTOMER SERVICE DEPARTMENT AT
8003456007.
• STARTER ROPE CAN CAUSE AN
UNANTICIPATED PULL TOWARDS ENGINE.
PLEASE FOLLOW INSTRUCTIONS TO AVOID
INJURY.
• NEVER LEAVE ENGINE RUNNING WHILE
UNATTENDED. TURN OFF AFTER EVERY USE.
• NEVER MOVE GENERATOR FROM ONE
LOCATION TO ANOTHER WHILE ENGINE IS
RUNNING.
• ALWAYS WEAR A PROTECTIVE HEARING
DEVICE.
• DO NOT START ENGINE IF FUEL IS SPILLED.
WIPE OFF EXCESS FUEL AND ALLOW TO DRY.
• STARTINGTHE GENERATORWITH ELECTRICAL
DEVICES CONNECTED COULD DAMAGE THE
GENERATOR AND THE CONNECTED DEVICES.
OPERATION
Starting the Generator (SEE FIGURES 7, 8 & 9)
1. Start the generator using the Recoil Starter as follows:
a. Turn the fuel shut o valve to the “ON” position.
b. Turn the ignition switch key to the “RUN” position.
c. Turn the Economy Mode switch to “OFF”.
d. Press the primer bulb 15 times.
e. Move the choke lever to the“CHOKE” position.
f. Pull the starter handle up to six times.
g. When the engine starts, feather choke lever to the
“RUN” position.
h. If engine does not start, prime and repeat again.
2. Start the generator using the Electric Starter as follows:
a. Turn the fuel shut o valve to the “ON” position.
b. Turn the Economy Mode switch to “OFF”.
c. Move the choke lever to the “CHOKE” position.
d. Turn the ignition switch key to the “START” position.
e. Release the key and allow the engine switch to turn
back to the“RUN” position.
g. When the engine starts, feather choke lever to the
“RUN” position.
3. Start the generator using the Remote Starter as follows:
a. Turn the fuel shut o valve to the “ON” position.
b. Turn the ignition switch key to the “RUN” position. FIGURE 7
20795-0007R1
ON
OFF

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 15
Operator’s Manual
3200 Watt Inverter Generator
FIGURE 8
AC/DC PROTECTOR
ECONONY MODE
20795-0006R1
ON
OFF
STOP
RUN
START
ELECTRIC START
OFF
ON
PUSH
FIGURE 9
250795-0009R1
USING ELECTRICAL POWER
AC Application:
1. Turn o the switch(es) of the electrical device(s) before
connecting to the generator.
2. Insert the plug(s) of the electrical device(s) into the
receptacle.
3. Start electrical device(s). Let run for a few moments
and then push the economy control switch to the“ON”
position.
Overload Indicator Light:
The overload indicator light comes on when an overload of
a connected electrical device is detected, the inverter unit
overheats or the AC output voltage rises. The electronic
breaker will then activate, stopping power to the generator
in order to protect the generator and any connected electric
devices. The output light (green) will icker and the overload
indicator light (red) will turn on, then the engine will stop
running. If so please follow the following steps:
1. Turn o any connected electric devices.
2. Reduce the total wattage of connected electric devices to
be within the generators range.
3. If total wattage is within range, check for blockages in
the cooling air inlet and around the control unit. If any
blockages are found, remove.
NOTE: The AC output of the generator automatically
resets when the engine is stopped and then
restarted.
4. Restart engine. Make sure to follow starting instructions.
DC Application (Option):
This usage is applicable to 12V battery charging only. Make
sure that the economy control switch is in the o position while
charging the battery.
1. Connect the battery charging cable to DC receptacle on
the generator.
NOTE:
A battery charging cable is included in the box.
2. Connect to the battery terminals using the charging
leads. Make sure the red lead is going to the positive (+)
post of the battery and the black lead is going to the
negative (-) post of the battery.
3. Once the connection is conrmed make sure the DC
circuit protector is in the ON position.
WARNING
DONOTUSEWORN,BARE,FRAYEDOR OTHERWISE
DAMAGED ELECTRICAL CORD SETS WITH THE
GENERATOR. DO NOT HANDLE ANY KIND OF
ELECTRICAL DEVICE WHILE STANDING IN WATER,
WHILE BAREFOOT OR WHILE HANDS OR FEET ARE
WET.
CAUTION
• BE SURE THE ELECTRICAL DEVICES ISARE
TURNED OFF BEFORE PLUGGING IN.
• BE SURE THAT THE TOTAL LOAD IS WITHIN
GENERATOR RATED OUTPUT.
• BE SURE THE SOCKET LOAD CURRENT IS
WITHIN THE SOCKET RATED CURRENT.
• THE ECONOMY CONTROL SWITCH MUST BE
TURNED TO THE OFF POSITION WHEN USING
ELECTRIC DEVICES THAT REQUIRE A LARGE
STARTING CURRENT.
• THE AC OUTPUT OF THE GENERATOR
AUTOMATICALLY RESETS WHEN THE ENGINE
IS STOPPED AND THEN RESTARTED.
• THE OVERLOAD INDICATOR LIGHT MAY COME
ON FOR A FEW SECONDS AT FIRST WHEN
USING ELECTRIC DEVICES THAT REQUIRE A
LARGE STARTING CURRENT.
• BE SURE THE ECONOMY CONTROL SWITCH
IS IN THE OFF POSITION WHILE CHARGING
BATTERIES WITH THE DC APPLICATION.

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
16
MAINTENANCE
Generator Maintenance
Please read the maintenance schedule and observe these recommendations to extend the life of your generator.
Good maintenance is essential for safe, economical, and trouble-free operation. It will also help reduce air pollution. To help you
properly care for your generator, the following pages include a maintenance schedule, routine inspection procedures, and simple
maintenance procedures using basic hand tools. Other service tasks that are more dicult, or require special tools, are best
handled by professionals and are normally performed by a technician or other qualied mechanic.
Maintenance, replacement or repair of the emissions control devices and systems may be performed by any non-road
engine repair establishment or individuals. However, items must be serviced by an authorized dealer to obtain“no charge”
emissions control service.
The maintenance schedule applies to normal operating conditions. If you operate your engine under unusual conditions, such as
sustained high-load or high-temperature operation, or use in unusually wet or dusty conditions, consult your servicing dealer for
recommendations applicable to your individual needs and use.
MAINTENANCE SCHEDULE
Maintenance Item Remarks Pre-operation
check (daily)
Every
20 hrs
Every 3
months
or 50 hrs
Every 6
months
or 100 hrs
Every 12
months
or 300 hrs
Spark Plug -
Type: TORCH A7RTC
(NGK CR7HSA)
Gap: 0.6 - 0.7 mm
Check condition, adjust gap and
clean. Replace if necessary.
X
Engine Oil Check oil level. X
Replace. X (1) X 2 X
Engine Oil Filter Replace X 2 X
Air Filter Clean. Replace if necessary. X
Fuel Strainer Clean fuel strainer.
Replace if necessary.
X
Choke Check choke operation. X
Valve Clearance -
Intake: 0.6 - 0.08 mm
(0.002 - 0.003”)
Exhaust: 0.08 - 0.10 mm
(0.003 - 0.004”)
Check and adjust when
engine is cold.
X
Fuel / Oil Lines Check hoses for crack or damage.
Replace if necessary.
X
Exhaust System Check for leakage.
Retighten if necessary.
X
Check muer screen.
Clean/replace if necessary
X
Starting System Check recoil starter operation. X
Screws / Fasteners Check that all hardware is secure.
Correct if necessary.
X
Generator Check the output light comes on. X
(1) After rst 20 hours of operation. (2) Under extreme conditions service sooner.

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 17
Operator’s Manual
3200 Watt Inverter Generator
CAUTION
• TEMPERATURE OF MUFFLER AND NEARBY
AREAS MAY EXCEED 150° F 65° C. AVOID
THESE AREAS.
• NEVER STORE ENGINEWITH FUEL INTHETANK
INSIDE A BUILDING. POTENTIAL SPARKS MAY
BE PRESENT FOR IGNITION OF FUEL AND
FUEL VAPORS.
• AN ADULT ONLY MUST DO MAINTENANCE
AND REPAIR ON GENERATOR.
• ENGINE MUST BE TURNED OFF AND COOL
BEFORE ANY REPAIR OR MAINTENANCE CAN
BE DONE.
• DO NOT OVER FILL THE ENGINE CRANKCASE
WITH OIL. HIGH OIL PRESSURE MAY RESULT,
CAUSING PREMATURE ENGINE WEAR AND
DAMAGE.
• BE SURE NO FOREIGN MATERIAL ENTERS THE
CRANKCASE WHEN ADDING OR CHANGING
OIL.
• DO NOT TILT GENERATOR WHEN ADDING OIL.
THIS COULD RESULT IN OVERFILLING AND
DAMAGE.
• THE ENGINE SHOULD NEVER RUN WITHOUT
THE AIR FILTER; EXCESSIVE PISTON AND/OR
CYLINDER WEAR MAY RESULT.
Steps For Working On Equipment
1. Turn the engine key switch to the“STOP” position.
2. Allow the generator to cool.
3. Make repairs as necessary. Do a nal safety check of all
parts repaired or replaced. Make sure all fasteners are
correctly tightened.
NOTE: Only use approved Porta Source spare parts.
Never replace parts that are not specically
designed for the generator.
Oil Maintenance
After the rst twenty hours of operating a new engine the oil
should be changed and lter should be cleaned, and every 100
hours of operating time thereafter. The oil should be changed
and lter should be cleaned every 50 hours if used under
severe conditions, such as in high temperatures or under
heavy loads. Check oil periodically (after every 20 hours of
operation on the hour meter); do not overll!
Engine oil Replacement
1. Place the machine on a level surface and warm up the
engine for several minutes. Then stop the engine and
turn the fuel valve to the“OFF” position.
2. Remove the side panel on the starter handle side of the
generator by loosening the two screws holding it in
place.
3. Remove the oil ll cap.
4. Place an oil pan under the engine. Tilt the generator to
drain the oil completely. Once oil has been removed
return the generator to the level surface.
5. Add engine oil, 10W-30 (API Service SJ, SL or better). Fill
to the upper level. For extreme high and low temperature
conditions refer to SAE chart. SEE FIGURE 10
6. Install the oil ll cap back in place.
7. Reconnect the side panel to the generator and tighten
the two screws.
Oil Filter Cleaning (every 100 hours) SEE FIGURE 11.
1. Do this as part of your oil change after you have drained
the oil completely.
2. Replace the oil ll cap before proceeding with the
following steps.
3. Remove the outer rubber seal.
4. Remove the inner rubber seal.
5. Remove the lter cap that secures the lter in place.
6. Remove the spring and oil lter (mesh wire basket).
7. Clean the lter with the appropriate solvent.
8. Dry the lter completely.
9. Reassemble the lter, spring and lter cap.
10. Reassemble the inner and outer rubber seals.
11. Stand the generator back up on its wheels.
12. Put fresh oil in the generator according to the
specications.
FIGURE 10
10W-40
10W-30
5W-30
-20 0 20 40 60 80 100 °F
-30 -20 -10 0 10 20 30 40 °C
Environment Temperature
SAE
20795-0019R1
20795-0020R1
OUTER
RUBBER
SEAL
INNER
RUBBER
SEAL
FILTER
CAP
FILTER
CAP
O-RING
SPRING
OIL
FILTER
FIGURE 11

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
18
Air Filter
Maintaining an air lter element in proper condition is
very important. Dirt induced through improperly installed,
improperly serviced, or inadequate lters damages and wears
out engines. Keep the lter clean.
Clean/Replace Air Filter Element as follows: SEE FIGURE 12
1. Remove the side panel on the starter handle side of the
generator by loosening the two screws holding it in
place.
2. Remove the air lter cover by loosening the six screws
holding it in place and then remove the air lter element.
3. Replace with a new oiled air lter element, or wash the
current air lter element with warm water and mild soap.
Remember to thoroughly oil the foam air lter element
with 30 or 40 weight motor oil and squeeze out any
excess oil before reinstalling it.
NOTE: Make sure to press the air lter element evenly
into place to ensure that the foam is fully seated
into its cover position.
4. Install the air lter cover and secure it with six screws.
5. Install the side panel, and secure with the two screws.
Clean/Replace Fuel Tank Strainer as follows: SEE FIGURE 13
1. Remove the fuel tank cap and strainer.
2. Clean the strainer with solvent. If damaged, replace.
3. Wipe the strainer and reinsert it.
NOTE: Make sure the tank cap is tightened securely.
Clean/Replace Spark Arrester as follows: SEE FIGURE 14
1. Remove the four screws that secure the muer shroud.
2. Remove muer clamp using a athead screwdriver. Slide
the spark arrester o the muer pipe.
4. Remove the carbon deposits on the spark arrester using a
wire brush. If damaged, replace.
5. Reinstall the spark arrester and secure with clamp.
6. Reinstall the muer shroud and secure with four screws.
Spark Plug
The recommended spark plug is a Torch A7RTC (NGK CR7HSA).
For maintenance and care of the spark plug go online to
www.portasourcegenerators.com for instructions or call Porta
Source customer service at 800-345-6007.
Carburetor
Never tamper with factory setting of the carburetor. FIGURE 14
WARNING
ALWAYS BE SURE THE TANK CAP IS TIGHTENED
SECURELY TO PREVENT FUEL SPILLS.
THE ENGINE AND MUFFLER WILL BE VERY HOT
AFTER THE ENGINE HAS BEEN RUNNING. ALLOW
ENGINE TO COOL BEFORE CLEANING/REPLACING
PARTS.
AVOID TOUCHING THE ENGINE OR MUFFLER
WHILE THEY ARE STILL HOT WITH ANY PART OF
YOUR BODY OR CLOTHING DURING INSPECTION
OR REPAIR.
FIGURE 12 20795-0010R1
AIR FILTER
ELEMENT
AIR FILTER COVER
SIDE
PANEL SCREWS
FIGURE 13
FUEL TANK CAP
FUEL TANK STRAINER
20795-0011R1
20795-0012R1
SCREWS
CLAMP
SPARK ARRESTER
MUFFLER SHROUD
IMPORTANT
NEVER TWIST AIR FILTERS WHEN CLEANING. ALWAYS
PRESS.TOO MUCH FORCEWILL DAMAGETHE ELEMENT.

Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5 19
Operator’s Manual
3200 Watt Inverter Generator
4. Remove spark plug. Pour about 1/2 ounce (15 ml) of
engine oil into the cylinder (the spark plug location).
Cover spark plug hole with rag. Pull the starting rope
several times to coat the cylinder wall with engine oil.
5. Install and tighten the spark plug.
6. Clean the generator outer surfaces. Check that cooling
air slots and openings on generator are open and
unobstructed.
7. Store the unit in a clean, dry place.
NOTE: Do not store gasoline from one season to another.
If possible, store the unit indoors and cover it to
give protection from dust and dirt.
TROUBLESHOOTING & REPAIR
At Porta Source , we build quality and durability into the
design of our products; but no amount of careful design by us,
and careful maintenance by you, can guarantee a repair-free
life for your Porta Source Inverter Generator. Most repairs will
be minor, and easily xed by following the suggestions in the
troubleshooting guide in this section.
The guide will help you pinpoint the causes of common
problems and identify remedies.
For more complicated repairs, you may want to rely on your
retailer, an authorized service center or go online to www.
portasourcegenerators.com for instructions or call Porta
Source Customer Service at 800-345-6007.
Porta Source will make the necessary repairs if a service center
is not available. A parts breakdown is located toward the end
of this manual.
We will always be glad to answer any questions you have, or
help you nd suitable assistance. To order parts or inquire
about warranty, call or e-mail us using the contact information
found in this section.
Ordering Replacement Parts
To order replacement parts visit www.PortaSourceGenerators.
com or call Porta Source Customer Service at 1-800-345-6007.
For other general questions, you can e-mail us at info@
ardisam.com.
Please include the following information with your order:
1) Part numbers
2) Part description
3) Quantity
4) Model number and serial number
Spare Parts
Only use approved Porta Source spare parts.
TRANSPORT & STORAGE
WARNING
DO NOT TRANSPORT GENERATOR INSIDE AN
ENCLOSED SPACE OR WITHIN A VEHICLE. FUEL
OR FUEL VAPORS MAY IGNITE CAUSING SERIOUS
INJURY OR DEATH.
Transporting Your Generator
1. After using the generator, and before transporting it,
make sure:
• the fuel cap is screwed on tightly (clockwise),
• the fuel valve is o.
2. If fuel is present in the fuel tank, transport in an open
vehicle in an upright position.
3. If an enclosed vehicle must be used, allow generator to
cool completely and then remove fuel into an approved
red fuel container. DO NOT siphon by mouth.
4. Wipe away any spilled fuel and allow to dry.
5. Run engine to use up the fuel in the carburetor and fuel
tank. Always run engine in a well ventilated area.
6. Fuel cap should be screwed down tightly, and fuel valve
o before transporting your generator in a vehicle.
7. Set the wheel brake to prevent the generator from
moving while transporting.
Long-Term Storage
If your generator will not be used for more than one month,
prepare it for long-term storage. It is important to prevent gum
deposits from forming in essential fuel system parts such as
the carburetor, fuel hose, or tank during long-term storage. It is
recommended to use a minimum 87 octane gasoline. Because
blended fuels can attract moisture that can damage the
engine, during storage a fuel stabilizer should be used.
Steps for Long-Term Storage
1. Allow generator to cool completely and then remove
all of the fuel from the fuel tank into an approved fuel
container. Discard appropriately.
2. Start and run engine to use up the fuel in the carburetor
and fuel tank. Be sure to close the fuel valve once
complete.
3. After the engine cools down, drain oil from crankcase.
Rell with recommended grade.

Operator’s Manual
3200 Watt Inverter Generator
Check for parts online at www.portasourcegenerators.com or call 800-345-6007 M-F 8-5
20
TROUBLESHOOTING GUIDE
PROBLEM POSSIBLE CAUSE REMEDY/ACTION
Engine will not start 1. Engine switch in STOP position 1. Turn engine key switch to RUN position
2. Out of fuel 2. Refuel
3. Fuel valve in OFF position 3. Turn fuel valve to ON position
4. Spark plug wire disconnected 4. Connect spark plug wire to spark plug
5. Spark plug wet, faulty or improperly gapped 5. Clean, replace or gap spark plug
6. Economy switch in ON position 6. Push economy switch to the OFF position; Once
generator is running Push to the ON position
7. Battery Disconnected 7. Reconnect battery terminals.
Engine starts, then
runs rough
1. Dirty air lter 1. Clean or replace air lter
2. Choke partially engaged 2. Turn o choke
3. Defective or dirty spark plug 3. Clean or replace spark plug
4. Economy switch is defective 4. Replace economy switch
5. Carburetor out of adjustment 5. Call Porta Source Customer Service
Engine is hard to start 1. Stale fuel 1. Drain old fuel and replace with fresh. Use fuel
stabilizer at end of season
2. Spark plug wire loose 2. Make sure spark wire is securely attached to
spark plug
3. Dirty carburetor 3. Clean carburetor, use fuel stabilizer, new fuel can
Engine misses or lacks
power
1. Clogged fuel tank 1. Remove and clean fuel tank
2. Clogged air lter 2. Clean or replace air lter
3. Carburetor out of adjustment or bad 3. Call Porta Source Customer Service
4. Spark plug wet, faulty or improperly gapped 4. Clean, replace or gap spark plug
Engine runs, then
quits
1. Low fuel level 1. Add fuel to tank
2. Incorrect engine oil level 2. Check engine oil level, add or drain as needed
3. Low RPM Sensor in protection mode 3. Wait 30 seconds for the low RPM Sensor to reset.
4. Contaminated fuel 4. Remove and replace contaminated fuel; Clean or
replace fuel strainer
5. Defective low oil level switch 5. Replace low oil level switch
6. Defective ignition coil 6. Replace ignition coil
Engine revs too high 1. Carburetor out of adjustment 1. Call Porta Source Customer Service
Engine speed increases and decreases, this is normal as the generator starts up and as loads vary.
Contact Porta Source Customer Service at 800-345-6007 if additional assistance is needed.
Table of contents
Popular Portable Generator manuals by other brands

Olympus
Olympus ESG-400 instructions

Firman
Firman P08013 Operator's manual

Shindaiwa
Shindaiwa DGW600DM-AC Generator user manual

Generac Power Systems
Generac Power Systems GP17500E specification

SIGLENT TECHNOLOGIES
SIGLENT TECHNOLOGIES SDG7000A Series quick start

JYE Tech
JYE Tech FG085 Function Generator Quick use guide

Toyama
Toyama TDMLG4004-T9C owner's manual

Champion
Champion Category 5 46512 Owner's manual & operating instructions

Aquavida
Aquavida AQ200 user manual

Dynascan Corporation
Dynascan Corporation E410C instruction manual

Robin America
Robin America RGV2800 Instructions for use

Mosa
Mosa S Series Use and maintenance manual