Positron BRX-XLR-8 User manual

WWW.POSITRONACCESS.COM
Document 180-0164-001 R07
BRX-XLR-8
8-pair Sealed Enclosure
Quick Start Guide
8 pairs from
the CO
8 pairs to the
subscriber (CPE)
Shielded gel-lled
26 AWG / 0.4 mm cable
Grounding Lug
Slot
#
Channel
#
Line
#
Cable Pair
Colors
11 1 White / Blue
2 2 White / Orange
21 3 White / Green
2 4 White / Brown
31 5 Red / Blue
2 6 Red / Orange
41 7 Red / Green
2 8 Red / Brown
Mounting ange on both
ends of the sealed unit
5101 Buchan Street, Suite 220, Montreal, QC H4P 2R9 Canada
Technical Support:
Toll-free: 1-888-577-5254 Tel: +1 514-345-2220
[email protected]
© Positron Access Solutions
Document 180-0164-001 R07
Summary Diagram of Typical Installation
DSLAM BRX-XLR-8
L1
Distance from DSLAM to BRX-XLR-8
L2
Distance from BRX-XLR-8 to CPE
IMPORTANT NOTE: The BRX-XLR unit is powered from the Sealing
Current found on a standard POTS pair. Each pair of the BRX-XLR-8
is powered independently with each pair requiring the presence
of the -48Vdc sealing current for proper operation. The BRX-XLR-8
will not operate on a dry pair (line with no -48Vdc sealing current).
You can use the Positron BRX Power Injector to provide the -48Vdc
sealing current when operating on dry pairs.
Connecting the BRX-XLR-8
Step 1: Select the location where the BRX-XLR-8 will be inserted using the
BRX Cloud Calculator for the longest loop.
Step 2: Connect the grounding lug of the unit to a proper ground (usually
available near the splice point).
Step 3: Insert a BRX-BYPASS-TEST module in slot 1 and ensure that both
switches are in BYPASS mode.
Step 4: Connect the rst two (2) pairs to be amplied to the rst two (2)
pairs of the BRX-XLR-8. Make sure to match the DSLAM pair number to
the CPE pair number.
Step 5: Test for continuity between the DSLAM pair and CPE pair at the
splice point. If the circuits are active, the LEDs on the BRX-BYPASS-TEST
module will be ON to conrm that the sealing current is present on both
lines. If either circuit is not active, the continuity testing will conrm that
the connections are reliable.
Step 6: Replace the BRX-BYPASS-TEST module with a BRX-XLR-M
module.
Step 7: The DSLAM and CPE will now retrain the circuit and bring up the
ADSL2+ / ADSL link with the amplied bandwidth. The performance may
be limited (or capped) by a setting in the DSLAM conguration.
Step 8: Repeat steps 3 to 7 for the other three (3) slots of the BRX-XLR-8
enclosure.
CPE
Placement Guidelines for BRX-XLR Devices
The BRX-XLR amplies ADSL2+ and ADSL loops and is designed to deliver
solid amplication of the loops as long as the BRX-XLR device is installed
within 45% to 75% of the total loop distance. It is recommended to install
the BRX-XLR unit at an existing splice point that is within the recommended
placement range. When multiple splice points exist within that range, you
should select the one that is most convenient.
The BRX-XLR installation should follow these simple rules:
1. L1 - Minimum Loop Length from DSLAM to BRX-XLR should be
no less than 6500 feet (2 km) for 24 AWG (0.5 mm) gauge or 5000 feet
(1.5 km) for 26 AWG (0.4 mm) gauge.
2. L2 - Minimum Loop Length from CPE to BRX-XLR should be no less
than 650 feet (200 m) for 24 AWG (0.5mm) gauge or 500 feet (150 m) for
26 AWG (0.4 mm) gauge.
For a 10 / 1 Mbps service, the recommended range is as follows (single pair):
• Maximum total loop length: 17500 feet (5.3 km) for 24 AWG (0.5mm)
gauge or 12750 feet (3.9 km) for 26 WG (0.4 mm) gauge.
• Recommended placement range: 8000 to 12000 feet (2.4 to 3.6 km)
of 24 AWG (0.5mm) gauge or 5700 to 8900 feet (1.7 to 2.7 km) of 26
AWG (0.4 mm) gauge.
The BRX Cloud Calculator can help determine the optimal installation
location for each specic loop. To access the BRX Cloud Calculator, sign
up on the Positron Access Portal at www.positronaccess.com/Portal.php.
You will get a username and password to access the Portal.
Recommended DSLAM Settings
Parameter Downstream Upstream
Maximum Bitrate 32000 kbps 1296 kbps
Maximum Delay 8 msec 8 msec
Path Latency Interleaved
Impulse Noise Protection (INP) 2 1
Target SNR Margin 6.0 dB 6.0 dB
In order to fully benet from the amplied ADSL2+ / ADSL signal, there are a
few DSLAM settings to be set as per the following recommendation:
You should also make sure that the DSLAM and/or the BRAS settings are not
set at a lower level than the target service offered to the subscriber for this loop.
NOTE: You should always follow your corporate guidelines for the DSLAM
settings if they differ from the Positron recommendation. If in doubt, you
should check with the Engineering or Operation team.

Other manuals for BRX-XLR-8

5

Other Positron Enclosure manuals

Positron BRX-VDSL2-2 User manual

Positron

Positron BRX-VDSL2-2 User manual

Positron BRX-VDSL2 User manual

Positron

Positron BRX-VDSL2 User manual

Positron BRX-XLR-8 User manual

Positron

Positron BRX-XLR-8 User manual

Positron BRX-VDSL2-24 User manual

Positron

Positron BRX-VDSL2-24 User manual

Positron BRX-VDSL2-8 User manual

Positron

Positron BRX-VDSL2-8 User manual

Positron BRX-XLR-2 User manual

Positron

Positron BRX-XLR-2 User manual

Positron BRX-XLR-8 User manual

Positron

Positron BRX-XLR-8 User manual

Positron BRX-XLR-8 User manual

Positron

Positron BRX-XLR-8 User manual

Positron BRX-XLR-1 User manual

Positron

Positron BRX-XLR-1 User manual

Positron BRX-XLR-2 User manual

Positron

Positron BRX-XLR-2 User manual

Positron BRX-VDSL2-2 User manual

Positron

Positron BRX-VDSL2-2 User manual

Positron BRX-VDSL2-2 User manual

Positron

Positron BRX-VDSL2-2 User manual

Positron BRX-XLR-2 User manual

Positron

Positron BRX-XLR-2 User manual

Positron BRX-XLR-8 User manual

Positron

Positron BRX-XLR-8 User manual

Positron BRX-VDSL2-8 User manual

Positron

Positron BRX-VDSL2-8 User manual

Positron BRX-XLR-8 User manual

Positron

Positron BRX-XLR-8 User manual

Positron BRX-XLR-24 User manual

Positron

Positron BRX-XLR-24 User manual

Popular Enclosure manuals by other brands

Western Digital WDBABT0010HBK - My Book AV DVR Expander Quick install guide

Western Digital

Western Digital WDBABT0010HBK - My Book AV DVR Expander Quick install guide

Contractors Wardrobe 7800 installation instructions

Contractors Wardrobe

Contractors Wardrobe 7800 installation instructions

SICK GMS840 ADDENDUM TO OPERATING INSTRUCTIONS

SICK

SICK GMS840 ADDENDUM TO OPERATING INSTRUCTIONS

Stardom SOHORAID ST8-TB3 user manual

Stardom

Stardom SOHORAID ST8-TB3 user manual

HP D6000 Disk Enclosure Quickspecs

HP

HP D6000 Disk Enclosure Quickspecs

Lenel LNL-200XAU quick reference

Lenel

Lenel LNL-200XAU quick reference

Rosewill RDEE-12002 user manual

Rosewill

Rosewill RDEE-12002 user manual

Laney R210 quick start guide

Laney

Laney R210 quick start guide

IBM Small J10 Series manual

IBM

IBM Small J10 Series manual

Cyber Power CR U6 Series user manual

Cyber Power

Cyber Power CR U6 Series user manual

Nanoxia DEEP SILENCE 2 manual

Nanoxia

Nanoxia DEEP SILENCE 2 manual

Wheelock EN4 installation instructions

Wheelock

Wheelock EN4 installation instructions

nVent Hoffman f22lb installation instructions

nVent Hoffman

nVent Hoffman f22lb installation instructions

Addonics Technologies ZESSIU3CS user guide

Addonics Technologies

Addonics Technologies ZESSIU3CS user guide

Bartec Varnost 07-56 Series Operational Instruction

Bartec Varnost

Bartec Varnost 07-56 Series Operational Instruction

MTX THUNDERFORM installation instructions

MTX

MTX THUNDERFORM installation instructions

Dell PowerEdge C6400 Installation and service manual

Dell

Dell PowerEdge C6400 Installation and service manual

CEPTER CARAPACE SUPER TOWER T.G. RGB CASE Quick installation guide

CEPTER

CEPTER CARAPACE SUPER TOWER T.G. RGB CASE Quick installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.