Power Probe The Hook User manual

Instruction
Manual
The Ultimate Circuit Tester
www.powerprobe.com • 800-655-3585

The Power Probe Hook Operations Manual
Thank you for purchasing Power Probe’s Hook electronic circuit tester. Ergonomically designed so it can be
“Hooked” to the vehicle thus eliminating the need to balance it on a fender or worse, lay on the oor where
it could be crushed or stepped on! The Hook is designed to give you years of trouble free diagnostic power,
even in the most demanding work environments.
If you have any questions please go to our website www.powerprobe.com or give us a call: 800-655-3585.
The Serial Number can also be found on the back of the unit or box.
CAUTION - PLEASE READ
• Power Probe recommends reading this manual before using the Hook.
• This product is designed to be powered from DC power sources such as found in Automotive,
Small Craft Marine and Small Craft Aviation electrical systems and will be damaged if
connected to line voltage such as 115V AC power sources or 24V AC Control circuits.
• Do not connect to electrical systems with higher than the rated voltage as specied in
this manual.
• Before using, inspect the case, probe tip, cable and accessories for damage. When in doubt,
have the Hook serviced by Power Probe’s repair department.
• Do not use Hook if it operates abnormally, the safety features may be disabled. When in doubt,
have the Hook serviced by Power Probe’s repair department.
• Only operate in well ventilated areas, do not operate around ammable materials, vapor or dust.
• Only use shrouded leads and accessories authorized by Power Probe to minimize
exposed conductive electrical connections to eliminate shock hazard.
• Due to the high output currents the Hook produces, be careful when energizing components
that have moving parts, assemblies containing motors or high powered solenoids.
• Do not open the Hook, no serviceable parts are inside. Opening the Hook voids the warranty.
• Power Probe, Inc. shall not be liable for damage to vehicles or components caused by misuse.
• The Hook should not be left unattended while connected to a circuit or used by untrained
technicians.
• Power Probe, Inc. shall not be held liable for any harm caused by unintentional or
intentional misuse of our products or tools.

Removable
Probe Tip
Continuity Jack
& Rubber Cover
Speaker
Positive and
Negative
indicator lights
LCD
backlit
display
5 button
Navigation
“Hook” for
easy
hanging
Auxiliary Ground
Lead with a 4mm
gold plated jack
with 20A fuse.
START-UP................................................................................................................................4-I
Operating Voltage Source .......................................................................................................4-Ia
Connecting to the Vehicle’s Battery (Voltage Source) ............................................................4-Ib
Y-Connector with Battery Clips ................................................................................................4-Ic
Auxiliary Ground Lead............................................................................................................4-Id
Flashlight.................................................................................................................................4-Ie
Sleep Mode..............................................................................................................................4-If
FIVE BUTTON OPERATIONAL TERMS .....................................................................................5-II
PREFERENCES AND SETTINGS................................................................................................5-III
Preference Line .......................................................................................................................5-III a
Speaker ON/OFF .....................................................................................................................5-III b
Circuit Breaker Preferences.....................................................................................................5-III c
Power Switch Preferences .......................................................................................................6-III d
AC Threshold Preferences........................................................................................................6-III e
LED Voltage Drop Preferences................................................................................................6-III f
POWER PROBE HOOK MODE.... (the Smart Tip Advantage)..................................................7-IV
Voltage Testing in Power Probe Hook Mode:.........................................................................7-IV a
Resistance Testing in Power Probe Hook Mode:.....................................................................7-IV b
Activating Components, Current Draw Testing and Calculated Resistance in Power Probe Hook Mode:..........8-IV c
Hot Shot®Testing in Power Probe Hook Mode: ....................................................................9-IV d
Dual Meter Feature: ...............................................................................................................9-IV e
CONTINUITY and RELAY TESTER............................................................................................10-V
POWER PLUS MODE ...............................................................................................................11-VI
VOLT METER MODE ................................................................................................................11-VII
OHM METER MODE .................................................................................................................12-VIII
INJECTOR MODE .....................................................................................................................13 IX
COUNTER MODE......................................................................................................................14-X
Duty Cycle Frequency.............................................................................................................14-Xa
Positive Pulse Width/Frequency............................................................................................14-Xb
Negative Pulse Width/Frequency ..........................................................................................14-Xc
Pulse Counter........................................................................................................................14-Xd
VOLTAGE REFERENCE SUPPLY MODE....................................................................................15-XI
CONTRAST...............................................................................................................................15-XII
SAVE PREFERENCES AND DEFAULT SETTINGS......................................................................16-XIII
SAFETY ....................................................................................................................................17
FACTS AND TIPS .....................................................................................................................18
SPECIFICATIONS......................................................................................................................19
ENVIRONMENTAL....................................................................................................................19
NOTES .....................................................................................................................................20 & 21
10 Gauge
Power Lead
Battery
voltage
Preferences
settings
4mm
banana jack
PPH1 Kit includes:
Power Probe Hook
3” Probe Tip
Battery hook-up clips
3 Wire Continuity Leads
Instruction manual
Table of Contents

HOM
1
H
00
Page 4
a) Operating Voltage Source
The Hook is designed for use in 12 to 48 VDC electrical sys-
tems and comes supplied with a 20 ft., 10-gauge coax cable
and 2 heavy-duty battery hook-up clips.
b) Connecting to the Vehicle’s Battery
(Voltage Source)
Connect the red clip to the positive terminal of the vehicles
battery source and the black clip to negative or ground. The
Hook start-up tone will sound and the indicator light on the Y-
Connector with Battery Clips will illuminate. This tells you that
the Hook is connected correctly and the internal fuse of the
Y-battery-clip-connector is working properly.
c) Y-Connector with Battery Clips
The Y-Connector with Battery Clips has a safety fuse built into
it. The built-in fuse will blow in the event the 10-gauge coax
power cable gets clamped or pinched in a door or hood caus-
ing a short circuit.
Note: If the Y-Connector with Battery Clips does not light when
properly connected to the voltage source, you probably have a
damaged 10 gauge coax power cable. It is recommended that
the cable be inspected and tested before replacing a new Y-
Connector with Battery Clips.
Contact your distributor or Power Probe, Inc. for a replacement.
d) Auxiliary Ground Lead
The auxiliary ground lead provides ground to circuits and com-
ponents that are not connected to ground. It also serves as the
negative lead for resistance testing.
To test the auxiliary ground lead, contact the probe tip and the
auxiliary ground lead together. The Green LED on the display
should light. This shows that the auxiliary ground lead is work-
ing properly.
If the green LED does not illuminate, check the replaceable
20 amp fuse (5x20mm fast blow) in the auxiliary ground lead.
The fuse is a protection in the event the lead is inadvertently
contacted with battery positive.
e) Flashlight
Flashlight is a standard feature on the Hook. The bright LED
Flashlight is always ON making it possible to probe under
dashboards and in dark areas.
f) Sleep Mode
The Hook will go to sleep after 10 minutes of inactivity and you
will see the word SLEEPING on the display. The Flashlight
and the LCD backlight will turn off. To wake it up, just press
any button or contact the probe tip to a circuit.
I -START-UP
Flashlight
Lights up when
connected to a
power source.
Y-Connector
Green LED
12 - 48 VDC
To replace the fuse
remove cover.
S E
LN
PIE G
52 0M50
1
ATT
B0
2

The Five Button Switch performs many different functions
depending on the state of which the Hook is in at the time. To
standardize our terminology when referring to the individual
buttons of the Five Button Switch, we will use the following
identiers: U, D, L, R, and SEL.
See the terms and denitions below:
U = (+) = UP BUTTON or TOP BUTTON
D = (–) = DOWN BUTTON or BOTTOM BUTTON
L = (Speaker symbol) or LEFT BUTTON
R = (Hot Shot symbol) or RIGHT BUTTON
SEL = SELECT BUTTON or CENTER BUTTON
AC Threshold
Setting in Volts
Speaker On/Off
Circuit Breaker
Setting in Amps
Power Switch Settings
DC Voltage
Drop Setting
52 0M50
1
ATT
B0
2
II -FIVE BUTTON OPERATIONAL TERMS
On
Off
5
2
0M50
1
A
TT
B
0
2
5
2
0M 0
1
A
TT
B
0
2
5
Press to toggle
On or Off
D
U
RL
III -PREFERENCES AND SETTINGS
a) Preference Line (Top Row)
In Power Probe Hook Mode with the probe tip oating or un-
loaded, the top line of the display shows the present operating
parameters of the Hook. You will want to become very familiar
with the preference line of the Hook so you will know exactly
how it will operate at any given time.
b) Speaker ON/OFF
To toggle the speaker ON or OFF in Power Probe Hook Mode:
1. Press L (Speaker symbol)
2. Notice the speaker symbol in far left of the preference line
when the speaker is visible in the Display. This means the
Polarity Tone is ON.
(Power Probe Hook Mode is the only mode you can toggle the
speaker on/off.)
c) Circuit Breaker Preferences
To adjust and set the Circuit Breaker Preferences
while in Power Probe Hook Mode:
1. Press SEL once. Display shows CIR BREAKR.
2. Press L or R to the desired trip point: 2A, 3A, 4A, 5A, 7A,
7.5A, 10A, 15A, 20A, 25A, 30A, 35A, 40A, 50A, or 65A.
3. Press SEL to return to Power Probe Hook Mode.
4. Notice the new Circuit Breaker Setting in the
preference line.
The circuit breaker settings of 2, 3, 4, 5, 7.5, 10, 15, 20, 25,
30, 35, 40, 50 and 65 will have been added to give you a com-
plete selection of choices. We have rened the circuit breaker
to handle real world testing of components.
KAC RBRER
5A
6
I
SEL
Preference Line
Battery Voltage
(Fig. IIIa.)
6
Page 5

Page 6
OR
EV
DP
LD
5
SE
CTHR
50
A
CTP WS
WIH
E
PULS
O
.5 sec
.5 sec
.5 sec
On_
Off
Press &
Release
START
Press &
Release
STOP
Press &
Release
ON
Press &
Release
OFF
CT
PWSWI H
H
LATC
O
CTP WS
WIH
N
MOME T
O
Press
ON
Release
OFF
On_
Off
On_
Off
d) Power Switch Preferences
To adjust and set the Power Switch Preferences
while in Power Probe Hook Mode:
1. Press SEL once.
2. Press D once. Display shows POW SWITCH.
3. Press L or R to select the desired Power Switch preference:
LATCH, PULSE or MOMENT.
4. Press SEL to return to Power Probe Hook Mode
5. Notice the new Power Switch Setting in the preference line.
Power Switch Behaviors when in Power Probe Hook Mode:
Moment: When the Power Switch Setting is set to Moment,
battery source power or ground is supplied to the probe tip
when you press and hold U(+) or D(–).
Latch: When the Power Switch Settings are set to Latch, you
can hold continuous battery positive or ground to the probe tip,
by pressing the U(+) or D(–). To release power, press U(+) or
D(–) again.
Pulse: When the Power Switch Setting is set to Pulse, the
Hook will cycle battery positive or ground to the probe tip by
pressing U(+) or D(–).
It cycles ON for 1 second, then OFF for 1 second repeatedly.
To stop the power cycling, press U(+) or D(–) again.
e) AC Threshold Preferences
To adjust and set the AC Threshold Preferences
while in Power Probe Hook Mode:
1. Press SEL, once.
2. Press D, twice. Display shows AC THRES.
3. Press L, or R, to select the desired AC Threshold
preference: .1, .2, .5, 1, 2, 5, 10, 20, or 50 (Recommended).
4. Press SEL to return to Power Probe Hook Mode
f) LED Voltage Drop Preferences
Long extended circuits/wire runs such as trailers and heavy
equipment may require a larger voltage drop setting for proper
testing
To adjust and set the LED Voltage Drop Preferences
while in Power Probe Hook Mode:
1. Press SEL once.
2. Press D, 3 times. Display shows LED V DROP.
3. Press R or L, to select the desired Voltage Drop preference:
.2, .5, 1, 2, or 3.
4. Press SEL to return to Power Probe Hook Mode
5. Notice the new LED Voltage Drop Setting in the
preference line.
III Continued
(page 5 Fig. IIIa.)
(page 5 Fig. IIIa.)

Page 7
a) Voltage Testing in Power Probe
Hook Mode:
Voltage testing is as easy as contacting the probe tip to a
circuit and reading the display. There is no need to select the
voltmeter before probing because the Hook does that automat-
ically. The Hook also provides both the battery source voltage
and the probe tip voltage on the display screen for easy volt-
age comparing.
To test for voltage in Power Probe Hook Mode:
1. Take note of the preference parameters in the display.
2. Contact the probe tip to a voltage potential.
3. Take note of the difference between VOLT and BATT on
the display.
If the voltage difference is within the LED Voltage Drop Prefer-
ences, the Red LED will light and the HOT SHOT®symbol will
be present.
If the voltage difference is greater than the LED Voltage Drop
Preferences, the LED will not light.
4. Voltage is measured from 0 to 99.9 volts.
IV - POWER PROBE HOOK MODE
In Power Probe Hook Mode the “Smart Tip Advantage” gives you several new powerful tools to
help you x electrical problems faster than any other circuit tester in its class. Why?
Because it automatically selects the:
RIGHT METER and the RIGHT FUNCTION for the RIGHT CIRCUIT condition.
Resistance Testing
100Ω
HOM
0
0
1 0
b) Resistance Testing in Power Probe
Hook Mode:
Resistance testing is as easy as contacting the probe tip to
a circuit or a component and reading the display. There is no
need to select the Ohm Meter before probing because the
Hook does that automatically. It will also auto-range the deci-
mal point.
To test for resistance in Power Probe Hook Mode:
1. Contact the probe tip to a circuit or component with
resistance to ground. Resistance is measured and
displayed from 0 to 15 mega ohms. When Resistance is
less than 1 Ohm the Green LED will be on.
It is necessary to connect the ground lead to a chassis or other
common ground point to accurately measure 2 Ohms or less.
This will eliminate voltage drops within the 20 ft cable and
improve the accuracy.
When testing resis-
tance on some chassis
grounds even though
the ignition is turned
off, you may experi-
ence a millivolt potential
present. When that
happens, The Hook will
display a Dual Meter.
Please see “Dual Meter
Feature” on page: 9-IV f
OT
VL8
BAT126
T
11
Voltage Testing
11.8V
NEVER: Perform any tests on any SRS system without the system being completely disabled, modules unplugged and
simulators installed in place of all pyrotechnics. Doing so can lead to injury do to unwanted deployment and permanent
module damage.

Page 8
c) Activating Components, Current Draw
Testing and Calculated Resistance in
Power Probe Hook Mode:
Activating Electrical Components in Power Probe Hook Mode
is one of the main features that make the Hook very useful. The
Power Switch (+) and (–) behave differently according to the
Switch Preferences. Notice the Power Switch Settings on the
preference line (see section III-a), for Power Switch Behaviors
(see section III-d).
On 12 volt systems the incidence of arcing is low for ease of
operation. Arc Detect has been disabled in all modes. Arc de-
tect is functional in Power Probe mode only when the source
voltage exceeds 16V. Arc detect can interfere with the function
of some devices. When using the HOOK on vehicles with 24V
and above source voltage. It may be necessary to use Power
Plus mode when the devices you are powering are electrically
very noisy as on some motors or horns. Use caution and follow
instructions on how to properly power up a circuit. Because of
the danger present with higher voltages to the vehicle and you,
it is recommended to use Power Plus mode for powering up in
these higher voltage systems when possible.
Current Draw Testing and Calculated Resistance are dy-
namic tests that are performed by activating circuits or electrical
components with the vehicle’s battery power through the Hook
and measuring the Amps and Ohms. Since the measurements
are made while under power you are getting a true indication as
to its real operating integrity.
To test the current draw and calculated resistance of an
electrical component in Power Probe Hook Mode:
1. Contact the probe tip to the positive terminal of an electric
component that is properly grounded.
2. Press and hold (+). The Hook supplies power to activate it.
During activation the Hook displays the AMMETER and OHM
METER simultaneously.
3. Read the Current Draw displayed as AMP on the screen.
4. Read the Calculated Resistance displayed as OHM on the
screen.
5. If the display shows CIR BREAKR TRIP when you attempt
to activate the electrical component, you will need to
increase the trip point by adjusting it in the Circuit Breaker
preferences. (See section: III-c)
NOTE: The same measurments also can be taken on a battery
(+) referenced circuits by pressing the (-) button.
Starter
Motor
Solenoid
clicks when
Activated
Press & Hold
the (+) Power
button
M
AP 0
20
55
1
H
OM 2
Load Activated
Ground
Battery Volts
Battery Volts
Press
Power
Switch
Ground
IV Continued

Page 9
Good Ground Corrosion
OTHH
PA
SOT
SS
OTHH
FA
SOT
IL
Press &
hold Hot
Shot®
Press &
hold Hot
Shot®
IV Continued
HOM
1
H
00
Hot Shot
e) Dual Meter Feature:
The Dual Meter feature is available only in Power Probe HOOK
Mode. When diagnosing chassis grounds it is possible to have
voltage drops caused by systems within the vehicle operating
when the key is off. It can take several minutes for the systems
to shut down. If you are turning the key on and off for diagnosing
purposes, it can be difcult to get accurate resistance readings
due to the voltage drops. Typically ohmmeters will give you a
reading that is skewed by these voltage drops and if you are
unaware they are there, you could spend time xing problems
that don’t exist.
If there are millivolts present on a chassis ground the Power
Probe HOOK will display a unique feature we call Dual Meter.
You will get a resistance reading on the bottom of the screen
and a millivolt reading on the top of the screen at the same
time. The ohm reading displayed when this feature is active will
have a coarse correction factor intended to improve accuracy.
In Power Probe HOOK mode, this feature will automatically
display when the voltage on ground is between .002 and .200
millivolts and ohms is less than 250. If the voltage drops below
.002 volts, normal ohmmeter will display. If there is between
.002 and .200 volts present and the ohms exceed 250, normal
ohmmeter will display. Above 250 ohms, millivolts will have no
affect on the ohm reading. If the voltage exceeds .200 volts,
M
AP 0
20
55
1
H
OM 2
d) Hot Shot®Testing in Power Probe
Hook Mode:
Hot Shot®is available at all source voltages from 12 to 48. The
rule of thumb is that when the Hot shot feature is available,
you can verify the resistance of that circuit is > or < 1 ohm. If
you get a pass result you know the resistance is < 1 ohm and
you have a good power feed connection. A fail result indicates
>1 ohm. For reference, the source voltage does affect the out-
come of the pass result. All pass results reect less than 1
ohm but there is a value difference depending on the source
voltage. Pass at 12V = <.2 ohms, 24V = <.4 ohms, 36V = <.6
ohms, 48V = <.8 ohms. All are less than 1 ohm, but under-
standing this may help in your diagnosis.
WARNING: HOT SHOT®is only designed for supply powers
and grounds. HOT SHOT®should never be used on any sensi-
tive electronics such as modules, sensors etc.
NEVER: Perform any tests on any SRS system without the
system being completely disabled, modules unplugged and
simulators installed in place of all pyrotechnics. Doing so can
lead to injury do to unwanted deployment and permanent mod-
ule damage.
WARNING: When working on computer grounds or any oth-
er sensitive circuits, HOT SHOT®should not be used. The
components need to be unplugged (modules, relays, sensors,
switches, etc.) Now HOT SHOT®can be used to load the wiring
not the component. This is the true method that HOT SHOT®is
intended for, the wiring not the components.

The Hook has a built in two channel Continuity Tester for testing relays and electrical switches. You will also be apply-
ing power to the relay coil using the auxiliary ground lead and the probe tip.
When the 3 wire continuity plug is inserted into the jack, the Red/Green LED’s are now dedicated to the Continuity
Tester. You can still use the Hook normally to power up or read voltage, ohms or amps.
To test a 5 terminal relay in Power Probe Hook Mode:
1. Pull the Rubber Cover from the Continuity Jack and
swivel it out of the way.
2. Insert the 3 Wire Continuity Plug into the Continuity Jack.
3. Connect the Black lead to relay terminal #30.
4. Connect the Green lead to relay terminal #87a. (the Green
LED should light)
5. Connect the Red lead to relay terminal #87.
6. Connect the Hook Auxiliary Ground Lead to terminal #86
7. Contact the Hook Probe Tip to terminal #85.
8. Press (+). (the Red LED should light and the Green LED
should go off)
9. Release (+). (the Red LED should turn off and the Green
LED should light)
V- CONTINUITY TESTER AND RELAY TESTER
85
86 87A
87
30
30
86
87
85
87A
M
AP 2
10
1
Red light on
M
AP 2
10
1
Press &
hold Power
Switch +
30
86
87
85
87A
M
AP 2
10
1
Green light on
M
AP 2
10
1
No
contact
No contact
Solenoid
NC
Feed
NO
Open
Rubber
Cover
normal voltmeter will automatically kick in. With Dual Meter feature, you can better diagnose grounds in the presence
of voltage drops without having to waste time waiting for the systems to shut down! Now that’s a Smart Tip Advantage!
Interpreting the data: The intention of this data is to inform you that accurate resistance measurements cannot take place
when millivolts are present. Standard ohmmeter readings will provide completely unusable data under this condition.
Is your high resistance reading due to a poor connection or a voltage drop? The Power Probe HOOK is the rst in the industry to
answer this question in one simple test. With the Dual Meter feature you are now alerted to the voltage drop while conducting a
resistance test. The HOOK will supply you a more accurate resistance reading during this scenario. The fact remains that if you
see a voltage drop during the resistance test, you will need to remove the voltage drop to acquire the most accurate resistance
reading, however, now you can continue testing using the Dual Meter with the voltage drop present and the resistance value
as a guide since The HOOK is displaying a more accurate reading under this condition.
Note: Due to voltage drops inherent in the 20 foot power cable the ohm meter may experience some error below .30 ohms
depending on the distance from battery to your measurement.
Contact
Page 10

Page 11
(a) Arc Detect
On 12 volt systems, the incidence of arcing is low therefore, for ease of operation the Arc Detect has been disabled in all
modes. Arc detect is functional in Power Probe mode only when the source voltage exceeds 16V. Arc detect can interfere
with the function of some devices. When using the HOOK on vehicles with 24V and above source voltage, it may be neces-
sary to use Power Plus mode if the device you are powering are electrically very noisy as on some motors or horns. Use
caution and follow instructions on how to properly power up a circuit. Because of the danger present with higher voltages
to the vehicle and you, it is recommended to use Power Probe mode for powering up in these higher voltage systems when
VI - POWER PLUS MODE
ARC DETECT IS DISABLED! Use CAUTION
This is an active mode used for activating electrical components similar to Power Probe Hook Mode except the Arc Detect
feature is disabled. The Power Switch and Circuit Breaker Preferences apply here in Power Plus Mode as they do in
Power Probe Hook Mode. Power Plus Mode will measure and display the Min/Max Current draw so you capture in rush
and stabilized current. High current can be an indication of a sticking or dragging motor or pump.
To access Power Plus Mode from Power Probe Hook Mode:
1. Press SEL once.
2. Press U once
3. Press SEL.
4. You should see AMP in the display.
To activate an electrical component in Power Plus Mode:
1. If the electrical component is already grounded in the
vehicle, you can skip step 2.
2. Connect the auxiliary ground lead to the ground of the
electrical component.
3. Contact the probe tip to the positive terminal of the
component.
4. Press (+). The component should activate.
5. Read the display for the average current draw along with
the Min/Max measurements.
6. To reset the Min/Max Press R
VII - VOLT METER MODE
The Volt Meter Mode is a passive mode. The (+) Power and (–)
Power buttons are not active so dynamic circuit testing cannot
be performed. This means, no Power will be activated to the
probe tip even when you press the Power buttons.
Volt Meter Mode monitors the probe tip and displays 3 voltage
measurements, Average, Min. and Max.
Min/Max can be reset by pressing the R button.
To access Volt Meter Mode from Power Probe Hook Mode:
1. Press SEL once.
2. Press D, 4 times.
3. Press SEL once.
4. Connect the probe tip to the circuit you want to
monitor and test.
5. Press R to reset the Min/Max
OT
VL0
00
OT
VL21 6
21 621 6
OT
VL21 6
021 6
Now reset by pressing the
RIGHT ARROW button. Min is
now the same as Max.
When you touch the tip to the
positive battery post the aver-
age reading and the max will
read the same. The Min will
remain 0 since it recorded the
previous low.
M
AP00
00 00

VIII - OHM METER MODE
Ohm Meter Mode monitors the probe tip and displays 3 resis-
tance measurements, Active, Min. and Max. The Ohm Meter
Mode is a passive mode. This means no Power will be activat-
ed to the probe tip even when you press the Power buttons.
To access Ohm Meter Mode from Power Probe Hook Mode:
1. Press SEL once.
2. Press D, 5 times.
3. Press SEL once.
4. Connect the probe tip to the circuit you want to monitor
and test.
5. Press R to reset the Min/Max.
This mode can only display ohms. In order for Ohm Meter
Mode to operate there must be no voltage on the circuit. If the
probe tip comes in contact with voltage the Over Voltage alert
will sound.
It is necessary to connect the ground lead to a chassis or other
common ground point to accurately measure 2 Ohms or less.
This will eliminate voltage drops within the 20 ft cable and
improve the accuracy.
APPLICATION: If you have a wire bundle and suspect the
wiring may have a short or open, you can connect the tip to
the circuit and check that the resistance is within the expected
limits. If it is, reset the Min/Max by pressing the R button, then
move or wiggle the wire bundle. If a wire has an intermittent
open, you will see a sudden change in the Max reading. Its
exact reading may not be of value as much as the change in
reading. If there is a sudden short in the wire, it will be cap-
tured on the Min reading. Again, it is the sudden change more
than the actual reading that tells you there is a problem with
that wire.
Once you have captured Min/Max data, the data will remain on
the display until a new Min/Max either overrides it or until you
press the R button, which will reset the Min/Max to Average.
Ohms Min/Max is a feature of the Ohm Meter Mode only. It is
not available in Power Probe Hook Mode. To return to Power
Probe Hook Mode, press SEL button once or press the L but-
ton to return to the menu. To return back to Ohm Meter Mode,
follow steps described previously.
HOM 12
12
0
0
Reset
Min/Max
HOM 12
12
12
Page 12

Page 13
IX - Injector Mode
Injector Mode serves two purposes.
First the ability to test the fuel injector driver and second to test
the injector circuit itself.
First, unlike standard Noid lights that require you to discon-
nect the injector harness, The HOOK can be back probed into
the fuel injectors control circuits at any location. Once con-
nected, select the Injector Mode. Now if you have a no start,
crank the vehicle and you will see the LEDs ash and hear the
speaker at the same rate the driver is controlling the injector.
Many vehicles today need to have the injector connected for
the driver to function and are impossible to access. A standard
Noid light will not work as a tester because of these limitations.
The ashing LED’s and audio monitoring of the injector driver
are designed for cranking and lower rpm’s.
Second, the display will indicate the inductive kick voltage of
the injector circuit. This is a direct result of the strength of the
injector coil. When comparing all of the injector inductive kick
voltages, the weak coil or circuit with high resistance will stand
out. Think of this as the quickest injector circuit tester on the
planet, scope like data without the scope.
When the inductive kick voltage exceeds 35V, both red and
green LED’s will ash simultaneously at the rate the injector is
ring based on cranking or idle speed letting you know it is op-
erating. This is not to be confused with a Noid light. If you see
voltage dropping below an expected level or an unexpected
disruption in the audible and visual indicators, you will have the
information as to the condition of that injector or circuit.
Let’s understand how to use this data. No ashing LED’s and
no speaker tone can mean the driver is not working or an open
circuit. LED’s ashing/speaker tone means that at least 35
volts has been measured in the inductive kick. This means the
injector driver is working. Now we can pay attention to the ac-
tual voltage reading. Normal inductive kick voltages vary from
manufacturer to manufacturer. With that said, you can expect
a range from approximately 50 to 80 volts. The important point
here is to compare all the voltage readings from the vehicle’s
injectors. The one that is different from the rest will be revealed.
The lower voltage indicates a weak injector coil or high resis-
tance in the circuit. When cranking the engine it may be neces-
sary to use an extension lead if you do not have a method to
turn the key outside the vehicle
NOTES: Counter mode including pulse width and duty cycle
is not intended for use on fuel injectors. Injector mode will not
provide any usable data on the 12volt supply to the injector. It
is designed to read the fast rapid rise of the inductive kick only.

Page 14
X- COUNTER MODE
a) Duty Cycle/Frequency
Duty Cycle is used for checking Cruise Controls, Idle Air Con-
trol Motors and Fuel Metering Solenoids.
To access Duty Cycle/Frequency from Power Probe Hook Mode:
1. Press SEL once.
2. Press D, 6 times or U, 5 times. It displays COUNT MODE
DUTY CYC
3. Press SEL once.
b) Positive Pulse Width/Frequency
Use Positive Pulse Width to check the time a fuel injector is
ON, which is the time the ECM/ECU transistor is being pulled
to ground. On time. In seconds.
To access Pulse Width/Frequency from Power Probe Hook Mode:
1. Press SEL once.
2. Press D, 6 times.
3. Press R, once.
4. Press SEL once.
c) Negative Pulse Width/Frequency
Use Negative Pulse Width to check the time a fuel injector is
OFF. Off time. In seconds
To access Negative Pulse Width/Frequency from
Power Probe Hook Mode:
1. Press SEL once.
2. Press D, 6 times.
3. Press R, twice
4. Press SEL once.
d) Pulse Counter
Counter can be used to check Knock Sensors, Wheel Speed
Sensors, Cam Sensors, Crank Sensors and other similar de-
vices where number of counts may be valuable. The maximum
pulse rate for the pulse counter is 5 kHz.
To access Pulse Counter from Power Probe Hook Mode:
1. Press SEL once.
2. Press D, 6 times or U, 5 times.
3. Press R, three times. It displays COUNTER.
4. Press SEL once.
Counter Mode is a passive mode. The (+) Power and (–) Power buttons are not active so dynamic circuit testing cannot be
performed. This means, no Power will be activated to the probe tip even when you press the Power buttons. Frequency
Counter is a feature of Counter Mode. In Counter Mode you can check Pulse Count, Duty Cycle and both Positive and
Negative Pulse Widths. These extra features are useful for measuring signals that are used for sensors, injectors and
other signal related components. Each feature will display the selected meter on the top of the display and frequency on
the bottom except in Pulse Count.
O
M
OE
D
CU T
+U
PW
HT
N
L
P
+W14
3s
100HZ
2
u
P
+W14
3s
100HZ
2
u
U
DTY%
0
100HZ
5

Page 15
XI - VOLTAGE REFERENCE SUPPLY MODE:
Voltage Reference Supply Mode is an active mode but it does
not function the same as the normal Power Probe Hook Mode
activation. It has selectable voltage output to the probe tip that
is limited to 20 mA.
To access Voltage Reference Supply Mode from Power
Probe Hook Mode:
1. Press SEL once.
2. Press D, 7 times or U, 4 times. The display shows
VOLTAGE REFERENCE.
3. Press SEL once.
4. Press U repeatedly to increase the voltage on the probe tip
and press D repeatedly to decrease voltage on the
probe tip.
5. Press R once to turn off reference voltage at the probe tip
The reference voltage peaks at 5 volts max.
APPLICATION: This can be useful when checking the wiring to
an ECM/ECU. After you have checked out your sensor using
the voltmeter and or ohmmeter, if there is still a problem, you
can simulate the voltages that are put out by sensors in order
to verify the wiring going to the ECM/ECU. Using an OBD scan-
ner you can verify the results out of the ECM/ECU. You can
select voltages from 0 to 5 VDC in .5-volt increments (Default
is 0 volts)
The actual voltage on the tip will be displayed on the top of the
screen and the set point voltage displayed on the bottom. There
is a Set Point Voltage Alarm in case the circuit connected to the
probe tip forces the voltage above or below the set point voltage
by .1 volts. This is separate from the Over Voltage Alarm that
trips at >99.9 Volts. The Set Point Voltage alarm will emit a short
tone and you will notice the difference from the actual voltage at
XII - CONTRAST:
If the contrast between the characters and the display
need adjusting you can do this in CONTRAST.
To access Contrast from Power Probe Hook Mode:
1. Press SEL once.
2. Press U, 3 times. The display shows CONTRAST.
3. Press R or L to the desired Contrast.
4. Press SEL once.
SOC N RT
16
T
A
Set Point voltage alarm
sounds.Remove and check
circuit for shorts or other
malfunction.
Actual voltage
on tip
Set point volts
.2v volts from
Set point volts
Output volts
Set point volts
not the same as
output voltage
the Set Point
voltage alarm
will sound.
{ }
2
O0
VL S
VE
R
T
F2 0
1
O8
VL S
VE
R
T
F2 0

Page 16
Save Preferences: If you have certain preferences you
would like to save because you use them often. You can
select SAVE PREF. All preferences will default to these
saved preferences on Start-Up.
To access Save Preferences from Power Probe Hook Mode:
1. Press SEL once.
2. Press U, 2 times.
3. Press R, once.
4. Press SEL.
Default Reset: If you want to reset the Default to factory
presets. You can use DEFAULTSET.
To access Default Reset from Power Probe Hook Mode:
1. Press SEL once.
2. Press U, 2 times.
3. Press R, 3 times.
4. Press SEL.
XIII - SAVE PREFERENCES & DEFAULT SETTINGS:
A
SVP
EREF
ESY
ESY
ED FT
ASETUL

Page 17
Safety Information: ALWAYS USE SAFETY GLASSES, OR EYE PROTECTION.
There are a number of safety features built in to the Power Probe Hook to protect the tool, the test circuit and you! Below
is a list and brief description of all the safety features.
1. Circuit Breaker:
Shuts off current to the tip if set value is exceeded. Plays tone specic to Circuit Breaker trip. In momentary you must
re-energize the Power Up buttons, in Latch Mode and Pulse Mode, power re-energizes automatically. Only available in
Power Probe Hook Mode (HookM) and Power Plus Mode.
2. Thermal Overload Trip feature
Powering up loads generates heat within a circuit depending upon the load and the duration. The Power Probe Hook has
built in calculated thermal protection. This means the higher the load and longer the duration, the higher the Power Probe
Hook will assume its internal temperature. The Power Probe Hook can drive a 25 amp load continuously but can only
drive a 65 amp load for about 8 seconds. If the thermal overload is tripped, the power will be terminated and the thermal
overload warning, “OVER TEMP” will appear on the display with a count down bar that will countdown for 10 seconds. You
will hear a tone specic to Thermal Overload. If the load is immediately repowered again after the Thermal Overload, the
run time will continue to shorten before Thermal Overload triggers again.
3. Overvoltage Alarm
If the voltage on the tip exceeds 99.9 Volts AC or DC the display will read Overvoltage and you will hear a specic tone.
The Hook has been rated for + or - 500VDC maximum to protect the tool. Available in all modes.
4. Sleep Mode
Sleep Mode is designed to preserve the life of your Display Back Light. Sleep Mode only works in Power Probe Hook
Mode when not being used. If you leave your meter in any other mode the Hook will stay active. The life of the Backlight
is 10,000 hours. Leaving the Hook Powered Up in any mode other than Power Probe Hook Mode will subtract from the
overall life and is not recommended. If you have powered up the Hook and it is sitting in Power Probe Hook Mode with no
action being taken for 10 minutes, your Hook will enter into Sleep Mode. At this time the Flashlight and Backlight will be
turned off and SLEEPING will appear on the display. If the tip senses a change or any button is pressed, the Hook will
wake up. It is ok to press any button when in sleep mode to wake it up. If a button is pressed when asleep no action will
be taken for the button pressed at that time only. The next press will be active. Available only in Power Probe Hook Mode.
5. Set Point Voltage Alarm
In Voltage Reference Mode only, if the voltage on the tip is different from the set voltage, a tone will sound.
6. Reverse Polarity Hook Up
The Hook has built in protection against reversing the polarity of the Hook Up Clips.
7. Fuse protection
The Power Probe Hook Up Clip set has built in fuse protection. Never try to connect your Power Probe Hook to a battery
without the proper supplied connector. Fire can occur! If the Hook Up Clip set is in proper working order, a light can be
seen glowing within the side of the connector body. If your Power Probe Hook is not powering up, check to see that the
light is lit. If not and the polarity is correct, you need to replace your Hook Up Clip set and have your Power Probe Hook
inspected for possible damage before using again.
The Ground Cable also has a fuse protection in the event that the Ground Cable comes in contact with a positive battery
source or it exceeds 25 amps continuous when using the Ground Cable as ground source. It has a replaceable 20mm
x 5.5 mm automotive fuse. To replace fuse, pry out fuse cover from Ground Cable connector body, remove old fuse and
insert new. Press back into Ground Cable connector body.
Safety

Page 18
• Don’t forget to warranty your product by going to www.powerprobe.com/warranty/ or ll out & mail in the warranty card.
• Power Probe Hook Mode is Auto Selecting and Auto Ranging. This means you don’t have to gure out which button to
press to get Volts or Ohms and Amps will display when you press the power button.
• Take the time to get very familiar with the preference line of the Hook. (See section III-a)
The symbols at the top of the display after boot up are the default preference values. If you change the preference values,
the values at the top will change accordingly. This way you always know how your Hook will operate.
• Battery voltage will always be displayed on the lower line in Power Probe Hook Mode when the tip is unloaded. The rst
thing you must do after power up is look at the battery voltage and decide if it is within operational voltage of the Hook,
9-48 VDC. If the Hook doesn’t power up, check your battery rst, then make sure your battery clips are on the correct
polarity and the LED in the battery clips is lit.
• The menu system is like a corridor. When you rst power up, you will be put into the room Power Probe Hook Mode.
You can enter into to the corridor by pressing the SELECT button. You can move up and down the corridor using the UP
or DOWN ARROW buttons to reach different doors. You can enter any room along the way by using the RIGHT ARROW
button. You can exit these other rooms by pressing SELECT or the LEFT ARROW button.
• All preferences will return to default on the next power up unless you use the Save Preferences function. If you like
where you have set your preferences and want to save them, use the Save Preferences Option. (see section XII)
• If you don’t like your saved settings, use Default reset to restore factory settings. (see section XII)
• Min/ Max are NOT found in Power Probe Hook Mode. It is only found in Volt Meter, Ohm Meter and Power Plus Modes.
• There is an Arc Detect function that is designed to preserve your tip and circuit. It is active in Power Probe Hook Mode
but is not in Power Plus Mode.
• Components that depend on arcs such as horns and motors can be affected by the Arc Detect circuit. Most horns and
motors should not be affected but depending on the component and its age, there may be interference caused by Arc
Detect. If you intend to power up something like a motor or horn you can go directly to Power Plus Mode and apply full
power. Caution must be used on high current devices. Always use the Power Probe Hook safely as described in the
manual.
• The larger the current draw the less run time before Thermal Overload Protection is activated. It is not a sign of com-
ponent failure. The Hook is protecting itself. The longer the cool down time the longer the subsequent run time and vise
versa. Thermal overload will shut down power for 10 seconds if triggered. The Hook can run 25 amps continuously.
• There are 4 types of meters in Counter Mode including a simple pulse counter, positive and negative pulse widths and
duty cycle. All but pulse counter display frequency with the selected meter.
• There can be AC signals in DC systems. If you want to measure them, lower your AC threshold setting to the lowest set-
ting to display a peak to peak voltage when an AC voltage greater than that setting becomes present on the tip. Increase
the sensitivity to only detect higher levels of AC voltage when present. AC Peak to Peak will override Volt Meter when in
Power Probe Hook Mode. Set the AC Threshold preference to the highest setting if you nd that unimportant AC signals
are interfering with your DC voltage readings.
• This device is NOT intended for AC voltage measurements other than those in DC systems from 12-48VDC.
AC Peak to Peak and Frequency are the same function.
• The speaker can only be turned on and off in Power Probe Hook Mode.
• The Red and Green LED’s will not detect Voltage Drop unless in Power Probe Hook Mode.
• You may have to adjust your Voltage Drop preferences to get the Red/ Green LED’s to work as a Voltage Drop Meter.
• When the 3 wire continuity plug is inserted into the jack, the Red/Green LED’s are now dedicated to the Continuity Tes-
ter. They will respond to either the red or green wire respectively when touched to the black. You can still use the Hook
normally to power up or read voltage, ohms or amps.
• The auxiliary ground has a replaceable 25 amp fuse. Always touch it to the tip for continuity before using it to make sure
the fuse is not blown.
Facts & Tips

Page 19
Product Specications
Min Operating Voltage........................... 12 VDC
Max Operating Voltage ......................... 48 VDC
Voltage Measurement............................ 0-99.9 VDC/ VAC
Ohms Measurement.............................. .001 Ohms – 15 Mega Ohms
Amps Measurement .............................. .001 Amps – 99.9 Amps
Max Continuous Load............................ 25 Amps
Max Intermittent Load............................ 65 Amps for 8 Sec.
Hook Up Cables .................................... 10 Gauge
Input Impedence ................................... 1 Mega Ohm
Specs...
Operating Temperature.......................... -10C to 50C (14F to 122F)
Storage Temerature............................... -40C to 65C (-40F to 149F)
Humidity................................................. 95% RH 10C to 30C (50F to 86F)
............................................................... 75% RH 30C to 40C (86F to 104F)
............................................................... 45% RH 40C to 50C (104F to 122F)
Environmental...

Page 20
Notes:_____________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
__________________________________________________________________________________________
Table of contents