PowerBoss 30220 User manual

Manual No. 199910GS Rev. B (02/12/2007)
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON,WISCONSIN, U.S.A.
Operator’s Manual
Manual del Operario
Questions? Help is just a moment away!
Preguntas? La ayuda es justa un momento lejos!
Call: Generator Helpline / Llamada: Generador Helpline
1-800-743-4115 M-F 8-5 CT
BRIGGSandSTRATTON.COM
PowerBOSS™ is a trademark of Briggs & Stratton Power Products.
PowerBOSS™ es una marca registrada de Briggs & Stratton Power Products.
Model / Modelo
030220
(7000W)

2
PowerBOSS™ 7000W Portable Generator SAFETY RULES
TABLE OF CONTENTS
Safety Rules. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4
Know Your Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
EQUIPMENT
DESCRIPTION
Read this manual carefully and become familiar
with your generator. Know its applications, its
limitations and any hazards involved.
This generator is an engine–driven, revolving field,
alternating current (AC) generator. It was designed to
supply electrical power for operating compatible electrical
lighting, appliances, tools and motor loads.The generator’s
revolving field is driven at about 3,600 rpm by a twin-
cylinder engine.
CAUTION! DO NOT exceed the generator’s
wattage/amperage capacity. See “Don’t Overload
Generator”.
Every effort has been made to ensure that information in
this manual is accurate and current. However, we reserve
the right to change, alter or otherwise improve the product
and this document at any time without prior notice.
The Emission Control System for this generator is
warranted for standards set by the Environmental
Protection Agency and the California Air Resources Board.
For warranty information refer to the engine operator’s
manual.
SAFETY RULES
This is the safety alert symbol. It is used to
alert you to potential personal injury hazards.
Obey all safety messages that follow this
symbol to avoid possible injury or death.
The safety alert symbol ( ) is used with a signal word
(DANGER, CAUTION,WARNING), a pictorial and/or a
safety message to alert you to hazards. DANGER indicates
a hazard which, if not avoided, will result in death or
serious injury. WARNING indicates a hazard which, if not
avoided, could result in death or serious injury.
CAUTION indicates a hazard which, if not avoided, might
result in minor or moderate injury. CAUTION,whenused
without the alert symbol, indicates a situation that could
result in equipment damage. Follow safety messages to
avoid or reduce the risk of injury or death.
Hazard Symbols and Meanings
The engine exhaust from this product contains
chemicals known to the State of California to cause
cancer, birth defects, or other reproductive harm.
WARNING
SAVE THESE INSTRUCTIONS
Copyright © 2007 Briggs & Stratton Power Products
Group, LLC. All rights reserved. No part of this material
may be reproduced or transmitted in any form by any
means without the express written permission of Briggs &
Stratton Power Products Group, LLC.
Fire
Explosion
To x i c F u m e s Hot Surface
Electrical Shock
Kickback
Operator’s Manual

3
SAFETY RULES 7000W Portable Generator PowerBOSS™
3
•ThisgeneratordoesnotmeetU.S.CoastGuardRegulation
33CFR-183 and should not be used on marine applications.
•FailuretousetheappropriateU.S.CoastGuardapproved
generator could result in death or serious injury and/or
property damage.
WARNING
•Whenusinggeneratorforbackuppower,notifyutility
company. Use approved transfer equipment to isolate
generator from electric utility.
•Useagroundfaultcircuitinterrupter(GFCI)inanydampor
highly conductive area, such as metal decking or steel work.
•DONOTtouchbarewiresorreceptacles.
•DONOTusegeneratorwithelectricalcordswhichareworn,
frayed, bare or otherwise damaged.
•DONOToperategeneratorintherainorwetweather.
•DONOThandlegeneratororelectricalcordswhilestanding
in water, while barefoot, or while hands or feet are wet.
•DONOTallowunqualifiedpersonsorchildrentooperateor
service generator.
Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
•OperategeneratorONLYoutdoors.
•Installabatteryoperatedcarbonmonoxidealarmnearthe
bedrooms.
•Keepexhaustgasfromenteringaconfinedareathrough
windows, doors, ventilation intakes or other openings.
•DONOToperategeneratorinsideanybuildingorenclosure
(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
WARNING
WHEN ADDING OR DRAINING FUEL
•TurngeneratorOFFandletitcoolatleast2minutesbefore
removing fuel cap. Loosen cap slowly to relieve pressure in
tank.
•Fillordrainfueltankoutdoors.
•DONOToverfilltank.Allowspaceforfuelexpansion.
•Waitforspilledfueltoevaporatebeforestartingengine.
•Keepfuelawayfromsparks,openflames,pilotlights,heat,and
other ignition sources.
•DONOTlightacigaretteorsmoke.
WHEN STARTING EQUIPMENT
• Ensure spark plug, muffler, fuel cap and air cleaner are in place.
•DONOTcrankenginewithsparkplugremoved.
WHEN OPERATING EQUIPMENT
•DONOTtipengineorequipmentatanglewhichcausesfuel
to spill.
•Thisgeneratorisnotforuseinmobileequipmentormarine
applications.
WHEN TRANSPORTING OR REPAIRING
EQUIPMENT
•Transport/repairwithfueltankEMPTYorwithfuelshutoff
valve OFF.
•Disconnectsparkplugwire.
WHEN STORING FUEL OR EQUIPMENT WITH FUEL
IN TANK
•Storeawayfromfurnaces,stoves,waterheaters,clothes
dryers or other appliances that have pilot light or other
ignition source because they can ignite fuel vapors.
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WARNING

4
PowerBOSS™ 7000W Portable Generator SAFETY RULES
•DONOTtamperwithgovernedspeed.Generatorsupplies
correct rated frequency and voltage when running at governed
speed.
•DONOTmodifygeneratorinanyway.
Excessively high operating speeds increase risk of injury
and damage to generator.
Excessively low speeds impose a heavy load.
CAUTION
•See“Don’tOverloadGenerator”.
•Startgeneratorandletenginestabilizebeforeconnecting
electrical loads.
•ConnectelectricalloadsinOFFposition,thenturnONfor
operation.
•TurnelectricalloadsOFFanddisconnectfromgenerator
before stopping generator.
Exceeding generators wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION
•Usegeneratoronlyforintendeduses.
•Ifyouhavequestionsaboutintendeduse,askdealerorcall
1-800-743-4115.
•Operategeneratoronlyonlevelsurfaces.
•DONOTexposegeneratortoexcessivemoisture,dust,dirt,
or corrosive vapors.
•DONOTinsertanyobjectsthroughcoolingslots.
•Ifconnecteddevicesoverheat,turnthemoffanddisconnect
them from generator.
•Shutoffgeneratorif:
-electrical output is lost;
-equipment sparks, smokes, or emits flames;
-unit vibrates excessively.
Improper treatment of generator can damage it and
shorten its life.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TOYOUR
GENERATOR
•Disconnectthesparkplugwirefromthesparkplugandplace
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
•Useapprovedsparkplugtester.
•DONOTcheckforsparkwithsparkplugremoved.
Unintentional sparking can result in fire or
electric shock.
WARNING
•DONOTtouchhotsurfacesandavoidhotexhaustgases.
•Allowequipmenttocoolbeforetouching.
•Keepatleast5ft.(152cm)clearanceonallsidesofgenerator
including overhead.
•CodeofFederalRegulation(CFR)Title36Parks,Forests,and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
•Whenstartingengine,pullcordslowlyuntilresistanceisfelt
and then pull rapidly to avoid kickback.
•NEVERstartorstopenginewithelectricaldevicespluggedin
and turned on.
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains could
result.
WARNING

5
FEATURES 7000W Portable Generator PowerBOSS™
KNOW YOUR GENERATOR
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
120 Volt AC, 20 Amp, Duplex Receptacles — May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical, lighting,
appliance, tool and motor loads.
120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical, lighting, appliance, tool and motor loads.
Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
Choke Rod — Used when starting a cold engine.
Circuit Breakers (AC) — The 120 Volt AC, 20A duplex
receptacles are provided with "push to reset" circuit
breakers to protect the generator against electrical overload.
Data Tag — Provides model, revision and serial number of
generator. Please have these readily available when calling
for assistance.
Engine Switch — Set this switch to "On" before using
recoil starter. Set switch to "Off" to switch off engine.
Fuel Tank — Capacity of seven (7) U.S. gallons.
Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
Hour Meter — Displays and records how many hours
your generator has run (up to 9,999.9).
Oil Fill Cap — Check and fill engine with oil here.
Recoil Starter — Used to start the engine.
Rocker Switch Circuit Breaker — The 120/240 Volt
AC, 30A locking receptacle is provided with a rocker
switch circuit breaker to protect the generator against
electrical overload.This switch also controls all receptacles.
Spark Arrester Muffler — Exhaust muffler lowers
engine noise and is equipped with a spark arrester screen.
Fuel Tank
Air Cleaner Engine Switch
120/240 Volt AC,
30 Amp Receptacle
Circuit Breakers (AC)
Choke Rod
Recoil Starter
Grounding Fastener Oil Fill Cap
120 Volt AC, 20 Amp
Duplex Receptacles
Data Tag
Rocker Switch
Circuit Breaker
Hour Meter
Spark Arrester Muffler

6
PowerBOSS™ 7000W Portable Generator ASSEMBLY
ASSEMBLY
Yo u r g e n e r a t o r r e q u i re s s o m e a s s e m b l y a n d i s r e a d y f o r
use after it has been properly serviced with the
recommended oil and fuel.
If you have any problems with the assembly of your
generator, please call the generator helpline at
1-800-743-4115.Ifcallingforassistance,pleasehavethe
model, revision, and serial number from the data tag available.
See “KnowYour Generator” for data tag location.
Unpacking the Generator
1. Set the carton on a rigid flat surface.
2. Open carton completely by cutting each corner from
top to bottom.
3. Remove everything from carton except generator.
4. Leave generator on carton to install wheel kit.
Install Wheel Kit
The wheel kit is designed to greatly improve the portability
of your generator.
NOTE: Wheel kit is not intended for over-the-road use.
Yo u w i l l n e e d t h e f o l l o w i n g t o o l s t o i n s t a l l t h i s w h e e l k i t :
•13mmsocketwrench
•13mmopenendwrench
•Pliers
•Safetyglasses
Refer to Figure 1 and install the wheel kit as follows:
1. Tip generator so that engine end is up.
2. Slide axle through both mounting brackets.
3. Slide a wheel over the axle.
NOTE: Be sure to install both wheels with the air
pressure valve on the outboard side.
4. Place a washer on axle and then place an e-ring in axle
groove.
5. Install e-ring with pliers, squeezing from top of e-ring
to bottom of axle.
Support Leg
Axle
20mm Cap Screw
Wheel
E-Ring
Flat Washer
Lock Nut
Lock Nut
Handle Pin
Handle
Flat Washers
45 mm Cap Screw Nylon Washers
Figure 1 — Install Wheel Kit
• Always wear eye protection when installing/removing e-rings.
E-rings can cause eye injury.
E-rings can spring back and become airborne
when installing or removing.
CAUTION

7
ASSEMBLY 7000W Portable Generator PowerBOSS™
6. Repeat step 3 thru 5 to secure second wheel.
7. Tip generator so that engine side is down.
8. Attach support leg with M8 x 20 mm cap screws and
M8 lock nuts.
9. Attach handles to handle brackets on generator frame,
as shown in Figure 1, with M8 x 45 mm capscrews, flat
washers, nylon washers, and M8 lock nuts.
NOTE: Be sure to install the nylon washers between the
handle brackets on the generator frame and the brackets
on the handle assembly.
10. Return generator to normal operating position (resting
on wheels and support leg).
11. Loop handle pins to generator frame as shown in
Figure 1. Raise handles and insert handle pins to move
generator.
12. Check each fastener to ensure it is secure and the
tires are inflated between 15-40 PSI.
BEFORE STARTING THE
ENGINE
Add Engine Oil
•Placegeneratoronalevelsurface.
•Refertoengineoperator’smanualandfollowoil
recommendations and instructions.
NOTE: Check oil often during engine break–in. Refer to
engine operator’s manual for recommendations.
NOTE: The alternator assembly rotates on a prelubricated
and sealed ball bearing that requires no additional
lubrication for the life of the bearing.
Add Fuel
NOTE: This gasoline engine is certified to operate on
gasoline. Exhaust Emission Control System: EM (Engine
Modifications).
1. Use clean, fresh, regular UNLEADED gasoline with a
minimum of 87 octane. DO NOT use fuel which
contains Methanol. DO NOT mix oil with fuel.
2. Clean area around fuel fill cap, remove cap.
3. Slowly add regular unleaded fuel to fuel tank. Be careful
not to overfill.Allow at least 1.5" of tank space for fuel
expansion (Figure 2).
4. Install fuel cap and let any spilled fuel evaporate before
starting engine.
CAUTION
•Refertoenginemanualforoilfillinformation.
•Damagetoequipmentresultingfromfailuretofollowthis
instruction will void warranty.
Any attempt to crank or start the engine before it has
been properly filled with the recommended oil will result
in equipment failure.
WHEN ADDING FUEL
•TurngeneratorOFFandletitcoolatleast2minutesbefore
removing fuel cap. Loosen cap slowly to relieve pressure in tank.
•Fillfueltankoutdoors.
•DONOToverfilltank.Allowspaceforfuelexpansion.
•Waitforspilledfueltoevaporatebeforestartingengine.
•Keepfuelawayfromsparks,openflames,pilotlights,heat,and
other ignition sources.
•DONOTlightacigaretteorsmoke.
Fuel and its vapors are extremely flammable and
explosive.
Fire or explosion can cause severe burns or
death.
WARNING
Fuel
Tan k
1.5” Air Space
Figure 2 - Fuel Expansion

8
PowerBOSS™ 7000W Portable Generator OPERATION
USING THE GENERATOR
System Ground
The generator has a system ground that connects the
generator frame components to the ground terminals on
the AC output receptacles.The system ground is connected
to the AC neutral wire (see “Equipment Description”,
earlier in this manual).
Special Requirements
There may be Federal or State Occupational Safety and
Health Administration (OSHA) regulations, local codes, or
ordinances that apply to the intended use of the generator.
Please consult a qualified electrician, electrical inspector, or
the local agency having jurisdiction.
•Insomeareas,generatorsarerequiredtoberegistered
with local utility companies.
•Ifthegeneratorisusedataconstructionsite,theremay
be additional regulations which must be observed.
Connecting to a Building’s Electrical
System
Connections for standby power to a building’s electrical
system must be made by a qualified electrician.The
connection must isolate the generator power from utility
power, and must comply with all applicable laws and
electrical codes.
Generator Location
Generator Clearance
Place generator in a well ventilated area, which will allow
for removal of deadly exhaust gas. DO NOT place
generator where exhaust gas could accumulate and enter
inside or be drawn into a potentially occupied building.
Ensure exhaust gas is kept away from any windows, doors,
ventilation intakes or other openings that can allow exhaust
gas to collect in a confined area (Figure 3). Prevailing winds
and air currents should be taken into consideration when
positioning generator.
•Whenusinggeneratorforbackuppower,notifyutility
company. Use approved transfer equipment to isolate
generator from electric utility.
•Useagroundfaultcircuitinterrupter(GFCI)inanydampor
highly conductive area, such as metal decking or steel work.
•DONOTtouchbarewiresorreceptacles.
•DONOTusegeneratorwithelectricalcordswhichareworn,
frayed, bare or otherwise damaged.
•DONOToperategeneratorintherainorwetweather.
•DONOThandlegeneratororelectricalcordswhilestanding
in water, while barefoot, or while hands or feet are wet.
•DONOTallowunqualifiedpersonsorchildrentooperateor
service generator.
Generator produces powerful voltage.
Failure to isolate generator from power utility
can result in death or injury to electric utility
workers due to backfeed of electrical energy.
WARNING
Figure 3 — Generator Clearance
Typical Generato r S h o w n
•Keepatleast5ft.(152cm)clearanceonallsidesofgenerator
including overhead.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING

9
OPERATION 7000W Portable Generator PowerBOSS™
OPERATING THE
GENERATOR
Starting the Engine
Disconnect all electrical loads from the generator. Use the
following start instructions:
1. Make sure unit is on a level surface.
IMPORTANT: Failure to start and operate unit on a level
surface will cause the unit not to start or shut down during
operation.
2. Turn the fuel valve to the “On” position (Figure 4).The
fuel valve handle should be vertical (pointing toward
the ground) for fuel to flow.
3. Start engine according to instructions given in the
engine operator’s manual.
NOTE: If engine starts after 3 pulls but fails to run, or if
unit shuts down during operation, make sure unit is on a
level surface and check for proper oil level in crankcase.
This unit may be equipped with a low oil protection device.
See engine operator’s manual.
Connecting Electrical Loads
•Letenginestabilizeandwarmupforafewminutesafter
starting.
•Pluginandturnonthedesired120and/or240VoltAC,
single phase, 60 Hz electrical loads.
•DONOTconnect240Voltloadstothe120Voltduplex
receptacles.
•DONOTconnect3–phaseloadstothegenerator.
•DONOTconnect50Hzloadstothegenerator.
•DO NOT OVERLOAD THE GENERATOR. See
“Don’t Overload Generator”.
Figure 4 — FuelValve
Fuel Valve is shown
in “On” position
•Whenstartingengine,pullcordslowlyuntilresistanceisfelt
and then pull rapidly to avoid kickback.
•NEVERstartorstopenginewithelectricaldevicespluggedin
and turned on.
Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains could
result.
WARNING
•DONOTtouchhotsurfacesandavoidhotexhaustgases.
•Allowequipmenttocoolbeforetouching.
•Keepatleast5ft.(152cm)clearanceonallsidesofgenerator
including overhead.
•CodeofFederalRegulation(CFR)Title36Parks,Forests,and
Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING
•See“Don’tOverloadGenerator”.
•Startgeneratorandletenginestabilizebeforeconnecting
electrical loads.
•ConnectelectricalloadsinOFFposition,thenturnONfor
operation.
•TurnelectricalloadsOFFanddisconnectfromgenerator
before stopping generator.
Exceeding generator’s wattage/amperage capacity can
damage generator and/or electrical devices connected
to it.
CAUTION

10
PowerBOSS™ 7000W Portable Generator OPERATION
Stopping the Engine
1. Turn OFF and unplug all electrical loads from
generator panel receptacles. NEVER start or stop engine
with electrical devices plugged in and turned ON.
2. Let engine run at no-load for several minutes to
stabilize internal temperatures of engine and generator.
3. Turn engine off according to instructions given in the
engine operator’s manual.
4. Move fuel valve to “Off” position.
RECEPTACLES
120/240 Volt AC, 30 Amp, Locking
Receptacle
Use a NEMA L14–30 (National Electrical Manufacturers
Association) plug with this receptacle. Connect a 4–wire
cord set rated for 250Volt AC loads at 30 Amps (or
greater) (Figure 5).You can use the same 4–wire cord if you
plan to run a 120 Volt load.
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 3,500 watts of power at
29.1 Amps for 120 Volts; 7,000 watts of power (7.0 kW) at
29.1 Amps for 240 Volts.The outlet is protected by a
rocker switch circuit breaker.
120 Volt AC, 20 Amp, Duplex
Receptacle
Each receptacle (Figure 6) is protected against overload by
a push–to–reset circuit breaker.
Use each receptacle to operate 120Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] combined with high humidity), your generator
may experience icing of the carburetor and/or the
crankcase breather system.To reduce this problem, you
need to perform the following:
1. Make sure generator has clean, fresh fuel.
2. Open fuel valve (turn valve to open position).
3. Use SAE 5W-30 oil (synthetic preferred, see engine
operator’s manual).
4. Check oil level daily or after every eight (8) hours of
operation.
5. Maintain generator following “Maintenance Schedule”
in engine operator’s manual.
6. Shelter unit from elements.
•NEVERattempttopoweradevicerequiringmoreamperage
than generator or receptacle can supply.
•DONOToverloadthegenerator.See“Don’tOverload
Generator”.
Receptacles may be marked with rating value greater
than generator output capacity.
CAUTION
Figure 5 — 120/240 Volt AC, 30 Amp Receptacle
4-Wire Cord Set
240V
120V 120V
W (Neutral)
X (Hot)
Y (Hot)
NEMA L14-30 Ground (Green)
Figure 6 — 120Volt AC, 20 Amp, Duplex Receptacle

11
OPERATION 7000W Portable Generator PowerBOSS™
Creating a Temporary Shelter
1. In an emergency, use the original shipping carton.
2. Cut off top carton flaps and one long side of carton to
expose muffler side of unit. If required, tape up other
sides of carton to fit over generator as shown in
Figure 7.
NOTE: If required, remove wheel kit to fit carton over
generator as shown in Figure 7.
3. Cut appropriate slots to access receptacles of unit.
4. Face exposed end away from wind and elements.
5. Locate generator as described in the section
“Generator Location”. Keep exhaust gas from entering
a confined area through windows, doors, ventilation
intakes or other openings.
6. Start generator as described in the section “Starting
the Engine”, then place carton over generator. Keep at
least 5 ft. (152 cm) clearance on all sides of generator
including overhead with shelter in place.
7. Remove shelter when temperatures are above 40°F
[4°C].
8. Turn engine OFF and let cool two (2) minutes before
refueling.Wipe up any spilled fuel.
Creating a Permanent Shelter
1. Build a structure that will enclose three sides and the
top of the generator, making sure muffler side of
generator is exposed.
NOTE: Structure should hold enough heat created by the
generator to prevent icing problem.
2. DO NOT enclose generator any more than shown in
Figure 7.
NOTE: If a wheel kit is installed on the generator, enlarge
shelter accordingly.
3. Follow steps 3 through 8 as described previously in
“Creating a Temporary Shelter”.
Figure 7 — Permanent Cold Weather Shelter
Wind
•OperategeneratorONLYoutdoors.
•Installabatteryoperatedcarbonmonoxidealarmnearthe
bedrooms.
•Keepexhaustgasfromenteringaconfinedareathrough
windows, doors, ventilation intakes or other openings.
•DONOToperategeneratorinsideanybuildingorenclosure
(even if doors or windows are open), including the generator
compartment of a recreational vehicle (RV).
Running generator gives off carbon monoxide,
an odorless, colorless, poison gas.
Breathing carbon monoxide can cause nausea,
fainting or death.
WARNING
•DONOTtouchhotsurfacesandavoidhotexhaustgases.
•Allowequipmenttocoolbeforetouching.
•Keepatleast5ft.(152cm)clearanceonallsidesofgenerator
including overhead.
•Removeshelterwhentemperaturesareabove40°F[4°C].
Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.
WARNING

12
PowerBOSS™ 7000W Portable Generator OPERATION
DON’T OVERLOAD
GENERATOR
Capacity
Yo u m u s t m a k e s u r e yo u r g e n e r a t o r c a n s u p p l y e n o u g h
rated (running) and surge (starting) watts for the items you
will power at the same time. Follow these simple steps:
1. Select the items you will power at the same time.
2. Total the rated (running) watts of these items.This is
the amount of power your generator must produce to
keep your items running. See Figure 8.
3. Estimate how many surge (starting) watts you will
need. Surge wattage is the short burst of power
needed to start electric motor-driven tools or
appliances such as a circular saw or refrigerator.
Because not all motors start at the same time, total
surge watts can be estimated by adding only the
item(s) with the highest additional surge watts to the
total rated watts from step 2.
Example:
To t a l R a t e d ( R u n n i n g ) Wa t t s = 3 0 7 5
Highest Additional Surge Watts = 1800
To t a l G e n e r a t o r O u t p u t R e q u i r e d = 4 8 7 5
Power Management
To p r o l o n g t h e l i f e o f y o u r g e n e r a t o r a n d a t t a c h e d d e v i c e s ,
it is important to take care when adding electrical loads to
your generator.There should be nothing connected to the
generator outlets before starting its engine.The correct
and safe way to manage generator power is to sequentially
add loads as follows:
1. With nothing connected to the generator, start the
engine as described in this manual.
2. Plug in and turn on the first load, preferably the largest
load you have.
3. Permit the generator output to stabilize (engine runs
smoothly and attached device operates properly.
4. Plug in and turn on the next load.
5. Again, permit the generator to stabilize.
6. Repeat steps 4 and 5 for each additional load.
NEVER add more loads than the generator capacity.Take
special care to consider surge loads in generator capacity,
as described above.
*Wattages listed are approximate only. Check tool or
appliance for actual wattage.
Tool or Appliance Rated (Running)
Watts
Additional Surge
(Starting) Watts
Window Air
Conditioner
1200 1800
Refrigerator 800 1600
Deep Freezer 500 500
Television 500 -
Light (75 Watts) 75 -
3075 Total
Running Watts
1800 Highest
Surge Watts
Tool or Appliance
Rated*
(Running)
Watts
Additional
Surge
(Starting)
Watts
Essentials
Light Bulb -75 watt
75
-
Deep Freezer
500
500
Sump Pump
800
1200
Refrigerator/Freezer -18 Cu. Ft.
800
1600
Water Well Pump -1/3 HP
1000
2000
Heating/Cooling
Window AC -10,000 BTU
1200
1800
Window Fan
300
600
Furnace Fan Blower -1/2 HP
800
1300
Kitchen
Microwave Oven -1000 Watt
1000
-
Coffee Maker
1500
-
Electric Stove -Single Element
1500
-
Hot Plate
2500
-
Family Room
DVD/CD Player
100
-
VCR
100
-
Stereo Receiver
450
-
Color Television -27”
500
-
Personal Computer w/17” monitor
800
-
Other
Security System
180
-
AM/FM Clock Radio
300
-
Garage Door Opener -1/2 HP
480
520
Electric Water Heater -40 Gallon
4000
-
DIY/Job Site
Quartz Halogen Work Light
1000
-
Airless Sprayer -1/3 HP
600
1200
Reciprocating Saw
960
960
Electric Drill -1/2 HP
1000
1000
Circular Saw -7 1/4”
1500
1500
Miter Saw -10”
1800
1800
Table Planer -6”
1800
1800
Table Saw/Radial Arm Saw -10”
2000
2000
Air Compressor -1-1/2 HP
2500
2500
Figure 8 - Wattage Reference Chart

13
MAINTENANCE 7000W Portable Generator PowerBOSS™
SPECIFICATIONS
Starting Wattage . . . . . . . . . . . . . . . . . . . . 12,000 Watts
Wattage . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7,000 Watts
AC Load Current
At 120 Volts . . . . . . . . . . . . . . . . . . . . . . . 58.3 Amps
At 240 Volts . . . . . . . . . . . . . . . . . . . . . . . 29.1 Amps
Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-phase
Rated Frequency . . . . . . . . . . . . . . . . . . . . . . . 60 Hertz
Fuel Tank Capacity . . . . . . . . . . . . . . . . . . . 7 U.S. gallons
Shipping Weight . . . . . . . . . . . . . . . . . . . . . . . . . . 198 lbs.
GENERAL MAINTENANCE
RECOMMENDATIONS
The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely
basis; that all discrepancies are corrected; and that the unit
is kept clean and properly stored. NEVER operate a
damaged or defective generator.
NOTE: Should you have questions about replacing
components on your Briggs & Stratton Power Products
generator, please call 1-800-743-4115 for assistance.
Engine Maintenance
See engine operator’s manual for instructions.
KEEP OUT OF REACH OF CHILDREN. DON'T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.
Generator Maintenance
Generator maintenance consists of keeping the unit clean
and dry. Operate and store the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.
NOTE: DO NOT use a garden hose to clean generator.
Water can enter engine fuel system and cause problems. In
addition, if water enters generator through cooling air slots,
some of the water will be retained in voids and cracks of
the rotor and stator winding insulation.Water and dirt
buildup on the generator internal windings will eventually
decrease the insulation resistance of these windings.
Generator Cleaning
•Useadampclothtowipeexteriorsurfacesclean.
•Useasoftbristlebrushtoloosencakedondirtoroil.
•Useavacuumcleanertopickuploosedirt.
•Uselowpressureair(nottoexceed25psi)toblow
away dirt. Inspect cooling air slots and opening on
generator.These openings must be kept clean and
unobstructed.
•Usedmotoroilhasbeenshowntocauseskincancerin
certain laboratory animals.
•Thoroughlywashexposedareaswithsoapandwater.
Avoid prolonged or repeated skin contact with used
motor oil.
CAUTION
WHEN ADJUSTING OR MAKING REPAIRS TOYOUR
GENERATOR
•Disconnectthesparkplugwirefromthesparkplugandplace
the wire where it cannot contact spark plug.
WHEN TESTING FOR ENGINE SPARK
•Useapprovedsparkplugtester.
•DONOTcheckforsparkwithsparkplugremoved.
Unintentional sparking can result in fire or
electric shock.
WARNING
•DONOTexposegeneratortoexcessivemoisture,dust,dirt,
or corrosive vapors.
•DONOTinsertanyobjectsthroughcoolingslots.
Improper treatment of generator can damage it and
shorten its life.
CAUTION

14
PowerBOSS™ 7000W Portable Generator STORAGE
STORAGE
The generator should be started at least once every seven
days and allowed to run at least 30 minutes. If this cannot
be done and you must store the unit for more than
30 days, use the following guidelines to prepare it for
storage.
Generator Storage
•Cleanthegeneratorasoutlinedin“GeneratorCleaning”.
•Checkthatcoolingairslotsandopeningsongenerator
are open and unobstructed.
Engine Storage
See engine operator’s manual for instructions.
Other Storage Tips
•Topreventgumfromforminginfuelsystemoron
essential carburetor parts, add fuel stabilizer into fuel
tank and fill with fresh fuel. Run the unit for several
minutes to circulate the additive through the carburetor.
The unit and fuel can then be stored for up to
24 months. Fuel stabilizer can be purchased locally.
•DONOTstorefuelfromoneseasontoanotherunless
it has been treated as described above.
•Replacefuelcontainerifitstartstorust.Rustand/ordirt
in fuel can cause problems if it's used with this unit.
•Storeunitinacleananddryarea.
•DONOTplaceastoragecoveroverahotgenerator.
•Letequipmentcoolforasufficienttimebeforeplacingthe
cover on the equipment.
Storage covers can be flammable.
WARNING

15
TROUBLESHOOTING 7000W Portable Generator PowerBOSS™
TROUBLESHOOTING
Problem Cause Correction
No AC output is available, but
generator is running.
1. One of the circuit breakers is
open.
2. Fault in generator.
3. Poor connection or defective cord
set.
4. Connected device is bad.
1. Reset circuit breaker.
2. Contact Authorized service facility.
3. Check and repair.
4. Connect another device that is in
good condition.
Generator runs good at no-load
but "bogs" down" when loads are
connected.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. See "Don't Overload Generator".
3. Contact Authorized service facility.
Generator will not start; or starts
and runs rough.
1. Fuel Valve is in the "Off" position.
2. Failed battery.
1. Turn fuel valve to the "On"
position.
2. Replace battery.
Generator shuts down during
operation.
Out of gasoline. Fill fuel tank.
Generator lacks power. Load is too high. See "Don't Overload Generator".

16
PowerBOSS™ 7000W Portable Generator NOTES
NOTES

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC PORTABLE GENERATOR OWNER WARRANTY POLICY
LIMITED WARRANTY
Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the portable generator that is defective in material or
workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by purchaser. This
warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest Authorized Service Dealer in
our dealer locator map at BRIGGSandSTRATTON.COM.
THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW. ANY AND ALL IMPLIED WARRANTIES ARE
EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some
states or countries do not allow limitations on how long an implied warranty lasts, and some states or countries do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation and exclusion may not apply to you. This warranty gives you specific legal rights and
you may also have other rights which vary from state to state or country to country.
2 years*
1 year
Consumer Use
Commercial Use
The warranty period begins on the date of purchase by the first retail end user, and continues for the period of time stated above. “Consumer Use" means per-
sonal residential household use by a retail consumer. “Commercial Use" means all other uses, including use for commercial, income producing or rental pur-
poses. Once equipment has experienced commercial use, it shall thereafter be considered as commercial use for purposes of this warranty.
NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR PROOF OF PURCHASE
RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY SERVICE IS REQUESTED, THE MANUFACTURING
DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY PERIOD.
ABOUT YOUR WARRANTY
We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most warranty
repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not apply if equip-
ment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation. Similarly, the warranty is
void if the manufacturing date or the serial number on the portable generator has been removed or the equipment has been altered or modified. During the
warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to be defective under normal use
and service. This warranty will not cover the following repairs and equipment:
•Normal Wear: Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not cover
repair when normal use has exhausted the life of a part or the equipment.
•Installation and Maintenance: This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized installation or
alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as, in our judgment,
to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as air filters, adjustments, fuel system
cleaning and obstruction (due to chemical, dirt, carbon, lime, and so forth).
•Other Exclusions: This warranty excludes wear items such as o-rings, filters, etc., or malfunctions resulting from accidents, abuse, modifications,
alterations, or improper servicing or freezing or chemical deterioration. Accessory parts such as starting batteries, generator adapter cord sets and
storage covers are excluded from the product warranty. This warranty excludes used, reconditioned, and demonstration equipment, equipment used
for prime power in place of utility power, equipment used in life support applications, and failures due to acts of God and other force majeure events
beyond the manufacturers control. 198189E, Rev. B, 12/31/2006
BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC
JEFFERSON, WI, USA
Effective February 1, 2006 replaces all undated Warranties and all Warranties dated before February 1, 2006
*Second year parts only
WARRANTY PERIOD

PowerBOSS™ 7000 Watt Generador Portátil REGLAS DE SEGURIDAD
18
TABLA DE CONTENIDOS
Reglas De Seguridad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18-20
Conozca Su Generador . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Montaje . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22-23
Operación . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-28
Mantenimiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Almacenamiento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Diagnosticos De Averías. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Garantia . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
DESCRIPCIÓN DEL EQUIPO
Lea este manual de manera cuidadosa y
familiarícese con su generador. Conozca sus usos,
sus limitaciones y cualquier peligro relacionado con
el mismo.
Este generador funciona en base a un motor, de campo eléctrico
giratorio y de corriente alterna (AC). Fue diseñado con la finalidad
de proveer energía eléctrica para luces eléctricas, aparatos,
herramientas compatibles y cargas de motor. El campo giratorio
del generador funciona a una velocidad de 3,6000 rpm usando un
motor con un dous cilindro.
¡PRECAUCIÓN! NO sobrepase la capacidad de vataje y amperaje
del generador. Revise "No Sobrecargue Generador".
Se ha hecho cada esfuerzo posible para asegurarse que la
información que aparece en este manual es exacta y se encuentra
actualizada. Sin embargo, nosotros se reserva el derecho a
cambiar, alterar o de otra manera mejorar, el producto y este
documento en cualquier momento, sin previo aviso.
El Sistema de Control de Emisiones para este generador está
garantizado para juegos estándares por la Agencia de Protección
Ambiental y el Consejo de recursos de aire de California. Para
mayor información acerca de la garantía, consulte con el manual
del operario del motor.
REGLAS DE SEGURIDAD
Éste es el símbolo de alerta de seguridad. Sirve
para advertir al usuario de un posible riesgo para
su integridad física. Siga todos los mensajes de
seguridad que figuren después de este símbolo
para evitar lesiones o incluso la muerte.
El símbolo de alerta de seguridad ( ) es usado con una palabra
(PELIGRO,ADVERTENCIA, PRECAUCIÓN), un mensaje por
escrito o una ilustración, para alertarlo acerca de cualquier
situación de peligro que pueda existir. PELIGRO indica un riesgo
el cual, si no se evita, causará la muerte o una herida grave.
ADVERTENCIA indica un riesgo el cual, si no se evita, puede
causar la muerte o una herida grave. PRECAUCIÓN indica un
riesgo, el cual, si no se evita, puede causar heridas menores o
moderadas. PRECAUCIÓN,cuandoseusasin el símbolo de
alerta, indica una situación que podría resultar en el daño del
equipo. Siga los mensajes de seguridad para evitar o reducir los
riesgos de heridas e inclusive la muerte.
Símbolos de Peligro y Significados
El escape del motor de este producto contiene
elementos químicos reconocidos en el Estado de
California por producir cáncer, defectos de nacimiento u
otros daños de tipo reproductivo.
ADVERTENCIA
CONSERVE ESTAS INSTRUCCIONES
Fuego
Explosión
Gases Tóxicos Superficie Caliente
Descarga Eléctrica
Retroceso
Manual del Operario

REGLAS DE SEGURIDAD 7000 Watt Generador Portátil PowerBOSS™
19
•Cuandouseungeneradorcomopoderdeenergíaauxiliar,notifiquea
la compañía de utilidades. Use el equipo de transferencia aprobado
para aislar el generador de otra utilidad eléctrica.
•Useuninterruptorparalafalladelcircuitodetierra(GFCI)en
cualquier área bastante húmeda o que sea altamente conductiva, tales
como terrazas de metal o trabajo hecho con acero.
•NOtoquelosalambrespeladosoreceptáculos.
•NOuseungeneradorconcableseléctricosqueesténmalgastados,
rotos, pelados o dañados de cualquier forma.
•NOopereelgeneradorbajolalluvia.
•NOmanejeelgeneradorocableseléctricosmientrasestéparadoen
agua, descalzo o cuando las manos y los pies estén mojados.
•NOpermitaquepersonasdescalificadasoniñosoperenosirvanal
generador.
Los generadores producen un voltaje muy poderoso.
Si no aísla el generador de utilidades de energía,
puede hacer que los trabajadores de electricidad
sufran heridas graves e inclusive la muerte, debido a
la retroalimentación de la energía eléctrica.
ADVERTENCIA
•Estegeneradornocumplelanorma33CFR-183delcuerpode
guardacostas de EE.UU. y no debe utilizarse en aplicaciones marinas.
•Elusodeungeneradornohomologadoporcuerpodeguardacostas
de EE.UU. puede provocar lesiones y daños materiales.
ADVERTENCIA
CUANDO AÑADA COMBUSTIBLE O VACÍE EL
DEPÓSITO
•Apagueelgenerador(posiciónOFF)ydéjeloenfriaralmenospor
2minutosantesderemoverlatapadelacombustible.Aflojelatapa
lentamente para dejar que la presión salga del tanque.
•Lleneovacíeeldepósitodecombustiblealaintemperie.
•NOllenedemasiadoeltanque.Permitaalmenosespacioparala
expansión del combustible.
•Laesperaparaalgúncombustiblerociadoparaevaporarantesde
arrancar el motor.
•Mantengalacombustiblealejadadechispas,llamasabiertas,pilotos,
calor y otras fuentes de ignición.
•NOenciendauncigarrilloofume.
CUANDO PONGA EN FUNCIONAMIENTO EL
EQUIPO
•Compruebequelabujía,elsilenciador,eltapóndeldepósitode
combustible y el filtro de aire están instalados.
•NOarranqueelmotorsinlabujíainstalada.
CUANDO OPERE EL EQUIPO
•NOinclineelmotoroelequipo,detalmaneraquelacombustiblese
pueda derramar.
•Estegeneradornoesaptoparaelusoenequiposmóvilesnien
aplicaciones marinas.
CUANDO TRANSPORTE O REPARE EL EQUIPO
•Transporteorepareelequipoconeltanquedecombustiblevacío,o
con la válvula para apagar el combustible, apagada (posición OFF).
•Desconecteelcabledelabujía.
CUANDO ALMACENE O GUARDE EL EQUIPO CON
COMBUSTIBLE EN ELTANQUE
•Almacenealejadodecalderas,estufas,calentadoresdeagua,secadoras
de ropa u otros aparatos electrodomésticos que posean pilotos u
otras fuentes de ignición, porque ellos pueden encender los vapores
de la combustible.
La combustible y sus vapores son extremadamente
inflamables y explosivos.
El fuego o una explosión pueden causar quemaduras
severas e inclusive la muerte.
ADVERTENCIA
•OpereelgeneradorSOLAMENTEalairelibre.
•Instaleunaalarmademonóxidodecarbonoconbateríacercadelos
dormitorios.
•Asegúresedequelosgasesdeescapenopuedanentrarporventanas,
puertas, tomas de aire de ventilación u otras aberturas en un espacio
cerrado en el que puedan acumularse.
•NOopereelgeneradordentrodeunedificioolugarcerrado(aunque
haya puertas o ventanas abiertas), incluyendo el compartimiento del
generador en un vehículo recreativo o RV.
Al generador funcionar, se produce monóxido de
carbono, un gas inodoro y venenoso.
El respirar el monóxido de carbono, producirá
náusea, desmayo o la muerte.
ADVERTENCIA

PowerBOSS™ 7000 Watt Generador Portátil REGLAS DE SEGURIDAD
20
•NOcambieningunavelocidaddeterminada.Elgeneradorsuministra
una frecuencia y un voltaje calificado cuando funciona a una velocidad
determinada.
•NOmodifiquealgeneradorenningunaforma.
Las velocidades de operación en exceso, aumentan los
riesgos de heridas y daños al generador.
Las velocidades bajan en exceso, imponen una carga muy pesada.
PRECAUCIÓN
•Vea"Nosobrecarguegenerador".
•Enciendasugeneradorydejequeelmotorseestabiliceantesde
conectar las cargas eléctricas.
•Conectelascargaseléctricasenlaposicióndeapagado(OFF),luego
encienda (ON) para su operación.
•Apague(OFF)lascargaseléctricasydesconéctelasdelgenerador
antes de parar el generador.
El sobrepasar la capacidad del amperaje y vataje del
generador, puede dañar al generador y los aparatos eléctricos
conectados al mismo.
PRECAUCIÓN
•Useelgeneradorsolamenteconlafinalidadparaelcualfuediseñado.
•Siustedtienealgunapreguntaacercadelasfinalidadesdeusodel
generador, pregúntele a su concesionario o llamada a 1-800-743-4115.
•Opereelgeneradorsolamenteensuperficiesniveladas.
•NOexpongaalgeneradoraunahumedadexcesiva,polvo,suciedado
vapores corrosivos.
•NOinsertecualquierobjetoatravésdelasranurasdeenfriamiento.
•Silosaparatosconectadossesobrecalientan,apáguelosy
desconéctelos del generador.
•Apagueelgeneradorsi:
-Se pierde la salida eléctrica;
-El equipo produce chispas, humo o emite llamas;
-La unidad vibra de una manera excesiva.
El tratamiento inadecuado del generador puede dañarlo y
acortar su vida productiva.
PRECAUCIÓN
CUANDO AJUSTE O HAGA REPARACIONES A SU
GENERADOR
•Siempredesconecteelalambredelabujíaycolóquelodondeno
pueda entrar en contacto con la bujía.
CUANDO PRUEBE LA BUJÍA DEL MOTOR
•Utiliceuncomprobadordebujíashomologado.
•NOcompruebalachispasinlabujíainstalada.
Chispear involuntario puede tener como resultado el
fuego o el golpe eléctrico.
ADVERTENCIA
•NOtoquelassuperficiescalientesyevitelosgasesdelescapeaalta
temperatura.
•Permitaqueelequiposeenfríeantesdetocarlo.
•Dejeunespaciomínimode152cm(5pies)alrededordelgenerador,
incluida la parte superior.
•ElCódigodeNormativaFederal(CFR,Título36:Parques,Bosquesy
Propiedad Pública) obliga a instalar una pantalla apagachispas en los
equipos con motor de combustión interno y a mantenerla en buenas
condiciones de funcionamiento, conforme a la norma 5100-1C (o
posterior) del Servicio Forestal de la USDA. En el Estado de
California, la ley exige el uso de una pantalla apagachispas (Sección
4442 del Código de Recursos Públicos de California). En otros
estados puede haber leyes similares en vigor.
Los motores al funcionar producen calor. La
temperatura del silenciador y de las áreas cercanas
puede alcanzar o pasar los 150ºF (65ºC).
Quemaduras severas pueden ocurrir al hacer
contacto.
Los gases y el calor de escape pueden inflamar los
materiales combustibles y las estructuras o dañar el
depósito de combustible y provocar un incendio.
ADVERTENCIA
•Cuandoarranqueelmotor,tirelentamentedelcablehastasentiruna
resistencia y, a continuación, tire rápidamente de él para evitar su
retroceso.
•NUNCAarranqueopareelmotorcuandohayaaparatoseléctricos
conectados y en funcionamiento.
El rápido repliegue del cable del arrancador
(retroceso) impedirá que el usuario suelte el cable a
tiempo y tirará de su mano y brazo hacia el motor.
Como resultado, podrían producirse fracturas,
contusiones o esguinces.
ADVERTENCIA
Table of contents
Languages:
Other PowerBoss Portable Generator manuals

PowerBoss
PowerBoss 30222 User manual

PowerBoss
PowerBoss 30542 User manual

PowerBoss
PowerBoss 30227 User manual

PowerBoss
PowerBoss 5500 Storm-Plus User manual

PowerBoss
PowerBoss PowerBoss User manual

PowerBoss
PowerBoss 30230 User manual

PowerBoss
PowerBoss 30227 Setup guide

PowerBoss
PowerBoss 30217 User manual

PowerBoss
PowerBoss 030646-0 User manual

PowerBoss
PowerBoss 30222 Setup guide