3.1Note: When delivered and stored, the battery in OFFICE UPS will more or
less lose charge. Full recharge will be achieved after about 4 hours of normal
operation. Do not expect full battery run time during this initial recharge period.
3.2Plug OFFICE UPS into an activating outlet. Do not plug it into a service
branch that has a heavy motor load equipped with it (e.g., an air conditioner or
refrigerator.) Operate in accordance with the indications below prior to switching
OFFICE UPS on.
3.3Plug your computer and monitor into the Battery Power output outlets.
Positions of the rest outlets provide for and datacritical device that requires
power under condition of utility power failure (e.g., an external tape backup,
storage drive or CD ROM.)
Caution: Never connect a laser printer with the Battery Power output
outlets.
3.4Plug your system peripheral equipment (e.g., a scanner, fax printer, audio
device or generator ) into the Surge Protection outlets. There is no power
supplied with these outlets in the event of utility power failure.
3.5The RJ45/RJ11 modular sockets are at the back of OFFICE UPS (300/500VA
Models only), offering protection against surges brought to your computer’s
fax/modem or network interface card by the telephone or network wiring. To
protect a fax/modem, connect the existing cable from the wall outlet to the “IN”
jack. Connect the telephone cable that was supplied with OFFICE UPS from the
“OUT”jack, to the fax/modem. To protect a 10Base TUPT network interface,
contact your LAN manager for a short length of UTP cable with which the
connection between the “OUT”jack and your computer can be made.
3.6Connect Computer interface: UPSMON series software (or other software
supporting RS232 communication) and an interface kits can be used with this
UPS. Use only kits supplied or approved by the manufacturer. If used, connect
the interface cable to the 9pin computer interface port to OFFICE UPS.
Note: Computer interface connection is optional. The UPS works properly
without a computer interface connection.
Caution: Use only factory supplied or authorized UPS monitoring cable.
3.7Switch On/Off control of all system equipment to the on position.
3.8Turn on OFFICE UPS, and all the outlets will be powered. UPS will also
perform a self-test function for 8 seconds, which resolves if the battery power is
sufficient for connected loads. Always keep OFFICE UPS in “On”condition to
keep optimal battery charge.
Note: Classify the instruction above as reference while battery has
thoroughly worn out to be replaced.(3-6 years)
3.Installation