Troubleshooting
?
Problem Possible Cause Solutions
LEDs stop working
LEDs flash on and off
The power line is improperly connected.
The power plug is loose.
The LED driver malfunctions.
The LED chip is damaged.
The output of the driver is abnormal.
The LED chip breaks down.
Reconnect the power cable.
Firmly plug the power in.
Replace with new driver.
Replace with new LEDs.
Replace with new driver.
Replace with new LED chip. Instruction Manual
LED Flood Light
5 years warranty for original purchaser of LED product that is identified on seller's invoice
reflecting its original purchase (the "Product").
1. In order to make a warranty claim, you must notify seller in writing within sixty(60) days after your
discovery of the defect, provide proof of purchase such as the invoice and comply with seller's other
warranty requirements. Upon receiving that notice, to ascertain why fixtures stop working, evidences
would be needed for seller's QC Team to analyze. Seller may require you to promptly return the Product
to Seller when necessary, freight prepaid.
2. The determination of whether the Product is defective shall be made by Seller in its sole discretion with
consideration given to the over all performance of the Product.
3. If seller determines the Product is defective, Seller will elect, in its sole discretion, repair the Product
or replace the Product. Seller reserves the right to utilize new, reconditioned, refurbished, repaired or
remanufactured products or parts in the warranty repair or replacement process. Such products and
parts will be comparable in function and performance to an original product or part, as determined by
Seller in its sole discretion, and warranted for the remainder of the original warranty period. However,
cost of labor and equipment to remove the defective product and install a repaired or a replacement
Product at the end-user facility are excluded. Supplier's aggregate liability with respect to a defective
product shall in any event be limited to the money paid to buyer for that defective product.
The following circumstances will not be warranted:
1. Damage caused by force majeure such as war, riots, sabotage, cyclones, earthquakes, tidal waves,
flooding, lighting strikes, explosions, fire, flood, etc.
2. Damage caused by user's improper delivery, defects caused by wrong operation, wrong treatment
and destruction of machinery.
3. Dismantling or modification or improper maintenance or repairing of the products without the
supplier's authorization.
4. Damage caused by buyer or installer using bad quality cable or other mismatching electronic parts.
5. This warranty is invalid if the product is not used for the purpose for which is originally designed. Any
disputes occurred shall be applied to the laws and regulations of P.R.C.
The seller has the sole right to interpret and amend the above articles.

302×240×63mm
(11.89"x9.45"x2.48")
2.3±0.3kg
(5.07±0.66Lbs)
With aluminum heat sink, high-brightness SMD chip, high-effciency constant current and voltage power
driver, LED Flood light is designed for applications in large industrial areas like airports, big docks,
squares, stadiums, etc. Suirability for use indoors.
Technical Parameters
We appreciate your purchase!
Please read the instruction manual before installation and keep it for future reference.
Reminder
Application
Warning
1. To avoid damage, falling, electric shock or fire, please do not modify the lamp or replace accessories without
confirming with the supplier first.
2. Please authorize only qualified personnel to install the lamp and ensure they follow the instruction manual.
Any improper installation might cause falling, electric shock, fire, or other injury, damage or hazard.
3. Please disconnect power before installation or any maintenance of the lamp.
4. Please disconnect power if it begins to smoke or emit odors, since fire or electric shock may occur. Ask a
qualified person to inspect and maintain the luminaire.
5. Please do not dismantle the lamp without the supplier’s authorization.
6. Please do not touch the power supply when the lamp is operating.
7. If the external flexible cable or cord of the luminaire is damaged, it should only be replaced by the supplier,
a service agent or qualified person.
8. Terminal block not included. The electrical fitting must be installed by a licensed electrician.
9. The light source contained in this luminaire shall only be replaced by the manufacturer or his service agent
or a similar qualified person.
10. Only to be installed outside arms reach.
11. For use in environments where an accumulation of non-conductive dust on the luminaire may be expected.
12.Mounting heights of lights not higher than 20m.
Caution risk of electric shock
-30°C to +50°C(-22°F to +122°F)
-40°C to +70°C(-40°F to +158°F)
50W 100W 150W 200W
Product Specifications
Power Frequency
Outlook Dimensions
Luminaire Net Weight
Working Temperature
Storing Temperature
50 / 60Hz
Input Voltage AC100-240V / AC100-277V / AC200-240V / AC220-240V / AC277-480V
300W
Physical Dimensions(Unit: mm/inch)
4.
90°
90°
150W
300W
390×332×77mm
(15.35"x13.07"x3.03")
433×328×77mm
(17.05x12.91"x3.03")
471×395×87mm
(18.54"x15.55"x3.43)
538×465×96mm
(21.18"x18.31"x3.78")
3.9±0.3kg
(8.6±0.66Lbs)
4.7±0.3kg
(10.36±0.66Lbs)
6.0±0.3kg
(13.23±0.66Lbs)
8.2±0.3kg
(18.08±0.66Lbs)
L
N
GND
brown
blue
yellow/green
black
white
green
Dimmable
DIM-white
blue
blue
brown
DIM+
gray
purple
black
white
Dali Dimmable
Da2 white
blue
Da1
gray
purple
120(4.72")
20(0.79")
11(0.43")
30(1.18") ∅11(0.43")
222mm(8.74") 311(12.24")
25(0.98") 135(5.31") 11(0.43")
∅11(0.43")
40(1.57")
307(12.09")
30(1.18") 160(6.3") 11(0.43")
∅11(0.43")
42(1.65")
374(14.72")
55(2.17")
40(1.57") 240(9.45")
∅11(0.43")
11
(0.43")
444(17.48")
465(18.31")
96
(3.78")
538(21.18")
430(16.93")
55(2.17")
40(1.57") 240(9.45")
∅12(0.47")
12(0.47")
200W100W50W
Popular Floodlight manuals by other brands

Philips
Philips eXpanium eXp 401 Brochure & specs

Somogyi Elektronic
Somogyi Elektronic Home PLL 800 instruction manual

Longman
Longman 25W*6PCS user manual

RAB Lighting
RAB Lighting ANGSHARK quick start guide

Commercial LED
Commercial LED CLF4-100P Series Installation instructions manual

Chauvet
Chauvet Strike 882 Quick reference guide