Thank you for purchasing a compact Powerwerx Switching
Power Supply, designed to supply 25 Amps connuous and
30 Amps peak output at 14.1 VDC. Two models are available:
SS-30DV with front mounted Powerpole connectors and SPS-
30DM which includes front mounted volt & amp digital meters
with adjustable voltage output.
SS-30DV Features
• Front Connecon: 2 Powerpole connectors
• Rear Connecon: 1/4 inch binding posts that also accept
banana plugs or compression connecons
• Illuminated Power Switch
SPS-30DM Features
• Dual Metered Digital (Amps/Volts) Power Supply
• User Selectable variable output voltage from 5~16 VDC by
adjusng the front mounted knob or xed output at 14.1
VDC
• Rear Connecon: 1/4 inch binding posts that also accept
banana plugs or compression connecons
Specicaons
Electrical specicaons:
• Input Range: 100-130 VAC or 200-240 VAC, 50/60Hz (User
switchable)
• Output Voltage: SS-30DV – 14.1 VDC xed, SPS-30DM –
variable 5~16 VDC
• Output Amperage: 25 Amps connuous (30 Amp peak)
• Polarity Ground: Negave
• Internal Protecon: Thermal, over current
• Internal Input Fuse: 6.3 Amps at 115 VAC
• Ripple Peak-to-Peak Max. <100mVpp
• Noise Peak-to-Peak Max. <100mVpp
• Operang temperature rang: 0 ~ 50 °C
• Storage temperature: -20 ~ 85 °C
Physical dimensions and materials:
• Weight: SS-30DM - 3.0 lbs., SPS-30DM – 4.0 lbs.
• Overall Dimensions: 6.1 x 5 x 2.5 in (154mm long, 127mm
wide, 63mm tall)
• Fan: Quiet internal cooling fan
• Machined metal case front bezel
Input Voltage Selecon
The power supply is set up for 230V AC input as shipped from
the factory. For 115V AC applicaons, set the recessed 115/230
input select switch located on the rear of the power supply
into the proper posion. Posions are idened on the switch.
Use a small screwdriver to slide the switch into posion. No
adjustment is necessary for either 50 or 60 Hz input.
SS-30DV & SPS-30DM ▪ Rev 4/2015
SS-30DV & SPS-30DM User Manual
23695 Via Del Rio, Yorba Linda, CA 92887 ▪ 714-674-0073 Phone ▪ 714-674-4949 Fax
Installaon Instrucons
1. Unplug the power supply from the mains supply outlet.
2. Select the correct input voltage (See Input Voltage
Selecon).
3. Connect the power cable’s posive (red) wire to the
posive terminal and connect the negave (black) wire to
the negave terminal on the back of the power supply.
4. Plug the AC power cable into the power socket on the back
of the radio.
5. Plug the power supply into the main AC wall outlet.
Turning the Power Supply ON / OFF
Turn the power supply ON by pressing the power switch to the
‘ON’ Posion.
Before you turn the power supply OFF, turn the radio o as
described in the user documentaon for the radio. Then turn
the power supply o by pressing the power switch to the ’OFF’
Posion.
Cooling
The SS-30DV power supply is cooled by convecon and
forced air cooling (normal airow around the power supply
in combinaon with a temperature controlled fan to improve
cooling at higher levels of use). The fan is temperature acvated
and the speed is controlled by a sensor. When the temperature
rises, the fan speed increases.
Cercaons
• Meets FCC CFR Title 47 Part 15 Subpart B: Class B, CISPR:
2005 ANSI C63.4: 2003
• Meets CE/LVD (Low-Voltage Direcve 2006/95/EC)
standard
• Meets EMC: EN 55022:206+A1: 2007, 2010, EN 61000-3-
2:2006
Package Contents
• Power Supply
• AC Power Cord, 4 .
SS-30DV SPS-30DM
Cauon: Install Indoors
Install the power supply indoors. It is not
designed for operaon out-of-doors or in wet
environments.
Warning: Safe Operaon
To reduce the risk of re or electric shock,
please adhere to these warnings:
• Moisture: Do not expose this appliance to
water or moisture.
• Cleaning: Unplug the power supply from
the mains power outlet before cleaning.
Switching o the power supply will not
reduce this risk.
• Venlaon: Place the power supply in an
area that will allow air to ow freely around
the unit. This will prevent the power supply
and mobile radio from overheang. Do
not block or obstruct any of the venlaon
openings on the unit.
Warning: Servicing
This power supply should be serviced by a
qualied service technician. Incorrect assembly
may result in electric shock or re. This power
supply contains no user serviceable parts inside.
Some of the components inside the power supply
can operate at voltage levels that may be lethal.
SS-30DV & SPS-30DM ▪ Rev 4/2015
SS-30DV & SPS-30DM User Manual
23695 Via Del Rio, Yorba Linda, CA 92887 ▪ 714-674-0073 Phone ▪ 714-674-4949 Fax
Warning: Electrical Connecons
To reduce the risk of re or electric shock, please
adhere to these warnings:
The power supply should be properly connected
and grounded. Use the provided AC power cable
to connect the power supply to a mains power
outlet that is properly installed and grounded, in
accordance with all local codes and ordinances.
If the power supply cord is damaged, it must
be replaced with the same type to comply with
safety requirements.
Warranty
The Powerwerx support policy is simple: we want you to be
happy! If you have a problem, please feel free to contact us
and we will do our best to get you up and running as soon as
possible.
Powerwerx power supplies have a three-year limited warranty.
We will repair or replace (at our discreon) your power supply
if you encounter any problems within three years from the
date of purchase. We reserve the right to charge a reasonable
fee for repairing units with user-inicted damage. It is your
responsibility to ship the defecve unit back to Powerwerx.
We will pay for the return shipping back to you. We reserve
the right to upgrade your equipment to an equivalent or beer
model.
Troubleshoong
Condion Soluon Possible Cause
Low DC Power Supply
output
Power supply AC input voltage switch is not in
the correct posion
On rear panel, change the AC selector switch from
230V to 115V.
No DC output current Power Supply not receiving AC input voltage
or is not receiving correct input voltage
• Power Supply liming output due to
overload or ambient over temperature
condion
• Defecve Power Supply
Using a voltmeter, conrm AC input voltage. Check
input connecons. Conrm correct AC power cable
is installed.
• Reduce DC load to 25A or less and/or determine
cause of over temperature condion.
• Return to place of purchase or contact Powerw-
erx for return authorizaon.
Power supply repeatedly
trips input circuit breaker
with no load connected.
Incorrect input voltage is being applied while
should be 100-120 VAC or 200-240 VAC.
Using a voltmeter, conrm AC input voltage. Confrim
input voltage switch is in the correct posion. Con-
rm correct AC power cable is installed.

This manual suits for next models

1

Other Powerwerx Power Supply manuals

Powerwerx PWRbox MINI User manual

Powerwerx

Powerwerx PWRbox MINI User manual

Powerwerx PWRbox2 User manual

Powerwerx

Powerwerx PWRbox2 User manual

Popular Power Supply manuals by other brands

Corsair AX1500i manual

Corsair

Corsair AX1500i manual

Delta DRS-24V30W1NZ Technical data sheet

Delta

Delta DRS-24V30W1NZ Technical data sheet

qtran Q-VAULT-5 STANDARD INSTALLATION

qtran

qtran Q-VAULT-5 STANDARD INSTALLATION

Qlogic SANbox 5000 Series Replacement guide

Qlogic

Qlogic SANbox 5000 Series Replacement guide

TYCON Solar RemotePro RPST12M manual

TYCON Solar

TYCON Solar RemotePro RPST12M manual

Corsair CMPSU-650TX Brochure & specs

Corsair

Corsair CMPSU-650TX Brochure & specs

KEPCO RAX 3.3-10K instruction manual

KEPCO

KEPCO RAX 3.3-10K instruction manual

Corsair CMPSU-1000HX user manual

Corsair

Corsair CMPSU-1000HX user manual

I-Tech IT6800 Series user manual

I-Tech

I-Tech IT6800 Series user manual

I-Tech IT6400 Series Programming guide

I-Tech

I-Tech IT6400 Series Programming guide

Data Video PD-1 user guide

Data Video

Data Video PD-1 user guide

Delta PMT Series Technical data sheet

Delta

Delta PMT Series Technical data sheet

Ultra Power UP1200W user manual

Ultra Power

Ultra Power UP1200W user manual

KEPCO FPD 100W-48V Operator's manual

KEPCO

KEPCO FPD 100W-48V Operator's manual

KEPCO BOP 10-100GL instruction manual

KEPCO

KEPCO BOP 10-100GL instruction manual

KEPCO PAT 40-0.5 instruction manual

KEPCO

KEPCO PAT 40-0.5 instruction manual

RichardSolo DT100 instruction manual

RichardSolo

RichardSolo DT100 instruction manual

Eventide PowerFactor 2 user manual

Eventide

Eventide PowerFactor 2 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.