
Parameter Description (c)
P04) Select degrees Celsius (°C) or Fahrenheit (°F).
P05) T/C Type - Select thermocouple types J or K.
P06) Over-temp. Alarm Limit - Alarm when process temp. is over setpoint value as set
in parameter.
P07) Under-temp. Alarm Limit - Alarm when process temp. is under setpoint value as
set in parameter.
P08) T/C Pinched - Time, in seconds, that the controller will take to detect a pinched or
shorted thermocouple. (There is current, no rise in temperature)
P09) Open TRIAC/Heater - Time, in seconds, that the controller will take to detect an
open TRIAC, open heater, or open wire. (No current and no rise in temperature)
P10) APO Enable - In the event of a T/C break and the controller is at set point, the
controller uses the last average output power (APO) to maintain temperature. (Automatic
Bumpless Transfer). T/C must be repaired as soon as possible.
P11) Boost Time setting - Time (in seconds) desired for boost mode.
P12) Auto Mode Boost Temp. - Boost temperature over setpoint. (Boost temp. + set-
point)
P13) Manual Mode Boost Power - Manual percentage power output during boost mode
for a set time (P15).
P14) Manual Mode Standby Power - Manual percentage power output during standby
mode.
P15) Auto Mode Standby temp. - Standby/idle setpoint value.
P16) Soft-Start Time - Time duration, in minutes, that the controller is in Soft-Start.
(Bake Out)
P17) Soft-Start Lock - Prevents users from changing mode while in soft-start.
P18) Audible Alarm Enable/Disable - controller audible alarm.
P19) Keypad Lock - YES: Disables all keys, except for the *PMTR* key, to prevent
unwanted changes. NO: All keys enabled.
P20) Frequency - AC line frequency (Display only).
P21) Tuning Stabilization - Adjustment for heaters with lagging thermocouple or low
mass (quick heat dissipation heaters). If there is fluctuation of temperature, adjust higher
(recommended maximum of 75).
7