• Remove the top lid Aand bottom lid Iin accordance with image on the
next page, and pull out the push front Ffrom the outer prole E
• Set the dip-switches as desired, as described on the last page
• Adjust the length of the wire from the wall box to the connection terminal
with a good margin.
• Thread the cabling through the cable outlet Con the outer prole E
• Install the cabling according to diagram J
• Slide the push front Fdown the outer prole Eso they are edge to edge
• Mount outer prole Ewith screws at screw holes Band I
• Mount the top lid Aand bottom lid Iso it “clicks”
• Turn on, wait a few seconds until the unit starts.
MOUNTING AND INSTALLATION
• Cable outlet 599 mm alternative 680 mm from the the lower edge, with the
bottom lid mounted
• Recommended height: about 120 mm from the oor.
• Cable: H05V-U (EK)
H05V-K (RK) is okay to use wire end ferrules
Minimum cross section area according to cable standard
HD21 is 0.5 mm2 for EK and RK
• When mounted outdoors: Drill a drain hole in marked depression in the bottom lid.
PREPARATION
TECHNICAL SPECS
Dimensions 799 x 95 x 25 mm
Power supply 18-30 VDC
Connection cable 2 wires for power supply
2 wires for signaling door auto-
matics
Power consumption Standby ≈ 30mA
Activated ≈ Max 47mA
Relay, max rated current Maximum per pole 2A
Material Outer prole and Push front Aluminum
Material Lids Polyamide