INSTALLATION
• Ensure the mains supply is disconnected or isolated.
• Remove the small screw that secures the transparent connector cover and remove
the cover.
• Loosen the 2 screws on the cable restraint.
• Having cut the 62mm dia mounting hole in the desired location and installed the
feed and load device wiring, pull the wiring down through the hole.
• Feed the wiring through the cable restraint and connect to the sensor as follows:
POSITIONING
• The sensor is suitable for mounting into plasterboard, sheet wood or suspended
ceiling tiles.
• Do not install into damp or conductive surfaces such as metal. It should be placed
away from any ammable materials.
• Before drilling any xing holes, check that there are no hidden obstructions behind
the mounting surface such as pipes or cables.
Please read these instructions carefully before use and retain for future reference.
This sensor must be installed by a qualied electrician in accordance with current
building and IET wiring regulations (BS7671).
IMPORTANT SAFETY INFORMATION
• This sensor is suitable for unearthed lighting ttings (Class II).
• Check that the voltage indicated on the rating plate corresponds with that of the
local network before connecting the appliance to the mains power supply.
• The sensor is suitable for connection to a 220-240V, 50Hz supply. It is designed
for permanent connection to xed wiring, which must be a suitable circuit protected
by an RCD with an operating current not exceeding 30mA and an MCB or fuse of
the correct rating.
• Avoid mounting the sensor close to heat sources such as heating vents.
• Avoid mounting the sensor above objects that may move in wind.
• It is suitable for use in an ambient temperature between -20°C and +40°C.
WHAT’S INCLUDED
• IR Sensor.
• User manual.