Safety Instrucons
Overheang:
Theseamplifiersareintendedforuseinmoderateclimatesonly.Theyshouldnotbeusedintropical
regions.Therecommendedvenlaonclearancesandotherprecauonsgivenintherelevantseconof
thisinstruconleafletshouldbeobservedtopreventoverheang.Nounitshouldbefixedwhereitislikely
tobecomesmotheredbysofurnishingfabricssuchascurtains,orbythermalinsulaonmaterialinaroof
spaceorbuildingvoid.Mainspoweredequipmentshouldnotbeleresngonacarpet
Water and fire risks:
Theapplianceisnotwaterproof.Itisintendedforindooruseonlyandmustnotbefixedwhereitcouldbe
exposedtodrippingorsplashingwater.Objectscontainingliquidsshouldnotbeplacedonornearthe
appliance.Topreventriskoffire,noobjectwithanakedflameshouldbeplacedonorneartheappliance,
oritsassociatedwiring.
Mains plug and disconnecon from the supply:
Theapplianceissuppliedwithastandardfusedplugfied.Ifthisisunsuitable,refertotheinstrucons
below.Ifyouneedtochangethefuseinthefiedplug,a3AmpfusetoBS1362carryingtheASTAorBSI
approvalmarkmustbeused.Alwaysreplacetheplascfusecarrierwhenrenewingthefuse.Theplug(or
othermeansofdisconneconfromthesupply,ifused)shouldremainreadilyaccessibleforoperaon
whennecessary.TheLEDpowerindicatoronthisequipmentshouldnotberegardedasprovidingreliable
indicaonofsupplydisconnecon.
Changing the plug:
Ifthefiedmainsplugisnotsuitableforthesocket‐outletsinuse,itshouldbecutoffandanewplug
fied...
Wiring the new plug: Instruconssuppliedwiththenewplugshouldbefollowed.Thebrownwiremustbe
connectedtothelive(L)terminaloftheplugandthebluewiretotheneutral(N)terminal.Neitherwire
shouldbeconnectedtotheearth(E)terminalofa3‐pinplug(theappliancedoesnotrequireanearth
connecon).Ensurethatthecordgripintheplugiscorrectlyusedandclampsthesheathofthecord
firmly.
Fuse Rang: Ifthenewplugisafusedtype,thefusefiedshouldberatedatnotmorethan3Amp.
Cauon: Theoldplugshouldbedestroyedimmediatelysinceitwouldbedangerousifpluggedintoalive
socket.
2 Year Guarantee
ThisguaranteecoversfailureofyourPROceponproductresulngfrommanufacturingdefectwithina
periodof2yearsfromthedateofsupplytotheend‐user.Thisguaranteedoesnotcoverdamagetothe
productcausedbyabuse,tampering,defecveinstallaonornaturalcausessuchaslightningdischarge.
Repairoraemptedrepair,otherthanbythemanufacturer,willrenderthisguaranteevoid.This
guaranteedoesnotaffectaconsumer'sstatutoryrights.
Website: www.procepon.co.uk
Email: support@procepon.co.uk
©Blake‐UK2017AllrightsreservedE&OEProductSpecificaonmaybeChangedwithoutPriorNoce
Performancedatagivenaretypicalunlessotherwisestated.Wereservetherighttochange
productdesignsandspecificaonswithoutpriornoce.
PD2011‐9036‐03
PROMOD1
UHF AV Modulator Instrucon Manual
ThePROMOD1MK2isageneralpurposeAVmodulatorforusewhereaUHFTVsignalneedstobe
generatedfromtheoutputofequipmentwhichdoesnothaveaninternalmodulator.
Features:
StandardAVinputsonSCARTsocket(phonoadaptersupplied).
UK(SystemI)double‐sidebandmodulatedoutput.
UHFoutputchannelselectableinrangeE21toE69(sengautomacallyrestoredonpower‐up).
VHF‐UHFloop‐throughinput.
Built‐inmainspowersupply.
Channels61‐68canbeusedforlocallymodulatedsignals.
Applicaons:
CCTVsecuritycamera,DVDplayers,camcorders,games,etc.
Locaon:
Themodulatorcanbelocatedinanyconvenientposionanddoesnotrequirefixing.Clearanceofat
least50mmshouldbeallowedaboveandaroundtheunitforvenlaon.Avoidposioningthe
modulatorontopofastackofotherequipmentasthismayresultinoverheang.
Donotleavethemodulatorresngonacarpetorinstallitwhereitmaybecomesmotheredwith
curtainsorothersofurnishingfabrics.Wheninstallingthemodulatorinaroofspaceensurethatit
willnotcomeintocontactwiththermalinsulaonmaterial.
RF signal connecons:
TopreserveRFscreeningintegritythesignalconneconstothemodulatorshouldbemadeusing
goodqualitycoaxialcableandconnectors.Thisisparcularlyimportantinasystemcarryingdigital
terrestrialTV(DTT)tominimisetheingressofimpulsiveelectricalinterference.Theuseofcable
benchmarkedundertheCAIschemeisrecommended.
CrimpFconnectors,usedinaccordancewiththemanufacturersinstrucons,willgivethebest
results.Theimportanceofachievingsoundbraidconneconscannotbeover‐stressed.Connectors
shouldbeghtenedwithaspanner,notlefinger‐ght.

Mains power supply:
Themodulatorissuppliedwithafiedmainsplugandmaybepluggeddirectlyintoa13A(BS1363)
socketoutlet.Ifsocketoutletsofadifferenttypeareinuse,pleaserefertothesafetyinstruconson
page4.Themainsplugshouldremainreadilyaccessibletopermitdisconneconoftheunitfromthe
supply.
Alternavelytheplugmaybecutoffandthemodulatorwiredintoareadilyaccessiblefused
conneconunit,fiedwithanapproved3AfusetoBS1362.Thismethodofconneconis
recommendedforpermanentdistribuonsystemapplicaons,sinceitreducestheriskoftampering
andaccidentaldisconnecon.Pleasenote:Areadilyaccessibleisolangswitchshouldbeprovidedto
allowtheunittobedisconnectedfromthesupplywhennecessary.
Ifthemodulatorisnotconnectedtothemainsusingthefusedplugsupplied,orafusedconnecon
unit,itmustbeprotectedbymeansofafuseorMCBatthefinaldistribuonboardofrangnot
exceeding6A.Pleasenote:Areadilyaccessibleisolangswitchshouldbeprovidedtoallowtheunitto
bedisconnectedfromthesupplywhennecessary.
AnyfixedwiringinstalledtosupplypowertothismodulatorshouldcomplywithBS7671(IEEwiring
regulaons)and,whererelevant,PartPofthebuildingregulaons.TheproMOD1Mk2modulatorisof
ClassIIconstruconanddoesnotrequireaprotecveearthconnecon.Thisdoesnotobviatethe
needtoprovideacircuitprotecve(earth)conductorinthesupplywiring,asrequiredbyBS7671.
System equipotenal bonding:
Distribuonsystemssupplyingsignalstomorethanonehouseholdshouldcomplywiththesafety
requirementsofEN60728‐11.Thiseffecvelyrequiresearthedequipotenalbondingofthesystem.
(Theuseofisolatedoutletplatesisnolongerrecommendedsincetheycompromisescreening
integrityandallowingressofinterference.)BondingmaybeeffectedusingaproBAR5equipotenal
bondingbar.
Seng the output channel number:
Thechannelsengbuonsonthefrontoftheunitarenormallylockedtoprotectagainstaccidental
changeortampering.Tochangetheoutputchannelsengproceedasfollows:
1.Pressandholdbothbuonstogetherforabouttwoseconds.Thechannelno.displaywillstartto
flash.
2.Whilethedisplayisflashing,adjustthechannelno.asrequiredusingthesortbuon.
3.Whenthedisplaystopsflashing(abouttwosecondsaerthelastbuonpress)thenewchannel
sengisstoredinthenon‐volalememory.
4.RepeatfromStep1ifnecessary,totryadifferentchannel,oriftheme‐outoccurredtoosoon.
Iftheoutputchannelischangedaerinstallaon,allTVreceiverswhichareusingthemodulators
outputwillneedtohavetheirappropriatechannelsengsretuned.
Notesonchannelselecon:
Choiceofanappropriatemodulatorchannelsengisimportanttoavoidinterferenceproblems.
Themodulatoroutputshouldnotbesetonthesamechannelasanyoff‐airanalogueordigital
signalcarriedonthesystem.Usingachannelwhichcoincideswithanoff‐airDTTsignalisa
commoncauseofanoisylookingmodulatorpicture.
Alsoavoidadjacentchannels(N±1relaonship).
Avoidanycombinaonwhichresultsinsignalsspaced5channelsapart(N±5relaonship).
TheoldavoidN±9rulecanusuallybeignored,duetotheimprovedimagerejeconofmodern
TVs.
Anyothermodulatorsinthesamesystem(inVCRs,etc.)aresubjecttothesamerules,whichalso
applybetweenmodulators.
Tocheckforinterferencetootherchannelscausedbythemodulator,disconnecttheRFINand
RFOUTcablesandlinkthemtogetherusingaback‐to‐backadapter.
Tocheckforinterferencecausedbyanoff‐airorotherupstreamsystem‐generatedsignalto
themodulatorsoutputchannel,unplugordisabletherelevantinputfeedtoRFIN.
InformaononUKTVtransmierchannelnumberscanbefoundatthefollowingWebURLs:
hp://www.bbc.co.uk/recepon/transmiers/tv_trans/index.shtml
hp://www.ofcom.org.uk/stac/recepon_advice/index.asp.html
1.TolerancesgivenintheITU‐RRecommendaonarenotapplicable.
2.TheL&Rinputsareaddedtoprovideamonosignalformodulaon.(Quotedsensivityapplieswith
bothchannelsdriven.)
TVSystem SystemI(ITU‐RRec.BT.470)(Note1)
ModulaonSpectrumType Double‐sideband
OutputUHFchannel E21‐E69(setfromfrontpanel,storedinnon‐volalememory)
OutputSignalLevel 75dBµV(typical,peaksync)
RFloop‐throughbandwidth 47‐862MHz
RFloop‐throughgain 1.5dB
Videoinputlevel 1Vp‐p(internal75Ωterminaon)
Audioinputlevel 200mVRMSsinefor±20KHzpeakdeviaon(1KHzmodulang
frequency)(note2)
Powerrequirement 230VAC50Hzat4W(5.5VA),suppliedwithfiedmainsplugtoBS1363
This manual suits for next models
1
Other PROception Modulator manuals
Popular Modulator manuals by other brands

Ekselans
Ekselans MD HD EASY TWIN user manual

Teknoline
Teknoline TQM 1616 user manual

DRAKE
DRAKE VM2050 instruction manual

Fracarro
Fracarro MOD90S operating instructions

TradeWind International
TradeWind International PMM Instruction and operation manual

Linear Technology
Linear Technology LTC5599 Demo Manual