Safety Instrucons
Overheang:
Theseamplifiersareintendedforuseinmoderateclimatesonly.Theyshouldnotbeusedintropical
regions.Therecommendedvenlaonclearancesandotherprecauonsgivenintherelevantseconof
thisinstruconleafletshouldbeobservedtopreventoverheang.Nounitshouldbefixedwhereitislikely
tobecomesmotheredbysofurnishingfabricssuchascurtains,orbythermalinsulaonmaterialinaroof
spaceorbuildingvoid.Mainspoweredequipmentshouldnotbeleresngonacarpet
Water and fire risks:
Theapplianceisnotwaterproof.Itisintendedforindooruseonlyandmustnotbefixedwhereitcouldbe
exposedtodrippingorsplashingwater.Objectscontainingliquidsshouldnotbeplacedonornearthe
appliance.Topreventriskoffire,noobjectwithanakedflameshouldbeplacedonorneartheappliance,
oritsassociatedwiring.
Mains plug and disconnecon from the supply:
Theapplianceissuppliedwithastandardfusedplugfied.Ifthisisunsuitable,refertotheinstrucons
below.Ifyouneedtochangethefuseinthefiedplug,a3AmpfusetoBS1362carryingtheASTAorBSI
approvalmarkmustbeused.Alwaysreplacetheplascfusecarrierwhenrenewingthefuse.Theplug(or
othermeansofdisconneconfromthesupply,ifused)shouldremainreadilyaccessibleforoperaon
whennecessary.TheLEDpowerindicatoronthisequipmentshouldnotberegardedasprovidingreliable
indicaonofsupplydisconnecon.
Changing the plug:
Ifthefiedmainsplugisnotsuitableforthesocket‐outletsinuse,itshouldbecutoffandanewplug
fied...
Wiring the new plug: Instruconssuppliedwiththenewplugshouldbefollowed.Thebrownwiremustbe
connectedtothelive(L)terminaloftheplugandthebluewiretotheneutral(N)terminal.Neitherwire
shouldbeconnectedtotheearth(E)terminalofa3‐pinplug(theappliancedoesnotrequireanearth
connecon).Ensurethatthecordgripintheplugiscorrectlyusedandclampsthesheathofthecord
firmly.
Fuse Rang: Ifthenewplugisafusedtype,thefusefiedshouldberatedatnotmorethan3Amp.
Cauon: Theoldplugshouldbedestroyedimmediatelysinceitwouldbedangerousifpluggedintoalive
socket.
2 Year Guarantee
ThisguaranteecoversfailureofyourPROceponproductresulngfrommanufacturingdefectwithina
periodof2yearsfromthedateofsupplytotheend‐user.Thisguaranteedoesnotcoverdamagetothe
productcausedbyabuse,tampering,defecveinstallaonornaturalcausessuchaslightningdischarge.
Repairoraemptedrepair,otherthanbythemanufacturer,willrenderthisguaranteevoid.This
guaranteedoesnotaffectaconsumer'sstatutoryrights.
Website: www.procepon.co.uk
Email: support@procepon.co.uk
©Blake‐UK2017AllrightsreservedE&OEProductSpecificaonmaybeChangedwithoutPriorNoce
Performancedatagivenaretypicalunlessotherwisestated.Wereservetherighttochange
productdesignsandspecificaonswithoutpriornoce.
PD2011‐9036‐03

PROMOD1
UHF AV Modulator Instrucon Manual
ThePROMOD1MK2isageneralpurposeAVmodulatorforusewhereaUHFTVsignalneedstobe
generatedfromtheoutputofequipmentwhichdoesnothaveaninternalmodulator.
Features:
 StandardAVinputsonSCARTsocket(phonoadaptersupplied).
 UK(SystemI)double‐sidebandmodulatedoutput.
 UHFoutputchannelselectableinrangeE21toE69(sengautomacallyrestoredonpower‐up).
 VHF‐UHFloop‐throughinput.
 Built‐inmainspowersupply.
 Channels61‐68canbeusedforlocallymodulatedsignals.
Applicaons:
 CCTVsecuritycamera,DVDplayers,camcorders,games,etc.
Locaon:
Themodulatorcanbelocatedinanyconvenientposionanddoesnotrequirefixing.Clearanceofat
least50mmshouldbeallowedaboveandaroundtheunitforvenlaon.Avoidposioningthe
modulatorontopofastackofotherequipmentasthismayresultinoverheang.
Donotleavethemodulatorresngonacarpetorinstallitwhereitmaybecomesmotheredwith
curtainsorothersofurnishingfabrics.Wheninstallingthemodulatorinaroofspaceensurethatit
willnotcomeintocontactwiththermalinsulaonmaterial.
RF signal connecons:
TopreserveRFscreeningintegritythesignalconneconstothemodulatorshouldbemadeusing
goodqualitycoaxialcableandconnectors.Thisisparcularlyimportantinasystemcarryingdigital
terrestrialTV(DTT)tominimisetheingressofimpulsiveelectricalinterference.Theuseofcable
benchmarkedundertheCAIschemeisrecommended.
CrimpFconnectors,usedinaccordancewiththemanufacturersinstrucons,willgivethebest
results.Theimportanceofachievingsoundbraidconneconscannotbeover‐stressed.Connectors
shouldbeghtenedwithaspanner,notlefinger‐ght.

Mains power supply:
Themodulatorissuppliedwithafiedmainsplugandmaybepluggeddirectlyintoa13A(BS1363)
socketoutlet.Ifsocketoutletsofadifferenttypeareinuse,pleaserefertothesafetyinstruconson
page4.Themainsplugshouldremainreadilyaccessibletopermitdisconneconoftheunitfromthe
supply.
Alternavelytheplugmaybecutoffandthemodulatorwiredintoareadilyaccessiblefused
conneconunit,fiedwithanapproved3AfusetoBS1362.Thismethodofconneconis
recommendedforpermanentdistribuonsystemapplicaons,sinceitreducestheriskoftampering
andaccidentaldisconnecon.Pleasenote:Areadilyaccessibleisolangswitchshouldbeprovidedto
allowtheunittobedisconnectedfromthesupplywhennecessary.
Ifthemodulatorisnotconnectedtothemainsusingthefusedplugsupplied,orafusedconnecon
unit,itmustbeprotectedbymeansofafuseorMCBatthefinaldistribuonboardofrangnot
exceeding6A.Pleasenote:Areadilyaccessibleisolangswitchshouldbeprovidedtoallowtheunitto
bedisconnectedfromthesupplywhennecessary.
AnyfixedwiringinstalledtosupplypowertothismodulatorshouldcomplywithBS7671(IEEwiring
regulaons)and,whererelevant,PartPofthebuildingregulaons.TheproMOD1Mk2modulatorisof
ClassIIconstruconanddoesnotrequireaprotecveearthconnecon.Thisdoesnotobviatethe
needtoprovideacircuitprotecve(earth)conductorinthesupplywiring,asrequiredbyBS7671.
System equipotenal bonding:
Distribuonsystemssupplyingsignalstomorethanonehouseholdshouldcomplywiththesafety
requirementsofEN60728‐11.Thiseffecvelyrequiresearthedequipotenalbondingofthesystem.
(Theuseofisolatedoutletplatesisnolongerrecommendedsincetheycompromisescreening
integrityandallowingressofinterference.)BondingmaybeeffectedusingaproBAR5equipotenal
bondingbar.
Seng the output channel number:
Thechannelsengbuonsonthefrontoftheunitarenormallylockedtoprotectagainstaccidental
changeortampering.Tochangetheoutputchannelsengproceedasfollows:
1.Pressandholdbothbuonstogetherforabouttwoseconds.Thechannelno.displaywillstartto
flash.
2.Whilethedisplayisflashing,adjustthechannelno.asrequiredusingthesortbuon.
3.Whenthedisplaystopsflashing(abouttwosecondsaerthelastbuonpress)thenewchannel
sengisstoredinthenon‐volalememory.
4.RepeatfromStep1ifnecessary,totryadifferentchannel,oriftheme‐outoccurredtoosoon.
Iftheoutputchannelischangedaerinstallaon,allTVreceiverswhichareusingthemodulators
outputwillneedtohavetheirappropriatechannelsengsretuned.
Notesonchannelselecon:
Choiceofanappropriatemodulatorchannelsengisimportanttoavoidinterferenceproblems.
 Themodulatoroutputshouldnotbesetonthesamechannelasanyoff‐airanalogueordigital
signalcarriedonthesystem.Usingachannelwhichcoincideswithanoff‐airDTTsignalisa
commoncauseofanoisylookingmodulatorpicture.
 Alsoavoidadjacentchannels(N±1relaonship).
 Avoidanycombinaonwhichresultsinsignalsspaced5channelsapart(N±5relaonship).
 TheoldavoidN±9rulecanusuallybeignored,duetotheimprovedimagerejeconofmodern
TVs.
 Anyothermodulatorsinthesamesystem(inVCRs,etc.)aresubjecttothesamerules,whichalso
applybetweenmodulators.
 Tocheckforinterferencetootherchannelscausedbythemodulator,disconnecttheRFINand
RFOUTcablesandlinkthemtogetherusingaback‐to‐backadapter.
 Tocheckforinterferencecausedbyanoff‐airorotherupstreamsystem‐generatedsignalto
themodulatorsoutputchannel,unplugordisabletherelevantinputfeedtoRFIN.
InformaononUKTVtransmierchannelnumberscanbefoundatthefollowingWebURLs:
hp://www.bbc.co.uk/recepon/transmiers/tv_trans/index.shtml
hp://www.ofcom.org.uk/stac/recepon_advice/index.asp.html
1.TolerancesgivenintheITU‐RRecommendaonarenotapplicable.
2.TheL&Rinputsareaddedtoprovideamonosignalformodulaon.(Quotedsensivityapplieswith
bothchannelsdriven.)
TVSystem SystemI(ITU‐RRec.BT.470)(Note1)
ModulaonSpectrumType Double‐sideband
OutputUHFchannel E21‐E69(setfromfrontpanel,storedinnon‐volalememory)
OutputSignalLevel 75dBµV(typical,peaksync)
RFloop‐throughbandwidth 47‐862MHz
RFloop‐throughgain 1.5dB
Videoinputlevel 1Vp‐p(internal75Ωterminaon)
Audioinputlevel 200mVRMSsinefor±20KHzpeakdeviaon(1KHzmodulang
frequency)(note2)
Powerrequirement 230VAC50Hzat4W(5.5VA),suppliedwithfiedmainsplugtoBS1363

This manual suits for next models

1

Other PROception Modulator manuals

PROception proMOD1 Mk2 User manual

PROception

PROception proMOD1 Mk2 User manual

PROception proMOD1 Mk 2 User manual

PROception

PROception proMOD1 Mk 2 User manual

PROception proLINK22 User manual

PROception

PROception proLINK22 User manual

PROception proMOD1 User manual

PROception

PROception proMOD1 User manual

Popular Modulator manuals by other brands

Velleman K8004 Assembly manual

Velleman

Velleman K8004 Assembly manual

IKUSI MAW-201 installation guide

IKUSI

IKUSI MAW-201 installation guide

PVI VeCOAX ULTRA-HDMI-QAM-IP user manual

PVI

PVI VeCOAX ULTRA-HDMI-QAM-IP user manual

ClearView HD168Bi user manual

ClearView

ClearView HD168Bi user manual

Lemco HDMOD-Q1 Operation manual

Lemco

Lemco HDMOD-Q1 Operation manual

Polytron HDM 2 T/IP user manual

Polytron

Polytron HDM 2 T/IP user manual

Kenwood KC-Z1 user manual

Kenwood

Kenwood KC-Z1 user manual

Polytron HDS 2 C/IP user manual

Polytron

Polytron HDS 2 C/IP user manual

Jensen KVFM1 How to install and operate

Jensen

Jensen KVFM1 How to install and operate

GSS HDM 2380 P CI Assembly instructions

GSS

GSS HDM 2380 P CI Assembly instructions

GSS HDM 500 C Assembly instructions

GSS

GSS HDM 500 C Assembly instructions

Lumistar LS-18-P user manual

Lumistar

Lumistar LS-18-P user manual

Ekselans MD HD EASY TWIN user manual

Ekselans

Ekselans MD HD EASY TWIN user manual

Teknoline TQM 1616 user manual

Teknoline

Teknoline TQM 1616 user manual

DRAKE VM2050 instruction manual

DRAKE

DRAKE VM2050 instruction manual

Fracarro MOD90S operating instructions

Fracarro

Fracarro MOD90S operating instructions

TradeWind International PMM Instruction and operation manual

TradeWind International

TradeWind International PMM Instruction and operation manual

Linear Technology LTC5599 Demo Manual

Linear Technology

Linear Technology LTC5599 Demo Manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.