ENERGY CONSUMPTION METER UK - 1
PCF-605
Thank you for purchasing this Profile product. Please
note: It is important that you read this manual before
using the product. And be sure to save this manual for
possible use later.
Please note
The Energy Meter must be charged before use.
After 15 minutes, the LCD screen will be
operational, but to fully charge the battery, the
device must be plugged into the mains for at least
12 hours.
The Energy Meter is the easiest way for you to
measure the energy costs of connected appliances.
Technical data
Operating voltage: 230V AC (50/60 Hz) alternating
current (AC)
Maximum power of connected appliances: 3680 W
Maximum current: 16A
Input/ Output: via earthed socket
Operating temperature: + 10 to +40° C
Energy display: 0 kWh to 999.9 kWh
Maximum registration time: 9999 hours
Only use indoors (IP20)
Correct use
The measurement range of the Energy Meter is 5W to
3680W. Exact measurement of values below or above
this range is not possible. Use outside this range can
overload and damage the unit.
The Energy Meter was designed to monitor and
measure electric appliances.
The Energy Meter is approved only for use with
230V AC.
Only 230V AC, 50/60Hz electric appliances may be
connected.
The maximum power of the connected loads may
not exceed 3680W (maximum amperage 16A).
Use of the Energy Meter is only allowed indoors in
dry environments. Use in the open air is strictly
prohibited!
Always heed the instructions on the identification
label located on the connected power cables.
Use other than that described above can result in
damage to the product and the risk of short circuit,
fire, electric shocks, etc.
The product as a whole may not be converted or
modified. The safety instructions must be followed
strictly.
Safety instructions
The manufacturers accept no liability for damage to
objects or persons that arises from incorrect use or
noncompliance with the safety prescriptions. All
damage claims resulting in such cases are void.
The Energy Meter may only be connected to
regulated outlets (230V AC, 50/60Hz- 10/16A) with
a ground.
The connected appliances may not use more than
3680W (16A).
The operating temperature of the connected
appliance must be between 10º and 40º.
High temperatures, especially when measuring high
levels of electrical power, can result in overheating
and damage to the Energy Meter.
Avoid use in extreme weather conditions and in the
vicinity of inflammable gases, moisture and dust.
For safety reasons, the unit may never be operated
in a wet or damp environment.
During cleaning or maintenance, disconnect each
source of power from the Energy Meter. The battery
and the LCD screen can retain a charge, even when
the unit is disconnected from all sources of power.
Insert no metal parts or other objects in the Energy
Meter.
If it is established that safe use is no longer
possible, take the Energy Meter out of operation and
ensure that it is not mistakenly put back into
operation by someone else. If there is visible
damage to the Energy Meter, it must be taken out of
service immediately.
Features
Display of current time (24-hour clock), day, energy
consumption in Watts and billing rate.
Display of total time connected, energy consumed
and the cost of energy consumed.
Display of total registered times, total time and
percentages.
Programmable day and night rates.
Configuration, connection and operation
The procedure for setting the time and the billing
rate is the following:
Setting the current time and day
1. Simultaneously press the “+” and ”-
“ buttons to enter the system
configuration. The first setting is the
current time.
2. Use the “+” button to increase the
value of the flashing position from 0 to
9; use the “-“ button to decrease the value of the
flashing position.
3. Press the “MODE” button to move the next position.
4. After setting the day, push the “MODE” button again
– billing rate 1 for the system can now be configured.
Setting billing rate 1 (day rate)
1. Set the start time for billing rate
1. For example day rate starts at
7.00 a.m.
2. Set rate 1. All values are
introduced in quantities of eurocents.
E.g. 1.00€ = 100cent
3. Use the “+” button to increase the value of the
flashing position from 0 to 9; use the “-“ button to
decrease the value of the flashing position.
4. Press the “MODE” button to move to the next
position.
5. Press the “MODE” button - billing rate 2 for the
system can now be configured.
ENERGY CONSUMPTION METER UK - 2
PCF-605
Setting billing rate 2 (night rate)
1. Set the start time for billing rate
2. For example, the night rate
starts at 9.00 p.m.
2. Set rate 2. For example 0.30€
equals 030 cents.
3. Use the “+” button to increase the value of the
flashing position from 0 to 9; use the “-“ button to
decrease the value of the flashing position.
4. Press the “MODE” button to move to the next
position.
5. Pressing the button for longer than 5 seconds will
accept your settings and return you to the display
screen. If you only have 1 rate, set billing rate 1 to
00h00 and the cost per KWh. Set the time for billing
rate 2 also to 00h00 and enter the cost per KWh, equal
as rate 1.
Reset
Press “mode, +, -“ at the same time. All data that were measured
will be reset after 5 seconds.
Introduction to display screens
There are 3 display screens that contain three different
types of data. Use the “MODE” button to select the
type of screen you wish to view.
Display 1 Current time (24-hour clock),
day, current consumption of the
connected appliance and current cost
per hour.
Display 2 Total registered time,
total energy consumed per Kwh
and cost per Kwh of actual
energy consumed (only
indicates both values if at least 1
KWh has been used). Costs are
expressed in Euro’s, for example 3.2 is three euros
and 20 cents.
Display 3 Total registered time, total
time worked and percentage of time
worked.
Maintenance
Check the Energy Meter regularly for damage.
Use only a dry, soft cloth to clean the unit and the
LCD screen.
Use no cleaning products.
Never immerse the unit in water.
Maintenance and repairs may only be performed by
technicians familiar with the applicable regulations.
Declaration of conformity
ELTRA NV, Pachtgoedstraat 2, 9140 Temse, Belgium
hereby declares that the product PCF-605 satisfies all
essential requirements and other relevant stipulations
of LVD directive 2006/95/EC, and has been tested
according to the following standards:
EN 61010-1:2001
The original declaration of conformity can be obtained
at www.profileDIY.com
Guarantee
The guarantee period for PCF-605 is 2 years, and
begins on the date of purchase.
During the guarantee period, Eltra NV will repair all
defects due to shortcomings in material or
manufacturing. Eltra NV may choose to repair or
replace the defective device.
Eltra NV is not required to repair or replace units that
were subject to damage, improper use, or
modifications or changes that were made after the
date of purchase.
Bring the defective unit, together with the original proof
of purchase, to the shop where it was purchased.
Always include a note describing the problem.
Damage claims
Eltra NV can may not be held liable for damage of
whatever kind if the unit was not correctly installed
according to the prescribed installation instructions, or
for damage resulting from unforeseen circumstances
such as natural disasters, lightning strikes,.... Thus, all
costs resulting from these situations are exclusively for
the expense of the buyer, and are not covered by the
guarantee conditions.
Eltra nv, Pachtgoedstraat 2, 9140 Temse, BELGIUM
Eltra DIYeuronet / Elar bv, Ambachtsstraat 8, 5405 AM Uden,
THE NETHERLANDS
www.eltra.eu
www.profileDIY.com

Other manuals for PCF-605

1

Other Profile Measuring Instrument manuals

Profile PCF-605 User manual

Profile

Profile PCF-605 User manual

Profile Comfort PCF-600 User manual

Profile

Profile Comfort PCF-600 User manual

Popular Measuring Instrument manuals by other brands

Knick 830 R manual

Knick

Knick 830 R manual

Bruker BioSpin minispec mq60 user manual

Bruker BioSpin

Bruker BioSpin minispec mq60 user manual

Pepperl+Fuchs Pulscon LTC57 manual

Pepperl+Fuchs

Pepperl+Fuchs Pulscon LTC57 manual

Bosch LR Professional 1 Original instructions

Bosch

Bosch LR Professional 1 Original instructions

Agilent Technologies 4284A Service manual

Agilent Technologies

Agilent Technologies 4284A Service manual

Vaisala GMP252 user guide

Vaisala

Vaisala GMP252 user guide

GEIT GAS 3200 BIOGAS Series Operation manual

GEIT

GEIT GAS 3200 BIOGAS Series Operation manual

Endress+Hauser Liquiline CM44P Brief operating instructions

Endress+Hauser

Endress+Hauser Liquiline CM44P Brief operating instructions

KROHNE IFC100 quick start

KROHNE

KROHNE IFC100 quick start

Metria M10 instruction manual

Metria

Metria M10 instruction manual

BRONKHORST FLOW-BUS instruction manual

BRONKHORST

BRONKHORST FLOW-BUS instruction manual

Chauvin Arnoux AEMC MN352 user manual

Chauvin Arnoux

Chauvin Arnoux AEMC MN352 user manual

Mirion Technologies RDS-32 user manual

Mirion Technologies

Mirion Technologies RDS-32 user manual

BANGGOOD GS-320 user manual

BANGGOOD

BANGGOOD GS-320 user manual

Gems Sensors 856 Instruction bulletin

Gems Sensors

Gems Sensors 856 Instruction bulletin

Hanna Instruments HI97105 instruction manual

Hanna Instruments

Hanna Instruments HI97105 instruction manual

PCB Piezotronics 66632APZ2 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 66632APZ2 Installation and operating manual

Baumer isiLine 36 operating instructions

Baumer

Baumer isiLine 36 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.