Progressive Dynamics PD1200 Series Operating instructions

Consult a licensed electrician or RV technician for installation assistance 814356 Rev B
Installation and Operation Guide for
Inverter Remote Display
© 2018 Progressive Dynamics Enterprises, LLC. All rights reserved.
I. LIMITED WARRANTY: Progressive Dynamics Warrants its power inverters to be free from defects in material or workmanship under normal use and ser-
vice; and limits the remedies to repair or replacement.
II. DURATION: This warranty shall extend for a period of two years from the original date of purchase, and is valid only within the continental limits of the
United States and Canada.
III. WARRANTY EXCLUSIONS: This warranty does not apply to:
A. Any product which has been repaired or altered in any way by an unauthorized person or service station
B. Damage caused by excessive input voltage, misuse, negligence, or accident; or an external force
C. Any product which has been connected, installed, or adjusted or used other than in accordance with the instructions furnished, or has had the serial number
altered, defaced, or removed
D. Cost of all services performed in removing and reinstalling the power inverter
E. ANY LOST PROFITS, LOST SAVINGS, LOSS OF USE OF ENJOYMENT OR OTHER INCIDENTAL DAMAGES ARISING OUT OF THE USE OF,
OR INABILITY TO USE, THE PRODUCT. THIS INCLUDES DAMAGES TO PROPERTY AND, TO THE EXTENT PERMITTED BY LAW, DAM-
AGES FOR PERSONAL INJURY. THIS WARRANTY IN IN LIEU OF ALL OTHER WARRANTIES, INCLUDING WARRANTIES OF MER-
CHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSES.
IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.
V. CLAIM PROCEDURE: Upon discovery of a defect, Progressive Dynamics shall be supplied the following information a the address listed below:
A. Name and address of claimant
B. Name, model, and serial number of the product
C. Name year and model of the recreational vehicle in which the product was installed
D. Date of purchase
E. Complete description of the claimed defect
Upon determination that a warranty claim exists (a defect in material or workmanship occurring under normal use and service) the inverter shall be shipped postage
prepaid to Progressive Dynamics together with proof of purchase. The product will be repaired or replaced and returned postage prepaid.
Mail Returns to: Progressive Dynamics
507 Industrial Road
Marshall, MI 49068
For Warranty Service contact: [email protected]
Member
Record the unit’s model and serial number in case you need provide this information in the future. It is much easier to record this infor-
mation now, instead of trying to gather it after the unit has been installed.
Model: Serial Number:
PD12011 (PD1200 series Remote Display) - 25 ft cable
PD1601-25 (PD1600 series Remote Display) - 25 ft cable
PD1601-50 (PD1600 series Remote Display) - 50 ft cable
See website www.progressivedyn.com
for more trouble shooting information and return instructions

Consult a licensed electrician or RV technician for installation assistance 814356 Rev B
The Remote Display is designed for use with specific Progressive Dynamics Inverters. The remote will allow complete monitoring of your
inverter. This guide will help you install and use the remote control to monitor the functions of your inverter.
Materials List
The inverter base package includes the following items:
(1) PD1200 series inverter remote or PD1600 series inverter remote
(refer to model number of remote display)
(1) Owner’s guide & mounting template
(1) Connection cable (included) - (refer to model number for length of cable)
NOTE:
If any of the items are missing, contact Progressive Dynamics for replacement.
Use only the cable included with that specific remote display. DO NOT use a
cable that is not designated for that specific unit.
Included Items & Connecting the Remote
Figure 1 Inverter Remote (Communication cable not shown. See model number for cable length)
Connecting the remote to the inverter
Plug the connector plug into the port on the top of the inverter and the back of the remote control using the supplied communication
cable (see Figure 2). Failure to use the supplied communication cable may result in damage to the Remote Display.
It is recommended that you install the remote into the desired location prior to connecting the cable to the remote and the inverter.
Please refer to the installation portion of this guide for those instructions.
Figure 2 Connecting communication cable
Verifying connection
Once the remote display is securely connected to the Inverter and the inverter is
turned on, it will begin displaying readouts immediately. If your remote control
display does not begin to display information, confirm that the communication
cable is securely connected into both ports on the inverter and the remote con-
trol.
NOICE: EQUIPMENT DAMAGE
This Remote Display User Guide is in addition to, and incorporated by reference, the relevant product information for each product in the
PD1200 Series Inverter. Before reviewing this guide, you must read the relevant product manual. Unless specified, information on safety,
specifications, installation, and operation is as shown in the primary documentation. Ensure you are familiar with that information before
proceeding.
Notice that PD12011 remote display is only compatible with PD1200 series Inverters. PD1601-25 & PD1601-50 remote displays are only
compatible with PD1600 series inverters. Attempting to use a remote display not designated for that specific inverter could cause damage to
the unit and the remote display.
Failure to follow these instructions will result in your inverter to not function properly.
PD12011
Remote Display
PD1601-25 &
PD1601-50
Remote Display

Consult a licensed electrician or RV technician for installation assistance 814356 Rev B
Figure 3 Inverter Remote Display
Figure 4 Remote Display Panel
Select Button Power Button Display
Using the Controls
Error Code Condition Description
E-1
Low battery volt-
age detected
Input voltage has dropped beneath 10.5V for
several seconds. The inverter will automati-
cally restart when the input voltage reaches
12.0V.
E-2
High battery volt-
age shutdown
Input voltage has surpassed 15.5V. The
inverter will automatically restart when the
input voltage falls below 15.0V.
E-3
AC output over-
load shutdown
Output power has surpassed the continuous
power limit or the peak power limit. The
inverter will not automatically restart. A
manual restart is necessary
E-4
Over-temperature
shutdown
Internal temperature of the inverter has ex-
ceeded its safe operating limit. The inverter
will automatically restart when internal tem-
peratures return to safe operating conditions.
ERROR CODES
E-5
Internal Error An internal error has been detected. The
inverter will not automatically restart. A
manual restart is necessary
Display Features
Power Button: Press to turn on; hold to turn off
Select Button: Cycles between display states:
Input Voltage, Output Voltage, Output
Power, Sleep, Error Code (if applicable)
Power Indicator: Lights up green when the inverter is on
Fault Indicator: Flashes red when an error has occurred
Shore Indicator: Lights up yellow when AC input is detected
Low Bat Warning Indicator: Lights up red when the battery
is nearing the end of its charge
Sleep: Lights automatically dim after 30 seconds
NOTE: For all error codes consult page 16 in the Installation and
Operation Guide for troubleshooting methods
Figure 5 Display Indicators
Power Indicator Shore Power Indicator Low Bat Warning Indicator Fault Indicator

Consult a licensed electrician or RV technician for installation assistance 814356 Rev B
Installation Template
Installing the remote display on the wall
1. Place the template on the wall.
2. Mark the corners (or trace the dotted lines) of the recess outline
on the wall.
3. Mark the two mounting holes for the two screws on the wall.
4. Remove the template from the wall.
5. Cut along the recess outlines on the wall to make a hole for the
remote control.
6. Pre-drill the mounting holes appropriate to the mount screws
(not provided) that will be used.
7. Connect the communication cable to the RJ9 port on the inverter
and the remote control (see Figure 2).
8. Mount the remote panel unit on the wall.
Note:
Ensure that there are no
Obstructions present, such as:
- Pipes
- Insulation
- Electrical Wiring
Ensure that there is at least 1” (25.4 mm) of space for communication cable.
Figure 5 PD12011 Remote Display Mounting Template
Figure 6 Mounting Diagram
MOUNTING
HOLE
MOUNTING
HOLE
[73.03]
2.875
[101.64]
4.00
[57.15]
2.250
[69.89]
2.75