Projoy Electric PEDH Series User manual

www.projoy-electric.com
User
Manual
PEDH Series Molded Case DC Switch
V1.0 20220720

www.projoy-electric.com
Molded Case DC Switch User Manual
1 General
2 Usage Information
3 Product Overview
4 Certificates
5 Product Model
6 Product Features
7 Technical Parameters
8 Dimensions
1
1
1
1
2
2
2
3
PEDH Series Molded Case DC Switch
CONTENTS
9 Wiring Diagram
10 Auxiliary Contact
11 Attachment
7
7
8
PEDH-315/2P 160~315A 3
PEDH-315/3P 160~315A 3
PEDH-315/4P 160~315A 4
PEDH-630/2P 315~500A 5
PEDH-630/3P 315~500A 5
PEDH-630/4P 315~500A 6

1 General
2 Usage Information
Thank you for purchasing this product, please read the user manual carefully before installing, using or maintaining the
product. This manual is only applicable to PEDH series Molded Case DC Switch.
Version Date Remark Chapter
V1.0 2022-07-05 First Edit -
www.projoy-electric.com
PEDH Series Molded Case DC Switch
1
1. The normal use environment temperature of the product: -5℃~+40℃;
Note: If it is used in the range of -40℃~+70℃, please consult with the manufacturer.
2. When the altitude exceeds 2000m, please consult with the manufacturer for use;
3. Pollution level: level 3;
4. Main circuit installation category: Ⅲ;
5. Enclosure protection class: IP20(except for wiring terminals);
6. No explosion dangerous medium environment and no rain and snow attack environment.
3 Product Overview
The PEDH series isolation switch is developed and designed by Projoy Electric Co., Ltd. using the modular concept. The switch
body is assembled with special modules and new appearance design which reduces the exposed metal parts of the switch
body and improves the safe operation performance; the modular design facilitates the disassembly and combination of the
switch, and is suitable for different use requirements and occasions; It adopts two operation modes: handle operation mecha-
nism and electric energy storage, which is convenient for the reliable operation of the switch.
PEDH series Molded Case DC Switch is suitable for low-voltage DC distribution network with rated working voltage of DC1000V,
DC1500V and rated working current of 160A~500A, which can meet the corresponding rated current of on-load making and
breaking, and can also withstand the overload current in the line in a short time.
PEDH series isolation switch can be used for main power switches, isolation maintenance switches and emergency stop
switches in new energy industries, energy storage systems, photovoltaic systems, electric power, building construction and
petrochemical factories.
1) The product is strictly prohibited to be installed in an environment containing flammable and explosive gases and
humid condensation, and it is strictly prohibited to operate the product with wet hands;
2) During the work of the product, it is strictly forbidden to touch the conductive parts of the product;
3) When installing, maintaining and repairing the product, it is necessary to ensure that the line is shutdown;
4) Do not install in places where gaseous media can corrode metals and damage insulation;
5) In order to avoid dangerous accidents, the installation and fixing of the product must be carried out in strict
accordance with the requirements of the manual.
Warning
4 Certificates
GB/T 14048.1「General Rules for Low Voltage Switchgear and Control Equipment」
GB/T1 4048.3 「Combinations of Low-Voltage Switchgear, Control Equipment Switches, Isolators, Isolation switches and Fuse」
IEC 60947-1 「General Rules for Low Voltage Switchgear and Control Equipment」
IEC 60947- 3「Combinations of Low-Voltage Switchgear, Control Equipment Switches, Isolators, Isolation switches and Fuse」
National Standard
International Standard

www.projoy-electric.com
PEDH Series Molded Case DC Switch
2
5 Product Model
6 Product Features
PEDH
- -
1500 DB 315 N
Projoy Electric
High Current
Rated Voltage
1000/1500V
DB Dinrail Board
DC Door Clutch
Rated Current
160/200/
250/315A
Number of Poles
N=2,3,4
-
1) Visualization window: The opening and closing positions of the moving contacts are clearly visible, providing a higher level
of safety assurance;
2) "0" position padlock: at zero position, the handle can be padlocked to prevent misoperation;
3) Rotating double breakpoint contact structure: ensure the isolation safety distance and meet the needs of reliable isolation;
4) Double-spring operating mechanism: Double-spring energy storage mechanism realizes quick connection and discon-
nection the transition effect is independent of the operation speed.
Safe isolation
1) It can be operated with load;
2) Modular structure design: The product is composed of a single-pole module and an operating mechanism module. The
operating mechanism can provide various positions to improve the utilization of installation space;
3) Operation mode: Provide a variety of operation modes, such as operation in the front cabinet, operation outside the front
cabinet, side operation, etc.;
4) Bracket installation: The bracket can be installed horizontally or vertically to better adapt to on-site installation occasions.
Reliable application
Rated voltage VDC
Number of poles
Rated impulse withstand
voltage (kV)
Short-time withstand current
Icw (kA)
Rated short-circuit making
capacity Icm (kA)
Mechanical life (Times)
Electrical life (Times)
Wiring method
Installation method
Protection class
Operating temperature
Storage temperature
Altitude
Pollution level
Use type
2
10
8,000
1,000
Cable crimp terminal or copper bar wiring method
DB (Dinrail Board), DC (Door Clutch)
IP20(handle outside the cabinet IP65)
-40~+70℃(60℃No derating)
-50~+80℃
≤2000m
3
DC-PV1, DC-PV2
12
43
1500
DC-PV1(A)
DC-PV2(A)
PEDH1000-315 PEDH1000-630 PEDH1500-315 PEDH1500-630
1000
Insulation voltage VDC 15001500
2 4 2 4 32 4
Type 160、200、250、315
160、200、250、315
315、400、500
315、400、500
160、200、250、315
160、200、250
315、400、500
315、400、500
5kA/1s 10kA/50ms 5kA/1s 10kA/50ms
Minimum copper cross-
sectional area (mm2)
Operating torque(N.m)
185 240 (2sticks) 185 240 (2sticks)
14-20 16-30 14-20 16-30
7 Technical Parameters

www.projoy-electric.com
PEDH Series Molded Case DC Switch
3
8 Dimensions
PEDH-315/2P 160~315A
a) The mechanism is in the middle
b) The mechanism is on the left
PEDH-315/3P 160~315A
aa) The mechanism is in the middle

www.projoy-electric.com
PEDH Series Molded Case DC Switch
4
PEDH-315/3P 160~315A
b) The mechanism is on the left
PEDH-315/4P 160~315A
a) The mechanism is in the middle
b) The mechanism is on the left

www.projoy-electric.com
PEDH Series Molded Case DC Switch
5
PEDH-630/2P 315~500A
a) The mechanism is in the middle
b) The mechanism is on the left
PEDH-630/3P 315~500A
a) The mechanism is in the middle

www.projoy-electric.com
PEDH Series Molded Case DC Switch
6
PEDH-630/3P 315~500A
b) The mechanism is on the left
PEDH-630/4P 315~500A
a) The mechanism is in the middle
b) The mechanism is on the left

www.projoy-electric.com
PEDH Series Molded Case DC Switch
7
9 Wiring Diagram
Parallel Cooper Bar
a) PEDH-315 160~315 b) PEDH-630 315~500
Wiring method 1 Wiring method 2
2P Wiring method 1 Wiring method 2
3P Wiring method 1 Wiring method 2
4P Wiring method: 2 circuits
10 Auxiliary Contact
Contact type
NO
NC
3
AC 250V
AC-15
3
AC 400V
AC-15
18
18
DC 24V
DC-13
28
28
DC-13
DC 48V
14
14
Working current (A)
Characteristic

www.projoy-electric.com
PEDH Series Molded Case DC Switch
8
Wiring
Auxiliary switches are two sets of one normally open and one normally closed contact. The lead wire is 1.5mm2 copper wire,
and the wire length is 150mm.
F22
F12
F11
F14
F24
F21
11 Attachment
Installation dimension of operating handle outside the cabinet (mm)
φ31
φ79
125
45
Copper bar wiring screw size (mm)
L
L
M8
M12
Current level
PEDH-315
PEDH-630
Socket head cap screw M8*20 or
Copper bar wiring screw
Hexagon bolt M10*40
Hexagon bolt M8*25
Schematic diagram of the operating mechanism outside the cabinet
Rotating shaft Mounting nuts
Cabinet door
Sealing ring
Handle
Mounting screws
Cover
Operating handle outside the cabinet
Outside the cabinet handle
installation dimensions
Cabinet door hole size
Installation dimension of the extension shaft for operation outside the cabinet
Product Model
PEDH-315/630 330
Standard length (mm) Cross section (mm2)
10*10
This manual suits for next models
10
Table of contents