QUICK REFERENCE GUIDE
PROLITE - 41
Find the user's manual on the download area at: www.promaxelectronics.com
FRONT VIEW
1
2
3
4
5
Screen
Windproof Cover
Keyboard
Sleeve heater
External interface (USB - Power)
FUSION SPLICER DEVICE
7
8
9
10
11
12
Electrode Bar
Electrode Cover
Wind Protector
Microscope
V-groove
Clamp slot
13
Fiber Presser Foot
3
2
1
4
5
7
8
9
10
11
12
13
TUBE HEATER
EXTERNAL INTERFACE
KEYBOARD
QUICK REFERENCE GUIDE
PROLITE - 41
14
Clamp
15
Heater Plate
16
Cover Plate
Reset key
25
17 18
USB Port
Power Port
Sleeve heating key
19
Power key
20
Arrow keys
21
Exit key/Switch XY key
Menu/Confirm
22
23
24
Start key
19
20
22
21
23
24
25
14
15 16
14
17 18
QUICK REFERENCE GUIDE
PROLITE - 41
Splice Mode:
Set the parameters of splice mode.
Maintain:
Electrode maintenance, arc correction, calibration, etc.
System:
Set the display parameters, system language & time, restore
to initial settings, etc.
History:
Record of number of arc times, splice results, etc.
Help:
Provide key operation manual.
Set the parameters of some system functions such as heating
mode, arc compensation, reset time, etc.
Function:
09-30
100%
Enter
Back
09:30
Function SpliceMode Maintain
System History Help
FUNCTION SETTINGS MENU
Sleeve heating mode:
Set the sleeve heating time.
Fast ArcTest Mode:
If this is set "on", after splice is completed, the equipment
adjusts arc current and tension test.
Tension Test:
If this is set “on”, after splice is completed, the equipment will
restore and Tension test will perform itself.
Reset Waiting
Time:
If the Tension test is set “off”, the system will restore the
equipment after the waiting time is over.
Auto Starting:
If it is set “on”, it will perform a splice itself when the cover is
closed.
100%
Enter
Back
09:30
Fast ArcTest Mode
Reset waiting time
Tension test
Auto starting
Sleeve heating mode
Function
on
12 s
on
on
Enter
MENU INTRODUCTION
Align Offset
Threshold:
An error message is displayed if the misalignment of the two
fibers spliced exceeds the misalignment limit. The setting
range is 0.0-1.5 µm.
Loss Threshold:
An error message is displayed if the estimated splice loss
exceeds the loss limit. The setting range is 0-0.2db.
Compensation arc
Time:
Splice loss may be improved by compensative arc in some
cases.
Fiber Alignment
Mode:
Cladding align or core align can be set.
Fast Splice Mode:
If it is "on" it accelerates the alignment.
An error message is displayed if the clamp angle of the two
fibers spliced exceeds the angle threshold. The setting range
is 0-4°.
Fiber Angle
Threshold:
Fiber type:
Set according to the type of fibre used such as SM (single
mode), MM (Multimode), DS (Dispersion shifted), NZDS (Non-
zero dispersion shifted). Each fibre type can have up to 30
fusion splice pre-set programs. Other available fibre types are
BIF (Bend Insensitive Fibre), UBIF (Ultra-Bend Insensitive
Fibre), EDF (Erbium Doped Fibre) and G.657B3 (Bend
Insensitive Single-Mode fibres).
Splice Operate
Mode:
Automatic, Semi-automatic or Manual.
Splice Program No.:
30 groups preset splice program and 80 groups of users-set
splice program.
Edit Splice
Program:
Edit splice parameters under the current number of program.
Clean Arc Time:
It cleans dust on the fiber surface by short-time arc. The
duration ranges from 0 to 200 ms.
Surface Angle
Threshold:
An error message is displayed if the head face angle of either
left or right side of fiber exceeds the angle threshold. The
setting range is 0-8°.
SPLICE MODE MENU
100%
Enter
Back
09:30
Edit splice program
SpliceMode
Splice operate mode Auto
Splice program No. SM-1
Clean Arc time 100 ms
Fiber type SM
Surface angle threshold 3.0 °
Fiber angle threshold 0.8 °
Loss threshold 0.10 dB
Align offset threshold 0.4 um
Fiber alignment mode Core align
Compensation arc time 1.0 s
Fast splice mode Off
14.11.2018
14.11.2018
14.11.2018
Auto heating on
Auto Heating:
If it is set “on”, it starts heating when the cover is lid.
QUICK REFERENCE GUIDE
PROLITE - 41
SPLICE RESULTS STORAGE AND QUERY
Total Arc Number:
Electrodes arc times since the last record is eliminated.
Reset Arc Count:
Eliminate arc times after electrodes are replaced.
Total Records:
The splice records having been stored by system.
View Records:
3000 groups of the latest splice records can be viewed. Users
could query the splice parameters and results.
Delete Records:
Delete all splice records.
USER MANUAL
DOWNLOAD
Find the user's manual on the download area at:
www.promaxelectronics.com
PROLITE - 41
23-10-2019 (0 DG0348)
v2.2
MAINTENANCE MENU
Arc correction:
It performs an arc test and correction.
Clean
Electrodes:
It repeats short arc several times to clean the electrodes.
Replace
electrodes:
After replace electrodes, repeats short arc several times to
stabilize the electrodes and to measure the electrodes
position.
SYSTEM AND FUNCTION SETTINGS
Brightness
Adjustment:
Adjust the display brightness.
Language
Selection:
Select language.
Screen Flip:
Screen rotates 180º.
Time Setup:
Set system time and date.
Restore
Factory Settings:
Restore all parameters to factory settings.
Power Saving
Mode:
Set auto sleep or shutdown.
Silent Mode:
Turn on or off the key beep.
System
Language selection English
Time setup
Screen flip Default
Restore factory settings
Brightness adjustment 100%
100%
Enter
Back
09:30
Clean electrodes
Self Test Mode
CorrectLed
Replace electrodes
Arc correction Enter
Maintain
History
Detect system parameters
View records
Clean electrodes
Clean Arc count Enter
Total Arc number 0
Delete records
Query fault
records:
It shows data about fault records.
Delete fault
records:
It deletes fault records.
Selt Test Mode:
It measures the electrodes position, motor and other system
parameters automatically.
Replace electrodesTotal records 0
100%
Enter
Back
09:30
Silent mode on
Power saving mode
Delete fault records
Query fault records
100%
Enter
Back
09:30
14.11.2018
14.11.2018
14-11-2018
Enter
CorrectLed:
When there is sudden change of temperature it may appear fog
on the camera lens. Use this option to clear fog.
PDF

Other manuals for Prolite-41

1

Popular Industrial Electrical manuals by other brands

COMEXIO EnOcean Unit manual

COMEXIO

COMEXIO EnOcean Unit manual

Murata GRM219R61E475MA73 Series Reference sheet

Murata

Murata GRM219R61E475MA73 Series Reference sheet

Murata GRM0225C1E7R1BA03 Series Reference sheet

Murata

Murata GRM0225C1E7R1BA03 Series Reference sheet

Murata GRM0225C1C120GA03 Series Reference sheet

Murata

Murata GRM0225C1C120GA03 Series Reference sheet

Murata GJM1555C1H390JB01 Series Reference sheet

Murata

Murata GJM1555C1H390JB01 Series Reference sheet

CARIF 260 BSA instruction manual

CARIF

CARIF 260 BSA instruction manual

Murata GRM0335C1H1R4CA01 Series Reference sheet

Murata

Murata GRM0335C1H1R4CA01 Series Reference sheet

Murata GCM21BR71H104KA37 Series Reference sheet

Murata

Murata GCM21BR71H104KA37 Series Reference sheet

Murata GRM0225C1E9R2DA03 Series Reference sheet

Murata

Murata GRM0225C1E9R2DA03 Series Reference sheet

Murata GRM2195C1H113JA01 Series Reference sheet

Murata

Murata GRM2195C1H113JA01 Series Reference sheet

Murata GRM1555C1H561JA01 Series Reference sheet

Murata

Murata GRM1555C1H561JA01 Series Reference sheet

Siemens 3VL9550-6CP30 operating instructions

Siemens

Siemens 3VL9550-6CP30 operating instructions

Murata GQM1875C2E1R1WB12 Series Reference sheet

Murata

Murata GQM1875C2E1R1WB12 Series Reference sheet

Murata GRM216R71H471KA01 Series Reference sheet

Murata

Murata GRM216R71H471KA01 Series Reference sheet

INNO VIEW 3 user manual

INNO

INNO VIEW 3 user manual

Murata GRM022R61A471MA01 Series Reference sheet

Murata

Murata GRM022R61A471MA01 Series Reference sheet

PR electronics 9202 Series manual

PR electronics

PR electronics 9202 Series manual

LEGRAND 4 210 01 manual

LEGRAND

LEGRAND 4 210 01 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.