protech SORADIO User manual

SORADIO
SORADIO
Installation instructions - Pages 2-15
529 VISTA BLVD 89434 SPARKS, NV - USA
Toll Free: 1-800-498-9662 / Phone: (775) 856-7333 / Fax: (775) 856-7658 Website: www.protechusa.com E-mail: [email protected]
EN

PROTECH SORADIO

1
PROTECH SORADIO
CONTENTS
1WIRING ............................................................................................................. 2
2SMARTPHONE APPLICATION ........................................................................ 3
2.1 Settings.............................................................................................................................. 4
2.2 Input status ........................................................................................................................ 4
2.3 Input settings ..................................................................................................................... 5
2.4 User settings...................................................................................................................... 5
2.5 Event log............................................................................................................................ 7
2.6 Network settings ................................................................................................................ 8
3RADIO CONFIGURATION ................................................................................ 9
3.1 Configuration using the CONNECT RADIO COORDINATOR ........................................... 9
3.2 Activate the radio on the SORADIO................................................................................. 11
4MAINTENANCE .............................................................................................. 12
5TECHNICAL SPECIFICATIONS ..................................................................... 12
6PRODUCT REFERENCES.............................................................................. 13

2
PROTECH SORADIO
1 WIRING
Note: All common inputs are connected together.
Example of input wiring:
The inputs are seen out of alarm when they are closed. They are seen in alarm when they are open
(Positive security).
* LEDs status L1, L2 et L3:
L1: green
Operating mode
OFF: Radio Mode
ON: RS485 Mode (unused in SORADIO)
LEDs active only if BLE
is activated after a short
press on the tamper
L2: orange
Radio configuration
status
Blinking: Radio mode not configured
ON: Radio mode configured
L3: red
BLE status
OFF: BLE deactivated
Blinking: BLE active waiting for connection
ON: BLE active connected to the application
Maximum length of 12V DC power supply cables:
(cable type SYT1 shielded)
∅Wire
Wire section
Maximum length of cables
0.6 mm
0.02 in
0.3 mm²
23 AWG
500 m
0.31 mi
0.9 mm
0.04 in
0.6 mm²
20 AWG
1124 m
0.7 mi
1.4 mm
0.06 in
1.5 mm²
16 AWG
2506 m
1.56 mi
Note: When using the same cable to supply power to several components, the indicated distances should be divided
by the number of connected components. When using several wires with the same section in parallel by
polarity, the indicated distances should be multiplied by the number of connected wires.
N° Terminals
Description
1
Input 1
2
Common
3
Input 2
4
Common
5
Input 3
6
Common
7
Input 4
8
Common
9
Input 5
10
Common
11
Input 6
12
Common
13
Input 7
14
Common
15
Input 8
16
Common
17
X
18
X
19
X
20
X
21
0V Power supply
22
+12V DC Power supply
E1
C
*
L1
L2
L3

3
PROTECH SORADIO
2 SMARTPHONE APPLICATION
Note: The smartphone application is compatible from Android 4.1 or higher.
1. Download the smartphone application “Sorhea Connect”.
2. Launch application “Sorhea Connect”.
Authorize activation of Bluetooth if requested to do so by the application.
3. Press the tamper switch very briefly (1s) to activate the BLE connection of the SORADIO.
Note: the connection remains active as long as the SORADIO is connected to the
smartphone application. It is deactivated when the cover is closed (tamper closed) or after
1 minute of inactivity (application closed).
4. Launch the search.
Sorhea Connect
Tamper SORADIO

4
PROTECH SORADIO
5. Click on the product found.
2.1 Settings
2.2 Input status
Note: It is possible to customize the name of an input.
Click on the name to change and Save.
Enter the module name:
Click on the name to change and Save
Setting the time on the module
Real-time input status
Legend:
No alarm
Alarm
Inactive
SORADIO found
Radio ID of the SORADIO found
identical to the sticker on the card.

5
PROTECH SORADIO
2.3 Input settings
Each input can be:
•Enable / disable input.
•Eject input.
To apply the changes, click Save.
Enable input
Input disabled
Input enabled
Eject input
Input not ejected
Input ejected
Note: It is only possible to eject an input if it is enable.
Input disable = Relay associated forced in alarm
Input ejected = Relay associated forced out alarm.
2.4 User settings
Managing user settings allows saving settings or applying settings to inputs: name and status of
inputs (activated, ejected).
2.4.1 Saving user configuration
Select Input
disable input
Eject input
Select “Save configuration”
Enter the name of the backup file
Click “SAVE”
Not used

6
PROTECH SORADIO
2.4.2 Applying an existing user setting
By default, the application offers the following setting options:
→SO-BEAM S RX (FR)
→SO-BEAM M/L/XL Mixed (FR)
→SO-BEAM M/L/XL TX (FR)
→SO-BEAM M/L/XL RX (FR)
→SO-BEAM M/L/XL TX (EN)
→SO-BEAM S RX (EN)
→SO-BEAM M/L/XL RX (EN)
→SO-BEAM M/L/XL Mixed (EN)
→MIRIS 3000/3100 CONNECT Sigle Direction (FR)
→MIRIS 3000/3100 CONNECT Double Direction (FR)
→COLIRIS II CONNECT Sigle Direction (FR)
→COLIRIS II CONNECT Double Direction (FR)
→MIRIS 3000/3100 CONNECT Sigle Direction (EN)
→MIRIS 3000/3100 CONNECT Double Direction (EN)
→COLIRIS II CONNECT Double Direction (EN)
→COLIRIS II CONNECT Sigle Direction (EN)
→8 INPUTS REMOTE MODULE default settings
Select the settings to load
Click on “Apply configuration”

7
PROTECH SORADIO
2.5 Event log
1. Click on Menu
2. Click on Event log
3. View event log
List of events:
−Alarm
−End Alarm
−Eject
−End eject
−BLE Connection
−Configuration
−Time setting
−Reset log event
−Power on
Menu
Event log
Input name
Type of events
Date/Time of the event

8
PROTECH SORADIO
2.6 Network settings
1. Click on Menu
2. Click Network settings
Menu
Network Settings
Default parameter unused in SORADIO
The black point "●" indicates that the SORADIO
has no assigned channel.
(configuration via
coordinator not done)
Indication that radio is active

9
PROTECH SORADIO
3 RADIO CONFIGURATION
3.1 Configuration using the CONNECT RADIO COORDINATOR
1. Enable radio, see §3.2.Activate the radio on the SORADIO.
Note: By default, the radio is disabled.
2. Refer to manual CONNECT RADIO COORDINATOR NT400 to start radio search.
3. SORADIO settings and status from UNIVERSAL MAXIBUS
A. Product Name: Possibility to customize the name of the connected product.
Change the name and click SAVE.
B. Reading network address RS485 (unused in SORADIO).
C. Input management:
For each input, it is possible to:
•Customize the name of the input.
•Enable / disable input.
•Input ejection.
To apply changes, click on SAVE.
Enable input
Input enabled
Input disabled
Eject input
Input not ejected
Input ejected
A
B
C
D

10
PROTECH SORADIO
D. Note: It is only possible to eject an input if it is enable.
Input disable = Relay associated forced in alarm
Input ejected = Relay associated forced out alarm.
E. Input State
(Note: status not available in radio mode)
4. SORADIO Event log
List of "Events" available in event log:
−Start alarm
−Power on
−End alarm
−time setting
−Eject
−Change configuration
−End eject
−Reset event log
No alarm Alarm Disable
Date
Input
Events
ID Radio : Network
address
ID Radio

11
PROTECH SORADIO
3.2 Activate the radio on the SORADIO
Note: radio activation allows resetting the radio configuration on the SORADIO and switching to
radio search (wait for pairing with the CONNECT RADIO COORDINATOR)
1. Disconnect the power supply on the SORADIO
2. Press the button and switch on the SORADIO
3. Hold the button until the orange LED L2 lights.
(≈ 5s, The green led L1 lights up during the
procedure).
L1
L2
L3

12
PROTECH SORADIO
4 MAINTENANCE
Failure Probable causes Solutions
Permanent alarm
-Input disabled
-Non-wired entry
-Activate input.
-Check wiring.
Never alarm
-Input ejected
-Remove ejection from input
The smartphone application
does not detect the
SORADIO
-The BLE connection of the 8
INPUTS REMOTE MODULE
is not activated.
-Press the tamper for at least 1
second. (see §3)
5 TECHNICAL SPECIFICATIONS
Power supply
4.5V to 30V DC
Consumption
10mA
Operating temperature
-35°C to +70°C / -31°F to 158°F
Relative humidity
95% max. non-condensing
Protection index
IP65
Weight
0.3Kg / 0.66 lb
Electromagnetic compatibility
Compliance with European standards (label CE)
Range
Mesh network allowing messages to be relayed
from MI8 to MI8:
400m / 0.25 mile point to point and in free field

13
PROTECH SORADIO
6 PRODUCT REFERENCES
•SORADIO ref: 30790001
Option:
•Pole mount bracket set Ø76 ref: 30793001
•Pole mount bracket set Ø101 ref: 30793002
•Bracket set for mounting on 100x50 pole or frame 3100 SF ref: 30793003
•Bracket set for mounting on frame 3100 DF ref: 30793004
Changes or modifications not expressly approved by PROTECH / SORHEA could void the user’s
authority to operate the equipment.
FCC Part 15 compliance statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
This module has been approved under FCC part 15C 15.247. This modular transmitter is only FCC
authorized for this specific rule part. - The module is limited to PROTECH / SORHEA installation
only.
The host product should be check for compliance to any other FCC rules that apply to the host not
covered by the modular transmitter grant of certification. (For example, Part 15 Subpart B).
If testing of the host product with this transmitter installed and operating is necessary (to verify that
the host product meets all the applicable FCC rules), a test mode for this specific module is available
upon request to SORHEA.
Trace antenna design, list of antenna type approved and professional installation is not applicable
to this modular certification.
ISED (Canada) Licence-Exempt Radio Apparatus
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation,
Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject
to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may
cause undesired operation of the device.

14
PROTECH SORADIO
ISDE (Canada) appareils radio exempts de licence
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux
CNR d’Innovation, Sciences et Développement économique Canada applicables aux
appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions
suivantes :
1. L’appareil ne doit pas produire de brouillage ;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d’en compromettre le fonctionnement.
Radio Frequency (RF) Exposure Compliance of Radiocommunication for mobile
Apparatus
To satisfy FCC and IC RF Exposure requirements for mobile devices, a separation distance
of 20 cm or more should be maintained between the antenna of this device and persons
during operation. To ensure compliance, operation at closer than this distance is not
recommended. This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
Conformité à l’exposition aux champs RF des équipements radio mobiles
Pour satisfaire aux exigences FCC et IC concernant l'exposition aux champs RF pour les
appareils mobile, une distance de séparation de 20 cm ou plus doit être maintenu entre
l'antenne de ce dispositif et les personnes pendant le fonctionnement. Pour assurer la
conformité, il est déconseillé d'utiliser cet équipement à une distance inférieure. Cet émetteur
ne doit pas être co-situé ou fonctionner conjointement avec une autre antenne ou un autre
émetteur.
Host Product Labeling:
FCC Certification:
The final end product must be labeled in visible area with the following:
“Contains Transmitter Module FCC ID: QVA-SORADIO”
ISED Certification:
The final end product must be labeled in visible area with the following:
L’équipement final doit être étiqueté sur un endroit visible avec le texte suivant :
“Contains IC: 11664A-SORADIO”
Host Product User’s Manual:
The user manual for end users must include the following information in a prominent location
“IMPORTANT NOTE: To comply with FCC and ISED RF exposure compliance requirements,
the antenna used for this transmitter must not be colocated or operating in conjunction with
any other antenna or transmitter. The equipment should be installed and operated with a
minimum distance of 20cm between the radiator and the body.”
“ Notice importante : Pour satisfaire aux exigences FCC et ISED concernant l'exposition aux
champs RF pour les appareils mobile, cet émetteur ne doit pas être co-situé ou fonctionner
conjointement avec une autre antenne ou un autre émetteur. Une distance de séparation de
20 cm ou plus doit être maintenu entre l'antenne de ce dispositif et les personnes pendant
le fonctionnement. “
Table of contents
Other protech Control Unit manuals
Popular Control Unit manuals by other brands

Emerson
Emerson KEYSTONE FIGURE PCS17 Instruction, Operation and Maintenance Manual

A.R.I.
A.R.I. MODEL D-040L 1" Installation operation & maintenance

UfE
UfE ENS26 Product description

Zurn Wilkins
Zurn Wilkins ZW209Q Installation, Troubleshooting, Maintenance Instructions

National Instruments
National Instruments 2591 installation guide

janitza
janitza 800-CON installation manual