EMERGENCY OPENING:
KEY OVERRIDE:
1. INSERT THE POWER OVERRIDE JACK INTO THE COVER REMOVAL HOLE
AND PUSH UPWARDS.
2. GENTLY REMOVE THE KEYHOLE COVER AND INSERT THE TUBULAR KEY.
3. TURN THE KEY CLOCKWISE (RIGHT)AND THEN TURN THE KNOB TO OPEN
THE SAFE.
POWER OVERRIDE:
1. INSTALL 4NEW BATTERIES IN THE POWER OVERRIDE BOX AND PLUG THE
POWER OVERRIDE JACK INTO THE POWER OVERRIDE HOLE.
2. OPEN THE SAFE BY FOLLOWING STEP 1.
3. OPEN BATTERY COVER AND INSTALL 4NEW BATTERIES.
4. CLOSE BATTERY COVER,THE SAFE GOES BACK TO NORMAL OPERATION
MODE.
NOTE: THE SAFE KEEPS THE CODE IN MEMORY UP TO 6MONTHS WITHOUT
POWER.
TIPS:
•U
SE DIGITS 1–0TO ENTER YOUR CODE.
•U
SE THE *KEY AS BACKSPACE TO CLEAR THE LAST DIGIT.
•H
OLD THE *KEY FOR MORE THAN 2SECONDS TO CLEAR THE LCD
DISPLAY.
•IF YOU ENTER A WRONG CODE THE LCD DISPLAY WILL SHOW
ERROR.
•I
F YOU ENTER A WRONG CODE FOR THREE CONSECUTIVE TIMES THE
LCD DISPLAY WILL SHOW ERROR AND THE SAFE WILL BE LOCKED
FOR 3MINUTES.AFTER 3MINUTES THE SAFE WILL RETURN TO
NORMAL OPERATION MODE.
•W
HEN THE LCD DISPLAY SHOWS LO-BAT IT IS HIGHLY
RECOMMENDED TO CHANGE THE BATTERIES AS SOON AS POSSIBLE.
USER’S MANUAL
FOR
ELECTRONIC SAFE
MODELS:
HD-20, HD-23, HD-25, HD-34, HD-45, HD-
53, HD-63A, HD-63B, HD-63C, HD-73, HD-
100, HD-120, HD-150, HD-34C
REV.092606
4