Thank you for selecting iProvén arm type Blood Pressure Monitor BPM-2244BT. The
device features blood pressure measurement, pulse rate measurement and the me-
mory function of the measurement results for two users. The device is also equipped
with Bluetooth. The iProvèn Health app will help you get even more insight in your
measurement results.
Readings taken by the BMP 2244 BT are equivalent to those obtained by a trained
observer using the cu and stethoscope auscultation method.
This manual contains important safety and care information, and provides step by
step instructions for using the product. Read the manual thoroughly before using the
product.
It is our passion to develop high quality products for home use. Our products are
manufactured at the highest technical standards of professional quality, durability, and
consistency. They are also designed with elegant simplicity in mind, making them easy
to use at home.
To help you get the most from our products, we provide clear instructions with each
device. The manual also includes helpful information that contributes to your overall
health awareness. In order to make sure that our products are tailored to your needs,
we welcome your feedback. If you have any issues, questions or recommendations,
please share your thoughts with us at www.iproven.com
iProvèn - Professional Care Brought Home
iProvèn is a Masena Invest Company

- 3 -
Table of Contents
• INTRODUCTION
• General Description
• Indications for Use
• Contraindications
• Measurement Principle
• Safety Information
• LCD Display Signal
• Monitor Components
BEFORE YOU START
• The Choice of Power Supply
• Installing and Replacing the Batteries
• Setting Date, Time, and Measurement Unit
• Pair-up the Blood Pressure Monitor with Your Devices
DATA MANAGEMENT
• Recall the Records
• Delete the Records
• Data Transmission
ABOUT BLOOD PRESSURE
• What are systolic pressure and diastolic pressure?
• What is the standard blood pressure classication?
• Why does my blood pressure uctuate throughout the day?
• Why do I get a dierent blood pressure at home compared to the hospital?
• Is the result the same if measuring on the right arm?
TROUBLESHOOTING
SPECIFICATIONS
AUTHORIZED COMPONENTS
CONTACT INFORMATION
COMPLIED STANDARDS LIST
FCC STATEMENT
EMC GUIDANCE

- 4 -
Indications for Use
1. The iProvèn Blood Pressure Monitor is digital monitors intended for use
in measuring blood pressure and heartbeat rate with arm circumference ranging
from 8¾˝ to 16½˝ (22 cm to 42 cm)
2. The monitor detects the appearance of irregular heartbeats during measurement
and gives a warning signal with readings.
3. It is intended for adult use in the home/domestic setting only.
Contraindications
1. The device is contraindicated for any person who is connected to a wearable or
implantable electronic device or instrument such as a pacemaker or debrillator.
2. The device is not intended to be a diagnostic device. Contract your physician if
hypertensive values are indicated.
Measurement Principle
This product uses the Oscillometric Measuring method to detect blood
pressure. Before every measurement, the unit establishes a“zero pressure”
equivalent to the air pressure. It then starts to inate the arm cu, while the
unit detects pressure oscillations generated by beat-to-beat pulsations, which
are used to determine the systolic and diastolic pressure as well as pulse
rate. The device also compares the longest and shortest time intervals of
detected pulse waves to the mean time interval and then calculates the
standard deviation. The device will display a warning signal with the reading
to indicate the detection of irregular heartbeat when the dierence between
the time intervals is excessive.
Safety Information
The below icons may appear in the user manual, on labeling, or on other components.
They are the required standard for use.

- 5 -
This device is intended for adult use only. This device is intended for none-invasive
measuring and monitoring of arterial blood pressure. It is not intended for use on
extremities other than the arm or for functions other than obtaining a blood pressure
measurement. Do not confuse self-monitoring with self-diagnosis. This unit allows
you to monitor your blood pressure. Do not begin or end medical treatment without
asking a physician for treatment advice. If you are taking medication, consult your
physician to determine the most appropriate time to measure your blood pressure.
Never change a prescribed medication without consulting your physician.
When the device is used to measure patients with common arrhythmias, such as atrial
or ventricular premature beats or atrial brillation, the best results may occur with
deviation. Please consult your physician about the result.
If the cu pressure exceeds 40 kPa (300 mmHg), the unit will automatically deate.
Should the cu not deate when pressure exceeds 40 kPa (300 mmHg), detach the
cu from the arm and press the corresponding user button to stop ination.
This equipment is not AP/APG equipment and is not suitable for use in the presence
of a ammable anesthetic mixture with air or with oxygen or nitrous oxide.
The operator shall not touch output of batteries /adapter and the patient simulta-
neously. To avoid measurement errors, please avoid strong electromagnetic elds,
radiated interference signal, or electrical fast transient/burst signal.
The user must check that the equipment functions safely and see that it is in proper
working order before use. This device is contraindicated for any female who may be,
suspects she is, or is pregnant. Aside from providing inaccurate readings, the eects of
this device on the fetus are unknown. Manufacturer will make available upon request
circuit diagrams, component parts list, etc. This unit is not suitable for continuous
monitoring during medical emergencies or operations. Otherwise, the patient’s arm
and ngers will become numb, swollen, or even purple due to lacking blood supply.
Please use the device in the environment indicated in the user manual. Otherwise, the
performance and lifetime of the device will be impacted and reduced. During use, the
patient will be in contact with the cu. The materials of the cu have been tested and
have been found to comply with requirements of ISO 10993-5:2009 and ISO:2010. It
will not cause any potential sensitization or irritation reaction. Please use ACCESSO-
RIES and detachable parts specied/authorized by the MANUFACTURER. Otherwise, it
may cause damage to the unit or danger to the user/patients.
The device doesn’t need to be calibrated within the two years of reliable service.
Please dispose of ACCESSORIES, detachable parts, and the ME EQUIPMENT accor-
ding to local guidelines. If you have any problems with this device, such as setup,
maintenance, or use, please contact the iProvèn SERVICE PERSONNEL. Don’t open or
repair the device by yourself. Please report to IProvèn if any unexpected operations or
events occur. Please use a soft cloth to clean the whole unit. Don’t use any abrasive or
volatile cleaners.
CAUTION

- 6 -
LCD Display Signal
Monitor Components Features:
92mm x 78mm blue LCD
display with white backlight

- 7 -
List
Installing and Replacing the Batteries
1. Open the battery cover.
2. Insert the batteries according
to the polarity indications.
3. Close the battery cover.
Replace the batteries under following circumstances:
• displays on the LCD.
• The LCD display dims.
• When powering on the monitor, the LCD doesn’t light up.
• Remove batteries if the device is not likely to be used for some time.
• Worn batteries are harmful to the environment. Do not dispose with daily garbage.
• Remove the old batteries from the device following your local recycling guidelines.
• Do not dispose of batteries in re. Batteries may explode or leak.
CAUTION
(BPM-2244BT)

- 8 -
Setting Date, Time and Measurement Unit
Please proceed to time setting before your initial use, so as to ensure that
each record is labeled with a time stamp. (The setting range for year is
2012~2052; Time format is 24H.)
1: When the monitor is OFF, press and
hold “User 1” button to enter Time
Setting Mode.
2: As pictured in the right, the blinking
numeral representing [YEAR]. Press
button to change the numeral. Each
press will increase the numeral by one
in a cycling manner.
4: .Repeat steps 2 and 3 to conrm
[MONTH] and [DAY].
3: Press “User 1” button again to
conrm [YEAR]. Then the numeral
representing [MONTH] blinks.

- 9 -
5: Repeat steps 2 and 3 to
conrm [HOUR] and [MINUTE].
6: Repeat steps 2 and 3 to conrm the measurement unit or mmHg or kPa.
7: After conrming the measurement
unit, the LCD will display “DONE” and
the monitor will shut o.

- 10 -
Pair-up the Blood Pressure Monitor with Your Device
Before you start pairing, download the iProvèn Health app from the Apple appstore
or Google playstore; search for: iProvèn Health.
1. Turn on Bluetooth and open the app on your smartphone.
2. When the monitor is OFF, press and hold the button (User 2) to start
pairing. The below symbols will be shown on the LCD alternatively, indicating
pair-up is proceeding.
3. Then please select the user ID you want to connect with your
mobile device on the app to continue the pair-up.
4. The monitor will shut o after Pair-up
process is complete.
Notes: List of compatible devices:
For iOS devices: The operating system must
be iOS 8 or more, such as iPhone 4S,
iPhone 5/5C/5S, iPhone 6/6 Plus and so on.
For Android devices: The operating system
must be 4.3 or higher.
I SUCCEED, symbol will be
shown on the LCD.
If FAIL, symbol will
be shown on the LCD.
Bluetooth Module No.: AW8001
RF Frequency Range: 2402 MHz to
2480 MHz
Output Power Range: 0 dBm
Supply Voltage: 1.8-3.6 V
Transmitting Distance: 10 meters

- 11 -
Fastening the Cu
1. Wrap the cu around your upper arm, then
position the tube o-center toward the inner
side of arm in line with pinky nger.
Or position the artery mark over the main
artery (on the inside of your arm).
Note: Locate the main artery by pressing with
2 ngers approximately 2 cm above the bend of
your elbow on the inside of your left arm. Identify
where the pulse can be felt the strongest.
This is your main artery.
2. The cu should be snug but not
too tight. You should be able to insert
one nger between the cu and
your arm.
3. Sit comfortably with your left arm
resting on a at surface.
Rest for 5 minutes before measuring.
Wait at least 3 minutes between measurements.
This allows your blood circulation to recover.
For a meaningful comparison, try to measure
under similar conditions.
For example, take daily measurements
at approximately the same time, on
the same arm, or as directed
by a physician.

- 12 -
Start Measurement
When the monitor is o, press the User 1 button to turn on the monitor, and it will
nish the whole measurement and then save the measured data for User 1 . The same
for User 2 . Take user 1 for example.
1. When the monitor is o,
press the User 1 button to
turn on the monitor
LCD display Adjust to zero
Inating and measuring. Display and save the results.
The data transmission will
proceed.
2. Press the User 1 button to power o,
otherwise it will turn o within one minute.
Tips:
A. After nishing the whole measurement, press another user button, and the
blood monitor will begin measuring again.
B. Maximum 60 records can be saved both for user 1 and user 2.

- 13 -
Recall the Records
1. When the monitor is OFF, press button
to access the memory.
2. The LCD will display the latest measuring result of the user
ID which completes the last measurement.
* The record number, measuring date and measuring
time will be displayed alternatively.
3. Press button to rotate the history records.
4. When in the memory mode, press the User 1 button to recall the measurement
history of User 1, or press the User 2 button to recall the measurement history of User 2.
5. When no history stored for the specic user in
the monitor, press button and the LCD will
display as pictured to the right.
The Order Number of
the measurement is 1.
20 records in total.
The corresponding
date is August 8th.
The corresponding
time is 16:01.
The most recent record (1) is shown rst. Each new measure-
ment is assigned to the rst (1) record. All other records are
pushed back one digit (e.g., 2 becomes 3, and so on), and the
last record (60) is dropped from the list.
CAUTION

- 14 -
Delete the Records
1.When under the memory mode, press and hold
button for 3 seconds to clear the memory.
2.When the LCD display “dEL ALL”, press
button to conrm.
4.If you wish to stop clearing the memory, you may press the other button, rather than
button to turn o the monitor, or wait until the monitor shuts o.
Data Transmission
1. With LS802-B successfully pair-up with your mobile device, the measurement data
will be automatically transmitted to your mobile device via Bluetooth.
2.The symbol will disappear after successful data transmission, and you may
check your personal health data stored in your mobile device.
3.If the data transmission fails, the symbol will remain. The pending measurement
data will be transmitted to your mobile device when next measurement is complete.
3.The LCD will display “dEL dOnE”
and then shut o.
Interference may occur in the vicinity of equipment marked with the following symbol
and BPM-2244BT may be interfering vicinity electrical equipment. Sensitive people, including
pregnant women pre-eclamptic and those who implanted medical electronic instruments,
should avoid using the unit whenever possible. Keep the monitor at least 20 centimeters away
from the human body (especially the head) when the data transmission is proceeding after
measurement. To enable the data transmission function, this product should be paired to
Bluetooth end at 2.4 GHz.
How to mitigate possible interference?
1. The range between the device and BT end should be reasonably close, from 1 meter to 10
meters. Please ensure no obstacles between the device and BT end so as to obtain quality
connection and to lower the RF output range.
2. To avoid interference, other electronic devices (particularly those with wireless
transmission / Transmitter) should be kept at least 1 meter away from the monitor.
CAUTION

3.The LCD will display “dEL dOnE”
and then shut o.
Tips for Measuring
Measurements may be inaccurate if taken under the following
circumstances.

- 16 -
Maintenance
To obtain the best performance, please follow instructions below.
Place in a dry place and
avoid sunshine
Avoid shaking andcollisions
Use a slightly damp cloth to
remove dirt.
Avoid immersing in water. Clean with
a dry cloth as needed.
Avoid dusty environments and
unstable temperature surroundings.
Avoid washing the cu.

- 17 -
What are systolic pressure and diastolic pressure?
When ventricles contract and pump
blood out of the heart, the blood pressure
reaches its maximum value in the cycle,
which is called systolic pressure. When
the ventricles relax, the blood pressure
reaches its minimum value in the cycle,
which is called diastolic pressure.
Irregular Heartbeat Detection
An irregular heartbeat is detected when a heartbeat rhythm varies while the unit is
measuring the systolic and diastolic blood pressure. During each measurement, this
equipment records the heartbeat intervals and works out the standard deviation. If the
calculated value is larger than or equal to 15,the irregular heartbeat symbol appears
on the symbol when the measurement results are displayed.
The appearance of the IHB icon indicates that a pulse irregularity consistent with an irregular
heartbeat was detected during measurement. Usually this is NOT a cause for concern. However,
if the symbol appears often, we recommend you seek medical advice. Please note that the
device does not replace a cardiac examination, but serves to detect pulse irregularities at an
early stage.
CAUTION
What is the standard blood pressure classification?
Only a physician can tell your normal BP range. Please
contact a physician if your measuring result falls out of the
range. Kindly note that only a physician could tell whether
your blood pressure value has reached a dangerous point.
The blood pressure classification published by
World Health Organization (WHO) and
International Society of Hypertension (ISH) in
1999 is as follows:
SYS
DIA
<120
<80
120-129
80-84
130-139
85-89
140-159
90-99
160-179
100-109
≥180
≥110
Level
Blood
Pressure (mm Hg)
Optimal Normal High-normal Mild Moderate Severe
CAUTION

- 18 -
Why does my blood pressure uctuate
throughout the day?
1. Individual blood pressure varies
multiple times everyday. It is also
aected by the way you tie your cu
and your measurement position, so
please take the measurement under
the same conditions.
2.If the person takes medicine, the
pressure will vary more.
3.Wait at least 3 minutes for
another measurement.
Why do I get a dierent
blood pressure at home
compared to the hospital?
The blood pressure is dierent even
throughout the day due to weather,
emotion, exercise etc, Also, there is
the “white coat” eect, which means
blood pressure usually increases in
clinical settings.
Is the result the same
if measuring on the
right arm?
It is ok for both arms, but there
will be some dierent results for
dierent people. We suggest you
measure the same arm every time.
What you need to pay
attention to when you measure
your blood pressure at home:
If the cu is tied properly.
If the cu is too tight or too loose.
If the cu is tied on the upper arm.
If you feel anxious.
Taking 2-3 deep breaths before
beginning will be better for measuring.
Advice: Relax yourself for 4-5
minutes until you calm down.

- 19 -
This section includes a list of error messages and
frequently asked questions for problems you may
encounter with your blood pressure monitor.
If the products not operating as you think it should,
check here before arranging for servicing.
What you need to pay
attention to when you measure
your blood pressure at home:
If the cu is tied properly.
If the cu is too tight or too loose.
If the cu is tied on the upper arm.
If you feel anxious.
Taking 2-3 deep breaths before
beginning will be better for measuring.
Advice: Relax yourself for 4-5
minutes until you calm down.

- 20 -
WARNING: No modication of this equipment is allowed.
Table of contents