PST U0110 Instruction manual

COMET SYSTEM, s.r.o., Bezrucova 2901 Specifications aresubject to change without notice.
756 61 Roznov pod Radhostem, Czech republic ie-lgr-n-Uxxxx-a-09
Dataloggers - Uxxxx family
QUICK START MANUAL
U0110 •U3120 •U3430 •U4130 •U4440• U8410
PRODUCT DESCRIPTION
The dataloggers Uxxxx with internal sensors are designed for measuring and recording physical and electric quantities with an
adjustable logging interval from 1 second to 24 hours. The measured values, or the average values and min/max values over a recording
interval are stored into the internal non-volatile memory. The data logging mode can be cyclic (when the data memory is completely full,
the oldest data are overwrite by the new ones), or non-cyclic (the recording will stop once the memory is full). The device also allows to
the evaluation of alarm states - exceeding the limit of the measured value or falling below this limit, exceeding the limit of memory filling,
technicaldefectsof theinstrument orprobes.The alarmsignallingcan berealisedvisually,optionally byasymbolappearing onthedisplay
orbya shortblinkofanLED,oracoustically.Thedatarecording canbeperformedcontinuouslyor onlywhenanalarmoccurs. Thedevices
are powered by internal a replaceable lithium battery (U0110, U3120, U4130) or by internal Li-Ion battery (U4130, U4440, U8410).
Device setting, recorded data downloading and online monitoring is carried out using the computer with the COMET Vision software
installed (see www.cometsystem.com). The USB interface is used to communicate with the computer.
Device type
Measured values
Construction
U0110
Ti
Internal temperature sensor
U3120
Ti + RH + Td + 1x cc
Internal temperature and relative humidity sensor
U3430
Ti + RH + Td + CO2 + 1x cc
Internal sensors of temperature, relative humidity and CO2 concentration
U4130
Ti + RH + Td + P + 1x cc
Internal sensors of temperature, relative humidity and barometric pressure
U4440
Ti + RH+ Td + P + CO2 + 1x cc
Internal sensors of temperature, relative humidity, barometric pressure and CO2concentration
U8410
CO2
Internal sensor of CO2concentration
Ti…Temperature, RH…Relative humidity, Td…Dew point temperature, P… Barometric pressure, CO2…CO2 concentration
cc… calculated channel, ie the channel that can be used to calculate and record the value calculated from the measured quantities according to the selected formula
INSTALLATION AND OPERATION
Fasten the device on the wall with two screws or insert it into the wall holder LP100 (optional accessory). Datalogger may be operated
as a portable one. In this kind of operation avoid the device falling down. Try to maintain the proper working position.
Please pay attention to the device mounting. Inappropriate selection of the working position and the measurement location may
adversely affect the accuracy and long-term stability of the measured values.
The device should be located as far as possible from potential interference sources
Set-up the device
Device setup can be performed using the computer with the Windows 7 operational system or higher. Minimum HW requirements
are 1.4 GHz processor and 1 GB memory.
Install the COMET Vision software into computer (the program is available free of charge at www.cometsystem.com)
Connectthedataloggertothe computer.UseanUSBcablewithUSB-Cconnector(max.cable length3m).Ifthedeviceisconnected
properly, its current status is displayed in the Device Home panel.
Click on the Configuration button. The device configuration will be downloaded and you can change the settings of some items.
Save the new configuration into the device
Disconnect the device from the computer and close the USB connector with a closing cap
Operating the device from the keypad
Press and hold the lower key. After the light up the row with menu items, release the key and briefly press the upper key.
Press the upper key to scroll through the menu items (device turning On/Off, deleting the Min/Max values in the device, …)
Press the lower key to confirm (SET)
The devices do not require special maintenance. We recommend verifying the measurement accuracy regularly by calibration.
SAFETY INSTRUCTIONS
-Installation, electrical connection and commissioning should only be performed by qualified personnel in accordance
with applicable regulations and standards
-DevicesU3430, U4440 andU8410 are equipped with aninternal Li-Ion battery. Observethe recommended operating
andstoragecondition.Shouldthebatterycasinggetdamagedorshouldthewholedevicegetdestroyed,carryitoutside
the fire, high temperature or water affected area to a safe fire-protected place. Protect yourself and the environment
against escaping gases and against being soiled with the battery electrolyte.
-The battery charging of the U3430, U4440 and U8410 devices will proceed at an indoor temperature ranging between
0°C and +40°C (the device has to be located in an indoor room with a relative humidity up to 85%). Fast charge mode
can be run by turning off the device.
-Devices contain electronic components, it needs to liquidate them according to currently valid conditions
-To complement the information in this data sheet read the manuals and other documentation, which are available
in the Download section for a particular device at www.cometsystem.com

Authorized Distributor in Australia & New Zealand
Pacific Sensor Technologies Pty Ltd
Unit 4, 3 Neutron Place Rowville, VIC 3178 Australia
1300 662 720 | [email protected]
www.pacificsensortech.com.au
This manual suits for next models
5
Table of contents
Other PST Data Logger manuals