PulseWorx PIM-R User manual

Model: PIM-R
Powerline Interface Module
Installation Guide and
Owner’s Manual
The Inventors Of:
19215 Parthenia St. Suite D
Northridge, CA 91324
P: 818-701-9831 pcssales@pcslighting.com
https://pcswebstore.com www.pcslighting.com
FUNCTION
The PIM-R Powerline Interface Module – RS232 is the de facto
interface between a computer (or other serial device) and the
Universal Powerline Bus (UPB). The PIM-R connects to a serial
(COMM) port on your computer with a standard serial cable
(provided) and sends and receives UPB communication
packets on the existing house wiring. The PIM-R can be
plugged into any free wall outlet throughout the home. The
device also provides a pass-thru outlet for other electronic
devices. No additional wiring is required and no radio
frequency signals are used for communication.
TYPICAL USES
The PIM-R is perfect for interfacing devices with a serial port to
the UPB powerline. Typical applications are:
•UPB Setup Tool (UPStart) Interface
•Home Automation Controller Interface
•Thermostat Interface
•Alarm Panel Interface
•Sprinkler Controller Interface
IMPORTANT SAFETY INSTRUCTIONS
When using electrical products, basic safety precautions
should always be followed, including the following:
1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
2. Keep away from water. If the product comes in contact
with water or other liquid, turn off the circuit breaker and
unplug the product immediately.
3. Never use products that have been dropped or damaged.
4. Do not use this product outdoors.
5. Do not use this product for other than its intended
purpose.
6. To avoid any risk of fire, burns, personal injury or electric
shock, install this product out of the reach of small
children.
7. Do not cover this product with any material when in use.
8. This product uses grounded plugs and sockets to reduce the
risk of electric shock. These plugs and sockets fit only one
way. If they do not fit, consult an electrician.
9. SAVE THESE INSTRUCTIONS.
INSTALLATION
The Powerline Interface Module is designed for indoor use with
devices that provide an RS-232 serial port. To install the PIM-R
module follow these steps:
1. Connect the serial cable (provided) between the PIM’s serial
connector and any open COMM port of the computer or
laptop.
2. Plug the PIM-R into any grounded wall outlet.The Status
LED should start blinking and then stay solid blue.
NOTE: The PIM-R requires the DTR signal (pin 4) from the host
device to be at RS-232 logic high. This is the typical configuration
for most PC’s and laptops but may not be typical for other serial
devices. Check with the manufacturer of the serial device to
verify that it supplies positive DC voltage on this pin.
OPERATION
The PIM-R is the perfect interface device for use with PCS’ UPStart
Setup Software. UPStart allows you to easily configure all of your
PulseWorx System devices. The UPStart User’s Guide (available
on the PulseWorx web site: www.PulseWorx.com) explains how
to configure your system using UPStart software.
To use the PIM-R with UPStart select ToolsUPB Interface
DeviceSelect to bring up the UPB Interface Setup dialog.
Model: PIM-R
Powerline Interface Module
Installation Guide and
Owner’s Manual
The Inventors Of:
19215 Parthenia St. Suite D
Northridge, CA 91324
P: 818-701-9831 pcssales@pcslighting.com
https://pcswebstore.com www.pcslighting.com
Select the “Powerline Interface Module” as the Interface and
then press the “Find UPB Interface port” button. UPStart will
automatically find the Communication Port that the PIM-R is
connected to. Next, press the “Connect” button to have
UPStart connect and test the PIM-R.
Signal & Noise Meters
Once connected, the PIM-R will constantly send reports to
UPStart as to what is currently happening on the powerline.
You can get a peek into the results of these reports by pressing
the Signal & Noise Meters button to bring up the UPB
Interface Diagnostics shown below.
The meters will display a real-time indication of what the PIM-
R is reporting. UPStart will also classify the reports as either
“Signal” or “Noise” and display them on the proper meter.
The meters are very useful for troubleshooting problems on
the powerline.
Status LED Indications
The PIM-R contains a bi-color (blue/red) Status LED that will
also give a visual indication of what UPB information is
currently on the powerline.
Blue:
No UPB Signal
Magenta:
Received a UPB Message
Red:
Transmitted a UPB Message
Push-button
The push-button on the front of the PIM-R is used to put the
device back to its factory default condition. To set the PIM-R back
to factory defaults first press the pushbutton 5times rapidly. The
Status LED will blink blue. Next, press the pushbutton 10 times.
The Status LED will blink red. Finally, press the pushbutton 2
times. The Status LED will stop blinking. The device is now
restored to its factory default state.
CONFIGURATION
The PIM-R has an adjustment for UPB receive sensitivity. The
factory default for this setting is “High”. If the PIM-R is to be used
in severe powerline noise, you may find that it operates better in
the “Low” receive sensitivity setting.
To adjust the receive sensitivity press the “Settings” button on the
UPB Interface Setup dialog. Next, select the desired receive
sensitivity setting and press the “OK” button.
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all
applicable instructions, to be free from original defects in
materials and workmanship for a period of five years from the
date of purchase. Refer to the warranty information on the
PulseWorx website (www.PulseWorx.com) for exact details.

Other PulseWorx Control Unit manuals

PulseWorx PIM-E User manual

PulseWorx

PulseWorx PIM-E User manual

PulseWorx AM1 User manual

PulseWorx

PulseWorx AM1 User manual

PulseWorx DBM User manual

PulseWorx

PulseWorx DBM User manual

Popular Control Unit manuals by other brands

RS PRO 209-6384 Instruction leaflet

RS PRO

RS PRO 209-6384 Instruction leaflet

Channel Vision Central C-0508 manual

Channel Vision

Channel Vision Central C-0508 manual

Leadshine Technology Co. 3DM580 user manual

Leadshine Technology Co.

Leadshine Technology Co. 3DM580 user manual

AvaLAN AW5800m-SR user manual

AvaLAN

AvaLAN AW5800m-SR user manual

Elsist SlimLine PCB124 00 Series Hardware manual

Elsist

Elsist SlimLine PCB124 00 Series Hardware manual

Burkert 2101 quick start

Burkert

Burkert 2101 quick start

Texas Instruments BQ76905 user guide

Texas Instruments

Texas Instruments BQ76905 user guide

Eddyfi Technologies INUKTUN MINITRAC 8000 user manual

Eddyfi Technologies

Eddyfi Technologies INUKTUN MINITRAC 8000 user manual

Chandler Systems D15 manual

Chandler Systems

Chandler Systems D15 manual

National Instruments NI 9861 operating instructions

National Instruments

National Instruments NI 9861 operating instructions

GAPOSA QC100U manual

GAPOSA

GAPOSA QC100U manual

Burkert 6213 operating instructions

Burkert

Burkert 6213 operating instructions

Sonnet RackMac Pro installation instructions

Sonnet

Sonnet RackMac Pro installation instructions

MSA GasGard XL operating manual

MSA

MSA GasGard XL operating manual

Emerson Sempell series operating instructions

Emerson

Emerson Sempell series operating instructions

Samsung MCU Series installation manual

Samsung

Samsung MCU Series installation manual

ThingMagic Mercury6e M6e-30dBm Hardware guide

ThingMagic

ThingMagic Mercury6e M6e-30dBm Hardware guide

NET NET-CKD user manual

NET

NET NET-CKD user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.