Runxin F71B1 User manual

Multi-functional Flow Control Valve for
Water Treatment Systems
53502(Old Model No.: F71B1)
53502B(Old Model No.:F71G1)
53504(Old Model No.:F67C1)
53504B(Old Model No.:F67G1)
53510(Old Model No.:N75A1)
53510B(Old Model No.:N75B1)
User Manual
Please read this manual in details before using the valve
and keep it properly in order to consult in the future.
0WRX.466.508
China Patent No.: ZL02220153.X,
ZL02257746.7

MODEL F71B/F71G/F67C/F67G/N75A/N75B
Before the valve put into use, please fill in the below content so as to
help us to refer in the future.
Filter System Configuration
Tank Size: Dia. mm
Height mm
Refilled Filter Materials Kg
Granularity of Filter Materials mm
Control Valve Model
Number
Pressure of Inlet Water MPa
Turbidity of Inlet Water FTU
Water Source: Ground-water□;Filtered Ground-water □;
Tap Water □;Other .
Parameter Set
Parameter
Unit
Factory
Default
Actual Value
Service Days(Time clock type,
by days)
D.
03
Service Hours (Time clock
type, by hours)
H.
20
Rinsing Time
/
02∶00
Rinsing Frequency
/
F-00
Backwash Time
Min.
10
Fast Rinse Time
Min.
10
Output Mode b-01(02)
/
b-01

MODEL F71B/F71G/F67C/F67G/N75A/N75B
Catalogue
Notice......................................................................................................
1. Product Overview .............................................................................
1.1. MainApplication& Applicability............................................
1.2. Product Characteristics .........................................................
1.3. Service Condition...................................................................
1.4. Product Structure and Technical Parameters ....................
1.5. Installation................................................................................
2. Basic Setting & Usage .....................................................................
2.1. The Function of PC Board....................................................
2.2. Basic Setting & Usage...........................................................
3.Applications........................................................................................
3.1. Filter Flow Chart................................................................17
3.2. The Function and Connectionof PC Board.......................
A. Signal Output Connector...................................................
B. Interlock ...............................................................................
C. Pressure Relief Output......................................................
D. Remote Handling Connector............................................
3.3. System Configuration and Flow Rate Curve......................
3.4. Parameter Enquiryand Setting............................................
3.5. Trial Running...........................................................................
3.6. Trouble-Shooting ....................................................................
3.7.Assembly& Parts...................................................................
4. Warranty Card...................................................................................

MODEL F71B/F71G/F67C/F67G/N75A/N75B
2
Notice
To ensure normal operation of the valve, please consult with
professionalinstallation or repairing personnel before use it.
If there are any of pipeline engineering and electric works, there must
be finished by professionalat the time of installation
Do not use the control valve with the water that is unsafe or unknown
quality.
Depending on the changing of working environment and water
requirement, each parameter of filter should be adjusted accordingly.
Test water periodicallyto verify that system is performing satisfactorily.
Do not put the valve near the hot resource, high humidity, corrosive,
intense magnetic field or intense librations environment. And do not
leave it outside.
Forbidden to use the drain pipeline or other connectors as support to
carry the system.
Please use this product under the water temperature between 5~50℃,
water pressure 0.15~0.6MPa. Failure to use this product under such
conditions voids the warranty.
If the water pressure exceeds 0.6Mpa, a pressure reducing valve must
be installed before the water inlet. While, if the water pressure under
0.15MPa, a booster pump must be installed before the water inlet.
It is suggested to install PPR pipe, corrugated pipe or UPVC pipe,
instead of TTLSG pipe.
Do not let children touch or play, because carelessness operating may
cause the procedure changed.
When the attached cables of this productand transformer are changed,
they must be changed to the one that is from our factory.
For 53510(N75A) and 53510b(N75B1) product, in order to dismantle

MODEL F71B/F71G/F67C/F67G/N75A/N75B
3
easily, itis suggested to installthe strainer with M88×2 male thread.
1. Product Overview
1.1. MainApplication&Applicability
Used for filtering water treatment systems
Be suitable for
Residential filtering system
Swimming pool filtering equipment (N75A1/53510,
N75B1/53510B)
Carbon filter or sand filter in RO pretreatment filtering system
1.2. ProductCharacteristics
Simple structure andreliable sealing
It adopts hermetic head faces with high degree pottery and
corrosion resistance for opening and closing. It combines with Service,
Backwash, and Fast Rinse.
No water pass the valvein rinsingin single tanktype
Manual function
Realize rinsing immediately by pressing “ ” at any time.
Long outage indicator
If outage overrides 3days, the time of day indicator “12:12”will flash
to remind people to reset new time of day. The other set parameters do
not need to reset. The processwill continue to work after power on.
LED dynamic screen display
The stripe on dynamic screen flash, it indicates the control valve is
in service; otherwise, it is in rinsing cycle.
Buttons lock

MODEL F71B/F71G/F67C/F67G/N75A/N75B
4
No operations to buttons on the controller within 1 minute, button
lock indicator light on which represent buttons are locked. Before
operation,press and hold the “ ”and“ ” buttons for 5 seconds to
unlock. Thisfunction can avoid incorrect operation.
Rinsing frequency
It could set up multiple rinsing times, which means several times of
backwash and fast rinse but one time of service. It is much better for
cleaning the filter materials.
There are two kinds of time clock types
Time clock type valve can be chosen to be service by hours ,by
dialing the red switch on main control board to “1” (Refer to the Figure
3-1). Pointing to “ON” mean the time clock type service by days; “1”
means the time clock type service by hours.(Attention: after dialing the
switch, please restart the power)
Interlockfunction
It has a function of interlock to realize only one valve in rinsing, but
the other valves are in service while there are several valves parallel in
system. In multi-steps treatment systems such as RO pre-treatment,
when several valves are in series, there is only one valve in rinsing to
ensure pass water all the times while different valves in
rinsing.(Application refer to Figure 3-10)
Signal output
There is a signal output connector on main control board. It is for
controlling external wiring ( Refer to Figure from Figure3-2 to Figure 3-9).
There are two kinds of output modes. b-01 Mode: Turn on start of
regeneration and shut off end of regeneration; b-02 Mode: Signal
available only intervals of rinsing cycles and In service.

MODEL F71B/F71G/F67C/F67G/N75A/N75B
5
b-01
b-02
Remote handling input
This connector can receive external signal, used together with PLC,
and computer etc. to control the valve. (Application refer to Figure3-12)
Pressure reliefoutput
The valve will cut off feeding water to drain line when it switches in
rinsing cycles (Same as signal output b-02). Thus in some water
treatment system, e.g. Deep Well, one booster pump was installed on
the inlet to increase the system water feeding pressure, this cut-off will
cause pressure on inlet rinsing too fast to damage the valve. Pressure
Relief Output can be used to avoid this problem. (Application refer to
Figure3-11).
All parameters can be modified
According to the water quality and usage, the parameters in the
processcan be adjusted.

MODEL F71B/F71G/F67C/F67G/N75A/N75B
6
1.3. ServiceCondition
Filter Valve should be used under the belowconditions:
Items
Requirement
Working
conditions
Water pressure
0.15MPa~0.6MPa
Water temperature
5℃~50℃
Working
environment
Environment
temperature
5℃~50℃
Relative humidity
≤95%(25℃)
Electrical facility
AC100~240V/50~60Hz
Inlet water
quality
Water turbidity
<20FTU
Note:
The parameter in the above chart is only suitable for the filter matched
with our filter valves.
When the water turbidity exceeds the conditions, the impurity in the
inlet water should be coagulated and precipitated firstly.
1.4. ProductStructureandTechnicalParameters
Dimension
(The appearance is just for reference. It is subjected to the real product)

MODEL F71B/F71G/F67C/F67G/N75A/N75B
7
Model
A(mm)
max
B(mm)
max
H(mm)
max
Transformer
Output
FlowRate
m3/h
@0.3MPa
F71B(53502)
182.5
195.5
143
DC12V,
1.5A
2.0
F71G
(53502B)
199
180
167

MODEL F71B/F71G/F67C/F67G/N75A/N75B
8
Model
A(mm)
max
B(mm)
max
H(mm)
max
Transformer
Output
FlowRate
m3/h
@0.3MPa
F67B(53504)
180
194
178.5
DC12V,
1.5A
4.0
F67G
(53504B)
242
204
198
Model
A(mm)
max
B(mm)
max
H(mm)
max
Transformer
Output
FlowRate
m3/h
@0.3MPa
N75A(53510)
220
346.5
230.5
DC24V,
1.5A
10.0
N75B
(53510B)
216.5
346.5
247

MODEL F71B/F71G/F67C/F67G/N75A/N75B
9
1.5. Installation
A. Installation notice
Before installation, read all those instructions completely. Then
obtain all materials and tools needed for installation.
The installation of product, pipes and circuits should be
accomplished by professional to ensure the product can operate
normally.
Perform installation according to the relative pipeline regulations
and the specification of Water Inlet, Water Outlet, and Drain Outlet.
B. Device location
①The filter should be located closely to drain.
②Ensure the unit is installed in enough space for operating and
maintenance.
③The unit should be kept away the heater, and exposed outdoor.
Sunshine or rain will cause the system damage.
④Please avoid to install the system in one Acid/Alkaline, Magnetic or
strong vibration circumstance, because above factors will cause the
system disorder.
⑤Do not install the filter, drain pipeline in circumstance which
temperature may drop below 5℃, or above 50℃.
⑥One place is recommended to install the system which causes the
minimum loss in case of water leaking.
C. Pipeline connection (Taking F71B for example)
①Install control valve
a.As the figure1-1shows, select the relevant riser pipe, glue the riser pipe
to the bottom strainer and put it into the mineral tank, cut off the
exceeding tube out of tank top opening. Plug the riser tube in case of
mineral entering.

MODEL F71B/F71G/F67C/F67G/N75A/N75B
10
b.Fill the mineral to the tank, and the height is accordance with the
design code.
c.Remove the tap covering on the central tube and check if the riser tube
is on the central of tank.
d.Install the top distributor to the valve and insert the riser tube into
control valve and screw tight controlvalve.
Note:
●The length of riser tube should be neither higher 1mm nor lower 5mm
tank top opening height, and its top end should be rounded to avoid
damage of O-ring inside the valve.
●Avoid floccules substance together with filter materials fill in the tank.
●Avoid O-ring inside control valve falling out while rotating it on the tank

MODEL F71B/F71G/F67C/F67G/N75A/N75B
11
②Pipeline connection
a. As figure 1-2 shows, install a pressure gauge in water inlet.
b. Install valve A, valve B, valve C and valve D in the inlet and outlet
pipeline. The valve D is sampling valve.
c. Install the checkvalve in the outlet pipeline.
d. Inlet pipeline should be in parallel with outlet pipeline. Support inlet
and outlet pipeline with fixed holder.
Note:
●If making a soldered copper installation, do all sweat soldering before
connecting pipes to the valve. Torch heat will damage plastic parts.
●When turning threaded pipe fittings onto plastic fitting, use care not to
cross thread or broken valve.

MODEL F71B/F71G/F67C/F67G/N75A/N75B
12
③Install drain pipeline
Directly connect the drain with the rigid pipeline, such as UPVC, etc.
Note:
●Control valve should be higher than drain outlet, and be better not far
from the drain hose.
● Be sure not connect drain with sewer, and leave a certain space
between them (As the figure 1-3 shows), avoid waste water be absorbing
to the water treatment equipment.
●If waste water is used for other purpose, please use another container
for loading.And also keep a certain space between drain and container.

MODEL F71B/F71G/F67C/F67G/N75A/N75B
13
2. Basic Setting & Usage
2.1. TheFunctionof PC Board
A. Time of day indictor
light on, display the time of day.
B. Button lock indicator
Light on, indicate the buttons are locked. At this moment, press any
single button will not work (No operation in one minute, will light on
and lock the buttons.)
Solution:Press and hold both and for 5 seconds until the
light off.
C. Program mode indicator
Light on,enter program display mode. Use or to view all
values.
Flash, enter programset mode. Press or to adjust values.
D. Manu/Confirm button

MODEL F71B/F71G/F67C/F67G/N75A/N75B
14
Press , light on, enter program display mode and use or to
view all values.
In program display mode, press , flash, enter program set mode,
press or and adjust values.
re set, and then the voice “Di” means all setting are success and return
programdisplay mode.
E. Manual/Return button
Press in working conditions, it can proceed to next step. (Example:
when the outlet water failsto reach the requirement, you can press
to end the service and start an immediate rinsing. During the process
of rinsing, pressing the button can end one step in advance and
proceed to the next step.)
Press in program display mode, and it will return in Service; Press
in programset mode, and it will return programdisplay mode.
Press while adjusting the value, then it will return program display
mode directly without saving value.
F.Down ▼and Up▲
In program display mode, press ▲or▼ to view all values.
In program set mode, press ▲or▼ to adjust values.
Press and hold both ▲and ▼for 5 seconds to lift the Button Lock
status.

MODEL F71B/F71G/F67C/F67G/N75A/N75B
15
2.2. Basic Setting & Usage
A. Parameter specification
Function
Indicator
Factory
Default
Parameter
Set
Range
Instruction
Time of
Day
Rando
m
00:00~
23:59
Set the time of day when use;“:”
flash.
Service
Days
1-03D.
0~
99Days
Only for Time Clock Type, by days
Service
Hours
1-20H.
0~
99Hours
Only for Time Clock Type,by hours
Rinsing
Time
02:00
02:00
00:00~
23:59
Rinsing Time; “:” light on
Rinsing
Frequency
F-00
00
0~20
Rinsing frequency. For example,F01:
indicate service 1 time, backwash
and fast rinse 2 time;
Backwash
Time
10min.
0~99∶59
Backwash time(Minute), correct to
second;
Fast Rinse
Time
10min.
0~99∶59
Fast Rinse Time(Minute), correct to
second;
Output
Control
Mode
b-01
01
01 or 02
Mode 01: Signal turn on start of
rinsing and shut off end of rinsing.
(Connection refer to the Figure P5)
Mode 02: Signal available only
intervals of rinsing cycles and in
service. (Connection refer to the
Figure P5)

MODEL F71B/F71G/F67C/F67G/N75A/N75B
16
B. Process Display (Time Clock Type, by days)
Working status
The circular interface displays in turn
Service
Backwash
Fast Rinse
Illustration:
The display screen will only show “-00-” when the electrical motor is
running.
The time of day figure“” flash continuously, such as “12:12” flash,
indicates long outage of power. It reminds to reset the time of day.
The display will show the error code, such as “-E1-” when the system
is in error.
Working process: Service→ Backwash→ Fast Rinse

MODEL F71B/F71G/F67C/F67G/N75A/N75B
17
3. Applications
3.1. Filter Flow Chart

MODEL F71B/F71G/F67C/F67G/N75A/N75B
18
3.2. TheFunctionandConnectionof PC Board
Opening the front cover of control valve, you will see the main control
board and connection port as figure 3-1Ashows(For F71, F67)
This manual suits for next models
11
Table of contents
Other Runxin Control Unit manuals

Runxin
Runxin F104 A User manual

Runxin
Runxin 73605 User manual

Runxin
Runxin 63518 User manual

Runxin
Runxin 53515 User manual

Runxin
Runxin 51215 User manual

Runxin
Runxin N74Q1 User manual

Runxin
Runxin F79A-LCD User manual

Runxin
Runxin F139 User manual

Runxin
Runxin 63504 User manual

Runxin
Runxin 55504 User manual