CONFIGURATION
Once your AM1 is installed it can be configured either
manually or with the UPStart Setup Software.
Manual configuration can be used to add your AM1 device
into a UPB network and link it to controller buttons. Refer to
the Keypad Controller’s Manual Configuration Guide
available on the PulseWorx website (www.PulseWorx.com)
for more details.
Although the factory default operation of the AM1 is useful in
many situations, it is highly recommended that your device
be configured with UPStart Setup Software so that you can
take advantage of its many configurable features.
PCS has developed a Powerline Interface Module (PIM) and
free UPB Setup Tool software (UPStart) to help you configure
all of your PulseWorx Lighting System devices. User’s Guides
are available on the PulseWorx web site:
www.PulseWorx.com to explain how to configure your
system.
SETUP Mode
When configuring a UPB system, it will be necessary to place
the AM1 in SETUP mode. To do this, press the Program
Button (see illustration) five times rapidly using a non-
metallic toothpick. The Status LED will continuously blink
Blue when the device is in SETUP mode. To exit SETUP mode,
press the Program Button once or wait five minutes for it to
time out.
OPERATION
The Appliance Module operates according to commands sent
by one or more UPB controllers. The AM1 can accept
powerline commands from any UPB-compatible transmitter
such as PulseWorx Keypad Controllers, Timed Event
Controllers, Wall Switches, Interface Modules, approved
Third-Party Controllers and touch screens. The AM1 can be a
member of up to 16 scenes with the capability to store a pre-
set relay state (on, off, or blink) for each scene.
AUTO-OFF Timer
New for Generation 2 is the ability to set a maximum on time.
If you forget to shut the appliance off yourself the appliance
module will do it for you automatically. The AM1 can be
configured to inform the rest of the network when it has
automatically turned the appliance off. This allows the AM1
to remotely control other devices or update feedback
indicators such as LEDs.
TEST Mode
A manual test feature allows the device to be turned ON and OFF
locally. To enable the TEST mode press and hold the Program
Button on the AM1 for three seconds. The Status LED will
blink Magenta to indicate TEST mode. The appliance can now be
turned ON and OFF by single-tapping the Program Button. Press
and hold the Program Button again for three seconds to exit
from TEST mode.
Factory Default Settings
To restore the following default settings put the AM1 into SETUP
mode and then press the Program Button ten times rapidly. The
Status LED will blink red to indicate that factory defaults have
been restored. Press the Program Button twice more to stop the
blinking.
Network ID: 255
Unit ID: 15
Network Password: 1234
Receive Components: Link #1 = ON
Link #2 = OFF
Link #8 = Blink
TYPICAL USES
The AM1 is perfect for controlling 120VAC non-dimming loads
such as:
•Fans,
•Pumps,
•Low voltage transformers,
•Coffee makers,
•Christmas lights.
LIMITED WARRANTY
Seller warrants this product, if used in accordance with all
applicable instructions, to be free from original defects in
materials and workmanship for a period of five years from the
date of purchase. Refer to the warranty information on the
PulseWorx website (www.PulseWorx.com) for exact details.
The Inventors Of:
19201 Parthenia St. Suite J
Northridge, CA 91324
(Phone) 818-701-9831 (Fax) 818-701-1506