PureAire HVAC User manual

Owner’s Manual

2
Welcome
Table of Contents
Thank you for your purchase of the pureAir HVAC Air Purication
Enhancement System. This unit is designed to be installed into an existing
HVAC system, and used as a virtually maintenance-free enhancement to
current air purication technology.
Please read and follow all service procedures outlined in this manual.
Please record the name and phone number of your distributor or contractor.
About .......................................................... 3
Cautions & Warnings ............................................. 3
Product Contents ................................................ 4
Installation Hardware ............................................. 4
Installation Tools ................................................. 5
Installation Requirements.......................................... 5
Installation .....................................................6-7
Maintenance.................................................... 8
Cell Disposal .................................................... 8
Replacement Parts ............................................... 8
Changing the Cell ............................................... 9
Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Name_____________________________________________________________________
Phone #: __________________________________________________________________
Please record the serial number of your pureAir HVAC.
Serial #: ___________________________________________________________________

3
About pureAir HVAC
pureAir HVAC is a new generation Air Purication Enhancement System.
Designed to work with existing purication technology to reduce odors,
smoke, and a broad spectrum of indoor air contaminants.
pureAir HVAC is easily mounted into air conditioning and/or heating systems
where contaminants can grow. When the HVAC system is in operation,
pureAir HVAC produces the ARC® (Photocatalytic Oxidation) Process
consisting of hydroperoxides and superoxide ions, which are friendly oxidizers
that revert back to oxygen and hydrogen after the oxidation of a pollutant.
Cautions & Warnings
WARNING: UV Light in operation. Disconnect unit from power
supply before servicing. Failure to follow warnings may result in
severe eye damage.
CAUTION: To reduce the risk of shock, this equipment may have
a grounding type plug with a third (grounding) pin. This plug will
only t into a grounding type power outlet. If the plug does not t
into the outlet, contact a qualied electrician or HVAC specialist to
install the proper outlet. DO NOT alter the plug in any way.

4
Product Contents
Installation Hardware
Unit Diagram
(8) #8 3/4” Hex Head Self-Tapping Screw
(4) #8 - 32 Knurled Thumb Nuts
(2) #8 - 32, 3/8” Screw
(4) #6 - 32, 3” Threaded Bolt & Wall Anchor
(2) 18 - 22 Gauge Wire Nut (only used with hard-wiring)
Ballast Housing &
Mounting Plate
Replaceable ARC®Cell
(Includes UV Lamp)
Power Supply
(120 VAC to 24 VAC/VDC)
UV Bulb
Cell Mount
Screw Holes (4)
ARC®Cell
Ballast OutletAdhesive Gasket Plate
Power Outlet
Ballast Housing

5
pureAir HVAC Supply Plenum
Installation Tools
Installation Requirements
pureAir HVAC Return Plenum
(Recommended Option)
Utility Knife Tin Snips
Phillips Head Screwdriver
5/16” Wrench/Socket
Power Drill/Driver
1/8” Drill Bit
4” Hole Saw
The unit should be installed after the air handler in the
HVAC system in the supply plenum.*
*Additional pureAir HVAC units are recommended in
the Return Plenum for added protection and to keep
the internal parts clean.
An opening of 4” across will need to be cut into the
existing duct work to install the unit properly.
Electrical Requirements
The unit is powered by connection to 24VAC from
HVAC System or 24VDC from 120VAC transformer
(included).
WARNING: Long term use of an extension cord is not recommended due to safety considerations.

6
Installation
1. Locate a suitable area of duct for
the installation.
7. (A) Install the Mounting Plate to
the Duct using the Eight (8) Self-
Tapping Screws.
2. Cut away any insulation to expose
the duct.
3. Use the Mounting Plate to trace
the main hole and the eight (8)
Screw Hole Locations.
4. Use a 1/8” Drill Bit to drill the 8 screw
hole locations just marked. (If you are
using Tin Snips, add 4 additional holes
around the large marked circle.)
5. Use a 4” Hole Saw or the Tin Snips to
cut around the traced hole.
6. Unscrew the Knurled Thumb Nuts and
remove the Mounting Plate from the
unit ballast. Peel the backing from
the adhesive side and press the plate
onto the duct over the cut opening.
(B) For Fiberglass Ductwork, attach using
the 2” Bolts with Toggle Bolt Anchors.

7
Installation (Continued)
8. Orient the Ballast to allow the Power
Outlet to face the the ideal direction.
9. Align the ARC Cell’s screw holes with
the holes on the Ballast in a way which
will allows air to pass through the Cell
once mounted into the duct.
10. Mount the Cell onto the Ballast,
ensuring that the UV Bulb’s prongs
fully insert before fastening the screws.
Note: The UV bulb can only be inserted one way,
but it can rotate inside the cell to accomodate
your required cell orientation.
11. Place the unit through the hole in the
mounted faceplate so that airow
always passes through the honeycomb.
12. Thread the four (4) Knurled Thumb
Nuts onto the Threaded Bolts,
making sure a seal is created along
the backside of the Ballast Housing.
13. Plug the Power Cable into your unit
and then into the outlet. Ensure that
both the Unit Power LED and Cell
Power LED are active.

8
Maintenance/UV Lamp Indicator
Cell Disposal
Please do not throw used ARC Cells in the garbage. The special germicidal
UVC bulbs used in the unit contains a very small amount of mercury. Manage in
accordance with disposal laws.
(Visit www.lamprecycle.org for proper instructions.)
Dispose of the spent ARC Cells and UV Lamps at your local recycling center or by
local regulations. You may also send your spent ARC Cells and UV Lamps, in the
same container you received your replacement, to:
GreenTech Environmental Reclamation
6118 Kingsport Hwy 36
Johnson City, TN 37615
Your pureAir HVAC unit requires no periodic maintenance beyond the normal
replacement of the ARC Cell every year. It is recommended, for optimum
performance, that the ARC Cell be replaced annually.
The UV Lamp Operation Indicator on the face of the unit will glow when the unit is in use.
If the indicator does not glow and the unit has power, the ARC Cell needs replacing.
UV Lamp Operation IndicatorUnit Operation Indicator
Replacement Parts
Your HVAC unit requires no periodic maintenance beyond the normal replacement
of the ARC Cell on an annual basis. The cell is working when the indicator lights are
on. For optimal performance, annual maintenance is encouraged.
If you need a cell replacement, contact your distributor or contractor and reference
the cell type shown on your old cell.

9
Changing the Cell
1. Unplug the unit’s power cord from
the outlet.
2. Remove the Thumb Nuts and unit
from the duct.
3. Remove the two (2) screws holding
the cell on the rear of the Ballast
Housing.
4. Replace the Cell and UV Lamp and
fasten the new parts with the two
(2) screws into place.
5. Replace the Unit and the Thumb Nuts. 6. Plug the Power Cable back into
the outlet. Ensure that both the
Unit Power LED and Cell Power
LED are active.

10
Warranty Information
Your pureAir HVAC unit consists of two(2) separate products. The housing and power supply, which protrude
from the HVAC duct when installed, and the ARC®Cell which extends into the ductwork.
Your pureAir HVAC (Product) is warranted to be free from all defects in material and workmanship in normal
household use for a period of two (2) years from date of purchase.*
Your ARC®Cell, including the bulb, is warranted to be free from all defects in material and workmanship in
normal household use for a period of one (1) years from date of purchase.
The warranty is granted only to the original purchaser. The warranty is subject to the following provisions:
Any damages or malfunctions caused by negligence, abuse, or use not in accordance with the Product
Owner’s Manual are not covered by this warranty. Likewise, any defects or damages caused by unauthorized
service or the use of other than Genuine GreenTech Environmental Parts are not covered.
GreenTech Environmental will, at its option, repair or replace a defective Product or part(s) for the Product that
is/are covered by this warranty. As a matter of warranty policy, GreenTech Environmental will not refund the
customer’s purchase price.
OBTAINING WARRANTY SERVICE
To obtain warranty service you must return the defective product along with proof of purchase to the
GreenTech Environmental Authorized Service Center. All shipping costs submitted under this Warranty shall
be borne by purchaser. Unless this Warranty is expressly renewed or extended by GreenTech Environmental,
any repaired or replaced part of unit shall be warranted to the original purchaser only for the length of
the unexpired portion of the original warranty. For the location of the nearest GreenTech Environmental
Authorized Service Center or for other service information, please visit us online at:
www.GreenTechEnv.com
Before any product is sent for service, the customer should contact the GreenTech Environmental Service
Center to obtain a Return Merchandise Authorization (RMA) Number. This RMA Number should be clearly
written on the box before shipping. All components/parts including the remote (if applicable), manuals, and
original packaging should be included in the return if available.
FURTHER LIMITATIONS AND EXCLUSIONS ARE AS FOLLOWS
Any warranty that may be implied in connection with your purchase or use of the Product, including any
warranty of merchantability or any warranty for Fitness For A Particular Purpose is limited to the duration of this
warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above limitations
may not apply to you.
Your relief for the breach of this warranty is limited to the relief expressly provided above. In no event shall
GreenTech Environmental be liable for any consequential or incidental damages loss of prot, or medical
expenses caused by any misuse, abuse, accident, negligence, or failure to follow instructions. The company
will not be responsible for any written or oral statements made that are inconsistent with this written warranty,
or which are misleading or inconsistent with the facts as published by the company in the literature or
specications. Some states do not allow the exclusion or limitation of incidental or consequential damages, so
the above limitation or exclusion may not apply to you. This Warranty gives you specic legal rights, and you
may also have other rights which vary from state to state.
REGISTRATION
Please register your Product within 10 days of purchase by contacting GreenTech Environmental at:
www.GreenTechEnv.com/Warranty
Registering your new pureAir product entitles you to the most up-to-date GreenTech Environmental warranty
and promotion information.

11

OM REVISION: GTE-pureAir_HVAC-OwnersManual-200609
Table of contents
Other PureAire Air Cleaner manuals
Popular Air Cleaner manuals by other brands

Nilfisk-Advance
Nilfisk-Advance Mobile Odour Control Machines Nilfisk OZ 1 Specifications

Sanuvox
Sanuvox SANUVAIR S1000 CRO instruction manual

Hunter
Hunter HEPAtech 30240 owner's manual

Novita
Novita A5 Quick starter guide

Euromate
Euromate HFE Series user manual

AllerAir