2. INSTALLATION
•Before proceeding with the installation, the heating
system design must be considered and the unit
correctly sized to meet the heat loss requirements
of the room.
•Before proceeding with the installation, unpack
the carton contents and check against the
checklist below:
1. OPTIMO 500E ECO unit.
2. Instruction manual.
3. Grille.
4. Screw fixing kit (supplied separate with grille).
•This OPTIMO 500E ECO fan convector is designed
for installation in the cavity beneath kitchen
cupboards in the vacant floor space, or other
similar locations.
•For OPTIMO 500E ECO a minimum of 25mm
clear headroom is required above the top of the
OPTIMO 500E ECO when fitted.
•100mm minimum clearance is required behind the unit
when installed.
•The unit should be mounted on a clean and level floor
area under the cupboard base.
•OPTIMO 500E ECO plinth mounting (see Fig. 1) -
• The unit must be mounted on a suitable support
25mm above the floor.
• The support should be mounted on a clean and
level floor area under the cupboard base, and
securely fitted.
• The top of the support must be level with the lower
edge of the cut-out when fitted.
•Decide the position of the OPTIMO 500E ECO, mark
out and cut the plinth to the dimensions using table
on page 9.
•Position the OPTIMO 500E ECO under the cupboard
in the required location, with the front edge just behind
the line of the plinth.
•Replace the plinth and bring the OPTIMO 500E
ECO forward into the opening so the front edge
projects approximately 10mm through the plinth.
•OPTIMO 500E ECO is fitted with a transit cover to
protect the electric element and to minimise risk
of electric shock prior to the grille being fitted. The
cover must only be removed with the electrical supply
switched off immediately prior to fitting of the grille.
•Align the grille and secure it to the unit with two screws
supplied (use the shorter screws). (See Fig. 2).
•Secure the unit/grille to the plinth with two screws
supplied (use the longer screws). (See Fig. 2).
•Complete the electrical installation, switch on and test
the OPTIMO 500E ECO (see Fig. 3).
•When installed in a kitchen consideration should
be given to storage of perishable goods in the
cupboard above.
•No rear access to the unit shall be available
after installation.
3. ELECTRICAL
CONNECTION
This OPTIMO 500E ECO is supplied fitted with a 2.0 metre
1.0mm2 cord with grounded plug.
•The electrical installation must comply with local
or national wiring regulations.
•If the supply cord to OPTIMO 500E ECO is damaged,
it must be replaced by the manufacturer, its service
agent or similar qualified persons in order to avoid
a hazard.
•If the battery in the thermostat goes flat the
OPTIMO 500E ECO will not operate, therefore
if the OPTIMO 500E ECO is to be used in a holiday
home where extreme temperature can be expected
it would be recommended to connect the thermostat
to a power source via the mini USB-b socket.
3 |
OPTIMO 500E ECO
WARNING: OPTIMO 500E ECO model
must be earthed.
Do not energise the electrical supply until
the remaining stages of the installation
have been completed.
EN