OPERATING INSTRUCTIONS
FULL-AUTO DIGITAL ELECTRICAL TESTER
PDT35
Safety Information
Never use the tester if it or its test leads appear damaged.
Never apply more than 600V DC or 600V AC rms. Between any terminal
and earth ground
When using the probes, keep your fingers behind the finger guards on
the probes.
Turn off power to the circuit under test before cutting, unsoldering, or
breaking the circuit. Small amounts of current can be dangerous.
Use caution when working with voltages above 60V DC or 30V AC rms.
Such voltages pose a shock hazard.
Automatic Operation
The tester automatically turns on when you short the two test probes or place
the probes across a complete circuit.
When turned on, the tester powers up in continuity mode. If a DC or AC
voltage greater than about 4.0V is present across the inputs, the tester
switches to DC orAC voltage mode.
The tester automatically shuts down after approx. 4 minutes of inactivity.
Continuity testing
Turn off circuit power before testing.
Beeper indicates shorts lasting 1 ms or longer.
SHORT 10KOPEN
Measuring Voltage
Refer to Automatic Selection
DC Voltage (Volts DC>4.0V) AC Voltage (Volts DC>4.0V)
600V DC maximum 600V AC maximum
50Hzto400Hz
12VDC 220VAC
Specifications
Function Range Accuracy (%rdg. + digits)
V AC (50Hz~400Hz) 600V +(2.9%+8)
V DC 600V +(1.5%+2)
Continuity test: Audible threshold 0~10K, Continuity beeper 2KHz.
Overload protection: AC/DC 600V
Dimension/wt.: 215x72x36.7mm/235g
Display: Large 1999 count LCD display with function and high voltage
warning indication.
Maximum Voltage Between any Terminal and Earth Ground:
600V DC; 600V AC rms, Over-voltage Category III
Safety: Complies with EN61010-1:2001 for use in over-voltage CAT III
environments
EMC Regulations: EN50081-1, EN50082-1
Polarity:Automatic, (-) negative polarity indication.
Over-range: “1” mark indication
Low battery indication: The “BAT” is displayed when the battery voltage
drops below the operating level.
Measurement rate: 2 times per second, nominal
Continuity test: Audible threshold 0 -10K, Continuity beeper 2KHz
Input Impedance: 400K
Temperature: Operating:-10℃to +50℃(14oF to 22oF),
Storage:-30℃to +60℃
Altitude: Operating: 3,000m; Storage: 10,000m
Relative Humidity: 90%(0℃-30℃);75%(30℃-40℃); 45%(40℃-50℃)
Battery Type: AA(2); NEDA15F or IEC R6
Replacing the Batteries
If the sign “BAT” appears on the LCD, it indicates that the batteries should be
replaced. Remove screws on the back cover and open the case. Replace the
exhausted batteries with new batteries. (AA (2); NEDA 15F or IEC R6)
2xAA
Disconnect probes Do not
fromVoltage over-tightenscrews
www.pyleaudio.com

Other Pyle Multimeter manuals

Pyle PDMT05 User manual

Pyle

Pyle PDMT05 User manual

Pyle DT-9918T User manual

Pyle

Pyle DT-9918T User manual

Pyle PDMT28 User manual

Pyle

Pyle PDMT28 User manual

Pyle PDMT29 User manual

Pyle

Pyle PDMT29 User manual

Pyle PDMT25 User manual

Pyle

Pyle PDMT25 User manual

Pyle PCMT20 User manual

Pyle

Pyle PCMT20 User manual

Pyle PDMT08 User manual

Pyle

Pyle PDMT08 User manual

Pyle PDMT02 User manual

Pyle

Pyle PDMT02 User manual

Popular Multimeter manuals by other brands

Fluke 27/FM Operator's manual

Fluke

Fluke 27/FM Operator's manual

Greenlee 93-97 instruction manual

Greenlee

Greenlee 93-97 instruction manual

Southwire 13090T operating instructions

Southwire

Southwire 13090T operating instructions

Major tech MT1877IV instruction manual

Major tech

Major tech MT1877IV instruction manual

Benning MM 7-1 operating manual

Benning

Benning MM 7-1 operating manual

VOLTCRAFT vc880 operating instructions

VOLTCRAFT

VOLTCRAFT vc880 operating instructions

Meterman 37XR user manual

Meterman

Meterman 37XR user manual

Sanwa CD800a user manual

Sanwa

Sanwa CD800a user manual

zenitech RE801 instruction manual

zenitech

zenitech RE801 instruction manual

HP 8153A Service manual

HP

HP 8153A Service manual

SIGLENT TECHNOLOGIES SDM3045X Service manual

SIGLENT TECHNOLOGIES

SIGLENT TECHNOLOGIES SDM3045X Service manual

C-LOGIC 5100 instruction manual

C-LOGIC

C-LOGIC 5100 instruction manual

Amprobe AM-560 user manual

Amprobe

Amprobe AM-560 user manual

Steinberg Systems SBS-CM-1000 user manual

Steinberg Systems

Steinberg Systems SBS-CM-1000 user manual

Unit UT8803 user manual

Unit

Unit UT8803 user manual

Keysight U3606A Programmer's reference

Keysight

Keysight U3606A Programmer's reference

Chauvin Arnoux F 15 user manual

Chauvin Arnoux

Chauvin Arnoux F 15 user manual

YOKOGAWA 73201 user manual

YOKOGAWA

YOKOGAWA 73201 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.