3in1 Pocket Autoranging DMM
PDMT05
Features
3-3/4 digit 4000 count) LCD display
Built-in non-contact AC voltage detector
plus flashlight
Double Molded housing
CATIII 1000V
200mA/500V Resettable Fused current inputs and
Overload protection on all ranges
Autoranging with auto power off
www.pyleaudio.com
Safety
International Safety Symbols
This symbol, adjacent to another symbol or
terminal, indicates the user must refer to the manual
for further information.
This symbol, adjacent to a terminal, indicates that,
under normal use, hazardous voltages may be
present.
Double insulation
Safety Precautions
1. Improper use of this meter can cause damage, shock, injury or
death. Read and understand this users manual before
operating the meter.
2. Make sure any covers or battery doors are properly closed and
secured.
3. Always disconnect the test leads from any voltage source
before replacing the battery or fuses.
4. Do not exceed the maximum rated input limits.
Input Limits
Function Maximum Input
V DC or V AC 600V DC/AC
µA AC/DC 200mA/500V fast acting
Resettable Fuse
Resistance, Diode &
Continuity Test
600V DC/AC
5. Use great care when making measurements if the voltages are
greater than 25VAC rms or 35VDC. These voltages are
considered a shock hazard.
6. Always discharge capacitors and remove power from the
device under test before performing Diode, Resistance or
Continuity tests.
7. Remove the battery from the meter if the meter is to be
stored for long periods.
Meter Description
1. Non-contact AC voltage detector probe tip
2. Non-contact AC voltage indicator light
3. 3 3/4 Digit (4000 count)
4. MODE button
5. Function switch
6. Flashlight
7. Flashlight button
8. Hz/%Duty button
9. Battery Cover
10. Test leads
Specifications
Electrical Specifications
Function Range Accuracy
400mV, (0.5% rdg + 3d)
DC Voltage
4.000V,40.00V, 400.0V,
600V
(1.2% rdg + 3d)
4.000V, 40.00V (1.0% rdg + 8d)
AC Voltage
50-60Hz 400.0V, 600V (2.3% rdg + 10d)
400.0µA, 4000µA
DC Current
40.00mA, 200.0mA
(2.0% rdg + 8d)
400.0µA, 4000µA
AC Current
50-60Hz 40.00mA, 200.0mA
(2.5% rdg + 10d)
400.0(0.8% rdg + 5d)
4.000k, 40.00k,
400.0k
(1.2% rdg + 5d)
4.000M(5.0% rdg + 5d)
Resistance
40.00M(10.0% rdg + 5d)
4.000nF (5.0% rdg + 0.6nF)
40.00nF (5.0% rdg + 30d)
400.0nF (3.0% rdg + 15d)
Capacitance
4.000µF, 40.00µF,
200.0µF
(5.0% rdg + 25d)
Frequency 9.999Hz, 99.999Hz,
999.9Hz, 9.999kHz, (2.0% rdg + 5d)
Duty Cycle 0.5-99% (2.0% rdg + 5d)
Max input voltage 600V AC/DC
Diode Test Test current 1mA max., open circuit voltage
of 1.5V typical
Continuity Check Audible signal if the resistance is <100
Display 4000 count 3 -3/4 digit LCD
Over range indication LCD displays “OL”
Polarity Minus (-) sign for negative polarity.
Low Battery Indication “BAT” symbol indicates low battery
condition.
Input Impedance >7.5M(VDC & VAC)
AC Response Average responding
ACV Bandwidth 50Hz to 60Hz
Auto Power Off 15 minutes (approximately)
Fuse mA, µA ranges; 0.4A/600V fast acting
Resettable Fuse
Batteries Two 1.5V AAA
Operating Temperature 32oF to 104oF (0oC to 40oC)
Storage Temperature 14oF to 122oF (-10oC to 50oC)
Weight 145g
Size 104x55x32.5mm
Standard IEC61010-1 CAT III 1000V Pollution
degree II, CE Approved
Operation
AC/DC VOLTAGE MEASUREMENTS
CAUTION: Do not measure AC/ DC voltages if a motor
on the circuit is being switched ON or OFF. Large
voltage surges may occur that can damage the meter.
1. Set the function switch to the green V position.
2. Press the MODE button to indicate “DC” or “AC” on the
display.
3. Touch the black test probe tip to the negative side of
the circuit.
Touch the red test probe tip to the positive side of the
circuit.
4. Read the voltage in the display
DC/AC CURRENT MEASUREMENTS
1. Set the function switch to the µA/mA position.
2. For current measurements up to 4000µA DC/AC, set the
function switch to the mA position
3. Press the MODE button to indicate “DC” / “AC” on the
display.
4. Remove power from the circuit under test, then open up
the circuit at the point where you wish to measure
current.
5. Touch the black test probe tip to the negative side of
the circuit.
Touch the red test probe tip to the positive side of the
circuit.
6. Apply power to the circuit.
7. Read the current in the display
NOTE: 0.2A/500V fast acting Resettable Fuse
current inputs and Overload protection on mA, µA
ranges. No replacement required.
RESISTANCE MEASUREMENT
WARNING: To avoid electric shock, disconnect power to
the unit under test and discharge all capacitors before
taking any resistance measurements. Remove the
batteries and unplug the line cords.
1. Set the function switch to the Ωposition.
2. Press the MODE button to indicate on the display.
3. Touch the test probe tips across the circuit or part under
test. It is best to disconnect one side of the part under
test so the rest of the circuit will not interfere with the
resistance reading.
4. Read the resistance in the display
CONTINUITY CHECK
WARNING: To avoid electric shock, never measure
continuity on circuits or wires that have voltage on them.
1. Set the function switch to the Ωposition.
2. Press the MODE button to indicate on the display
3. Touch the test probe tips to the circuit or wire you wish to
check.
4. If the resistance is less than approximately 150, the
audible signal will sound. If the circuit is open, the
display will indicate “OL”.
DIODE TEST
1. Set the function switch to the Ωposition.
2. Press the MODE button to indicate   on the
display.
3. Touch the test probes to the diode under test. Forward
voltage will typically indicate 0.400 to 0.700V. Reverse
voltage will indicate “OL”. Shorted devices will indicate
near 0V and an open device will indicate “OL” in both
polarities
Capacitance Measurement
WARNING: To avoid electric shock, disconnect power to the unit
under test and discharge all capacitors before taking any
capacitance measurements. Remove the batteries and unplug
the line cords. Never measure continuity on circuits or wires that
have voltage on them.
1. Set the function switch to the “ •))) ” position.
2. Press the SELECT button until “nF” appears in the display.
3. Press the RELATIVE button to zero the display
4. Connect the test leads to the capacitor to be measured.
5. Read the value on the display.
Frequency/Duty Cycle Measurement
1. Set the function switch to the “HZ/DUTY” position.
2. Press the Hz/DUTY button once to display Duty Cycle %. Pressing
the button again will toggle the display to frequency (Hz).
3. Touch the test probe tips to the circuit under test. Be sure to
observe the correct polarity (red lead to positive, black lead to
negative).
4. Read the value on the display.
Non-Contact AC Voltage Measurements
1. Touch the probe tip to the hot conductor or insert into the
hot side of the electrical outlet.
2. If AC voltage is present, the detector light will illuminate.
NOTE: The conductors in electrical cord sets are often
twisted. For best results, rub the probe tip along a
length of the cord to assure placing the tip in close
proximity to the live conductor.
NOTE: The detector is designed with high sensitivity.
Static electricity or other sources of energy may
randomly trip the sensor. This is normal operation
Flashlight
Press and hold the top button to turn the flashlight on.
Release the button to turn the flashlight off.
AUTO POWER OFF
The auto off feature will turn the meter off after 15 minutes.
REPLACING THE BATTERY
1. Remove the bottom cover and secure the screw.
2. Replace old battery with fresh Two 1.5V AAA type battery.
3. Replace the bottom cover and secure the screw.
WARNING: Risk of Electrocution. Before use, always
test the Voltage Detector on a known live circuit to
verify proper operation

Other Pyle Multimeter manuals

Pyle PDMT29 User manual

Pyle

Pyle PDMT29 User manual

Pyle DT-9918T User manual

Pyle

Pyle DT-9918T User manual

Pyle PDMT28 User manual

Pyle

Pyle PDMT28 User manual

Pyle PDMT02 User manual

Pyle

Pyle PDMT02 User manual

Pyle PDMT08 User manual

Pyle

Pyle PDMT08 User manual

Pyle PDMT25 User manual

Pyle

Pyle PDMT25 User manual

Pyle PCMT20 User manual

Pyle

Pyle PCMT20 User manual

Pyle PDT35 User manual

Pyle

Pyle PDT35 User manual

Popular Multimeter manuals by other brands

Renogy RNG-TOOL-MM manual

Renogy

Renogy RNG-TOOL-MM manual

Ethos 5050 instruction manual

Ethos

Ethos 5050 instruction manual

YATO YT-73091 instruction manual

YATO

YATO YT-73091 instruction manual

Fluke 116 user manual

Fluke

Fluke 116 user manual

Hameg HM 8040-2 manual

Hameg

Hameg HM 8040-2 manual

PDi DM68 instruction manual

PDi

PDi DM68 instruction manual

multicomp pro MP730988 user manual

multicomp pro

multicomp pro MP730988 user manual

Mastech MS8321B instruction manual

Mastech

Mastech MS8321B instruction manual

Velleman AVM460 user manual

Velleman

Velleman AVM460 user manual

PeakTech 1075 Operation manual

PeakTech

PeakTech 1075 Operation manual

Forney DT-831B+ instruction manual

Forney

Forney DT-831B+ instruction manual

Allegro Network Multimeter 1300 installation guide

Allegro

Allegro Network Multimeter 1300 installation guide

Wetekom 31 32 54 instruction manual

Wetekom

Wetekom 31 32 54 instruction manual

HoldPeak 870N Operation manual

HoldPeak

HoldPeak 870N Operation manual

Amprobe CDM-1 operating instructions

Amprobe

Amprobe CDM-1 operating instructions

GB GDT-311 operating instructions

GB

GB GDT-311 operating instructions

Omega RH511 quick start guide

Omega

Omega RH511 quick start guide

optofidelity OF-10030-00 user manual

optofidelity

optofidelity OF-10030-00 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.