Function and Operation
ULTRAVIOLET DETECTION
Connect the power and turn on the unit, select to ultraviolet switch . Put the banknote on the
table and cover the inductor, the ultraviolet tube will be on automatically, it will be o after you
take out the banknote from the table for twenty seconds .
• Under ultraviolet lamp , something has uorescent reaction when they are with
uorescent ink (uorescent powder) Or ber. According to this principal , the ultraviolet
lamp can detect counterfeit banknote/ stock/ note/ credit card/traveling check/
uorescent stamps/ uorescent mark and other legal document etc.
• Furthermore, it can check and sort out all kinds of man-made ber and its promiscuous
degree. Because the ultraviolet reaction in the front and back of banknote is dierent, the
banknote must be turned back to detect once again to avoid the suspect one is passed.
WHITE LIGHT PERSPECTIVE DETECTION
Turn the white light switch on,put the banknote/ stock/ check on the perspective window and
cover the Inductor (refer to Fig.). The white light tube will be on automatically. It will be o after
you table out the banknote form the table for twenty seconds.
• It can check the denition of water mark / wire/ pattern/ gure and detect out whether
there are painted out mark on the banknote.
MAGNETIC INK DETECTION
Put the banknote on the magnetic inductor, the magnetic ink detection is standby automatically.
It will turn o when taking out the banknote. Magnetic detection is only suitable for detecting
the banknote with magnetic ink.(Use your hand to put the magnetic ink of banknote to touch
the magnetic head and left right rub, if the banknote has magnetic ink reaction, the magnetic
indicator will ash and send out an alarm, that means the banknote is true, not counterfeit)
Maintenance
• Please avoid using the unit under a strong sunlight , since it will aect the denition of
ultraviolet reaction.
• Don't put any magnetic material near the unit when using the magnetic ink detection to
avoid producing jamming.
• Use alcohol to clean the magnetic head regularly and clean the dust on the ultraviolet
tube with towel to avoid aecting the detection result.
• The power must be cut o when nishing detection.
• Please disconnect the power cord under cleaning or maintenance or don't use the unit
for long time .