Pylon Technologies PowerCube-X1 User manual

1/ 23
17PIXV1101
Lithium-Ion Phosphate Battery
PowerCube-X1 Product Manual
Information Version: 3.0
Pylon Technologies Co., Ltd.
No. 73, Lane 887, ZuChongzhi Road, Zhangjiang Hi-Tech Park
Pudong, Shanghai 201203, China Zip Code: 201203
Tel: 021-51317697
Fax: 021-51317698
Email: service@pylontech.com.cn
Website: http://www.pylontech.com.cn

2/ 23
17PIXV1101
This manual introduces PowerCube-X1 from Pylontech. PowerCube-X1 is a high voltage
Lithium-Ion Phosphate Battery storage system. Please read this manual before you install the
battery and follow the instruction carefully during the installation process. Any confusion, please
contact Pylontech immediately for advice and clarification.
Contents
1. SAFE HANDLING OF LITHIUM BATTERIES GUIDE................................................................................3
Before Connecting .........................................................................................................................3
In Using..............................................................................................................................................3
2. INTRODUCTION..................................................................................................................................5
2.1 features.......................................................................................................................................5
2.2 Specifications ............................................................................................................................6
2.2.1 Battery System........................................................................................................................6
2.2.2 Battery Module.......................................................................................................................8
Battery Module Front Interface ..........................................................................................9
2.2.3 Control Module (internal power supply)..........................................................................10
Definition of RJ45 Port Pin ..................................................................................................11
LED Indicators Instructions .................................................................................................11
2.2.4 3rd Level Control Module (MBMS)...................................................................................13
Definition of RJ45 Port Pin ..................................................................................................14
LED Indicators Instructions .................................................................................................14
3. INSTALLATION..................................................................................................................................16
3.1 Tools...........................................................................................................................................16
3.2 Safety Gear..............................................................................................................................16
3.3 Package Items ........................................................................................................................16
Accessories ..........................................................................................................................16
Unpacking and check the Packing List: .........................................................................16
3.4 Installation Location ...............................................................................................................18
Installation ............................................................................................................................19
5. TROUBLE SHOOTING STEPS .................................................................................................................21
6. EMERGENCY SITUATIONS ...................................................................................................................22

3/ 23
17PIXV1101
1. Safe handling of lithium batteries Guide
Warning: This product is a high voltage DC system, operated by authorized person
only.
Warning
Before Connecting
1) After unpacking, please check product and packing list first, if product is damaged or
lack of parts, please contact with the local retailer;
2) Before installation, be sure to cut off the grid power and make sure the battery is in the
turned-off mode;
3) Wiring must be correct, do not mistake the positive and negative cables, and ensure no
short circuit with the external device;
4) It is prohibited to connect the battery and AC power directly;
5) Battery system must be well grounded and the resistance must be less than 1Ω;
6) Please ensured the electrical parameters of battery system are compatible to related
equipment;
7) Keep the battery away from water and fire.
In Using
1) If the battery system needs to be moved or repaired, the power must be cut off and the
battery is completely shutdown;
2) It is prohibited to connect the battery with different type of battery.
3) It is prohibited to put the batteries working with faulty or incompatible inverter;
4) It is prohibited to disassemble the battery (QC tab removed or damaged);
5) In case of fire, only dry powder fire extinguisher can be used, liquid fire extinguishers are
prohibited;
6) Please do not open, repair or disassemble the battery except staffs from Pylontech or
authorized by Pylontech. We do not undertake any consequences or related
responsibility which because of violation of safety operation or violating of design,
production and equipment safety standards.

1)
2)
3)
4)
5)
6)
7)
R
e
Please re
a
If the bat
t
the SOC s
Battery n
e
Do not ex
All the ba
t
Please co
The warra
e
minded
a
d the user
t
ery is store
d
hould be n
o
e
eds to be
r
pose cabl
e
t
tery termin
ntact the s
u
nty claims
a
manual ca
d
for long t
o
less than
8
r
echarged
w
e
outside;
als must b
e
u
pplier with
a
re exclud
e
4/ 23
refully (in t
h
ime , it is r
e
8
0%;
w
ithin 12 h
o
e
disconne
c
in 24 hours
i
e
d for direc
t
h
e accesso
r
e
quired to
c
o
urs, after f
u
c
ted for mai
i
f there is s
o
t
or indirect
r
ies);
c
harge the
m
u
lly dischar
g
ntenance;
o
mething a
b
damage
d
m
every six
g
ed;
b
normal.
d
ue to item
s
17PIXV11
0
months, a
n
s
above.
0
1
n
d

5/ 23
17PIXV1101
2. Introduction
PowerCube-X1 is a high voltage battery storage system based on lithium iron phosphate battery,
is one of new energy storage products developed and produced by Pylontech, it can be used to
support reliable power for various types of equipments and systems. PowerCube-X1 is especially
suitable for application scene of high power, limited installation space, restricted load-bearing
and long cycle life.
PowerCube-X1 has 2 levels BMS (battery management system), which can manage and monitor
cells information including voltage, current and temperature. What’s more, BMS can balance
cells charging and discharging to extend cycle life. Multiple batteries can connected in parallel
to expand capacity and power in parallel for larger capacity and longer power supporting
duration requirements.
2.1 features
The whole module is non-toxic, non-polluting and environmentally friendly;
Cathode material is made from LiFePO4 with safety performance and long cycle life;
Battery management system (BMS)has protection functions including over-discharge,
over-charge, over-current and high/low temperature;
The system can automatically manage charge and discharge state and balance current
and voltage of each cell;
Flexible configuration, multiple battery modules can be in serial for expanding voltage and
capacity.
Adopted self-cooling mode rapidly reduced system entire noise;
The module has less self-discharged, up to 6 months without charging ion shelf; no memory
effect, excellent performance of shallow charge and discharge;
Working temperature range is from 0℃to 50℃, with excellent discharge performance and
cycle life;
Small size and light weight, standard of 19-inch embedded designed module is comfortable
for installation and maintenance;
Caution: PowerCube-X1 without soft-start circuit. So must choose the Inverter, which has soft-start
function, otherwise has the risk of equipment breakdown.

2.2 S
p
2.2.1
B
p
ecification
B
attery Sys
t
s
t
em
6/ 23
17PIXV11
0
0
1

7/ 23
17PIXV1101
No. Item PowerCube-X1
(336V50AH)
1 Cell Technology Li-ion (LFP)
2 Battery System Capacity (kWh) 16.8
3 Battery System Voltage (Vdc) 336
4 Battery System Capacity (Ah) 50
5 Battery Controller Name SC0500-100
6 Battery Module Name H48050
7 Battery Module Quantity (pcs) 7
8 Battery Module Capacity (kWh) 2.40
9 Battery Module Voltage (Vdc) 48
10 Battery Module Capacity (Ah) 50
11 Battery Module Cell Quantity (pcs) 15
12 Battery System Charge Voltage (Vdc) 378
13 Battery System Charge Current (Standard) 10
14 Battery System Charge Current (Normal) 25
15 Battery System Charge Current (Max.) 50
16 Battery System Discharge lower-Voltage (Vdc) 315
17 Battery System Discharge Current (Standard) 10
18 Battery System Discharge Current (Normal) 25
19 Battery System Discharge Current (Max.) 50
20 Efficiency 96%
21 Depth of Discharge 80% (10~90%)
22 Dimension (W*D*H, mm) 600*505*1300
23 Communication RS485 / CAN
24 Protection Class IP20
25 Weight (kg) 250
26 Operation Life (Years) 10
27 Operation Cycle Life 3500
28 Operation Temperature (℃) 0~50
29 Storage Temperature (℃) -20~60
30 Product Certificate TÜV, CE
31 Transfer Certificate UN38.3
32
Other:
1)Battery Controller Dimensions (W*D*H)
2)Battery Module Dimensions (W*D*H)
442*390*132
442*390*100
Remark: The parameter will be changed when the battery modules in different series (3~7 pcs
battery modules).

2.2.2
B
B
attery Mo
d
No.
1 Cel
2 Bat
3 Bat
4 Bat
5 Bat
6 Bat
7 Bat
8 Bat
9 Bat
10 Bat
12 Bat
13 Bat
14 Bat
15 Bat
16 Bat
17 Bat
18 Bat
19 Effi
c
20 De
p
21 Di
m
22 Co
m
23 Pro
t
24 We
25 Op
e
26 Op
e
27 Op
e
28 Sto
r
29 Pro
d
30 Tra
n
d
ule
l Technolo
g
tery Modul
e
tery Modul
e
tery Modul
e
tery Modul
e
tery Cell C
a
tery Cell V
o
tery Cell C
a
tery Modul
e
tery Modul
e
tery System
tery Modul
e
tery Modul
e
tery Modul
e
tery System
tery Modul
e
tery Modul
e
c
iency
p
th of Disc
h
m
ension (W*
m
municati
o
t
ection Cla
s
ight
e
ration Life
e
ration Cy
c
e
ration Te
m
r
age Temp
e
d
uct Certifi
c
n
sfer Certifi
c
Product
T
g
y
e
Capacity
e
Voltage (
V
e
Capacity
e
Quantity
(
a
pacity (W
h
o
ltage (Vdc
a
pacity (A
H
e
Cell Qua
n
e
Charge V
Charge C
u
e
Charge
C
e
Charge
C
e
Discharg
e
Discharge
e
Charge
C
e
Charge
C
h
arge
D*H, mm)
o
n
s
s
c
le Life
m
perature
e
rature
c
ate
c
ate
8/ 23
T
ype
(kWh)
V
dc)
(AH)
(
pcs)
h
)
)
H
)
n
tity in Serie
s
oltage (Vd
c
u
rrent (Stan
C
urrent (Nor
m
C
urrent (Ma
x
e
lowe
r
-Volt
Current (St
a
C
urrent (Nor
m
C
urrent (Ma
x
s
(pcs)
c
)
dard)
m
al)
x
.)
age (Vdc)
a
ndard)
m
al)
x
.)
H48050
A
Li-ion (
2.
4
48
50
30
80
3.
2
25
15
54
10
25
50
45
10
25
50
96
%
80% (10
~
442*39
0
RS485 /
IP2
0
24
10+Y
e
400
0~5
0
-20~6
0
TÜV (IEC
6
UN3
8
A
-15S
LFP)
4
2
%
~
90%)
0
*100
CAN
0
e
ars
0
0
℃
0℃
6
2619)
8
.3
17PIXV11
0
0
1

9/ 23
17PIXV1101
Battery Module Front Interface
PowerTerminal+/-
To connect battery series power cables.
Status
Status light: to show the battery module’s status (RUN●, Alarm●and Protection●).
RS232Terminal
Console Communication Terminal: (RJ45 port) follow RS232 protocol, for manufacturer or
professional engineer to debug or service.
LinkPort0,1
Link Port 0, 1 Communication Terminal: (RJ45 port) follow RS485 protocol, for communication
between multiple serial battery modules and control module.
PowerTerminals
Power cable terminals: there are two pair of terminals with same
function, one connect to equipment, the other one paralleling to other
battery module for capacity expanding. For each single module, each
terminal can achieve charging and discharging function.
For power cables uses water-proofed AMPHENOL connectors. It must
keep pressing this Lock Button during pulling out the power plug.

10 / 23
17PIXV1101
2.2.3 Control Module (internal power supply)
Control Module has two types: internal and external power supply.
Control Module (SC0500A-100S) Front Interface
PowerTerminal+/-
To connect battery power cables in series.
PowerSwitch
Switch the battery system’s (control module and high voltage DC power) ON/OFF.
ExternalPowerTerminal+/-
Connect battery system with Inverter.
DryContactTerminal
Dry Contact Terminal: provided 2 input and 4 output dry contact signal.
Reset
Reset Button: Long press this button to restart the battery system.
ADD
ADD: 6 bit dial switches to manually distribute the communication address of the battery
system. Nether position is OFF, means “0”. Upper position is ON, means “1”. 1st bit to 5th bit is for
address, and the 6th bit dial switch support a 120Ωresistance.
PowerOutputSwitch
To control the high voltage DC power ON/OFF during the System Switch ON. Normally it turns
in ON position, needn’t turn it OFF.
CAN/RS485
CAN Communication Terminal: (RJ45 port) follow CAN protocol, for communication between
battery system and Inverter.

RS
4
be
t
RS232
Co
pr
o
Link P
o
Lin
k
be
t
Defini
t
No.
1
2
3
4
5
6
7
8
12VD
C
Po
w
Status
St
a
LED St
a
B
a
c
a
LED In
d
Bat
t
Sta
t
Shut
D
Sle
4
85 Comm
u
t
ween batt
e
Terminal
nsole Com
o
fessional e
n
o
rt1
k
Port 1 Co
m
t
ween mult
i
t
ion of RJ45
C
A
--
-
G
N
--
-
CA
N
CA
--
-
--
-
--
-
C
Output Te
r
w
er supply
f
a
tus light: to
a
tus Indica
t
a
ttery capa
c
a
pacity.
d
icators Ins
t
ery
t
ues
Prot
e
Al
a
N
o
D
own
ep N
o
u
nication Te
e
ry system
a
municatio
n
n
gineer to
d
m
municatio
i
ple serial b
a
Port Pin
A
N
-
N
D
-
N
H
NL
-
-
-
r
minal
f
or 3rd level
c
show the
b
t
ors
c
ity indicat
o
tructions
e
ction /
a
rm /
o
rmal
R
U
●
O
o
rmal Fl
a
1
rminal: (RJ
4
a
nd Inverte
r
n
Terminal:
d
ebug or s
e
n Terminal:
a
tte
r
y mod
u
RS485
---
---
---
---
---
GND
RS485A
RS485B
c
ontrol mo
d
b
attery mo
d
o
r (No.8 Fig
U
N ALM
●
●
O
ff Off
a
sh
1
Off
11 / 23
4
5 port) foll
o
r
.
(RJ45 port
)
e
rvice.
(RJ45 port)
u
les and c
o
RS23
2
--
-
--
-
T
X
--
-
--
-
R
X
--
-
G
N
d
ule, with 1
d
ule’s status
ure 2-1): 4
g
PRC
●
●
Off O
f
Off O
f
o
w RS485 p
r
)
follow RS
2
follow CA
N
o
ntrol mod
u
2
Pin
-
-
X
-
-
X
-
N
D
2
VDC cabl
e
(RUN
●
, Ala
g
reen lamp
s
Capacity
S
●
●
●
f
Off
O
f
f
Off
O
f
r
otocol, for
c
2
32 protoc
o
N
protocol,
f
u
le.
e
:
rm
●
and Pr
o
s
, each ligh
S
OC
●
●
f
f
Off
f
f
Off
I
c
ommunic
a
o
l, for ma
n
f
or commu
n
o
tection
●
).
t represent
Descrip
t
All o
f
ndicates Sle
e
to save th
e
17PIXV11
0
a
tion
n
ufacturer
o
n
ication
25%
t
ions
f
f
e
p Mode,
power.
0
1
o
r

12 / 23
17PIXV1101
Standby
Normal Flash
1 Off Off Off
Off
Off
Off
Indicates save power
mode.
Alarm Off Light
Off Off
Off
Off
Off
Indicates the battery is
low.
Standby Normal
Flash
1 Off Off Off
Off
Off
Off
Indicates Standby
Charge
Normal Light Off Off The highest capacity
indicator LED flashes
(flash 2), others lighting
The highest capacity
indicator LED flashes
(flash 2), others lighting
Alarm Off Light
Off
Protection Off Off Light
Off
Off
Off
Off
Stop charging, PRC
lighting
Discharge
Normal Flash
3 Off Off
Indicate based on
capacity
Indicate based on
capacity
Alarm Off Light
Off
Protection Off Off Light
Stop discharging, PRC
lighting
Abnormal Protection Off Off Light
Off
Off
Off
Off
Stop
charging/discharging,
PRC lighting
Note: The flashing instructions, flash 1 –0.25s light / off 3.75 seconds; flash 2 - 0.5s light / 0.5s off;
flash 3 - 0.5s light / 1.5s off.
External power supply Control Module
External power supply Control Module has an Australia standard AC
Power input socket and power switch. It is applied with UPS system.
For external power supply control module there is additional AC power cable:
Australia Standard
Or
Europe Standard

2.2.4
MBMS
batter
y
If the
p
adapt
provi
d
Seri
a
Numb
1
2
3
4
5
6
7
8
9
10
Dry C
o
Dr
y
Reset
Re
s
ADD
AD
sys
t
Swi
3rd Level
C
is the cont
r
y
piles in p
a
p
ower supp
or (220Vac
d
ed.
a
l
e
r
Opera
t
Comm
Outpu
t
Input
d
System
Size
Protec
t
Weigh
t
Workin
g
Storag
e
o
ntact Ter
m
y
Contact T
e
s
et Button:
L
D: 6 bit di
a
t
ems. Neth
e
tch can be
C
ontrol Mo
d
r
oller for m
u
a
rallel con
n
ly is 220Va
c
to 12Vdc)
w
Product
M
t
ing voltag
e
unication i
n
t
dry conta
c
d
ry contact
Consumpt
i
t
ion degre
e
t
(kg)
g
tempera
t
e
temperat
m
inal
e
rminal: pr
o
L
ong press t
a
l switches
e
r position i
s
set up wit
h
1
ON
d
ule (MBM
S
u
ltiple
n
ection.
c
, an
w
ill be
M
odel
e
range
n
terface
c
t interface
interface
i
on
e
t
ure
ure
o
vided 2 w
a
his button t
to manual
s
OFF, mea
n
h
“100001”.
C
o
2 3
OFF OF
13 / 23
S
)
4
4
OUT1A
/
a
y input an
d
o restart th
e
ly distribut
e
n
s “0”. Upp
e
o
de Bits
4
F
OFF
MBMS100
0
12 Vdc
CAN/RS48
5
4 groups
2 groups
2W
4
2*190*44
m
IP20
5
-20~60℃
-40~80℃
/
OUT1B...O
U
d
4 ways ou
e
battery s
y
e
the com
m
e
r position
i
5 6
OFF
ON
0
5
m
m
U
T4A/OUT4
B
tput dry co
y
stem.
m
unication
i
s ON, mea
n
B
, IN1A/IN1
B
ntact signa
address o
f
n
s “1”. The
17PIXV11
0
B
/IN2A/IN2
B
l.
Res
e
AD
D
f
the batte
MBMS’s A
D
0
1
B
et
D
ry
D
D

CAN
/
C
A
ba
t
RS
4
be
t
RS232
Co
pr
o
Link P
o
Lin
k
be
t
Defini
t
No.
1
2
3
4
5
6
7
8
Status
St
a
LED St
a
B
a
c
a
LED In
d
Bat
t
Sta
t
Shut
D
Sle
/
RS485
A
N Commu
n
t
tery syste
m
4
85 Comm
u
t
ween batt
e
Terminal
nsole Com
o
fessional e
n
o
rt
k
Port Com
m
t
ween mult
i
t
ion of RJ45
C
A
--
-
G
N
--
-
CA
N
CA
--
-
--
-
--
-
a
tus light: to
a
tus Indica
t
a
ttery cap
a
a
pacity.
d
icators Ins
t
ery
t
ues
Prot
e
Al
a
N
o
D
own
ep N
o
A
n
ication Ter
m
m
and PCS.
u
nication Te
e
ry system
a
municatio
n
n
gineer to
d
m
unication
i
ple serial b
a
Port Pin
A
N
-
N
D
-
N
H
NL
-
-
-
show the
b
t
ors
a
city indic
a
tructions
e
ction /
a
rm /
o
rmal
R
U
●
O
o
rmal Fl
a
A
larm
m
inal: (RJ4
5
rminal: (RJ
4
a
nd PCS.
n
Terminal:
d
ebug or s
e
Terminal: (
R
a
tte
r
y mod
u
RS485
---
---
---
---
---
GND
RS485A
RS485B
b
attery mo
d
a
tor (No.8
U
N ALM
●
●
O
ff Off
a
sh
1
Light
14 / 23
5
port) follo
w
4
5 port) foll
o
(RJ45 port
)
e
rvice.
R
J45 port) f
o
u
les and c
o
RS23
2
--
-
--
-
T
X
--
-
--
-
R
X
--
-
G
N
d
ule’s status
Figure 2-1)
PRC
●
●
Off O
f
O
f
O
f
w
CAN pro
t
o
w RS485 p
r
)
follow RS
2
o
llow RS485
o
ntrol mod
u
2
Pin
-
-
X
-
-
X
-
N
D
(RUN
●
, Ala
: 4 green
Capacity
S
●
●
●
f
f
Off
O
f
f
f
Off
O
f
f
f
Off
O
f
t
ocol, for c
o
r
otocol, for
c
2
32 protoc
o
protocol, f
o
u
le.
Link Port Pi
n
---
GND
---
CANH
CANL
---
---
---
rm
●
and Pr
o
lamps, ea
S
OC
●
●
f
f
Off
f
f
Off
f
f
Off
o
mmunicati
c
ommunic
a
o
l, for ma
n
o
r commu
n
n
o
tection
●
).
ch light r
e
Descrip
t
All o
f
17PIXV11
0
RS485; C
A
on betwee
a
tion
RS23
n
ufacturer
o
LinkPo
ication
e
present 2
5
t
ions
f
f
0
1
A
N
n
2
o
r
rt
5
%

15 / 23
17PIXV1101
Standby Normal
Flash
1 Off Off Off
Off
Off
Off
Indicates Standby
Charge
Normal Light Off Off The highest capacity
indicator LED flashes
(flash 2), others lighting
Alarm Off Light
Off
Protection Off Off Light
Off
Off
Off
Off
Stop charging, ALM
lighting
Discharge
Normal Flash
3 Off Off Indicate based on
capacity
Protection Off Light
Light
Off
Off
Off
Off
Stop discharging, ALM
lighting
Note: The flashing instructions, flash 1 - light 0.25s / off 3.75 seconds; flash 2 - 0.5s light / 0.5s off;
flash 3 - 0.5s light / 1.5s off.
PowerOutputSwitch
Turn ON/OFF the MBMS power, and ON/OFF the power output of external power of control
modules.
12VDCInput
Take 12VDC power from outside (from control module or
AC/DC adaptor).

16 / 23
17PIXV1101
3. Installation
3.1 Tools
The following tools are required to install the battery pack
WireCutter CrimpingModularPlier ScrewDriverSet
NOTE
Use properly insulated tools to prevent accidental electric shock or short circuits.
If insulated tools are not available, cover the entire exposed metal surfaces of the available tools,
except their tips, with electrical tape.
3.2 Safety Gear
It is recommended to wear the following safety gear when dealing with the battery pack
Insulatedgloves Safetygoggles Safetyshoes
3.3 Package Items
Accessories
The type and quantity of the accessories are subject to the battery packing list.
Unpacking and check the Packing List:
Power Cable + (Connection for
Battery Series + to Control
Module +)
Orange/0.16m/4AWG/2 Orange
Surlok Terminal pcs 1

17 / 23
17PIXV1101
Power Cable - (Connection for
Battery Series - to Control
Module -)
Black/1.5m/4AWG/2 Black Surlok
Terminal pcs 1
Power Cable (Battery Module
Serial Connection)
Orange/0.18m/4AWG/1 Orange &
1 Black Surlok Terminal pcs 7
Battery Cascade
Communication Cable (0.18m)
Black/0.18m/8 Core Super 5th
Class Twisted-pair Wire/RJ45 pcs 8
External Battery CAN
Communication Cable (direct)
Black/3.5m/Super 5th Class
Twisted-pair Wire/2 RJ45 terminal pcs 1
External Power Cable + Orange/2m/4AWG/SURLOK
Terminal/25-8 Terminal pcs 1
External Power Cable - Black/2m/4AWG/SURLOK
Terminal/25-8 Terminal pcs 1

18 / 23
17PIXV1101
For external power supply control module there is additional AC power cable:
AC Power Cable (Australia
Standard)
Black/2.5m/3*0.75mm2/Australia
Standard pcs 1
NOTE
Power cable uses water-proofed AMPHENOL connectors. It must keep
pressing this Lock Button during pulling out the power plug.
Grounding:
The PowerCube-X1 modules are grounding based on metal direct touch
between the module’s surface and rack’s surface. So it needn’t grounding
cables at all. If uses normal rack, it can remove the paint at the
corresponding place. Or install a grounding cable to the grounding point of
the modules.
CAUTION
The rack/cabinet grounding goes through the connection with Metal base support or grounding
cable through the stud screw at the bottom of the rack/cabinet. The connection is necessary.
3.4 Installation Location
Make sure that the installation location meets the following conditions:
The area is completely water proof.
The floor is flat and level.
There are no flammable or explosive materials.

T
h
T
h
T
h
CAUTI
O
If the
a
prote
c
Frequ
e
batte
r
Insta
l
A. Pu
①C
o
c
a
②Pu
③Dr
i
④C
o
The c
a
h
e ambient
h
e tempera
h
ere is mini
m
O
N
a
mbient te
m
c
t itself. The
e
nt exposu
r
r
y pack.
l
lation
t battery m
o
o
nnect the
a
ble from In
v
t the contr
o
i
ve the scr
e
o
nnect the
a
bles’ instal
l
temperatu
r
ture and h
u
m
al dust an
d
m
perature i
optimal te
m
r
e to harsh
t
o
dules into
External C
o
v
erte
r
;
o
l module
a
e
ws, to fast
e
cables bet
w
l
ation sequ
e
r
e is within
t
u
midity is m
a
d
dirt in the
s outside th
m
perature
r
t
emperatur
e
cabinet an
o
mmunicati
a
nd the bat
t
e
n each m
o
w
een batt
e
e
nce is as f
o
19 / 23
t
he range f
r
a
intained
a
area.
e operatin
g
r
ange for t
h
e
s may det
e
d connect
t
on Cable,
E
t
ery modul
e
o
dule on th
e
e
ry modules
o
llowed di
a
r
om 0°C to
5
a
t a consta
n
g
range, th
e
h
e battery
p
e
riorate th
e
t
he cables:
E
xternal Po
w
e
s into the
c
e
rack;
and the c
o
a
gram:
5
0°C.
n
t level.
e
battery p
a
p
ack to op
e
e
performa
n
w
er Cable
+
c
abinet;
o
ntrol mod
u
a
ck stops o
p
e
rate is 0°C
t
n
ce and life
+
and - a
n
u
le;
17PIXV11
0
p
erating to
t
o 50°C.
of the
n
d AC pow
e
0
1
e
r

20 / 23
17PIXV1101
B. System turn On
Double check all the power cables and communication cables. Make sure the voltage of the
Inverter is same level with the battery system.
(1) Switch battery system switch on.
All the control modules and the battery modules’ green LED light (status and capacity) as below
will be on:
If all the LED light on as normal, which means the battery system is good and working.
(2) Check the battery system’s working status on control module.
(3) Turns the power output switch on:
C. System turn off
(1) Turn off the System Switch.
(2) The Power Output Switch normally needn’t switch off.
Caution:
Before change the battery module for service, must charge/discharge the replaced battery
same voltage to the other in system battery modules. Otherwise the system need long time to do
the balance for this replaced battery module.
NOTE
After installation, do not forget to register online for full warranty:
www.pylontech.com.cn/service/registration
Other manuals for PowerCube-X1
1
This manual suits for next models
1
Table of contents
Other Pylon Technologies Storage manuals
Popular Storage manuals by other brands

Cavalry
Cavalry CADA-SA2 Series instruction manual

HP
HP StorageWorks 4000/6000/8000 - Enterprise Virtual... release note

HP
HP XP7 user guide

Western Digital
Western Digital WDH1S5000 - My DVR Expander 500 GB External Hard... Specifications

Delfield
Delfield Shelleyglas KFW-1-NU Installation, operation and maintenance manual

Spectra
Spectra T50e Installation