RINS1559-4
GREEN PULSING
Connecting to network
ORANGE ON
When making a call
ORANGE
ORANGE GREEN
SIGNAL STRENGTH
ON = Signal Strength Full
SIGNAL STRENGTH
ON = Signal Strength 50%
SIGNAL STRENGTH
OFF = No Signal Strength
12V DC
Connection
Modem
Data
Connection
SIM
CARD
slot
Inserting a SIM Card
SIM CARD NOT PROVIDED
The GSM Modem is compatible with GSM networks
and will not work with networks that provide a 3G
Signal only (for example the 3 network).
The Printed Circuit Board LED Status
The DIGI-GSM is only available for the PCX 46 and Enforcer V9 and above.
Antenna
Connection
Status
LEDs
Troubleshooting:
- If no signal strength is displayed, try relocating the
antenna in a new location.
- If the GSM is not dialling out, check the modem is
enabled in programming, the SIM card is inserted and
the modem data connection is connected correctly. Also
check to see if the GREEN LED is pulsing which will
show that it is connecting to the network.
- If no LEDs are displayed, check the power connection
or connect a separate +12V to the GSM
- If the GSM is not recognised with the control panel,
power down and back up.
x4
LARGE HOUSING:
8x Screws
M3 x 5
4x Pillars
M3 x 8
SMALL HOUSING:
4 x Screws
4x1/4
ENFORCER HOUSING:
Clips into place
DIGI-GSM
GSM Digital Communicator
T: +44(0)845 6434 999 (local rate) Or T: +44(0)1709 535225 (For Alarm Engineer only)
Customer Support opening hours: 8:00am – 6.30pm Monday to Friday
Pyronix Ltd, Secure House, Braithwell Way, Hellaby, Rotherham, South Yorkshire, S66 8QY.
E: customer[email protected]. W: www.pyronix.com
The GSM module is used to communicate either via Contact ID, Fast Format or SMS. It will also enable
remote uploading/downloading via a PC to the control panel.
NOTE: The availability of these features is dependent on the network operator for the SIM card used in the
modem. Not all networks will support all the features. Also check periodically the credit of SIM card.
Antenna: The supplied antenna must be connected as shown above. The antenna then must be situated in a
position where the signal strength is high - this can be monitored via the LEDs.
Printed Circuit Board
12V DC Connection: The power connection for the GSM Module.
Modem Data Connection: Connection for data to the control panel.
SIM Card: Must be present for the GSM to operate
Technical Specification:
Formats: Fast Format, Contact ID, SMS , supports upload/downloading
Baud Rate: 9600bps
Voltage: +12VDC
Quiescent: 40mA (In use: 420mA)
Dimensions: 110 x 56 x 10mm
Please see the control panel (that this is being connected to) user, programming and quick set up manuals for
further information. Minimum time for the detection of GSM fault signal = 2 minutes 30 seconds.
Connection to the PCX 46 (Export only) control panel
GSM Antenna
Information : The Digi-GSM can only be used on PCX 46 (Export only) and
Enforcer version 9 and above control panels.
For electrical products sold within the
European Community. At the end of the
electrical products useful life, it should not
be disposed of with household waste.
Please recycle where facilities exist. Check
with your Local Authority or retailer for
recycling advice in your country.
NOTE: When connecting the GSM, make
sure the control panels mains and battery
are powered down.
NOTE: When connecting a Digi GSM to the Enforcer control panel, please use the power connector
marked ‘GSM modem’ on the inside of the plastics.
Compliance:
Security Grade 2
Environmental Class II
EN 61000-6-3:2007
EN 50130-4: 2011
EN 60950-1:2006 +A12: 2011.
ETSI EN 301 511:V9.0.2
ETSI EN 301 489-1 V1.8.1/ -7 V1.3.1
EN 50136-1-1: 1998 + A2: 2008
EN 50136-2-1: 1998 + A1: 2001
ATE INPUTS

Popular Cell Phone manuals by other brands

myPhone Prime 3 Lite user manual

myPhone

myPhone Prime 3 Lite user manual

Lenovo motorola Moto Z Droid Service and repair manual

Lenovo

Lenovo motorola Moto Z Droid Service and repair manual

Sigma X-treme PQ51 user manual

Sigma

Sigma X-treme PQ51 user manual

Zte AXON 10PRO user manual

Zte

Zte AXON 10PRO user manual

Samsung SM-J337T user manual

Samsung

Samsung SM-J337T user manual

Samsung GT-N7100 quick start guide

Samsung

Samsung GT-N7100 quick start guide

LG LG-D686 Quick reference guide

LG

LG LG-D686 Quick reference guide

LG GD910 user guide

LG

LG GD910 user guide

Vivax PRO M10 instruction manual

Vivax

Vivax PRO M10 instruction manual

Zte Baker Start guide quick

Zte

Zte Baker Start guide quick

LG GS102 user guide

LG

LG GS102 user guide

QVC E226061 manual

QVC

QVC E226061 manual

Samsung Jitterbug SPH-A120 manual

Samsung

Samsung Jitterbug SPH-A120 manual

NEC e616 user guide

NEC

NEC e616 user guide

Telstra Evolution T80 user guide

Telstra

Telstra Evolution T80 user guide

LG U8120 Service manual

LG

LG U8120 Service manual

Micromax S300 manual

Micromax

Micromax S300 manual

Pidion BM-170 user guide

Pidion

Pidion BM-170 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.