1 – ACTIVE/PASSIVE ARMING:
Whenactive armingisselected,thesystem willonly armwhen thetransmitter isused.
Whensettopassive,thesystemwillarmautomatically30secondsafterthelastdoorisclosed.Passivearmingisindicated
by the rapid flashing of the LED when the last protected entry point is closed.
2 – ARM/DISARM CHIRPS ON/OFF:
This feature controls the chirps that confirm the arming and disarming of the
system.
3 – IGNITION CONTROLLED DOOR LOCKS ON/OFF:
When turned on, the doors will lock three seconds after the
ignition is turned on and unlock when the ignition is turned off. The doors will not lock if the ignition is turned on with the
door open.
4–ACTIVE/PASSIVELOCKING:
Ifpassivearmingisselectedinstepone,thenthesystemcanbeprogrammedtoeither
lock the doors when passive arming occurs, or only lock the doors when the system is armed via the transmitter. Active
locking means the system will not lock the doors when it passively arms. Passive locking means that the system will lock
the doors when it passively arms.
5 PANIC WITH IGNITION ON:
This step controls whether or not the panic mode is available with the ignition on. In
some states, there are laws prohibiting a siren sounding in a moving vehicle. This feature makes the system compliant
with these regulations.
6 DOORLOCKPULSEDURATION:
SomeEuropeanvehicles,suchasMercedes-BenzandAudi,requirelongerlock
andunlockpulsestooperatethevacuumpump.Programmingthesystemtoprovide3.5secondpulses,willaccommodate
door lock interface in these vehicles. The default setting is .8 second door lock pulses.
See "Mercedes-Benz and Audi
- 1985 and Newer (Type E)"
diagram on page 15.
7 – FORCED PASSIVE ARMING ON/OFF:
To use this feature, passive arming must be selected in step one. When
turnedon,forcedpassivearmingwillensurethatthesystemwillpassivelyarm,evenifazoneisleftopenorinvalid.Forced
passive arming occurs one hour after the ignition is turned off.
8–AUTOMATICENGINEDISABLE(AED)ON/OFF:
AEDisafulltime,passivestarterdisablethatworksindependently
of the security system. If AED is desired, the optional Starter Kill Relay must be installed. When turned on, the H1/1
ORANGE, ground when armed output will go active 30 seconds after the ignition is turned off. The LED will flash at half
its normal rate when the ignition is turned off to indicate that AED is on and will interrupt the starter in 30 seconds. AED
does not occur in Valet® Mode and can be bypassed using the emergency override procedure. The transmitter can be
used to disarm AED, however, the system would have to be armed and then disarmed when using the transmitter.
9 –VEHICLE RECOVERY SYSTEM (VRS
®
) ENABLED/DISABLED:
This feature is used to tell the system whether
or not the VRS® button has been installed. As shipped, the VRS® is disabled. If installing the VRS® button, you will
need to enable the VRS®.
10–CODE-HOPPING™ON/OFF:
Thesystemusesamathematicalformulatochangeitscodeeachtimethetransmitter
and receiver communicate. This makes the group of bits or "word" from the transmitter very long. The longer the word
is, the easier it is to block its transmission to the unit. Disabling the Code-Hopping™feature lets the receiver ignore the
Code-Hopping™part of the transmitter word. As a result, the unit may have better range with Code-Hopping™off.
11 – SIREN/HORN HONK:
The system can be programmed to output pulses instead of a continuous output when the
system is triggered. This is useful to honk the factory horn in applications where a siren is undesirable. Remember that
theunitisonly capableofsupplying 1ampoffcurrent.Arelaywillbe requiredtointerface withmostfactoryhornsystems.
FEATURE DESCRIPTIONS