Qeedji NAPOE109kt User manual

User manual
NAPOE109kt
1.10.12 002B

2
Legal notice
NAPOE109kt 1.10.12 (002B_en)
© 2021 Qeedji
Rights and Responsibilities
All rights reserved. No part of this manual may be reproduced in any form or by any means whatsoever. or by any means whatsoever without the
written permission of the publisher. The products and services mentioned herein may be trademarks and/or service marks of the publisher. or
trademarks of their respective owners. The publisher and the author do not claim any rights to these Marks.
Although every precaution has been taken in the preparation of this document, the publisher and the author assume no liability for errors or
omissions, or for damages resulting from the use of the information contained in this document or the use of programs and source code that can go
with it. Under no circumstances can the publisher and the author be held responsible for any loss of profits or any other commercial prejudice caused
or alleged to have been caused directly or indirectly by this document.
Product information
Product design and specifications are subject to change at any time and `Qeedji` reserves the right to modify them without notice. This includes the
hardware, the embedded software and this manual, which should be considered as a general guide to the product. The accessories supplied with the
product may differ slightly from those described in this manual, depending on the developments of the various suppliers.
Precautions for use
Please read and heed the following warnings before turning on the power: - installation and maintenance must be carried out by professionals. - do
not use the device near water. - do not place anything on top of the device, including liquids (beverages) or flammable materials (fabrics, paper). - do
not expose the device to direct sunlight, near a heat source, or in a place susceptible to dust, vibration or shock.
Warranty clauses
The `Qeedji` device is guaranteed against material and manufacturing defects for a certain duration. Check the device warranty duration value at the
end of the document. These warranty conditions do not apply if the failure is the result of improper use of the device, inappropriate maintenance,
unauthorized modification, operation in an unspecified environment (see operating precautions at the beginning of the manual) or if the device has
been damaged by shock or fall, incorrect operation, improper connection, lightning, insufficient protection against heat, humidity or frost.
WEEE Directive
This symbol means that your appliance at the end of its service life must not be disposed of with household waste, but must be taken to a collection
point for waste electrical and electronic equipment or returned to your dealer. Your action will protect the environment. In this context, a collection
and recycling system has been set up by the European Union.

3
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
2.1
2.2
3.1
4.1
Table of contents
Part I : Description and installation
Introduction
Faces
Device dimensions
Labelling
Connectors
KRONE connector crimping
Diagnostic test
Device fixture
Device uninstallation
KRONE connector removing
KRONE connector insertion
Part II : Technical information
Technical specifications
Conformities
Part III : Contacts
Contacts
Part IV : Appendix
Appendix: Type B or type A RJ45 cable PIN out

4
Part I Description and installation

5
1.1 Introduction
The NAPOE109kt device is a dual role data Ethernet to TAB10s adapter. Once connected to a Ethernet cable supporting PoE, it can provide power
supply and IP network connectivity to a TAB10s device.
The NAPOE109kt device is intended to be crimped through a KRONE connector, on an Ethernet multi-stranded cable supporting PoE IEEE802.3af (5E
category minimum) then to be fixed inside a wall flush-mounted box.
This manual explains how to:
crimp the provided KRONE connector,
install the NAPOE109kt device,
test the power connectivity of the KRONE connector.
Recommendations and warnings
This device is designed for indoor use only.
◬
In the nominal mode, it is normal that the device is hot. It is advised to take precaution before handling the device with your hand.
Package Contents
Articles Description Quantity
Device NAPOE109kt device 1
KRONE connector Removable connector to be crimped on a network cable 1
Cable clamp Clamp to tighten the network cable on the NAPOE109kt device 1
Serrated washers Ensure the tightness of the NAPOE109kt device on the wall flush-mounted box
Internal ∅: 3.2 mm (0.118 "), external ∅: 6 mm (0.236 "), thickness: 2 mm (0.078 ") 2
☛ When coming straight from factory, the KRONE connector is already plugged on the NAPOE109kt device.

6
1.2 Faces
Side face
1 electrical pads supporting data and power delivery,
2 bevelled support to hang the TAB10s device,
3 removable KRONE connector ,
4 power red LED,
5 status green LED for network gigabit connection ,
6 status green LED for network activity,
7 dipswitch allowing to:
activate or inativate the LED lightening,
activate or inactivate the data and power connectivity on the POGO connector or on the USB-C connector,
8 holes to host screws to lock the TAB10s device on the NAPOE109kt device,
10 holes to fix the device on the wall flush-mounted box.
Front face
1 electrical pads supporting data and power delivery,
2 bevelled support to hang the TAB10s device,
10 11 12 13 ¹ holes to fix the device on a wall flush-mounted box.
8 9 holes hosting screws to lock the TAB10s device on the support.²
¹ It is advised to mount the wall flush-mounted box with a specific orientation. For further information, refer to the chapter § Device fixture.
² The suitable screws are provided with the TAB10s device.
Rear face
1
2
3
4
5
6
7
8
10
1
2
8
9
10
11
12
13

8
1.3 Device dimensions

9
1.4 Labelling
Product label
The model of the device, the power supply characteristics, the serial number (PSN) and the MAC address are written on a label stuck on the case.
☛ The QR code on the product label is corresponding to the product identification URL, for example:
i.qeedji.tech?model=NAPOE109kt&sn=01400-00001&mac.lan1=00-1C-E6-02-52-64 .
☛ FCC certification in pending.
Packingbox label
This is the label stuck also on the packingbox. It is showing:
the device model,
the product serial number (PSN) (embedded also in the QR code),
the manufacturer Web site.
☛ The QR code on the packingbox label is corresponding to the product PSN, for example:
PSN01400-00001 CD0 .
Some additional labels may be present in case of built-in options.
☛ The serial number of the device could be requested in case of technical support.

10
1.5 Connectors
KRONE connector
The KRONE connector needs to be crimped on a Ethernet multi-stranded cable. For further information, refer to the chapter § KRONE connector
crimping.
Dipswitch
In the default factory configuration, the dipswitch is configured in nominal mode 1.
In the nominal mode, dual role data and power delivery are supported over the electric pad of the POGO connector,
If a external power supply is detected over the USB type C connector, this power supply is used and the one coming from the PoE cable is not used.
☛ In the nominal mode the LEDs lightening is inactived.
To set the device in diagnostic mode 2, helped with a pencil lead, set the dipswitch to the left.
☛ In diagnostic mode, the LED lightening for power and network activity is activated.
After having completed the diagnostic test, helped with a pencil lead, set the dipswitch back to the right in nominal mode. For further information,
refer to the chapter § Diagnostic test.
1
2

12
1.6 KRONE connector crimping
The NAPOE109kt device is hosting a KRONE connector which has to be crimped by a qualified person on a Ethernet multi-stranded cable supporting
PoE IEEE802.3af (5E category minimum).
☛ The NAPOE109kt device is delivered straight from factory with the KRONE connector already plugged on the device.
◬
The crimping step must be realized by using a crimping pliers for RJ11, RJ12, RJ45 cable, standard tool used by electricians, to ensure that
the wires are properly crimped on the KRONE connector. Else some unexpected trouble like network connectivity, gigabit capability issue may
be faced.
◬
Before crimping the KRONE connector, check that the Ethernet cable cross the wall flush-mounted box. For further information, refer to the
chapter § Device fixture.
◬
Before crimping the KRONE connector, check whether the Ethernet cable is type A or type B. That defines the RJ45 cable crimping PIN out.
For further information, refer to chapter § Appendix: Type B or type A RJ45 cable PIN out.
KRONE connector PIN out
The PIN from 1 to 4 of the KRONE connector are always plugged to the same color. For the PIN 5 to 8, you need to know the type of the RJ45 cable used.
☛ The A letter 12 and B letter 13 are helping electricians to crimp appropriate wires of the type A or type B RJ45 cable on the KRONE connector.
Location Type B RJ45 wire color Required for
10/100 Mbps Required for
10/100/1000 Mbps
1white + blue no¹ yes
2blue no¹ yes
3brown no¹ yes
4white + brown no¹ yes
5green yes yes
6white + green yes yes
7orange yes yes
8white + orange yes yes
Location Type A RJ45 wire color Required for
10/100 Mbps Required for
10/100/1000 Mbps
1white + blue no¹ yes
2blue no¹ yes
3brown no¹ yes
4white + brown no¹ yes
5orange yes yes
6white + orange yes yes
7green yes yes
8white + green yes yes
¹ When the sink device supports only 10/100 Mbits network bandwidth, the crimping of these wires is optional.
1
2
3
4
5
6
7
8
12
13

13
◬
The provided cable clamp 10 needs to be tightened over the cable jacket using the ring on the top face. So before crimping the wires,
ensure that the cable jacket extremity 9 is as close as possible to the KRONE connector 11 . It is advised that the colored wires before
crimping have 50 mm length.
KRONE connector uncrimping
It is possible to uncrimp the KRONE connector from the Ethernet multi-stranded cable. It is advised to use a pliers to remove the wished wires.
☛ The crimping pliers often support a tool to uncrimp wires.
9
10
11

14
1.7 Diagnostic test
The diagnostic test consists in testing the KRONE connector crimping before fixing it definitively inside a junction box or a cable trunking.
☛ After the diagnostic test is completed, this NAPOE109kt device is intended to work in nominal mode with the dipswitch position to the right.
nominal mode diagnostic mode
POGO data yes no
POGO power delivery yes yes
USB-C data no yes¹
USB-C power delivery (output) no no
USB-C power input yes yes²
LEDs lightening inactivated activated
¹ Connectivity test with mobile supported.
² It is advised to unplug the TAB10s device from the NAPOE109kt device.
Power connectivity
Prerequisite:
during the test, the RJ45 cable has to deliver power according to PoE IEEE802.3af,
the KRONE connector is properly crimped on the right PIN according to the RJ45 cable type,
the KRONE connector is properly plugged on the NAPOE109kt device.
To test the power connectivity, set the dipswitch position to the left in the diagnostic mode activating the LED lightening.
If the power red LED is ON and steady, The KRONE connector is properly crimped on a PoE RJ45 cable. Consequently and the NAPOE109kt device is
powered properly.
☛ Each time the dipswitch is set from the right position to the left position, the device is rebooting once.
◬
After having completed the test of the power connectivity, set back the dipswitch position to the right to return to the nominal mode.

15
LED behaviour
Mode Network activity LED
behaviour Information
Connectivity
test On for 250 ms then off After power unplug/replug or immediately after the dipswitch is turned from right to left.
The NAPOE109kt device is powered properly and crimped¹ on the PoE cable supporting
network data.
Connectivity
test blinking Blinking² as soon as network activity is detected over USB-C connector.
Nominal Off In nominal mode, the gibabit connexion LED and the network activity LED lightening are
inactivated.
² If the network activity LED is not blinking despite of an appropriate power supply leading to the test phone mobile which can not access to the
network, try again after having restarted the switch.
Mode Gibabit connexion LED
behaviour Information
Connectivity
test On for 250 ms then off After power unplug/replug or immediately after the dipswitch is turned from right to left.
The NAPOE109kt device is powered properly and crimped¹ on the PoE cable.
Connectivity
test On The device is connected to a network connexion supporting gigabit¹ (or behind a gigabit
switch).
Nominal Off In nominal mode, the gibabit connexion LED and the network activity LED lightening are
inactivated.
Mode Red LED behaviour Information
Connectivity test On (steady) The NAPOE109kt device is powered properly.
Nominal Off In nominal mode, the power LED lightening is inactivated.
◬
¹ conclusion worths only when no sink device is connected.

16
1.8 Device fixture
Wall flush-mounted box features and installation
☛ The hole allowing to host the wall flush-mounted box must be done with an hole saw having the appropriate diameter. Then the wall flush-
mounted box has to be fixed in the hole by a qualified person.
◬
To know the TAB10s device fixture height, refer to the legislation in force in your country, related to the accessibility to disabled persons of
establishments open to the public during their construction and of facilities open to the public during their development.
☛ The legislation in force in France implies to install the top of the display at 130 cm (or 51,1811 ") maximum far from the floor. Remove 9.2 cm (or
3.543 ") to this height to determine the height of the hole center to insert the wall flush-mounted box. For example, for the France country, the
hole center should be drilled at (130 - 9.2) = 120.8 cm (47,24 ") far from the floor.
☛ The wall flush-mounted box must have a sufficient volume to host the NAPOE109kt device. The distance 1 between the screws must be 60 mm
(2.362 ").
☛ The wall flush-mounted box type is depending on the wall material. Consequently it is not provided in the packing box.
☛ It is common for the hole saw diameter to be 68 mm (2.67") to make the hole for your flush mount box. However, to confirm the actual drilling
diameter, refer to the drilling requirements of your flush mount box.
◬
It is recommended to install the wall flush-mounted box with the following orientation, with its clamping claws up 2 and down 3. Then
the NAPOE109kt device with be tightened with the left screw 4 and the right screw 5.

17
◬
Before to be fixed, the NAPOE109kt must be properly crimped on a Ethernet multi-stranded cable. For further information, refer to the
chapter § KRONE connector crimping.
Untighten the left and right screw of the wall flush-mounted box to add the provided serrated washers.
◬
The NAPOE109kt must be firmly installed by a qualified person on the wall flush-mounted box by using the provided serrated washers.
Add the provided serrated washers to the screws of the wall flush-mounted box.
Stand the NAPOE109kt device properly in front of the wall flush-mounted box. Tighten back now the left and right screw on the wall flush-mounted
box.
◬
Once tightened, by using a levelling rod, double check that the upper edge of the NAPOE109kt device is strickly horizontal.
1
2
3
4
5

18
The TAB10s device can be then hung properly on the NAPOE109kt device. For further information, refer to the TAB10s user manual.

19
1.9 Device uninstallation
For further information, refer to the chapter § KRONE connector removing.
☛ In case you had to install the device in another location, you have to uncrimp the current KRONE connector from the Ethernet multi-stranded
cable. For further information, refer to the chapter § KRONE connector crimping.
Table of contents