INSTALLATION & USER GUIDE
LEAK DETECTOR WITH AUTO SHUT-OFF
INTRODUCTION
This guide explains how to install a QETTLE Leak Detector. The
guide covers the installaon process for installing the Leak
Detector in conjuncon with a new QETTLE system, or when retro-
ng to an exisng QETTLE installaon. Correctly installed and
properly maintained in accordance with the following instrucons,
it will provide you with many years of reliable service.
Study the diagrams, read this guide and plan the layout carefully
before proceeding.
PLAN THE LOCATION FOR THE LEAK DETECTOR
• IMPORTANT NOTE: The leak detector must be posioned on the base of the kitchen cabinet, on a at surface, with the 2 x
metal plates facing down. The 2 x metal plates must be in contact with the base of the cabinet.
• The opmum locaon for the leak detector is an area between the boiler tank, undersink chiller (if applicable), and the
lter housing. The goal with selecng the locaon is to place the leak detector in the best locaon to detect leaks from any
component of the system.
• Ensure the selected locaon for the leak detector is within reach (1.5 metres) of the Auto-Shut O Valve.
• IMPORTANT NOTE: Always install the leak detector in conjuncon with the mechanical shut-o valve supplied with all
QETTLE systems.
TECHINCAL DATA
Operang Voltage: 9V DC
Cable Length: 1.5M
Connecons: 1/2” BSP Female to 1/2” BSP Male
Minimum Operang Temperature: 20°C
Maximum Operang Temperature: 80°C
Maximum Pressure: 5 BAR (73psi)
COMPONENT LIST
1. Auto-Shut O Valve
2. Leak Detector
3. Leak Detector Cover
4. Label
5. 9V Baery
THE INSTALLATION PROCEDURE
The rst steps of the installaon will vary depending on whether the Leak Detector is being installed as part of a new QETTLE
system installaon or whether you are retro-ng it to an exisng installaon. Please follow the applicable secons outlined
below...
Installaon as a Retro-t
1. Switch o the electricity to your tap’s boiler tank by using the switch located on the front of the tank.
2. Run the boiling water unl the water runs cold—this will take a good couple of minutes or so.
3. Under the sink, shut o the water supply to your tap’s lter unit using the adjacent shut-o valve. Run the ltered cold and
ltered boiling water alternately again to de-pressurise the system.
4. Unscrew the inlet hose to the lter housing from the shut-o valve. The hose will contain water, so we recommend having a
towel or cloth to hand and a receptacle to catch any residual water.
5. Now follow the remaining steps outlined in the ‘Main Installaon Process’ secon below.
Installaon with a new QETTLE system
1. You should begin installing the Leak Detector once you have completed the steps outlined in ‘THE PLUMBING’ secon found
on page 5 of the QETTLE system installaon guide. Once you have got to that stage please follow the remaining steps out-
lined in the ‘Main Installaon Process’ secon below.
MAIN INSTALLATION PROCESS
• Screw the Auto-Shut o valve (1) on to the mechanical shut-
o valve supplied with the QETTLE system sucient to make
a waterght seal. IMPORTANT NOTE Do not overghten.
• Screw the ltered water inlet hose on to the Auto-Shut o
valve sucient to make a waterght seal. IMPORTANT NOTE
Do not overghten.
• Plug the cable from the Leak Detector (2) into the port on
the cable aached to the Auto-Shut o valve (1).
• Place the leak detector cover (3) into posion. The cover
should be posioned with the opening easily accessible to
allow for easy removal of the leak detector (IMPORTANT
NOTE if you placing the leak detector on to a cabinet with a
metal base you must sck the Scker (4) provided on to the
metal base rst. The Scker prevents a circuit being made
and the Auto-Shut o from triggering when it is placed in
posion). Remove the backing on the Velcro pads and rmly
push the cover into posion.
• Install the 9V Baery (5) into the leak detector. Remove the
cover on the side of the leak detector and install the baery.
Once the baery is installed the leak detector will beep and
both the lights on the front will turn on for 3 seconds.
• Press and hold the reset buon on the front of the leak
detector for 5 seconds. The leak detector will beep and the
blue light on the front will turn on for 3 seconds. The leak
detector is now acve.
• Place the leak detector in posion underneath the cover. Be
careful not to accidentally acvate the leak detector when
sliding underneath the cover when the base of the cabinet
is metal.
• Turn the water supply back on to the system using the me-
chanical shut o valve and check for leaks.
• Turn the power back on to the boiler. The system is now
ready for use.
IMPORTANT NOTE: use the scker provided when
installing the leak detector on a Metal Cabinet Protector.
Qele is a trading name of Greg Rowe LimitedPart No: 999593
Qele
Old Winery Business Park
Chapel Street
Cawston, Norfolk
NR10 4FE
Phone: +44 (0)1603 875 464
Email: support@qele.com
CARE AND MAINTENANCE
Reseng the Leak Detector
To reset the Leak Detector and turn the ow of water back on, press and hold the Reset buon on the front of the Leak Detector
for 5 seconds. The Leak Detector will beep and the blue light on the front will turn on for 3 seconds. Aer this water should begin
owing through the system again.
Low Power Warning
The Leak Detector will connuously beep and the Baery light on the front will ash red when the power in the baery is geng
low. You should immediately change the baery to ensure that the Leak Detector connues to funcon. Failure to replace the
baery will eventually result in the Leak Detector shung o the water to the system.
Changing the Baery
To change the baery remove the Leak Detector from underneath the cover and remove the cover on the side of the leak
detector. Remove the old 9V Baery and replace with a new one. Once the new baery is installed the leak detector will beep
and both the lights on the front will turn on for 3 seconds.
GUARANTEE
This Qele product carries a 1-year guarantee against material
and manufacturing defects.
You should also retain your dated invoice as proof of purchase
to validate any claims under our guarantee. The guarantee
will be valid from the date of purchase as shown on the sales
invoice. This appliance is intended for domesc use only.
The guarantee does not apply to products installed outside a
domesc environment.
WHAT IS COVERED BY THE QETTLE GUARANTEE?
The repair or replacement of all or part of the unit if the unit is
found to be defecve due to faulty materials or manufacture
within the relevant guarantee periods at Qele’s discreon.
If any part is no longer available, or out of manufacture, Qele
reserve the right to replace it with a suitable alternave.
TERMS AND CONDITIONS OF THE QETTLE 1 YEAR GUARANTEE
The guarantee is valid for the UK.
The guarantee becomes eecve at the date of purchase or at
the date of delivery if this is later.
Proof of purchase is required under the terms of the
guarantee.
The guarantee provides benets in addion to your statutory
consumer rights.
QETTLE DOES NOT GUARANTEE THE REPAIR OR
REPLACEMENT OF A PRODUCT THAT HAS FAILED FOR ANY OF
THE FOLLOWING REASONS:
• Faulty installaon, repairs or alteraons not in accordance
with the installaon guide.
• Normal wear and tear.
• Accidental damage or faults caused by negligent use or
care; misuse; neglect; careless operaon and failure to
use the system in accordance with the Qele operang
guidelines.
• The use of anything other than genuine Qele replacement
parts.
• Failures of, or failures caused by, parts not supplied as part
of the genuine Qele system.
HOW DO I MAKE A CLAIM UNDER MY GUARANTEE?
If you are in doubt about what is covered by your
guarantee, or wish to discuss a claim, please call please
call Qele on 01603 875 464 Monday to Friday between
the hours of 9.00am and 5.00pm.
If you are calling for the rst me please have your receipt to
hand so that we can record your date of purchase.
The company reserves the right to alter, change or modify
product specicaons without prior noce.

Popular Security Sensor manuals by other brands

SOMFY Movement Detector io manual

SOMFY

SOMFY Movement Detector io manual

Pilz PSEN 2.1p-41 operating manual

Pilz

Pilz PSEN 2.1p-41 operating manual

Reno GT-200-LRT operating instructions

Reno

Reno GT-200-LRT operating instructions

Oregon Scientific MSR939 user manual

Oregon Scientific

Oregon Scientific MSR939 user manual

BW GasAlert Quattro user manual

BW

BW GasAlert Quattro user manual

jablotron GS-133 quick start guide

jablotron

jablotron GS-133 quick start guide

DSC PG9934(P) installation instructions

DSC

DSC PG9934(P) installation instructions

Edwards ELD500 Series instruction manual

Edwards

Edwards ELD500 Series instruction manual

iMSENS iMSL Plafon Urano quick start guide

iMSENS

iMSENS iMSL Plafon Urano quick start guide

Nobile 9109011005 Mounting and operation instructions

Nobile

Nobile 9109011005 Mounting and operation instructions

Vimar EIKON 20184 manual

Vimar

Vimar EIKON 20184 manual

Hytronik HIM84 Installation and instruction manual

Hytronik

Hytronik HIM84 Installation and instruction manual

Thorn SensaLite SLOCS Installation and commissioning instructions

Thorn

Thorn SensaLite SLOCS Installation and commissioning instructions

Leedarson LDHD2AZW installation guide

Leedarson

Leedarson LDHD2AZW installation guide

Pantron ISM-2800 operating instructions

Pantron

Pantron ISM-2800 operating instructions

SENTRONIC AM300 Series user guide

SENTRONIC

SENTRONIC AM300 Series user guide

Roland ZBX-540E Assembly instructions

Roland

Roland ZBX-540E Assembly instructions

Argus Security ALTAIR Series quick start guide

Argus Security

Argus Security ALTAIR Series quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.