Qettle AS-414 Operation manual

INSTALLATION & USER GUIDE
LEAK DETECTOR WITH AUTO SHUT-OFF

INTRODUCTION
This guide explains how to install a QETTLE Leak Detector. The
guide covers the installaon process for installing the Leak
Detector in conjuncon with a new QETTLE system, or when retro-
ng to an exisng QETTLE installaon. Correctly installed and
properly maintained in accordance with the following instrucons,
it will provide you with many years of reliable service.
Study the diagrams, read this guide and plan the layout carefully
before proceeding.
PLAN THE LOCATION FOR THE LEAK DETECTOR
• IMPORTANT NOTE: The leak detector must be posioned on the base of the kitchen cabinet, on a at surface, with the 2 x
metal plates facing down. The 2 x metal plates must be in contact with the base of the cabinet.
• The opmum locaon for the leak detector is an area between the boiler tank, undersink chiller (if applicable), and the
lter housing. The goal with selecng the locaon is to place the leak detector in the best locaon to detect leaks from any
component of the system.
• Ensure the selected locaon for the leak detector is within reach (1.5 metres) of the Auto-Shut O Valve.
• IMPORTANT NOTE: Always install the leak detector in conjuncon with the mechanical shut-o valve supplied with all
QETTLE systems.
TECHINCAL DATA
Operang Voltage: 9V DC
Cable Length: 1.5M
Connecons: 1/2” BSP Female to 1/2” BSP Male
Minimum Operang Temperature: 20°C
Maximum Operang Temperature: 80°C
Maximum Pressure: 5 BAR (73psi)
COMPONENT LIST
1. Auto-Shut O Valve
2. Leak Detector
3. Leak Detector Cover
4. Label
5. 9V Baery

THE INSTALLATION PROCEDURE
The rst steps of the installaon will vary depending on whether the Leak Detector is being installed as part of a new QETTLE
system installaon or whether you are retro-ng it to an exisng installaon. Please follow the applicable secons outlined
below...
Installaon as a Retro-t
1. Switch o the electricity to your tap’s boiler tank by using the switch located on the front of the tank.
2. Run the boiling water unl the water runs cold—this will take a good couple of minutes or so.
3. Under the sink, shut o the water supply to your tap’s lter unit using the adjacent shut-o valve. Run the ltered cold and
ltered boiling water alternately again to de-pressurise the system.
4. Unscrew the inlet hose to the lter housing from the shut-o valve. The hose will contain water, so we recommend having a
towel or cloth to hand and a receptacle to catch any residual water.
5. Now follow the remaining steps outlined in the ‘Main Installaon Process’ secon below.
Installaon with a new QETTLE system
1. You should begin installing the Leak Detector once you have completed the steps outlined in ‘THE PLUMBING’ secon found
on page 5 of the QETTLE system installaon guide. Once you have got to that stage please follow the remaining steps out-
lined in the ‘Main Installaon Process’ secon below.
MAIN INSTALLATION PROCESS
• Screw the Auto-Shut o valve (1) on to the mechanical shut-
o valve supplied with the QETTLE system sucient to make
a waterght seal. IMPORTANT NOTE Do not overghten.
• Screw the ltered water inlet hose on to the Auto-Shut o
valve sucient to make a waterght seal. IMPORTANT NOTE
Do not overghten.
• Plug the cable from the Leak Detector (2) into the port on
the cable aached to the Auto-Shut o valve (1).
• Place the leak detector cover (3) into posion. The cover
should be posioned with the opening easily accessible to
allow for easy removal of the leak detector (IMPORTANT
NOTE if you placing the leak detector on to a cabinet with a
metal base you must sck the Scker (4) provided on to the
metal base rst. The Scker prevents a circuit being made
and the Auto-Shut o from triggering when it is placed in
posion). Remove the backing on the Velcro pads and rmly
push the cover into posion.
• Install the 9V Baery (5) into the leak detector. Remove the
cover on the side of the leak detector and install the baery.
Once the baery is installed the leak detector will beep and
both the lights on the front will turn on for 3 seconds.
• Press and hold the reset buon on the front of the leak
detector for 5 seconds. The leak detector will beep and the
blue light on the front will turn on for 3 seconds. The leak
detector is now acve.
• Place the leak detector in posion underneath the cover. Be
careful not to accidentally acvate the leak detector when
sliding underneath the cover when the base of the cabinet
is metal.
• Turn the water supply back on to the system using the me-
chanical shut o valve and check for leaks.
• Turn the power back on to the boiler. The system is now
ready for use.
IMPORTANT NOTE: use the scker provided when
installing the leak detector on a Metal Cabinet Protector.

Qele is a trading name of Greg Rowe LimitedPart No: 999593
Qele
Old Winery Business Park
Chapel Street
Cawston, Norfolk
NR10 4FE
Phone: +44 (0)1603 875 464
Email: support@qele.com
CARE AND MAINTENANCE
Reseng the Leak Detector
To reset the Leak Detector and turn the ow of water back on, press and hold the Reset buon on the front of the Leak Detector
for 5 seconds. The Leak Detector will beep and the blue light on the front will turn on for 3 seconds. Aer this water should begin
owing through the system again.
Low Power Warning
The Leak Detector will connuously beep and the Baery light on the front will ash red when the power in the baery is geng
low. You should immediately change the baery to ensure that the Leak Detector connues to funcon. Failure to replace the
baery will eventually result in the Leak Detector shung o the water to the system.
Changing the Baery
To change the baery remove the Leak Detector from underneath the cover and remove the cover on the side of the leak
detector. Remove the old 9V Baery and replace with a new one. Once the new baery is installed the leak detector will beep
and both the lights on the front will turn on for 3 seconds.
GUARANTEE
This Qele product carries a 1-year guarantee against material
and manufacturing defects.
You should also retain your dated invoice as proof of purchase
to validate any claims under our guarantee. The guarantee
will be valid from the date of purchase as shown on the sales
invoice. This appliance is intended for domesc use only.
The guarantee does not apply to products installed outside a
domesc environment.
WHAT IS COVERED BY THE QETTLE GUARANTEE?
The repair or replacement of all or part of the unit if the unit is
found to be defecve due to faulty materials or manufacture
within the relevant guarantee periods at Qele’s discreon.
If any part is no longer available, or out of manufacture, Qele
reserve the right to replace it with a suitable alternave.
TERMS AND CONDITIONS OF THE QETTLE 1 YEAR GUARANTEE
The guarantee is valid for the UK.
The guarantee becomes eecve at the date of purchase or at
the date of delivery if this is later.
Proof of purchase is required under the terms of the
guarantee.
The guarantee provides benets in addion to your statutory
consumer rights.
QETTLE DOES NOT GUARANTEE THE REPAIR OR
REPLACEMENT OF A PRODUCT THAT HAS FAILED FOR ANY OF
THE FOLLOWING REASONS:
• Faulty installaon, repairs or alteraons not in accordance
with the installaon guide.
• Normal wear and tear.
• Accidental damage or faults caused by negligent use or
care; misuse; neglect; careless operaon and failure to
use the system in accordance with the Qele operang
guidelines.
• The use of anything other than genuine Qele replacement
parts.
• Failures of, or failures caused by, parts not supplied as part
of the genuine Qele system.
HOW DO I MAKE A CLAIM UNDER MY GUARANTEE?
If you are in doubt about what is covered by your
guarantee, or wish to discuss a claim, please call please
call Qele on 01603 875 464 Monday to Friday between
the hours of 9.00am and 5.00pm.
If you are calling for the rst me please have your receipt to
hand so that we can record your date of purchase.
The company reserves the right to alter, change or modify
product specicaons without prior noce.
Popular Security Sensor manuals by other brands

Thorn
Thorn SensaLite SLOCS Installation and commissioning instructions

Leedarson
Leedarson LDHD2AZW installation guide

Pantron
Pantron ISM-2800 operating instructions

SENTRONIC
SENTRONIC AM300 Series user guide

Roland
Roland ZBX-540E Assembly instructions

Argus Security
Argus Security ALTAIR Series quick start guide