PB 1
Non Sparking Explosion Proof LED Tower Lights
STB45ML-Ex
STB45ML-Ex -3-12 -RAG
[Model number] [Layer] [Voltage] [Color]
| | | |
• STB45ML-Ex
•
Layer
1-1
•
Layer
2-2
•
Layer
3-3
•
Layer
4-4
•
Layer
5-5
• 12-DC12V
• 24-DC24V
R-Red
A-Amber
G-Green
B-Blue
W-White
Please scan the QR code
for more
detailed product information.
www.qlight.com
Ordering Specications
54
4020
83dB
Ex
Thank you for purchasing Qlight’s products. Please read this user manual carefully
prior to installation and operation to ensure safe and correct use.
Safety Precautions for Explosion Proof Products
1. During wiring or maintenance, please completely turn off the power of the product. (Failure to follow this may lead to an electric shock.)
2. Do not install the product in locations that subjects it to excessive dust or water other than the conditions designated by the IP protection
ratings indicated for each product. (Failure to follow these instructions may cause a re to the product, electric shock, physical injury,
malfunction or damage to the product.)
3. Do not alter or repair this product. If maintenance or repair service is required, please contact your local Qlight contact point.
(Failure to follow these instructions may lead to re, electric shock, or product damage.)
4. Please apply the correct voltage to the product. (Failure to follow these instructions may lead to re, electric shock, or product damage.)
5.
When the product is applied to a condition that may impact lives or property, please make sure to have a double safety device.
(Failure to follow this may cause damage to property, re, electric shock and loss of life.)
Precaution for Safety
Failure to follow the instructions below may cause a loss of life or serious physical injury.
Please follow the instruction below to ensure safe and correct use of explosion proof products.
1. Explosion proof products should be managed according to explosion-proof regulations. Do not disassemble, assemble, alter or repair
the product arbitrarily.
2.
The temperature rating of the product is the temperature the product will experience at the applied rated voltage and ambient
temperature indicated.
3. Use cable glands that satisfy the product’s explosion proof grade and temperature grade.
4. Unused cable entries must be lled with material that meets the explosion proof grade and temperature rating.
5. Before installing the product, please make sure all cautions indicated on the labels, packaging, and operation manual of the product are
fully understood.
6. Installation, maintenance and repair of the product must be performed by experts in the explosion proof eld, or persons who have
received relevant training.
7. For safety, the product should be installed and operated in environments that avoid high temperature and high pressure.
8. Please follow general safety precautions and avoid installing the product in locations that may generate excessive heat.
9. When installing the product in places where chemicals are located, please make sure that the environment does not have two or more
incompatible chemicals mixed. For safety, please read the instruction manual carefully and be mindful of the chemical compositions
where the product is used.
10. This product requires grounding.
1. Please remove any objects that can interrupt ventilation around the product.
2. Please turn off the power of the product immediately if it fails to operate properly.
3. Carefully wire the product according to each product’s specication.
4. Please be careful in preventing chemicals such as thinner, benzene, etc. in contact with the surface of the product.
5. Do not apply excessive force/impact to the product.
6. Static electricity may be generated by physical contact due to the surface characteristics of this product so please use a wet towel
or anti-static cleaner to remove the foreign substances on the product.
Precautions for Correct Use
Failure to follow the proper instructions may cause damage to property, the product, or malfunction of the product
that would void the warranty.
2 3
Model number
Layer Voltage
Current
Certicates
Weight
Color
STB45BML-Ex
1
AC/DC12V
0.040A 0.26kg
R-Red
AC/DC24V
0.043A 0.26kg
2
AC/DC12V
0.064A 0.30kg
R-Red, G-Green
AC/DC24V
0.055A 0.30kg
3
AC/DC12V
0.088A 0.34kg
R-Red, A-Amber, G-Green
AC/DC24V
0.067A 0.34kg
4
AC/DC12V
0.112A 0.38kg
R-Red, A-Amber, G-Green, B-Blue
AC/DC24V
0.079A 0.38kg
5
AC/DC12V
0.136A 0.42kg
R-Red, A-Amber, G-Green, B-Blue, W-White
AC/DC24V
0.091A 0.42kg
STB45ML-EX
Ø45
LAYER
1
2
3
4
5
L
153
194
235
278
317
10
41
L
101
PCD 30
360°/3-
M4 BOLT
12
Model number
STB45ML-Ex
Range for operating
voltage
DC 12V or 24V
Ex mark
KCs - Ex nR II T6 IP54
(Layer2, 3 only),
Ex nR II T4 IP54
CCC - Ex nR IIC T6 Gc
Ambient operating
temperature
–20°C ≤ Ta ≤ 40°C
Explosion proof Zone
Zone2
Protection rating
IP54
■
General Product Specication
Product Specications
Zone
denitions(Gas)
Zone 1
High risk gas/vapour
Zone 2
Medium risk gas/vapour
Group
denitions(Gas)
GROUP II A
Acetone, Petrol, Methanol, Propane, Toluene
GROUP II B
Ethylene, City gas
GROUP II C
Hydrogen, Acetylene, Carbon sulphide
Maximum
surface
temperature
of electrical
equipment
T1
450
°C
T2
300°C
T3
200°C
T4
135
°C
T5
100
°C
T6
85
°C
Zone
denitions(Dust)
Zone 21
High risk powder/dust
Zone 22
Medium risk powder/dust
Group
denitions(Dust)
GROUP II A
Ignitible bers/yings(more than 0.5mm)
GROUP II B
Non-conductive dusts
GROUP II C
Conductive dusts
■
Explosion Proof Specications
Dimensions
(Units : mm)
※ CE Compliant : AC/DC12V(Layer2, 3 only)
2 3
Grounding Instructions
Mounting Hole Specications
Parts Denition/ Installation
Installation Environment and Protection Rating
• This product is designed to be explosion proof.
• Please make sure to use the product in an environment that meets the specied explosion proof rating and regulations.
•
For further information, please visit our website (www.qlight.com).
• STB45ML-EX can be wired by using both external contact and transistor.
• In case of wiring by transistor, please make sure if it is NPN type or PNP type. Please carefully follow wiring instruction below.
Wiring Instructions
• External power line/ external signal line - UL2464 AWG22(0.3sq) 400mm
• This product can be wired regardless of polarity.
STB45ML-EX-DC STB45ML-EX-DC
Red
Amber
Green
Blue
White
Brown
Black
Red
Amber
Green
Blue
White
Brown
Black
Red
Amber
Green
Blue
White
Brown
Black
Layer1
Layer2
Layer3
Layer4
Layer5
Buzzer Buzzer Buzzer
Layer1
Layer2
Layer3
Layer4
Layer5
Layer1
Layer2
Layer3
Layer4
Layer5
Power Power Power
Fuse Fuse Fuse
Steady Steady Steady
EXTERNAL TRANSISTOR-NPN EXTERNAL TRANSISTOR-PNP
EXTERNAL CONTACT
•
Machine holes on the mounting surface referring to the
diagram below.
M4 ground
contact part
Cover(ABS)
Lens(PC)
Housing(PC)
• First, remove the ange nuts from bolts and place the
product through the mounting surface holes.
• Fasten the ange nuts on the opposite side of the mounting
surface until the product is tightened securely.
• Please use an M4 bolt at the location
marked in the diagram above to ground
the product.
• When connecting the grounding cable,
please use a ring terminal.
•
Please use a ring terminal made of C5212
material as it has the same
electrical prop-
erties of the conductor.
• Please use a grounding cable with a
diameter greater than 4mm.
Sound volume lever
Buzzer Sound Volume Adjustment Instructions
Buzzer volume is reduced by sliding
the volume control lever to the left as
show in the diagram to the left.
(Min. 65dB/m)
Raise/ Increase the buzzer volume
by sliding the control lever to the right
as shown in the diagram to the left.
(Max. 83dB/m)
Flange nut
Cover(AI) -T6
only
3-Ø5 HOLES
Ø17 GABLE GLAND HOLE
PCD 30
Qlight Co., Ltd. www.qlight.com | [email protected]
Head Ofce | Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea
Tel. +82-2-2679-6152(Toll free. +82-80-328-2222) Fax. +82-2-2679-6154
Factory | 185-25, Mukbang-ro, Sangdong-myeon, Gimhae-si, Gyeongsangnamdo, Korea Tel. +82-55-328-1111(Toll free. +82-80-328-1111)
Qlight Overseas Sales Dept |
704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel : +82-51-620-4100
Qlight Public Relations & Marketing Team Ofce | 704 Nakdong-daero, Sasang-gu, Busan, Korea(Eomgung-Dong) Tel. +82-51-245-0017
Qlight USA, Inc. www.qlight.com www.qlightusa.com | [email protected]
3003 North First Street, Suite #341, San Jose, CA 95134 USA Tel. +1 - 408 - 519 - 5740 Fax. +1 - 408 - 519 - 5739
SHANGHAI Qlight Electronic Co., Ltd. www.qlight.com www.qlightcn.com | [email protected]
China Factory/ Shanghai Sales Ofce | #19, Nanda Road, Baoshan Area, Shanghai, China Tel. +86
-
21
-
6651
-
7100 Fax. +86
-
21
-
6315
-
3929
Product Operation Inquiry / Customer Support +82-51-620-4100
You can expect prompt service if you have exact information such as model name, symptom, telephone number and address.
※ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Head office : Suite #1510, STX-V Tower, 128 Gasan digital 1-ro, Geumcheon-gu, Seoul, Korea (Postal Code : 08507)
Factory : 185-25, Mukbang-Ro, Sangdong-Myeon, Gimhae-Si, Gyeongsangnam-Do, Korea (Postal Code : 50805)
For your safety
Specication and dimensions listed in this catalogue subject to change without notice for product quality improvement.
The newest product information is available on our website.(www.qlight.com)
Please read the instruction manual attached to the product carefully before installation and use.
www.qlight.com
EN - STB45ML-Ex -2007A

Other Qlight Light Fixture manuals

Qlight S80AR User manual

Qlight

Qlight S80AR User manual

Qlight S80L User manual

Qlight

Qlight S80L User manual

Popular Light Fixture manuals by other brands

Cooper Lighting INVUE Vision Flood Brochure & specs

Cooper Lighting

Cooper Lighting INVUE Vision Flood Brochure & specs

BEKA Schreder Experts in lightability LEDbay-midi Installation instruction

BEKA Schreder

BEKA Schreder Experts in lightability LEDbay-midi Installation instruction

Cooper Lighting TQS1000QD instruction manual

Cooper Lighting

Cooper Lighting TQS1000QD instruction manual

Philips Lytecaster 2008 specification

Philips

Philips Lytecaster 2008 specification

AmerTac WESTEK DIY Series Instructions for installation

AmerTac

AmerTac WESTEK DIY Series Instructions for installation

Sygonix 2583626 operating instructions

Sygonix

Sygonix 2583626 operating instructions

Rebel Light ZAR0475 user manual

Rebel Light

Rebel Light ZAR0475 user manual

EuroLite LED BRK-12 TCL user manual

EuroLite

EuroLite LED BRK-12 TCL user manual

Pixel Range PixelLine Micro W user manual

Pixel Range

Pixel Range PixelLine Micro W user manual

afx light WASH760-FC user manual

afx light

afx light WASH760-FC user manual

Delta Light CARREE Rs50 S1 manual

Delta Light

Delta Light CARREE Rs50 S1 manual

ARTFOX Lighting FLEX BEAM K8 user manual

ARTFOX Lighting

ARTFOX Lighting FLEX BEAM K8 user manual

Tepex PSF 28 LED-E user manual

Tepex

Tepex PSF 28 LED-E user manual

Lightmybricks 75953 manual

Lightmybricks

Lightmybricks 75953 manual

Claypaky C61602 quick start guide

Claypaky

Claypaky C61602 quick start guide

Inlite MINI SCOPE installation manual

Inlite

Inlite MINI SCOPE installation manual

Pixel Range pixelpar 90 user manual

Pixel Range

Pixel Range pixelpar 90 user manual

Show Tec Infinity iB-5R manual

Show Tec

Show Tec Infinity iB-5R manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.