For further assistance from a Quanser engineer, contact us at
tech@quanser.com or call +1-905-940-3575.
STILL NEED HELP?
©2012 Quanser Inc. All rights reserved. LabVIEW™ is a trademark of National Instruments. V.1 10/10/2012
LEARN MORE To find out about the full range of Quanser control experiments,
visit www.quanser.com
Software Setup
Troubleshooting
STEP 4
STEP 5
Follow the instructions given in the Rapid Control Prototyping (RCP) Toolkit® Installation Guide for the NI CompactRIO
(located on the RCP Toolkit Installation CD) to install LabVIEW™, its necessary add-on modules, and the RCP Toolkit
on both your PC/laptop and on the NI CompactRIO.
See the Troubleshooting section in the Rapid Control Prototyping (RCP) Toolkit® Installation Guide for the NI CompactRIO
for help with the NI CompactRIO and Quanser Q1-cRIO module. For further details, refer to the troubleshooting guide for
the NI CompactRIO device at: http://www.ni. com/gettingstarted/setuphardware/compactrio/troubleshootmax.htm
H
I
Connect the power terminals on the NI CompactRIO
controller to the Quanser Q1-cRIO module as follows:
1. Remove the power connector on the Quanser
Q1-cRIO module by loosening the screws.
2. Connect the V1 and C power terminals on the
NI CompactRIO controller to the + and - terminals
on the Quanser Q1-cRIO module power connector.
Note: Make sure you use the V1 terminal that was
used in Step 3G for the power supply connection.
3. If using multiple Quanser Q1-cRIO modules, daisy
chain the modules by connecting the + terminal
from one module to the + terminal on the other.
Do the same for the - terminals.
4. Tighten the power cables in the Quanser Q1-cRIO
module power connector terminals using the screws.
5. Re-attach the power connector to the Quanser
Q1-cRIO module.
Note: Make sure the red cable connects to the
+ terminal and the black connects to the - terminal
on each Quanser Q1-cRIO module.
Connect your power supply as instructed in its user manual to turn it ON and power up the NI
CompactRIO controller. When rst powered the Power and Status LEDs should both be turned
on. Then the Status LED should either turn o or blink repeatedly once every few seconds.
V1
C
V2
C