Quantum5x QR-2000 User manual

30 ADELAIDE STREET NORTH SUITE 12
LONDON ONTARIO CANADA N6B 3N5
WWW.QUANTUM5X.COM INFO@QUANTUM5X.COM
PH: 519-675-6999 FAX: 519-667-2162
QR-2000
OPERATING MANUAL
CE
TRUE DIVERSITY RECEIVER
TM
TM

INTRODUCTION
Congratulation and thank you for the purchase of one of these state-of-the-art
PLL Synthesized 1000 channels frequency agile UHF professional wireless systems.
The following table gives an over view of the individual system.
.
11
System Overview
As this is a shared operating manual, please read it thoroughly to familiarize with the
function of each part before use.
QR-2000
No. Of Channel
Frequency Band
Receiving Mode
AC Adapter
Size
UHF
12-15 / 1500 mA
2*1000
2
Casing
Metal
Receiver LCD Color
White in Blue LCD
Models
No. of Receiver
19"
True Diversity
The Volume Control of the receiver is set too high, it may over-drive the input of the
mixer, causing distortion. Conversely, if the receiver output is set too low, the overall
signal to noise ratio of the system may be reduced. Adjust the output level of the receiver
such that highest sound pressure level going into the microphone causes no input
overload in the mixer, and yet permits the mixer level controls to operate in their normal
range (not too high or too low ).
This provides the optimum signal to noise for the entire system.
The functions of USB port
THIS FUNCTION IS NOT OPERATIONAL AT THIS TIME
SCAN function
THIS FUNCTION IS NOT OPERATIONAL
FOR FUTURE USE ONLY
RF Interference
If you encounter receiving interference (from other than an operating TV station), often it
can be overcome by adjusting the receiver's squelch control, as described on below.
Please note that wireless frequencies are shared with other radio services. According to
FCC requlations, wireless microphone operations are unprotected from interference
from other licensed operations in the band. If any interference is received by any
Government or non-Government operation, the wireless microphone must cease
operation. The abovestatement is valid in the U.S.A.
Receiver Squelch setting
The squelch control setting is per LCD display on the front panel of the receiver is preset
at the factory, but can be adjusted if you must use the system in a high RF interference
area. If there is audio output from the receiver when your transmitter is OFF, adjust the
squelch control so the system will receive the signal from your transmitter but squelch
or eliminate the unwanted background RF noise. This adjustment can cause a reduction
in usable range of the wireless transmitter, so set the control to the lowest position which
reliably mutes the unwanted RF signal.
RACK MOUNTING
1. If external antenna is used, low loss RF shielded cable should be used and the length
of the cable
should not exceed 3m.
2. Do not place the receive antenna within 1 m of another receiver or antenna.
3. The receiver antenna should be kept away from any metal surface.
TIPS TO OBTAIN THE BEST RESULTS
FOR A WIRELESS MICROPHONE SYSTEM
REMARKS

QR-2000 RECEIVER
6 6 66 6 6
67 8 9 14 15 16 17
ANT.A
ANT.B
AC INPUT
100V - 240V
DC IN
12V - 15V
BALANCED
AF OUT
MIC LINE
Fig.5
Fig.6
BALANCED
AF OUT
MIC LINE
1. Slot for front mount Antenna
2. Power switch
3. LCD Display
4.
UP button
5. DOWN button
6.
7.
MENU
8.
SET
9.
SCAN
USB port
10. Power switch
11. LCD Display
12.
UP button
13. DOWN button
14.
15.
MENU
16.
SET
17.
SCAN
USB port
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
Slot for front mount Antenna
Antenna B
Mic / Line level Switch
Unbalanced Out
Balanced Out.
DC IN jack
Antenna A.
Mic / Line Switchlevel
Unbalanced Out.
Balanced Out
AC IN jack ( for certain market only )
1211 1213 18
4 5
10
3
27
19 28
20 21 23
22 24 25 26
QR -20 00
Press until
this page appears.
Press button for 2 seconds to enter the mode and the cursor
will flash on only one spot. Use the button to select one of
the 8 preset levels. After making the change, press button for
about 3 seconds will save the changes.
Press until
this page appears.
MENU
SET SET
UP/DOWN
SET
MENU
Press button for 2 seconds to enter the mode. Use the
button to select either or mode
indicates selected. After making the change, press
button for about 3 seconds will save the change.
SET SET
UP/DOWN USER PRESET LEFT
ARROW SET
Press button for 2 seconds to enter the mode and the cursor
will flash. Use the button to select the digit desired. The two
digits at the top right corner is Channel. There are 40 possible channels
to be entered by user. After selected the channel, make the
corresponding change to the frequency. After making all the changes,
press button for about 3 seconds will save the change in Group 25.
SET SET
UP/DOWN
SET
USER EDIT : 01USER EDIT : 01
SQUELCH LEVEL
-95 dBm ( 2 )
SQUELCH LEVEL
-95 dBm ( 2 )
USER MODE
PRESET MODE ö
USER MODE
PRESET MODE ö
To change Squelch level
To go to User Mode

Press Power ON of receiver for 2 seconds and release, the following page
W
roll to next page
ill appear.
After 5 seconds one of the following pages will automatically appear,
Depending
which one was last selected as main page.
Press MENU will
Press MENU will
roll to next page
Press MENU will
roll to next page
Press MENU will
roll to next page
Press MENU will
roll to next page
Press MENU will
roll to next page
Remark : Transmitter is at OFF status.
Q5X
QR-2000
SQUELCH LEVEL
-95 dBm ( 2 )
CF : 01- 01
RF AF
USER MODEUSER MODE
3
To view and roll the various display pages
USER NAME
RF AF
Q5X
QR-2000
801.100MHz
RF AF
CF : 01- 01
RF AF
USER NAME
RF AF
801.100MHz
RF AF
If MENU is not pressed
again,this page will stay
as main page.
If MENU is not pressed
again,this page will stay
as main page.
If MENU is not pressed
again,this page will stay
as main page.
If MENU is not pressed
again,it will automatically
return to one of the
3 main pages.
If MENU is not pressed
again,it will automatically
return to one of the
3 main pages.
If MENU is not pressed
again,it will automatically
return to one of the
3 main pages.
Press
Remark : Brand name and Model number are factory preset. It is NOT user-
changeable.
MENU until
this page appears.
Press until
this page appears.
MENU
Remark : Transmitter is ON, then A or B, RF & AF level indicator will light up.
Press button for 2 seconds to enter the mode and the cursor will
flash. Press again each time will move the cursor one position. Use the
button to select the character or digit. Press again will make
the change and move the cursor one position forward. After finishing all the
changes, press button for about 3 seconds to save the changes.
SET SET
SET
UP/DOWN SET
SET
Press until
this page appears.
Press button for 2 seconds to enter the mode and the following
display will appear and the cursor will flash.
MENU
SET SET
Press again each time will move the cursor one position. The first two
top digits on the left is the Group and the second top two digits to the right
is the Channel. There are all together 25 Groups and 40 Channels (
25*40=1000 ) preset
frequencies to be chosen. Use the button to select the digit.
Press SET again will make the change and move the cursor one position
forward. Once either the Group or the Channel has been altered, the
frequency will be changed automatically. After finishing all the changes,
press button for about 3 seconds will save the changes.
SET
UP/DOWN
SET
4
Q5X
QR-2000
Operating Instructions
A -- USER NAME -- B
RF ---------- AF---------
Making changes to the various displays.
To change User Name
AUSERNAMEBö ÷
A -- 801.100MHZ -- B
RF---------- AF---------
CF:01 - 01
800.000 MHz
To change Frequency
Table of contents