manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Quatreau
  6. •
  7. Control Unit
  8. •
  9. Quatreau QST553 User manual

Quatreau QST553 User manual

This manual suits for next models

1

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

CARTRIDGE REPLACEMENT
110V/60Hz
QT/QST553 Water Heater Control Unit
CS20 Chiller Carbonator
CO2
1
CONTENTS
QUATREAU COLLECTION
CARTRIDGE REPLACEMENT MANUAL
QT/QST553 Water Heater Control Unit
CS20 Chiller Carbonator
TAP FUNCTIONS:
SPARKLING FILTERED WATER
CHANGING THE CO2
CANISTER
When the sparkling water tastes flat, it is
necessary to change the gas canister. The
integral CO2 gas canister is sited on the left-
hand side at
the front of
the unit.
1. To remove a canister,
unscrew in a counter-
clockwise direction.
2. Locate the thread on the
regulator where the gas can-
ister will connect.
3. Carefully present the canister, ensuring the
canister is supported.
4. Rotate the canister in a
clockwise direction, being
careful not to cross-thread the
regulator.
Please follow the instructions below to
ensure your CO2 canister is correctly in-
stalled:
• TAP FUNCTIONS: CHANGING CO2 CANISTER 1
• TAP FUNCTIONS: CHANGING GAC WATER FILTER 2, 3
• CONVERT TO LARGER CO2 BOTTLE 4, 5
CHANGING CO2 CANISTER
5. Rotate until you hear a
hissing sound. This is the gas
being released from the
canister. It is important to
keep screwing until you can
no longer hear this hissing.
6. When the canister
cannot be turned fur-
ther, it is safely con-
nected. Do not turn
the canister any fur-
ther, as this will dam-
age the regulator.
7. Press the glass icon button and runoff an
amount of sparkling water to re-calibrate the
system.
8. It may be necessary to readjust the pressure
regulator located above the CO2 canister to
get the appropriate CO2 mix in your water.
CO2
2 3
The filter should be changed at least once
a year or if the taste or smell of chlorine is
evident. The GAC
filter is located
in front of the
water heater on
the right side. It is
inside the stain-
less steel canis-
ter. Please follow
these instruc-
tions to ensure
the GAC filter is
installed correctly.
3. Turn off the power supply to the water heater
by either unplugging the water heater or
using the toggle switch located on the back
of the water heater.
1. Turn off the cold water supply to the water
heater.
5. Unscrew the canister in a counter-clock-
wise direction until it is clear of its threads.
6. At this point, you can access the filter. Un-
screw the filter in a counter-clockwise direc-
tion. You can now remove both the stainless-
steel filter housing and GAC filter from the
water heater.
2. Relieve pressure in the system by touching
the chilled water icon TouchTap™ or button
SmartTap™ and wait until the water stops
coming out of the faucet.
4. You may want to
put a towel under
the stainless steel
canister that holds
the GAC filter to
prevent water from
spilling on the floor
of the cabinet.
TAP FUNCTIONS:
GAC WATER FILTER
CHANGING PROCEDURE:
CHANGING GAC WATER FILTER CHANGING GAC WATER FILTER
8. Reinstall the filter housing, being very care-
ful not to lose or damage the O-Ring in the fil-
ter housing. If the O-Ring is damaged, replace
it before reinstalling.
10. At this point, you are ready to turn the wa-
ter back on. Turn the cold water on and touch
the chilled water icon (QT) or button (QST).
Let the water run for sixty (60) seconds to
expel any air in the system.
7. Remove the old filter and replace the new
filter in the canister. Position both stainless-
steel filter housing and filter so that you can
screw the filter into its manifold.
9. You can now turn the power on to the wa-
ter heater, and your system is ready to be
used.
4 5
1. Unscrew the CO2 canister that comes with
your Quatreau system.
3. Replace the barb fitting on the new pres-
sure regulator (A) with the male adapter fit-
ting you purchased.
4. Remove the 1/4” tubing from the connec-
tion on the water heater marked CO2 out
and connect it to the new pressure regulator
1/4” male adapter (C) you previously installed
on the regulator.
2. Connect the new regulator to the new CO2
tank (B).
A. Pressure regulator
B. CO2 bottle
C. Male adapter 3/8” NPT x 1/4” push fitting
MATERIALS NEEDED TO CONVERT
THE CO2 BOTTLE TO A LARGER
CO2 SUPPLY
CO2 BOTTLE CONVERT TO
LARGER CO2 SUPPLY PROCEDURE:
11. Check for leaks around the canister to en-
sure it is dry.
12. You may have to wait 10 minutes for the
water heater to come up to temperature be-
fore getting hot water.
5. You are now ready to adjust the CO2 to
get proper water to CO2 mixture.
6. You can now adjust the new CO2 Larger
bottle using the new CO2 regulator to get
proper carbonation in your drinking water.
CONVERT CO2 BOTTLE CONVERT CO2 BOTTLE
Distributed by: Global Water Solutions
QT-QST-QSTD553/CS20 - 06022021 © gws June 2021
Find out more at: www.Quatreau.com