QUBE LIGHTING BEAM 7R User manual

230W BEAM English

2
Thank you for using our products, is safe and effective use of this product to you, before you use this
product, please read this instruction manual carefully complete. This manual contains: the perfor-
mance of the product is and how to safely install, and use of important information, please properly
keep, in order to use as a reference. When installing and using relevant instructions must be strictly
observed.
Beam 7R 230W light Beam, the new revolution of headlamp! Lighter... The total quality is only
17KG! Faster... The X/Y axis moves faster, smoother and less noisy! The software band corrects
positioning function, makes up the hardware error, the positioning accuracy is quite high! Complete-
ly solve X/Y position! Brighter... 3 in combination with optical lens, the color temperature reaches
8500K, which is higher than 700W, 1500W beam light and higher color temperature! Lower... Light
bulb power only 200W, total power only 290W low power! Stronger... The beam feels stronger, the
parallel light is sharper! Intelligent light bulb switch control to extend bulb life! More... More powerful,
more powerful, 16CH / 20CH channel: 14 colors, 17 designs, rotating 8 prisms, atomization, strobe!
Power supply: AC100V - 240V
Frequency: 50hz - 60hz
Total power: 290W
Fuse: 5A
Ballast: Electronic Ballast
Light source: OSRAM (7R) light bulb
Light bulb power: 230W
Color temperature: 8500 k
Average life span: 2000H (light bulb and reective cup overall package
light efciency and higher service life)
Control signal: International standard DMX512
Appearance: High temperature resistant plastic
Light body color: black
Protection level: IP20
Weight: 17kg
Operation parameters:
Product description:

The lamps and lanterns use DMX512 signal control model, the control signal of lamps and lanterns
is a parallel relationship, the connection is more than one signal lamps and lanterns, it is best to use
double core shielded cables. Connection, all through the lamps and lanterns of lamps and lanterns
DMX signal on jack (context) INPUT (INPUT) and OUTPUT (OUTPUT) are connected, connect the
line of lamps and lanterns 3 core XLRXL plug terminal must correspond to each other, when the con-
nection signal lamps and lanterns, it is recommended to use DMX signal terminal. Can be avoided,
due to electrical noise damage control signal, DMX signal terminal device is a XLR plugs connection
between 2 and 3 feet a 120 ohm resistance of 1 w, and connect it on the last stage of lamps and
lanterns of the OUTPUT (OUTPUT) jack.
1. The international standard control signal: DMX512
2. The number of channels: 16Ch
3. The number of motor: a total of 10 mute motor
4. The X axis rotate for 540°, the Y axis vertical rotation of 270°, with automatic correction
5. The dimming: 0-100% linear adjustment
6. Stroboscopic: Double chip stroboscopic (0.5-9 times/SEC), completely linear dimming and
variable stroboscopic speed
7. Color wheel: With 14 kinds of color + blank (can create sharp air beam effect)
8. Pattern wheel: With a 17 xed pattern piece + blank (lets you quickly change the beam shape)
9. A prism: Rotating eight prism, can be bi-directional rotation, rotation speed is adjustable, making
a richer pattern projection effect
10. Itemization: Soft light effect, the design of soft dream effect
11. Focus: adopting the combination of three groups of optical lens effect is much better than the
beam of light, usually can reects the pattern of hid
12. The beam Angle: Parallel beam Angle 0° - 3.8°
13. Overheating intelligent protection
14. Smart bulb switch control, prolong the service life of the bulb
Function Description:
Connection of DMX512 signal:

4
The starting address code of the current light xture is equal to (the initial address code of the last
light xture) + (the number of channels of the lamp) :
1. The initial address code of the rst lamp is A001.
2. The basic channel number of the controller should be greater than or equal to the total number of
use channels.
3. When using any controller, each lamp should have its own initial address code. If the initial ad-
dress code of the rst light lamp is set A001, the number of the luminaire number is 16CH; The
starting address of the second light xture is set to A017. The starting address code of the third light
xture is set to A033; And so on and so forth, (this setting also needs to be determined by different
control tables)
This luminaire can be placed horizontally, slanting and hanging upside down, and must pay attention
to the installation method when hanging and hanging upside down.
Fixed installation of lamps and lanterns: before the positioning of lamps and lanterns, to ensure the
stability of the installation site, when the reverse hanging installation, must ensure that the lamps
and lanterns is not tumbled down on the supporting frame and handle with a safety rope through the
racks and lamps and lanterns, assist hanging; In order to ensure safety. To prevent fall and slide of
lamps and lanterns, lamps and lanterns in the installation and debugging, the ban pedestrians pass,
regularly check whether the safety rope appear wear away, whether hook screws loosen, if because
hanging installation is not stable, lead to fall all consequences arising from the lamps and lanterns
manufacturer does not assume any responsibility.
1. When replacing the bulb, remove the plastic shell of the lamphead rst.
2. Good quality light bulbs are recommended.
3. Uncharged installation, remove the bulb.
4. Hand untouchable parts of the bulb.
5. Tighten the screws after replacing the bulb.
6. The light bulb work at high temperature, and gas discharge can not continue to supply the physi-
cal characteristics of bubble, must therefore be in every time, when the power is completely cooling
ability to operate in about 10 minutes, otherwise it will lead to high voltage discharge, short circuit
burn out components on the computer console.
The initial address code calculation method of lamps and lanterns:
The initial address code calculation method of lamps and lanterns:
Light bulb installation:

5
1. Non-professional personnel, do not remove the ttings in lamps and lanterns without permission.
2. AC power supply: check whether the local power supply meets the rated voltage requirement.
3. The lamps and lanterns is according to the type of electric shock protection design, lamps and
lanterns should be used with sufcient power supply system grounding, and lamps and lanterns of
the ground wire must be connected to the ground of the power supply system. Do not use insulation
damaged power cord, at the same time, do not use the power cord overlap on the other wire.
4. When the installation location and lamps and lanterns, any point on the surface of lamps and
lanterns and any easy to burn the explosive keep minimum distance of 10 meters, 2.5 meters from
irradiation distance, please do not install the lamps and lanterns is directly in to burn the material
surface.
5. Ambient temperature used in luminaires: (-10 degrees + 40 degrees), the maximum temperature
of the lamp surface is 80 degrees, and the lamps and lanterns should be kept away from the liquid
material and wet environment.
6. Make sure the lamps are well grounded before using the lamps, and do not install and remove
any parts.
7. When installing lamps and lanterns, the xing screws must be fastened, equipped with safety
cables and checked regularly.
8. The continuous working time of the luminaires should not exceed 10 hours, and the interval time
of continuous start of the lamps shall not be less than 10. Otherwise, the bulb should be protected
from overheating and cannot be triggered normally.
9. In the process of use, the lamp should be stopped using lamps in time.
10. When the bulb reaches the rated service life, it should be replaced in time, or there will be a
dangerous explosion.
11. The rotating part of the lamp and the pasting accessories must be checked regularly and loos-
ened, and the shaking should be strengthened in time to prevent accidents.
12. Lamps and lanterns uses strong wind cooling and accumulates dirt easily. Must be cleaned once
a month especially the cooling tuyere otherwise will be in a dust jam, lead to bad heat dissipation.
Safety tips!
To ensure your safe use of lamps, read the following safety tips carefully before
using them to avoid unnecessary breakdowns and injuries.

6
One. Light bulbs
1.1. Due to improper operation, the bulb has not been completely cooled. The lamp should be
cooled for more than 10 minutes, so that the inner bulb of the bulb can be fully restored to normal
state, and the power supply can be started again.
1.2. Check whether the bulb has reached the service life and should replace the new bulb.
1.3. Check whether the bulb and the bubble line are leaking, shedding or not having good contact.
1.4. Replace the new point bubbler.
Two. The beam appears dim
2.1. Check whether the bulb has reached the service life and should replace the new bulb.
2.2. Check that the optical parts or light bulbs are clean, and the light bulbs and other optical devices
are accumulated with dust, and the light bulbs and components should be cleaned and maintained
regularly.
Three. The projected image is blurred
3.1. Check whether the electron focus channel value is suitable for the current projection distance.
Four. Computer lights work intermittently
4.1. Check whether the fan is running normally to make it dirty.
4.2. Check whether the internal temperature control switch is closed.
4.3. Check whether the bulb has reached the service life and should replace the new bulb.
Five. Although it glows, the computer lamp no longer accepts controller control
5.1. Check the initial address code and check the connection of the communication line (1 ground
2 minus 3 positive)
5.2. Add signal amplier
5.3. When the bulb was not completely cooled, there was an abnormal start operation, and the in-
stantaneous ultra-high voltage of the bubbler was leaking and the CPU of the circuit board channel
chip was burned.
Six. Computer light cannot be started
6.1. Check whether the insurance on the power input socket is fused
6.2. Lamps and lanterns are not in contact with the line due to vibration during long distance trans-
portation
6.3. Check the input power, computer board and other connector devices
Difcult method:
The following is a list of troubleshooting and processing methods.
Other maintenance tasks are handled by professional maintenance personne

7. After self-examination, some functions do not accept controller control
7.1. Check that the function has no power at work, or whether the chip is burned by other high pres-
sure shocks.
8. The X and Y axis in the other data have been restored to 0 in the other data,
and abnormal noises have occurred
8.1. At the time of abnormal qi, the high point bubble voltage leakage caused the burning of X and
Y axis photoelectric induction circuit board (light lotus root).
8.2. Restart the computer light according to normal procedures
8.3. Push all the channel values of the controller to 0, remote reset computer lamp.
Maintenance and insurance:
Shutdown operation: before each off, the bulb rst closed 10 minutes ahead of time. Let the cooling
fan inside heat when using the lamps and lanterns, fast discharge, it can prolong the lamps and lan-
terns of accessories, especially the service life of the bulb! In order to ensure the lamps and lanterns
can steadily run, should keep it clean, open lamps and lanterns for repair or before maintenance
work that make sure the power is disconnected, it is important to keep the lamps and lanterns is
clean, clean, clean, please regularly not only keep the maximum brightness output, but also can pro-
long the service life of lamps and lanterns, it is recommended to use high quality glass cleaner and
use a clean soft cloth to clean, use the vacuum cleaner at least half an year is clean inside the lamp.
After-sales service
Attention! When the lamps and lanterns are out of the factory, they are strictly inspected and the
packing is in good condition. Please follow the instructions.
The fault of the machine is not covered by the machine.
1. The company will provide technical advice to customers throughout the lifetime.
2. If the product failure, need to repair, please show me your product warranty card, and ll in related
content. At the same time also hope to customers in a timely manner the problems in the products
back to us, convenient for our rst time to improve the product.
3. Besides the luminaires, the following accessories can also be selected:
Attachment: power line: 1, signal line: 1, instruction: 1 copy
The choose and buy a
Light bulb (customer request)
Light hook safety cable (customer selection)

8
Software features:
1. LCD 650,000 color touch TFT interface, easy to operate and beautiful interface.
2. Physical buttons and touch are both completely independent and can be used in
combination
3. Complete all operations independently with the physical keys
4. Complete all operations independently with touch
5. Use the physical buttons and touch mode to complete all operations
6. Intelligent height
7. For example: check all, the decoupling error in the reset, and give hints.
8. Reset calibration (zero calibration)
9. X axis, Y axis, color wheel, pattern disk
1. Display instructions:
Main interface specication
The knob of the display is used as a selection key. Rotate the buttons left and right to
change the selected function. Press to indicate OK
How to check the lamp time
Press the menu mark (as the frist picture)
OTHER INDORM--LAMP TIME--check the time
2.How to reset the lamp
Press the reset mark(as the second picture)--ADV--USE MANG-- PASSWAORD1 :3
PASSWAORD2 :4---KEY--nd RST LAMP -- TRUN IT ON--SAVE--ESC

9
3. How to make change for the language
4. How to change the run model
Press button as the rst picture,then you can see run mode, there have three modes
to show different effects. Such as AUTO, WIRE,DMX, choose the mode you want
here,and remermber press save.
5. How to make color /gobo/ xy/calibration
Press this button
Press button as the frist picture--ADV--Zero Set--- PASS-
WORD 1---Key--Then you can change what you want to
change

6.How to make reset on the display
7.How to set sound mode
Press button as the frist picture--TEST RUN--SOUND
8. How to check beam info
Press button as the frist picture--OTHER INFO
Press button as the rst
picture--RESET

11
9.How to make lamp reset
Press button as the rst
picture--RESET
Press button as the frist picture--RESET
Options Instructions
The operation mode
Channel model
X inversion
Y inversion
No DMX signal
The screen saver
17-20 channel is invalid
Guan/open
Guan/open
17-20 channel control speed (see channel table)
Do not use the encoder (light coupling) correct position
According to the original state continues to run
Close the backlit idle for 30 seconds
The motor return, stop running
Using encoder (light coupling) judging out-of-step and automat-
ically correct position
DMX address
XY
The encoder
1-512
16
Guan
keep
reset
open
20
op
DMX From the machine status: receiving DMX signal from the controller
or host
Voice
control
Receiving external sound or vibration, run the built-in application ef-
fect
Press “OK” button to enter edit state. At this point is selected to one
hundred, according to the “up” “down”
Key change address code. Press the “OK” button once again and
selected 10 editing. Press again
“OK” button to select bits editor. Then exit the editor state at a time.
Automatic Host: run automatically, and send the DMXD signal from machine
3.2. Set the interface

12
guan Back lit yongliang
Reset
Open/guan
0-255
0-255
ₒ ₒ ₒ ₒ ₒ ₒ ₒ ₒ ₒ ₒ
0-255
The light bulb control
The color wheel
Pattern plate speed
Press “ok” button to enter edit state. At this point is selected,
click on “next” button to change channels values, press the “ok”
button once again and exit the editor.
Click “ok” button after see conrmation dialog, press the “ok” key once
again, after carry into the interface, reset all motor
Options Instructions
open When start the lamps and lanterns, lamp light up automatically
Options Instructions
Software version The current software version
A total of time Cumulative time (accurate to minutes)
The use of time The use of this boot since time (down to minute)
Total light soaking time Total light bubble time (accurate to minutes)
The light soaking time The light of this boot since bubble time (down to minute)
DMX channel value In the condition of DMX, showing all channels of value (number), thus the child
into the interface, display as a percentage value and channel value for viewing
System error record
System error record If red ERR lights shine, then failed to reset run out of step, can enter child inter
face for details. After the view can press “ok” the error record to empty
guan Start the lamps and lanterns, the bulb is not bright
no
Switch on light bubble
3.3. Information interface
Restore the default Settings yes Press “ok” is to restore the default Settings
3.4.Manual control interface
This interface is used to control the current lamps and lanterns, neither belongs to the state
machine from machine shape (not receiving DMX signal) also does not belong to the host shape
(not send DMX signal)
3.5. Advanced interface
To enter the show advanced interface, please enter the password: XXXXXX. Specic operation
process: press the up and down key to choose Numbers (a *) at a time. Password input after fully,
nally press the “ok” key password authentication.

3.6. Thou hast interface
Click button, the interface inversion can be 180 degree show.
3.7. English interface
Click button, the interface, switch to English mode.
3.8. Chinese interface
Click button, the interface, switch to the Chinese model.
3.9. The factory interface
Enter the factory interface, display, please enter the password: XXXXXX. Specic operation pro-
cess: press the up and down key to choose Numbers (a *) at a time. Password input after fully,
nally press the “OK” (OK) key password authentication
The biggest bright time
Encryption scheme
Encryption parameters
(frequency/time)
The number of Can be set up the use of lamps and lanterns
Can install the use time of lamps and lanterns
After the encryption mode to open the work. Can be
set up the use of lamps and lanterns (number/time)
Time
0-9999
0-9999
guan
Can be set up on time
Options Instructions

14
Channel Function Channel
values
Channel control instructions (full version):
0-4 Color 1
5-9 color 1+ color 2
10-14 color 2
15-19 Color 2+ Color 3
20-24 Color 3
25-29 color 3+ color 4
30-34 Color 4
35-39 Colors 4+ Colors 5
40-44 Color 5
45-49 Color 5+ Color 6
50-54 Color 6
0-2551 color tray
Options
Channel Settings
Bright time reset NO / YES
Screen saver mode
Can be set up channel switch
Pattern 1 According to address code
Pattern 2 According to factory LOGO
Pattern 3 No display (reserve)
0-255
0-255
0-255
0-255
0-255
0-255
0-255
0-255
X calibration
Y calibration
The dimming calibration
Color wheel alignment
Pattern plate of the calibration
Focusing calibration
Prism calibration
Fog lens calibration
Reset the
calibration
(ne)
Instructions

15
55-59 color 6+ color 7
60-64 Color 7
65-69 Color 7+ Color 8
70-74 Color 8
75-79 Color 8+ Color 9
80-84 Color 9
85-89 Color 9+ Color 10
90-94 Color 10
95-99 Color 10+ Color 11
100-104 Color 11
105-109 Color 11+ Color 12
110-114 Color 12
115-119 Color 12+ Color 13
120-124 Color 13
125-129 Color 13+ Color 14
130-134 Color 14
135-139 Color 14+ Color 15
140-144 Color 15
145-149 Color 15+ Color 1
150-199 Color is running water (from slow to fast)
200-255 color reverse ow (from slow to fast)
0-5 Closed light
6-11 Optics
12-107 stroboscopic mode 1(from slow to fast)
108-149 stroboscopic mode 2(from slow to fast)
150-191 stroboscopic mode 3(from slow to fast)
192-251 stroboscopic mode 4(from slow to fast)
252-255 light
0-19 Closed light
20-255 dimming (0-100%)
0-53 Change of pattern
54-69 pattern forward running water (from slow to
fast)
70-85 pattern reverse ow
86-95, Pattern 1 vibrates (from slow to fast)
96-105, Pattern 2 vibrates (from slow to fast)
106-115, pattern 3 vibrates (from slow to fast)
116-125, pattern 4 vibrates (from slow to fast)
126-135, pattern 5 vibrates (from slow to fast)
136-145, Pattern 6 vibrates (from slow to fast)
Pattern 7 vibrates (from slow to fast)
156-165, pattern 8 vibrates (from slow to fast)
166-175, Pattern 9 vibrates (from slow to fast)
176-185, pattern 10 vibrates (from slow to fast)
186-195, pattern 11 vibrates (from slow to fast)
196-205, pattern 12 vibrates (from slow to fast)
206-215, pattern 13 vibrates (from slow to fast)
Dimmer
Pattern
plates
Frequency
ash
0-255
0-255
2
3
4

16
216-225, pattern 14 vibrates (from slow to fast)
226-235, pattern 15 vibrates (from slow to fast)
236-245, pattern 16 vibrates (from slow to fast)
246-255, pattern 17 vibrates (from slow to fast)
Index
forward running water
Reverse ow (from slow to fast)
To turn (from slow to fast).
0-99 no action
100-105 Close the bulb
106-199 No effect
200-205 Light bulb
206-255 No effect
Prism 0-127
128-255
No prism
Prism
No prism
Prism
000-064
065-127
128-191
192-255
5
6
7
8
9
10
11
12
13
14
15
16
Prism
rotation
Atomization 0-255 Soft Light Atomizing Effect
Pattern clarity from far to near
Level 540 scan
Level 1.2 ne tuning
Vertical 270 scan
Vertical 1.2 ne tuning
X/Y axis speed
0-249 No action
Reset 250-255 lamps
Focus 0-255
X axis 0-255
Y axis 0-255
X axis ne
tuning
0-255
Y axis ne
tuning
0-255
X/Y axis
speed 0-255
Reset 0-255
Electron
bubble
Customize
patterns
0-255
Color tray
Frequency ash
Dimmer
Solid plot
Prism
Prism autobiography
Atomization
Colorful
Focus
X axis
Prism 2 0-127
128-255

X axis ne tuning
Y axis
Y axis ne tuning
XY speed
Macro functions
Customize
patterns
Streamlined
model Color
Strobe
Color tray
Frequency
ash
DimmerDimmer
Solid plot
Flow Forward 150-203 Flow Forward
0-103/104-107/108-207/208-212/213
251/252-255
0-4/5-9/10-14/15-19/20-24/25-29/30-34/35-
39/40-44/45-49/50-54/55-59/60-64/65-
69/70-74/75-79/80-84/85-89
0-4/5-9/10-14/15-19/20-24/25-29/30
34/35-39/40-44/45-49/50-54/55-59/60
64/65-69/70-74/75-79/80-84/85-89/90
94/95-99/100-104/105-109/110-114
115-119/120-124/125-129/130-134
135-139/140-144/145-149
Color tray
Frequency ash
Channel Control Note (Streamlined Mode):

18
et Blister/reset (220~255)
9
Dithering
0-127
(bubble 50~70 bright 100~150 reset)
Flow Forward 175-214 Flow Reverse
215-255
Prism
Prism
auto biography
Prism
PrismRot
Frost
Rainbow
Focus
Pan
Tilt
PT Speed
Macro
Lamp/Reset
Atomization
Colorful
XY
speed
Macro
functions
Focus
X axis
Y axis
Bliste
0-128/129-191/192-255
0-128/129-255
0-128/129-255
0-5/6-16/17-32/33-48/49-64/65-80/81
96/97-112/113-128/129-144/145-160/161
176/177-192/193-208/209-224/225-255

19
www.qube-lighting.com
THANK YOU FOR CHOSING QUBE-LIGHTING
FOR MORE INFORMATION PLEASE
Popular Light Fixture manuals by other brands

STUDIODUE
STUDIODUE SLIMBAR SB PILOT 1615 user manual

FormaLighting
FormaLighting MOTO-ZERO COMPASSO ZOOM 40 Installation instruction

SilverStar
SilverStar Motor-Pro(RGY) Laser user manual

Heath Zenith
Heath Zenith SL-5718-BK-C - Heath - 270-Degree Motion Sensing Security... user guide

AL Tech
AL Tech AE-L-SBAS-150 instructions

superbrightleds
superbrightleds STN-1-TW user manual

Etec
Etec Moving Beam 7Q user manual

Show Tec
Show Tec Infinity iW-1915 RGBW Wash manual

Falconeyes
Falconeyes LPS-1000CTR instruction manual

IMG STAGE LINE
IMG STAGE LINE TWIST-5LED instruction manual

ARTFOX Lighting
ARTFOX Lighting LED Beam Wash 19E user manual

Lightmybricks
Lightmybricks LEGO R2-D2 75308 installation guide