SLOT4 Service slot4, supports 3G/HD/SD-SDI
SLOT5 Service slot5, supports 3G/HD/SD-SDI, GE,
AUX
ote: if AUX interface is selected,
both SLOT5 and SLOT6 must be
AUX interface
SLOT6 Service slot6, supports 3G/HD/SD-SDI, GE,
AUX
SLOT7 Service slot7, supports 3G/HD/SD-SDI, GE,
AUX
ote: if AUX interface is selected,
both SLOT7 and SLOT8 must be
AUX interface
SLOT8 Service slot8, supports 3G/HD/SD-SDI, GE,
AUX
Table 2-2-2 Interfaces on Rear Panel
Name Descripti n
OPT Common optical interface, bi-directional, FC/SC/ST-PC can be selected.
λ1-λ2 Optional cascade optical interfaces, λ1-λ2 are wavelength division multiplexed into the
common optical interface. The wavelength should be descript in the order item. The λ1
will be the shorter wavelength and the λ2 will be the longer wavelength.
SDI I 3G/HD/SD-SDI input.
SDI LOOP Optional 3G/HD/SD-SDI loop out.
SDI OUT1 3G/HD/SD-SDI output1.
SDI OUT2 Optional 3G/HD/SD-SDI output2.
ETH
10/100/1000M
Gigabit Ethernet
AUX1/AUX2 Auxiliary service interfaces. every five terminals are used as a group and the service
type can be configured for every group independently including audio, RS232,
RS422, RS485 and contact closure. See for details.
Power Support 220VAC/110VAC,48VDC or 24V DC power supply. Any two of them can be
selected and installed.
~220V AC ~220V AC power input. 100VAC~240VAC
-48V DC PG D Earth ground (connects to the chassis).
G D Ground
-48V 48VDC. 36VDC ~72VDC.
+24V DC PG D Earth ground (connects to the chassis).
G D Ground
+24V 24VDC power. 18VDC~36VDC.
Table 2-2-3 Indicators on Rear Panel