QuietCool IT-36003 User manual

DO NOT THROW AWAY!
OWNER’S GUIDE CONTAINS IMPORTANT INFORMATION.
LEAVE WITH HOMEOWNER
OWNER’S GUIDE
Wireless RF Control Kit
IT-36003
!

1-888-QUIETCOOL2
GENERAL SAFETY INSTRUCTIONS
1. Read Instructions - All safety and operation instructions must be read.
2. Retain Instructions - The safety and operating instructions should be kept for future
reference.
3. Heed Warnings - All warnings should be followed.
4. Follow Instructions - All installation and operating instructions should be followed.
5. Water – The QuietCool system should not be used near water. If you live in a very humid
climate, be sure to cover your damper box with insulation to reduce condensation.
6. Heat - The QuietCool system should be situated away from heat sources.
7. Damage Requiring Service - Only qualied service personnel should service the
QuietCool system. The user should not attempt to service the product.
CONTENTS
1. SYSTEM OVERVIEW..........................................3
1.1 Introduction ............................................3
1.2 Features ...............................................3
1.3 Key Specications .......................................3
2. INSTALLATION ..............................................4
2.1 Installing the Hub........................................4
2.2 Wiring the Hub. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.3 Fan Hub LED Indicators ..................................9
2.4 Pairing the Wall Switch ..................................10
2.5 Finding a Location for the Wall Switch .....................10
2.6 Installing the Wall Switch ................................11
3. OPERATION ...............................................11
3.1 Operating the Wall Switch ...............................11
3.2 Frequently Asked Questions .............................12
RF WIRELESS CONTROL WARRANTY............................14
INCLUDED IN THE BOX
- IT-AC-HUB-01 Control Hub
- IT-RFGLSSWITCH-01 RF Switch
- QuietCool Owner’s Guide
- (2) AAA batteries
- Mounting screws and drywall
anchors
STOP! READ ALL INSTRUCTIONS IN THIS GUIDE BEFORE INSTALLING YOUR
QUIETCOOL SYSTEM
Read this guide before proceeding! The manufacturer is NOT responsible for faulty
installation or product damages caused through failure to fully read this guide BEFORE
attempting installation.
QC MANUFACTURING, INC.
26040 YNEZ ROAD
TEMECULA, CA 92591
!!
PHONE
1-888-QUIETCOOL
EMAIL
WEBSITE
www.QuietCoolSystems.com

QUIETCOOLSYSTEMS.COM 3
1. SYSTEM OVERVIEW
1.1 Introduction
Congratulations on the purchase of your new QuietCool RF Wireless Control!
The QuietCool Whole House Fan RF Wireless Control is the simplest way to control your
QuietCool Advanced Whole House Fan from anywhere in your home!
The QuietCool RF Wireless Control allows users to set the length of time that the fan will run
and set the desired speed level.
1.2 Features
• Control your QuietCool from anywhere in your home
• Set countdown time for each QuietCool in your home (up to 12 hours)
• Adjust speed setting for each multi-speed QuietCool
• Pair up to 20 switches to each Hub
• Surface mount wall switch that can be removed and used from anywhere in the home
1.3 KeySpecications
IT-RFGLSSWITCH-01 (Switch):
Voltage: 3VDC (2 AAA batteries)
Battery Standby Current: ≤10uA
RF working distance: 100ft (no obstructions)
IT-AC-HUB-01 (Hub)
Voltage: 120V
Frequency: 60Hz
Motor load: 1HP, 735W (Max)
UL Rated Operating Temp 14°F - 149°F
The listing of this product allows it to be installed in conned spaces with temperatures that exceed 120 degrees.

1-888-QUIETCOOL4
2. INSTALLATION
2.1 Installing the Hub
IMPORTANT: If you are installing the Hub onto an existing QuietCool fan, be sure to
shut off the power before attempting installation. If you are installing the Hub onto a
new fan, perform all installation steps before plugging in the fan.
Install the Hub directly to the motorhead:
1. Remove the handy box cover on your QuietCool fan. Remove the wire nuts from the
power cord and motor wires inside the handy box. Remove the ground screw.
2. Remove the power cord bushing and power cord. Keep both the bushing and power
cord as you will be using it for the installation of the hub.
3. Remove the four screws that are used to mount the handy box to the QuietCool
motorhead. Retain the four screws as you will be using them to attach the Hub to the
QuietCool motorhead.
4. Using your philips screwdriver, open up the Hub and install the powercord bushing
through the hole at the back of the hub.
5. Run the motor wire leads through the large knockout in the bottom of the hub.
6. Using the four screws from the handybox, mount the Hub to your QuietCool
motorhead.
2.2 Wiring the Hub
NOTE: Wiring Diagrams are for examples only. Wiring should be done by a licensed
electrician following local building and electrical codes and/or NEC guidelines. 12 or
14-gauge romex is common. Check your local building code before choosing the wire
type.
NOTE: Ensure the power is disconnected before performing any wiring connections.
NOTE: The wiring diagrams and instructions are shown using the power cord included
with your QuietCool. The installation can also be performed with 2-wire romex and
hard wired.
NOTE:IfyouareretrottingtheRFControl,youwillhavetoun-wiretheexistingwall
switch. You will reuse the power that was run to the switch to go directly into the RF
Control Hub.
Single Speed Wiring (for all 1500/1.5 models) (see Figure A)
1. Using a wire nut, connect the black wire from the power cord to the black wire
from the Hub.
!!
Installation Video:
Watch the video by scanning the
QR code or visit
www.QuietCoolSystems.com/support
!!
!!
!!
!!

QUIETCOOLSYSTEMS.COM 5
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub. Cap the yellow and red wires from the Hub.
3. FOR TRIDENT AND CLASSIC MODELS: Connect the red wire from the fan to the
blue wire on the Hub
FOR STEALTH AND ENERGY SAVER MODELS: Connect the black wire from the
fan to the blue wire on the Hub
4. Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
5. Set the dip switch positions inside the Hub as shown in the diagram below.
6. Power-on the Hub. The Power LED indicator will be lit.
7. Press the Test button to make sure the fan works. The Test LED indicator will blink
once every two seconds indicating 1-speed and the fan will be on. Press the Test
button again and the fan should shut off and the LED will be off. If the fan doesn’t
operate as described in step 6, please check the dip switch postion.
Two Speed Wiring (for CL-2250 to 7000 and TRI PRO-2.5 to 7.0) (see Figure B)
1. Using a wire nut, connect the black wire from the power cord to the black wire
from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the black wire from the fan to the blue wire on the Hub. Connect the red
wire from the fan to the red wire on the Hub. Cap the yellow wire from the Hub.
4. Ground the green wire from the fan and the green wire from the power cord to
the ground screw in the Hub.
Power
Cord
Attach green ground wires to ground screw
All White Common Wires Together
POWER TIMER PAIRTEST
Set dip switches:
1 - ON
2 - OFF
3 - OFF
ON
1 2 3
Whole House Fan
Figure A

1-888-QUIETCOOL6
5. Set the dip switch positions inside the Hub as shown in the diagram below.
6. Power-on the Hub. The Power LED indicator will be lit.
7. Press the Test button to make sure the fan works. The Test LED indicator will blink
twice every two seconds indicating 2-speed and the fan will be on high. Press the
Test button again and the fan will switch to low speed. Press the Test button again
and the fan should shut off and the LED will be off.
8. If the fan doesn’t operate as described in step 8, please check the dip switch
postion.
Two Speed Wiring (for ES-2250 and STL PRO-2.5) (see Figure C)
1. Using a wire nut, connect the black wire from the power cord and the black wire
from the fan to the black wire from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the red wire from the fan to the red wire on the Hub. Connect the yellow
wire from the fan to the blue wire on the Hub. Cap the yellow wire from the Hub.
4. Ground the green wire from the fan and the green wire from the power cord to the
ground screw in the Hub.
5. Set the dip switch positions inside the Hub as shown in the diagram.
6. Power-on the Hub. The Power LED indicator will be lit.
7. Press the Test button to make sure the fan works. The Test LED indicator will blink
twice every two seconds indicating 2-speed and the fan will be on high. Press the
Test button again and the fan will switch to low speed. Press the Test button again
and the fan should shut off and the LED will be off.
8. If the fan doesn’t operate as described in step 7, please check the dip switch
postion.
Power
Cord
Attach green ground wires to ground screw
All White Common Wires Together
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Whole House Fan
ON
1 2 3
Figure B

QUIETCOOLSYSTEMS.COM 7
Two Speed Wiring (for ES-3100, 4700, 5400, 6000, 7000, and STL PRO-3.3) (see Figure D)
1. Using a wire nut, connect the black wire from the power cord and the black wire
from the fan to the black wire from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the red wire from the fan to the red wire on the Hub. Connect the blue
wire from the fan to the blue wire on the Hub. Cap the yellow wire from the Hub.
4. Ground the green wire from the fan and the green wire from the power cord to the
ground screw in the Hub.
5. Set the dip switch positions inside the Hub as shown in the diagram below.
6. Power-on the Hub. The Power LED indicator will be lit.
7. Press the Test button to make sure the fan works. The Test LED indicator will blink
twice every two seconds indicating 2-speed and the fan will be on high. Press the
Test button again and the fan will switch to low speed. Press the Test button again
and the fan should shut off and the LED will be off.
8. If the fan doesn’t operate as described in step 7, please check the dip switch
postion
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Figure C
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - ON
3 - OFF
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Figure D

1-888-QUIETCOOL8
Three Speed Wiring (for STL PRO-4.8, 5.5, 6.0, & 7.0) (see Figure E)
1. Using a wire nut, connect the black wire from the power cord and the black wire
from the fan to the black wire from the Hub.
2. Connect the white wire from the power cord and the white wire on the fan to the
white wire from the Hub.
3. Connect the red wire from the fan to the red wire on the Hub
4. Connect the yellow wire from the fan to the yellow wire on the Hub
5. Connect the blue wire from the fan to the blue wire on the Hub
6. Ground the green wire from the fan and the green wire from the power cord to the
ground screw in the Hub.
7. Set the dip switch positions inside the Hub as shown in the diagram below.
8. Power-on the Hub. The Power LED indicator will be lit.
9. Press the Test button to make sure the fan works. The Test LED indicator will blink
three times every two seconds indicating 3-speed and the fan will be on high.
Press the Test button again and the fan will switch to medium speed. Press the Test
button again and the fan will switch to low speed. Press the Test button again and
the fan should shut off and the LED will be off.
10. If the fan doesn’t operate as described in step 9, please check the dip switch
postion.
Attach green ground wires to ground screw
POWER TIMER PAIRTEST
Set dip switches:
1 - OFF
2 - OFF
3 - ON
Power
Cord
All White Common Wires Together
Whole House Fan
ON
1 2 3
Figure E

QUIETCOOLSYSTEMS.COM 9
2.3 Fan Hub LED Indicators
Power Indicator
• The Power LED indicator will
always be lit when the Hub is
connected to Power.
• If this LED is not lit, check the
power source
Timer Indicator
• The Timer LED indicator will light
up as shown below:
1. 1 Hour: 1 Blink
2. 2 Hours: 2 Blinks
3. 4 Hours: 4 Blinks
4. 8 Hours: 8 Blinks
5. 12 Hours: 12 Blinks
6. Continuous On: Off
Test Indicator
• The Test LED indicator will light up as shown below when the Test button is pressed
and when the fan is turned on via the Wall Switch:
1. One Speed Fan: blink once every 2 seconds
2. Two Speed Fan: blink twice every 2 seconds
3. Three Speed Fan: blink three times every 2 seconds
Pair Indicator
• The Pair LED indicator will light up when making pair operations. Please see page 12
for details on pairing.
Notes on Operation
• If the Dip Switch is not congured correctly, all the indicators on the Hub will stay
solid when the Hub is powered on. Please switch off power and re-congure the Dip
Switch as shown in the wiring diagrams.
POWER TIMER PAIRTEST

1-888-QUIETCOOL10
2.4 Pairing the Wall Switch
1. Remove the mounting plate from the back of the switch and install the included AAA
batteries into the switch by removing the plastic covers. All the LED indicators will
light up indicating that the switch has power. Replace the plastic covers.
3. Press and hold the Pair button on the Hub. The Pair LED indicator will be on for three
seconds then turn off. This clears all previous pairings out of the Hub,
4. Press the Pair button on the Hub twice. The Pair LED indicator will blink once every
second indicating the Hub is in pairing mode.
5. Press any of the buttons on the Wall Switch to wake it up. Now hold one of the
buttons on the switch. The Pair LED indicator on the Hub will go out and the Wall
Switch speed indicators will be blinking indicating successful pairing. Press one of
the Wall Switch buttons again, the speed indicators will go out, and it will display the
current fan status.
6. Press the Timer button to test the Wall Switch to make sure it is communicating with
the Hub.
NOTE: If a button on the Wall Switch is not pressed within three minutes of
pressing the Pair button on the Hub, the LED indicator on the Hub will go out,
indicating unsuccessful pairing. You will need to go back and repeat steps 4 and
5.
2.5 Finding a Location for the Wall Switch
1. It is very important to nd the correct location to install the Wall Switch that will allow
the Wall Switch to communicate with the Hub.
2. Find the location you would like to install the Wall Switch and test that it properly
communicates with the fan to turn the fan on and off.
3. If the fan comes on, this is a good location.
4. If all the LED indicators turn on, the Wall Switch is not communicating with the Hub and you
will need to nd a location closer to the fan.
!!

QUIETCOOLSYSTEMS.COM 11
2.6 Installing the Wall Switch
1. Using your hands, slide the Wall Switch off the
mounting plate.
2. If you have an existing Wall Switch with a junction
box installed, install the mounting plate over
the junction box using the oblong holes on
the mounting plate. Make sure you install the
mounting plate with the arrow facing upwards.
3. If you do not have an existing junction box, simply
install the mounting plate to the drywall. Using the
included drywall anchors and screws, mount the
plate onto the drywall through the four mounting
holes.
3. OPERATION
3.1 Operating the Wall Switch
Timer Button
• The top button on the switch controls the Timer
functionality of the fan.
• This button must be pressed for the fan to turn on.
• Button Presses:
Speed Button
• The bottom button on the switch controls the speed
functionality of the fan.
ON/OFF Button
• The ON/OFF button on the switch turns the fan on or off.
Wall Switch Sleep Mode
• If no button press is detected for 10 seconds, the Wall Switch will enter sleep mode.
Pressing either button will wake the switch and display the current status.
• In Sleep Mode, all LED indicators will be off.
1 2 4 8 12
H
M
L
ON OFF
H M L
1 2 4 8 12
One Press: 1 Hour
Two Presses: 2 Hour
Three Presses: 4 Hours
Four Presses: 8 Hours
Five Presses: 12 Hours
Six Presses: Continuous On
Seven Presses: Off
One Speed Fan
• First press: ON
Two Speed Fan
• First press: HIGH
• Second press: LOW
Three Speed Fan
• First press: HIGH
• Second press: MED
• Third press: Low

1-888-QUIETCOOL12
LED Status Indicators of Wall Switch
• If all LED indicators on the Wall Switch come on after three seconds of pressing one
of the buttons, this means the Wall Switch is failing to connect to the Hub. You will
need to move the switch closer to the Hub to ensure proper communication.
• If all the Timer LED indicators are off and one of the Speed LED indicators are on,
this means you have not set the time for the fan to run and the fan will not operate.
Simply press the Timer button to turn the fan on and set the fan runtime.
• If only one of the Timer LED indicators is on and only one of the Speed LED
indicators is on, the fan is running at the indicated speed and timer level.
• If all the Timer LED indicators are on and only one of the Speed LED indicators are
on, the fan is running in Continuous On mode at the indicated speed level. The fan
will continue to run until you press the Timer button to turn it off.
Notes on Operation
• In order for the fan to run, a Timer selection MUST be made. When the Timer status
is off (no LED indicators lit), you can still change the Speed setting. The Speed
setting will take effect once the Timer selection is made.
3.2 Frequently Asked Questions
What does RF Mean?
“RF” Stands for Radio Frequency.
How does RF Work?
A small electronic device is used to transmit and/or receive radio signals between two
devices. In an embedded system, it often communicates with another device wirelessly.
This wireless communication may be accomplished through optical communication or
through radio frequency (RF) communication.
Will RF Interfere with other devices in my home?
The RF will not interfere with other wireless or RF devices in your house. It produces its
own unique RF signal that can only communicate with our RF Switch.
How many switches can you connect to a single hub?
You can connect up to 20 switches to a single hub.
Will my neighbor be able to control my fan if they have the same set up as me?
They will not because you need to physically activate the pairing process between the RF
Switch and the RF Hub.
What is the range?
The RF Switch and RF Hub have a range restriction of 100ft.

QUIETCOOLSYSTEMS.COM 13
What happens if I lose the RF Switch?
If you lose or damage an RF Switch you will need to purchase another and re-pair the new
one to the RF Hub.
Can you control multiple fans with a single switch?
No. You can only control one RF Hub per switch.
How long do the batteries last?
One year.
Why are all my lights solid on the hub and nothing is working?
If you’re experiencing solid lights on the hub then it is an indication that your DIP switches
are not in the correct position. Disconnect power, adjust your DIP switches, and the only
light that should be lit is your RED power light.
Why is there a medium speed if my fan is only a two speed?
The RF Hub and RF Switch are universal to all QuietCool models. There are some units
that feature three speeds which use the medium on the switch. As long as your DIP switch
is set correctly in the hub, the switch will automatically skip over medium speed.
How do I change the DIP switch to the correct speed of my fan?
You will need to disconnect power, make your adjustment inside the hub, and then
reconnect power.
Can you connect the RF Control to a smart home system like Alexa, Google Home,
or Apple HomeKit?
No, in the current conguration the RF Control cannot connect to a smart home system.
There are systems on the market that take RF signal and translate them to a smart home
system, but they have not been tested and may not work reliably.

1-888-QUIETCOOL14
CONTROLS LIMITED WARRANTY
This warranty is extended to the original purchaser of this model or, if this unit is purchased and requires installation by
a building contractor, to the original owner of the home. No subsequent purchaser of the unit or of a home in which it is
installed is entitled to any of the benets of this warranty. The QuietCool Product that you have purchased has a limited
warranty from the date of purchase against defects in workmanship and materials. Please see attached chart below for
warranty details. If you believe you received a defective product, call our customer service at 1-888-QUIETCOOL. Have proof
of purchase available to validate the warranty. If it’s necessary to send the defective part to QC Manufacturing, Inc., freight is
paid by the customer. If found to be defective following examinations, any defective part will be replaced free of charge and
returned freight prepaid. This warranty does not cover any labor costs, including those required for diagnosis, eld repair
or replacement or removal of any allegedly defective part. The company reserves the right to require and receive proof of
purchase of the date of purchase before undertaking its obligations under this warranty. The right to require and receive
proof of purchase of date of purchase extends to all licensed dealers of QC Manufacturing Inc. products.
Limitations
QC Manufacturing, Inc. shall not be liable for, and this warranty does not apply to, any failure, defect or damage resulting
from or connected with misuse, abuse, neglect or improper handling or staging, or installation not in strict adherence to QC
Manufacturing’s written instructions; unauthorized alteration to factory specs, lack of maintenance, lack of proper ventilation
transportation damage, impact of foreign objects, re, ood, earthquake, lightning, hurricane, hail, tornado or other violent
storms, force majeure or other act of (g)God; or defects in failure of or damage caused by materials used as roong base
over which the product is installed or by movement, distortion, cracking or settling of walls or the foundation of the building.
QC Manufacturing, Inc. reserves the right to discontinue or modify any of its products including, without limitation, color, and
shall not be liable as a result of such discontinuation or modication, nor shall QC Manufacturing, Inc. be liable in the event
replacement material may vary in color in comparison to the original product as a result of normal weathering.
Even if your product was not properly installed according to QC’s published application instructions, this limited warranty
remains in effect if your product fails to perform as a result of a manufacturing defect.
However, QC will NOT compensate you for:
1. Damage from anything other than an inherent manufacturing defect in your product, such as:
• Improper installation of your product, faulty application, or application not in strict accordance
with QC’s published application instructions.
• Improper storage or handling of your product.
2. Damage resulting from mold growth or condensation.
3. Chipping, fading, or peeling paint on your product.
4. Labor costs for removing or replacing your product except as specically provided for above or for any
other roong or building materials.
Limited Warranty Protection
Controls
QC Manufacturing, Inc. extends this warranty coverage to the original purchaser of the following QuietCool products (see
attached for applicable products) for a period of time (varies by product) provided that the product has been installed in
strict accordance with QC Manufacturing, Inc.’s written installation instructions. Under this warranty, QC Manufacturing, Inc.,
at no charge, will repair or replace any product found to be defective during the warranty period as long as proof of purchase
is submitted to QC Manufacturing, Inc. (QC Manufacturing, Inc.’s period begins when the product installation is completed).
QC Manufacturing, Inc.’s maximum liability under this limited warranty will be equal to the reasonable cost to replace the
defective product.
Accessories Model Numbers Warranty
Controls
IT-AF-SMT, IT-AF-SMT-NR, IT-30001, IT-30002,
IT-30003, IT-36002-A, IT-36003, IT-AC-HUB,
IT-RFHUB-01, IT-RFSWITCH-01,
IT-RFGLSSWITCH-01
One (1) Year coverage applies to the models
indicated.

QUIETCOOLSYSTEMS.COM 15
Rev. 6/12/23
CONTROLS LIMITED WARRANTY
Other Conditions
This warranty is the entire agreement between you and QC Manufacturing, Inc., and there are no other oral
or written warranties, liabilities or obligations of QC Manufacturing except apart from those set forth herein.
Pertinent state law shall control for what period of time subsequent to sale a consumer/homeowner may seek a
remedy pursuant to the implied warranty of merchantability or tness for a particular purpose. In no event shall
QC Manufacturing, Inc. be liable for consequential or incidental damages of any kind, including any damage
to the building, its contents or any persons therein, resulting from the breach of any warranty set forth herein,
unless exclusion of these types of damages are specically prohibited by state law. No eld representative of QC
Manufacturing, Inc. or any distributor or dealer is authorized to make any change or modications to this warranty.
How to Start the Warranty Process
To obtain service under this warranty, rst contact your dealer where you purchased the equipment. If you are
unable to nd or reach your dealer, contact Customer Service at QC Manufacturing, Inc. by phone, email or visiting
our website at https://quietcoolsystems.com/support/return-merchandise-authorization/ to start the RMA process.
An RMA (Return Merchandise Authorization) form is required for returns to the factory to ensure your return can
be processed efciently and quickly. There is no informal dispute settling mechanism available in the event of a
controversy involving this warranty
QC Manufacturing, Inc. Customer Service
26040 Ynez Rd.
Temecula, CA 92591
www.QuietCoolSystems.com
951-325-6340
ISED Statement
This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic
Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:
1. This device may not cause interference.
2. This device must accept any interference, including interference that may cause undesired operation of the device.
L’émetteur/récepteur exempt de licence contenu dans le présent appareil est conforme aux CNR d’Innovation, Sciences et
Développement économique Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux
deux conditions suivantes :
1. L’appareil ne doit pas produire de brouillage;
2. L’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en com promettre le
fonctionnement.
!!
FCC Regulations
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
FCC Caution
The user is cautioned that changes or modications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
FCC Notes
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installa-
tion. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
—Reorient or relocate the receiving antenna.
—Increase the separation between the equipment and receiver.
—Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
—Consult the dealer or an experienced radio/TV technician for help.
!!
!!
!!
PHONE
1-888-QUIETCOOL
EMAIL
FCC SUPPLIER’S DECLARATION OF
CONFORMITY
PRODUCT NAME: RF Glass Switch
MODEL NUMBER: IT-RFGLSSWITCH-01
QC MANUFACTURING, INC.
26040 Ynez Road
Temecula, CA 92591
WEBSITE
www.quietcoolsystems.com
!!

1-888-QUIETCOOL | WWW.QUIETCOOLSYSTEMS.COM
Rev. 6/12/23
Table of contents
Other QuietCool Control Unit manuals
Popular Control Unit manuals by other brands

Danfoss
Danfoss PVE 3 Series installation guide

Eaton
Eaton COOPER POWER SERIES manual

XEMEX
XEMEX SUNGATE WatchTalk installation manual

Valon
Valon 5015 Operation manual

Eaton
Eaton CEAG DLS/3PH-BUS-Module-inverse Mounting and operating instructions

PDi
PDi PD196-244R12 Installation and operating instructions