QUNDIS WTX16.GSM User manual

CE1N2878en
10.09.2009
www.qundis.com
Network nodes
with gateway WTX16.GSM
WTX16.IP
WTX16.MOD-1
The WT…16… network nodes are used to receive and handle the data transmitted by
consumption meters of the Q AMR system. They are equipped with a gateway that
can provide data of up to 2,000 meters for remote readout. WTX16.IP can be read via
Ethernet while WTX16.GSM and WTX16.MOD-1 contain a GSM modem. They are read
via the telephone network.
Use
The WT…16… network node is a component of the Q AMR system. It has been designed
for use in buildings to create a radio network for receiving and storing the data transmitted
by the consumption meters installed in the building. Communication between several net-
work nodes is via radio also so that no wiring is required. All measured values acquired by
the consumption meters are continuously exchanged within the network, which means that
every network node stores the current consumption values, the values read out at the end of
the month, and the set day values of all metering devices on the network. Owing to this
operating principle, all network data can be read out at any of the nodes, or a QUNDIS gate-
way for remote data transmission can be used with any of the nodes.

2/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1CE1N2878en 10.09.2009
Functions
Reception and storage of the data transmitted by the consumption meters
Automatic creation of a network with up to 12 WT…16 (with a maximum of 500 consump-
tion meters)
Passing on all relevant consumption values to all WT…16 on the network
Communication via the QUNDIS gateway
Network node versions
The WT…16… network node is a component of the Q AMR system and has been designed
for exclusive use with that system.
The network node with integrated gateway is available in a number of versions for different
applications:
Type code
(ASN) Application Integrated
M-Bus master Max. number of
meters
WTX16.GSM Network node with gateway
remote readout via GSM
yes,
5 additional
unit loads
2000
WTX16.IP Network node with gateway
remote readout via Ethernet
yes,
5 additional
unit loads
2000
WTX16.MOD-1 Network node with gateway
remote readout via GSM or GPRS*)
no 500**)
*) The use of the GPRS application requires certain provisions by the network operator. To
use the GPRS option the user has to conclude a special contract with the service pro-
vider.
**) WTX16.MOD-1 has no M-Bus master. It cannot be used to interconnect different net-
works.
Combinations
All network nodes with gateway can be used in any combination with other QUNDIS network
nodes as long as the maximum number of 12 nodes per network is not exceeded.
Network nodes with gateway and integrated M-Bus master (WTX16.GSM and WTX16.IP)
can read external M-Bus meters complying EN1434/3.

3/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1 10.09.2009
Basic diagram
The WT…16… consists of the following blocks:
transceiver for
Q AMR network
M-Bus
Master
5 unit loads
RS232
*) WTX16.GSM only **) WTX16.IP only
The transmitter and the receiver are used to
collect data from the consumption meters and
to forward theses data to other nodes in the
network the data memory stores the consump-
tion data. It is protected against temporary
mains power failures by the backup battery.
The network nodes WTX16.GSM and
WTX16.IP are equipped with a gateway to
store data of up to 2000 meters and to provide
a possibility for remote readout via GSM or
Ethernet. The gateway has an additional M-
Bus master that can drive up to 5 additional
external M-Bus unit loads (e.g. up to 5 addi-
tional M-Bus meters). Usually, however, the
M-Bus master is used to connect nodes of
different networks to be able to read more
meters using only one gateway.
For extension of M-Bus, is it possible to con-
nect a repeater to the gateway.
The gateway can be programmed using an
additional RS232 interface.
***) user programmable
The network node WTX16.MOD-1 is equipped
with a gateway for remote readout via GSM or
GPRS.
It has no M-Bus master, though. Therefore it
can read data from one network only (max.
500 meters).
WTX16.GSM
WTX16.IP
WTX16.MOD-1

4/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1CE1N2878en 10.09.2009
The WT…16… consists of 2 major sections: The base and the housing with the electronics.
It is thus possible to mount the base prior to commissioning, enabling the electrical installer
to connect the WTX16 to the mains network. At the time of commissioning, the electronics
section is snapped on and the electrical connections are made.
The electronics section is identical for all types of network nodes. It contains control ele-
ments of the network:
RESET
MODE
DISPLAY
1 2 3 4
6
7
11
10
8
9
5
1. Connector for M-bus service connection
2. Connector for RS-232 module
3. Plug terminal for the fixed M-bus connection
4. Connector for power supply DC 3,6 V
5. Connector for backup battery
6. Operating mode button (MODE, red)
7. Button for switching the display (DISPLAY, blue)
8. Reset button (recessed)
9. Display
10. Connector (not for the user)
11. Firmware memory (covered up)
Basic design
Electronics section

5/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1 10.09.2009
The wall-mounted section of WTX16.GSM and WTX16.IP contains these components:
1. Connector for power supply DC 3,6 V
2. Indication of mains supply (red LED)
3. permanently installed cable (no flexible cable!)
4. SIM-card holder (WTX16.GSM only)
5. RS232 interface for servicing
6. Connector for M-bus service connection
7. Screw terminal for the fixed M-bus connection
8. Antenna (WTX16.GSM only)
9. Indication of Gateway status (green LED)
Wall-mounted section
WTX16.GSM/WTX16.IP
Frontal view
Perspective

6/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1CE1N2878en 10.09.2009
The wall-mounted section of WTX16.MOD-1 contains these components:
8
4
13
1
7
6
2
5
1. Connector for power supply DC 3,6 V
2. Indication of mains supply (red LED)
3. permanently installed cable (no flexible cable!)
4. SIM card holder (WTX16.MOD only)
5. RS232 interface for servicing
6. Connector for M-bus service connection
7. Anschluss für M-Bus
8. mains connection L and N
LED- reaction Blinking interval
meaning
WTX16.GSM/ WTX16.IP ≤1sec Gateway is booting
Error
> 1 sec Gateway is ready for use
≤1sec Gateway is ready for use
WTX16.MOD-1
> 1 sec and < 2,5 sec Error
≥3 sec (only GPRS) Gateway is ready for use

7/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1 10.09.2009
The display of the WT…16… facilitates commissioning work and troubleshooting. In addition
to the standard display that shows the operating mode of the WTT16, there are 5 different
display levels from “A“ to “E“ that can be selected by the user.
Display level
-
Current operating mode
A
WT…16 number (primary address) and alternate
network number
B
Number of WT…16 on the network
C
Number of consumption meters on the network
D
Remaining capacity of the WTT16’s main battery
in %
E
Error code (3 groups)
There are different operating modes some of which can be selected by pressing the button
on the network node; some are selected automatically, or from a connected PC via the
ACT26 commissioning software. The selected operating mode appears on the display:
Mode Display Explanation
Idle-mode Delivery status. Switch to install mode by pressing the but-
ton MODE (>2 sec).
Standard mode This is the normal operating mode of the data collectors:
Telegrams from the metering devices can received, stored
and handled further by the network.
Extended stan-
dardmode1)
M
The receiver is always active to ensure fast communication.
This mode is automatically activated in the case of mains-
powered operation (WTX16...). It can also be started manuall
y
with the ACT26 service tool.
Installa-
tionsmode2)
In installation mode, the radio network will be built up automati-
cally. Metering devices that transmit installation telegrams in
this operating mode will be registered in the network. This
mode is started by pressing the MODE button (>2sec).
Extended in-
stalla-
tionsmode2)
M
The extended Installation mode will register all metering
devices that transmit either installation or data telegrams.
This mode is useful if network is expanded later.
Protected in-
stallations
mode 2)3)
Same as installation mode, except that connections are built up
only by devices with the same network signature.
Search
mode
This mode restores radio connection to lost or manuall
y
registered metering devices. This mode starts automatically.
Extended
search
mode2)
M
This search run is used to restore the radio connection to los
t
or manually registered metering devices.
Starting from version 2.2 this mode can also started manuall
y
by setting jumper 1 (in the plug field) and pressing the MODE
button ( >2 sec.)
Delete-mode2)3) Same as installation mode, except that all registered me-
tering devices which are transmitting installation telegrams
will be deleted. (meter replacement)
1) In battery powered network nodes this mode is terminated automatically after eight hours.
2) This mode is terminated automatically after eight hours.
3) Possibly only with the software ACT26 version 2.0 or higher
Display
Operating modes

8/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1CE1N2878en 10.09.2009
State of the
system Display Explanation
Remote
access
C
During remote access the symbol ‚ ’ will be displayed.
Highspeed-
mode
for example
M
When all network nodes have switched on their receivers fo
r
fast data exchange, this will be displayed as two dots in the
upper part of the LCD.
Bus-connection
(from version
2.2)
for example
If a connection to a bus is being built up, the number o
f
the bus and the primary address of this bus will be
briefly displayed .
In the example, network node 03 is connected to M-
BUS
IrDA-master
mode (from
version 2.2)
This mode is started by pressing the button MODE. (<
0,5 sec). It indicates readiness to connect additional
IrDA devices (in IrDA Slave mode). This mode stops
after 10 sec.
Add (from
version 2.2)
for example
If an unregistered IrDA-capable metering device (e.g.
WHE467) is connected in IrDA master mode, it can be
inserted into the network node by pressing the button
DISPLAY while ADD is displayed. The last 4 digits of device
number are indicated. (e.g. 20000123).
The registration of the device takes place and search mode
starts.
Delete (from
version 2.2)
for example
If an already registered IrDA-capable metering device is
connected in IrDA-master mode it can be removed from
the network node by pressing the button DISPLAY while
DEL is displayed. The last 4 digits of device number are
indicated (e.g. 20000123).
The removal of the device takes place and if necessary
search mode is stopped.
Copy (from
version 2.2)
for example
If a new network node (running in idle mode) is connected in
IrDA-master mode, it is possible to make a copy of all net-
work data into the new node by pressing the button
DISPLAY while COPY is displayed.
Copying lasts up to 20 minutes. At the end "StArt Prot" is
displayed on LCD of the new network node for 1 hour. Afte
r
mounting the new node the protected mode is also started
by pressing the DISPLAY button. By this procedure the ne
w
network node is integrated in network and search mode is
started automatically.
Engineering notes
For detailed engineering instructions, refer to the QUNDIS Engineering Manual CE1J2870.
Commissioning of WTX..
For mains-powered WTX16.... network nodes, the mains connections are to be made first at
the selected mounting positions (typically on every second floor, mounting height ≥2 m).
Engineering

9/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1 10.09.2009
S
N L
R1 ... Rn
M1 M2
S switch
L, N AC 230 V mains supply
M1, M2 M-Bus output
R1 ... Rn optional interface(s)
1
23
1 Mains connection L and N
2 Permanently installed mains cable (no flexible
power cable!)
3 Extra insulation (shrink sleeve)
Connect the AC 230 V power supply line to the power pack of the WTX16… in the
following order: Remove the upper housing section of the WTX16… from the
base. For that purpose, remove the 2 cable connections (power supply (4) and M-
Bus (6)) between gateway and base. Then, use a suitable tool (screwdriver or
similar) to slightly open one of the two lateral fixing levers so that upper housing
section and base can be separated. Then, the top section of the WT…16 is to be
fitted using 2 dowels and screws (spacing of dowels is 184 mm with the
WTX16...).
Connection of the AC 230 V power line to the power pack of the WTX16... is to be made as
follows:
A 2-core mains cable (L and N) has to be preinstalled at the mounting site already. The
power pack must be connected by qualified staff. The cores must be sheathed with the en-
closed insulating sleeves to ensure compliance with safety class II. Then, the live (L) and
neutral (N) conductors must be connected to terminal “IN” of the power pack. Mains voltage
must be in the range from AC 100 to 240 V (50 / 60 Hz). There is no protective earth (PE)
connection. Then, cable strain relief must be provided by fitting cable ties.
Once the top section of the WTX16 is fitted, the housing with the electronics can be snapped
on. Then, the power supply connector can be plugged into the electronics section and the
WTT16 switched to installation mode by pressing the MODE button (red) for a few seconds.
Then, additional network nodes or consumption meters of the Q AMR system can automati-
cally configure themselves to form a network.
The standard baud rate of M-Bus master is 2400 Bd. To include 300 Bd M-Bus search it is
possible to switch this feature by parameterization software ACT21.
For updating M-bus device directory, there is an automatic search run for new connected
devices every 28 days. Devices, disconnected from M-bus, will be automatically deleted
from directory after 7 days.
After complete installation of all meters and network nodes, the gateway has to do a search
run to find all devices of network(s).
The search run started by triggering a command at the connected PC or by remote using the
software ACS26.
Connection diagram
CAUTION:
Connect the mains cable to
the power supply unit only!
Mains connection
Search run

10/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1CE1N2878en 10.09.2009
GSM antenna of WTX16.GSM
Screw tight the GSM antenna prior to commissioning
Perspective
SIM card
Network nodes WTX16.GSM and WTX16.MOD-1 require a SIM card and GSM- or GPRS
service contracts for voice- and data service. SIM cards, only sold for voice service or M2M
service, cannot be used.
For that purpose, remove the upper section of the WTX16.GSM from the base. Press the
SIM card slightly in the slot at the bottom of the gateway. Ensure that the chamfered corner
is in the correct position.
12
1. SIM card
2. Card ejector
The cardholder is easily accessible
1
1. SIM card holder
Ensure that the cham-
fered corner of SIM
card is in the correct
position.
WTX16GSM
WTX16.MOD-1

11/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1 10.09.2009
WTX16.IP
The WTX16.IP network node features an Ethernet interface, which connects to the outside
world via an RJ45 connector, where the net-work cable is to be connected.
The distance to the network conduit box may not exceed 2 meters.
It is possible, to choose fixed or dynamic (DHCP) IP addresses for WAN communication.
The transmission in WAN can be done secured by SSL or unsecured.
Parameter setting
The WTX16.GSM, WTX16.MOD and WTX16.IP network nodes are parameterized with the
ACT21 software. The scope of delivery of the software includes an RS-232 cable for con-
necting the PC to the gateway.
Sealing
On completion of commissioning, secure the network node with the seal provided. Insert the
seal in the opening to the right of the network node.
Safety guidelines
After opening the housing, certain parts of the device / system that become accessible carry
dangerous voltage. Only qualified staff may interfere with such devices / sys-tems.
To ensure correct and safe operation, the pro-duct must be adequately shipped, stored,
installed, operated and maintained.
Staff dealing with the product must be familiar with all potential hazards and maintenan-
ce measures in accordance with the instructions given in this document.
It must be possible to disconnect the device from the power supply at an easily acces-
sible point (e.g. a switch in the power cable)
The connection cable has to be protected by an appropriate fuse. Whenever performing
any work on the WTX16..., disconnect the device from the mains supply.
Non-observance of these warning notes can lead to personal injury or damage to
property!
The local regulations for electrical installations and wireless systems must be complied with.
Pursuant to the "Verordnung über Allgemeine Bedingungen für die Elektrizitätsversorgung
von Tarifkunden (AVBEltV)" of the Ministry of Economics, electrical installations behind the
house’s fused connection may only be erected, extended, changed and maintained by elec-
trical installers that are registered with an electric utility. They must ensure that the general
technical regulations and legal safety regulations are complied with.
M-Bus connection
Each network node has a plug terminal for a permanently installed M-Bus connection. A
fitting plug is included.
RESET
MODE
permanently connected M-Bus
max. 5 unit loads
temporary
M-Bus connection
(WTX16.GSM, WTX16.IP:
connection to gateway)
In Germany:

12/12
www.qundis.com Network nodes with gateway WTX16.GSM/IP/MOD-1CE1N2878en 10.09.2009
Technical data
conformity to EMC directives
Protection degree IP 32 (WTX16.IP has IP21)
Safety class 2
Electromagnetic compatibility Immunity: EN 55 024/EN 301 489
Emissions: EN 55 022/EN 300 220-1
Operating voltage WTX16... AC 100..240 V 50/60 Hz
Rated frequency 868,3 MHz
Transmitter power < 14 dBm
Frequency of transmission <1 %
Permanent ambient temperature
Transport and storage
Operation
20...+60 °C (< 30 °C recommended)
0...55 °C
Weight 0,3 kg
Dimensions
184
31,8
9,7
200
60
R
150
R
100
150
250
250
R
55
250
2,5
R
WTX16...
The information provided in this Data Sheet only gives general descriptions and general technical features
which, in the case of specific applications, may not necessarily apply, or which may change due to further
development of the product. Technical features are binding only when expressly agreed upon at the time a
contract is concluded.
©2009 QUNDIS GmbH
Subject to alteration
This manual suits for next models
2
Other QUNDIS Data Logger manuals