Qvis AMB-EYE1.3 User manual

AMB-EYE1.3
AMB-EYE2
AMB-EYE3
1.3 / 2 / 3 MEGA PIXEL EYEBALL DOME IP CAMERAS
User’s Manual
V2.0 06 / 2014

i

ii
Welcome
Thank you for purchasing the:
1.3, 2 or 3 Mega Pixel Eyeball Dome IP Cameras
This user’s manual is designed to be a reference tool for the installation and
operation of your system.
Here you can find information about the corresponding IP camera’s features
and functions, as well as a detailed installation method.
Before installation and operation please read the following safeguards
and warnings carefully!

iii
Important Safeguards and Warnings
1.Electrical safety
All installation and operation here should conform to your local electrical safety codes.
The power supply shall conform to the requirement in the SELV (Safety Extra Low Voltage) and
must make sure that the limited power source is rated 12V DC or 24V AC.
Please note: Do not connect two power supplying sources to the device at the same time; it
may result in device damage!
We assume no liability or responsibility for all the fires or electrical shock caused by improper
handling or installation.
We are not liable for any problems caused by unauthorized modification or attempted repair.
2.Transportation Security
Please ensure that the product does not endure heavy stresses, violent vibration or contact with
water during transportation, storage and installation.
Please use the original packing material (or the material of the same quality) if you need to return it
to vendor.
3.Installation
Do not apply power to the product before completing installation.
Do not put object(s) on the product.
Please install a proper power cut-off device during the installation connection.
4.Qualified engineers needed
All the examination and repair work should be done by the qualified service engineers. We are not
liable for any problems caused by unauthorised modifications or attempted repair.
5. Environment
This product should be installed in a cool, dry place away from direct sunlight, inflammable,
explosive substances and etc.
Please keep it away from environments that contain electromagnetic radiation or objects that
produce it.
Please keep sound ventilation around the device at all times.
Do not allow the water and other liquid to penetrate into the device if casing has been
compromised. This series product complies with the IP66 standard specified in the Degrees of
Protection Provided by Enclosure.
Ensure lightning surge protection is in place to make sure you fully protect camera circuitry from
electrical overload.

iv
Please make sure the CCD (CMOS) component is away from the radiation of the laser beam
device. Otherwise it may result in CCD (CMOS) optical component damage.
It is recommended that the grounding studs of the product should be grounded, so to further
enhance the reliability of the camera.
6. Daily Maintenance
Please shut down the device and then unplug the power cable before you begin any maintenance
work.
Do not touch the CCD (CMOS) optic component. Please use an air jet to clean the dust off the lens
surface. You can use the dry cloth with some alcohol or mild detergent to clear if necessary.
When the camera is not in use please put the dustproof cap to protect the CCD (CMOS)
component.
Do not use volatile solvent such as the benzene, paint thinner or detergent with the ability to
abrade surfaces. It may result in lens damage or adversely affect the device’s performance.
7. Accessories
Always use all the accessories recommended by manufacturer.
Before installation, please open the package and check that all the components are included. Contact
your local retailer/vendor ASAP if something is missing.
8. Box Contents:
Accessory Name
Amount
Network Camera Unit
1
User’s Manual
1
Installation Accessories Bag
1
CD
1

v
Table of Contents
1General Introduction ..................................................................................................................1
1.1 Overview........................................................................................................................1
1.2 Features.........................................................................................................................1
1.3 Specifications................................................................................................................2
1.3.1 Performance...........................................................................................................2
2Structure ......................................................................................................................................5
2.1 Components..................................................................................................................5
2.2 Framework and Dimension.........................................................................................6
3Device Installation ......................................................................................................................7
3.1 Installation Steps ..........................................................................................................7
3.2 Restore Factory Default Setup Introduction.............................................................9
4Quick Configuration Tool.........................................................................................................10
4.1 Overview......................................................................................................................10
4.2 Operation .....................................................................................................................10
5Web Operation..........................................................................................................................13
5.1 Network Connection...................................................................................................13
5.2 Login and Logout........................................................................................................13
6FAQ ............................................................................................................................................16

© Copyright Qvis ®. All documentation rights reserved.
1
1General Introduction
1.1 Overview
This network camera integrates traditional camera and network video technology. It adopts both audio and
video data collection and transmission simultaneously. Because of inbuilt internal hardware it can connect
to a network directly without any auxiliary device. When you want to access the camera, you can use a web
browser running off the network at the client-end. Due to its multiple functions it allows for various use in
many environments such office, bank, road & traffic monitoring, etc.
The latest chipset technology incorporated within the camera design requires low amounts of power to
obtain the best video image clarity. Energy efficiency is a key element to this product, but at the same time
it does not compromise on performance.
This series network camera product uses the latest industry standard H.264 video and G.711a audio
compression technology, which guarantee the best audio and video quality whilst reducing file sizes.
One of the other main features this camera includes is the IR night vision, which aids in video surveillance
when the camera is functioning within a low illumination environment. The LED IRs highlight objects of
interest within the camera’s field of view and is then able to filter out any visual interference so that you can
easily view footage upon a monitor. It supports real-time monitor and listening at the same time via the
inbuilt microphone. If you want to communicate with a person(s) in view of the camera it also supports dual-
way bidirectional talk.
The built-in protection enclosure and waterproof design conforms to the IP 66 level. It has sound waterproof
function suitable for use in the outdoor environments.
1.2 Features
User
Management
Different user rights for each group, one user belongs to one group.
The user’s right shall not exceed the group right.
Storage
Function
Supports:
Central server backup function in accordance with your configuration and
setup in alarm or schedule setting
Recording via the Web and sending the recorded file to the storage at the
client-end’s PC.
Network storage function such as FTP.
Network
Monitor
Network camera supports one-channel audio/video data transmission to
network terminal and then decodes signal. Delay is within 270ms (network
bandwidth support needed)
Supports a maximum of 20 connections.
Adopts the following audio and video transmission protocols: HTTP, TCP,
UDP, MULTICAST, RTP/RTCP, RTSP, etc.
Supports web access.
Network
Management
Allows network camera configuration and management via Ethernet.
Supports device management via web or client-end.
Power
External power adapter DC12V.
Supports s PoE supply

© Copyright Qvis ®. All documentation rights reserved.
2
Warning!
Do not connect these two power supplying sources to the device at the same
time; it may result in device damage!
Please note: system cannot support these two types of power supplying at the same
time. As a recommendation, if you wish for your security system to be continue to run
when there is a loss of power or unstable electrical supply coming from the mains, a
UPS system should be installed.
Assistant
Function
Log function
Supports system resource information and running status real-time display.
Day/Night mode auto switch.
Built-in IR light. Supports IR night vision.
Supports motion detect.
Supports picture parameter setup such as electronic shutter and gain setup.
Backlight compensation: screen auto split allows backlight compensation to
adjust the brightness.
Supports video watermark function to avoid vicious video modification.
The enclosure conforms to the IP66 protection testing. It can withstand a
variety of weather conditions and outdoor environments.
1.3 Specifications
1.3.1 Performance
Please refer to the following sheet for network camera performance specification:
Model
Parameter
AMB-EYE1.3
AMB-EYE2
AMB-EYE3
System
Main Processor
Ambarella A5s high performance DSP
OS
Embedded LINUX
System
Resources
Support real-time network, local record, and remote operation at the
same time.
User Interface
Remote operation interface such as WEB, PSS
System Status
Bit stream statistics, log, and software version.
Video Parameter
Image Sensor
1/3-inch CMOS
1/2.8-inch CMOS
1/3 –inch CMOS
Pixel
1280(H)x960(V)
1920(H) x 1080(V)
2048(H) x 1536(V)
Day/night
Supports day/night mode switch
Gain Control
Fixed/Auto
White Balance
Manual/Auto
BLC
On/Off
Exposure Mode
Manual/Low Noise/Low motion blur/Auto
PAL: It ranges from 1/3 to 1/10000
NTSC: It ranges from 1/4 to 1/10000
Video
Compression
Standard
H.264/JPEG/MJPEG

© Copyright Qvis ®. All documentation rights reserved.
3
Video Frame
Rate
PAL:
Main stream:
(1280x960@15fps)
Extra stream:
(704×576)
PAL:
Main stream
(1920*1080@25fps),
Extra stream,
(704*576@25fps)
PAL:
Main stream 1,
(2048*1536@20fps),
Extra stream1,
(704*576@25fps)
Extra Stream 2,
(1280*720@11fps)
Main stream 2,
(1920*1080@25fps)
Extra stream 1,
(704*576@25fps)
Extra Stream 2,
(1280*720@11fps)
NTFC:
Main stream:
1280x960@15fps)
Extra stream:
(704×576)
NTSC:
Main
stream(1920*1080@
30fps),
extra stream,
(704*576@30fps)
NTSC:
Main stream 1,
(2048*1536@20fps),
Extra stream1,
(704*480@25fps)
Extra Stream 2,
(1280*720@11fps)
Main stream 2,
(1920*1080@25fps)
Extra stream 1,
(704*480@25fps)
Extra Stream 2,
(1280*720@11fps)
Video Bit Rate
H.264H: 40Kbps-8192Kbps adjustable
MJPEG: 40Kbps-16384Kbps adjustable and bit rate is adjustable.
Support customized setup.
Video Flip
Support mirror.
Support flip function.
Snapshot
Max 1f/s snapshot. File extension name is JPEG.
Privacy Mask
Supports max 4 privacy mask zones
Video Setup
Support parameter setup such as brightness, contrast.
Video
Information
Channel title, time title, motion detect, camera masking, tampering.
Lens
3.6mm, 6mm, 2.8mm
Fixed
3.6mm, 6mm. Fixed
Lens Interface
M12. Lens is the default accessories
Video
Motion Detect
396 (18*22) detection zones;sensitivity level ranges from 0 to 100
Activation event: video storage, image snapshot, log, email function
and etc.
Record and
Backup
Record Priority
Manual>Video detect>Schedule
Storage
Management
Support FTP storage.

© Copyright Qvis ®. All documentation rights reserved.
4
Network
Wire Network
1-ch 10/100 M Ethernet, RJ45 port
Network Protocol
HTTP, TCP/IP, ARP, RTSP, RTP,UDP, RTCP, SMTP, FTP, DHCP,
DNS, DDNS, PPPOE, IPv4/6, SNMP, UPNP, NTP
Remote
Operation
Monitor, system setup, file download, log information, maintenance ,
upgrade, Etc.
Restore Default
Setup
Built-in Reset button
IR light
IR light 10-20M.
General Parameter
Power
DC12V power and PoE.
Warning!
Do not connect these two power supplying sources to the device
at the same time; it may result in device damage!
Power
Consumption
4W MAX, DC 12V
Working
Temperature
-30oC ~+60oC
Working
Humidify
≤95%
Dimensions(mm)
Φ113×86
Weight
280g(Excluding box)
400g (Excluding box)
280g (Excluding box)
Installation
Fixed on the wall, ceiling, etc.

© Copyright Qvis ®. All documentation rights reserved.
5
2Structure
2.1 Components
You can refer to the following figure for multiple-function combination cable information (see Figure 2-1).
Figure 2-1
Please refer to the following sheet for detailed information:
No.
Port
Name
Connector
Note
4
LAN
Network
port
Ethernet
To connect to standard
Ethernet.
5
DC12V
DC 12V
power
To connect to DC12V power
supply.
Component
Component Name
Component 1
Device lens
Component 2
Dome body
Component 3
Dome enclosure

© Copyright Qvis ®. All documentation rights reserved.
6
2.2 Framework and Dimension
Please refer to the following two figures for dimension information. The unit is mm. See Figure 2-2 and
Figure 2-3.
Figure 2-2
Figure 2-3

© Copyright Qvis ®. All documentation rights reserved.
7
3Device Installation
3.1 Installation Steps
Important:
Before the installation, please make sure the installation environments can support at least 3x
weight of the camera.
Please follow the steps listed below to install the device. Please refer to Figure 3-1 for reference.
Step 1: Turn clockwise to remove the decoration ring from the snap joints.
Step 2: Please take out the installation position map from the accessories bag, and then paste it on the
ceiling or the wall according to your monitor area requirements. Draw and then dig three plastic expansion
bolts holes in the installation surface and then insert three expansion bolts in the holes. Secure these three
bolts firmly. Please draw the cable out from the cable exit when you install the device.
Step 3: Adjust the device installation pedestal to the proper position and then line up the three screw holes
in the device pedestal to the three plastic expansion bolt holes in the installation position. Put the three self-
tapping screws in the three plastic expansion bolts firmly. Loosen the M3X8 cross recessed pan head slot
screw of the pedestal to unfasten the preforming. (Do not remove, loosen a little bit will be OK.). Adjust the
lens to the proper monitor angle and then use the original preforming to turn the M3X8 cross recessed pan
head slot screw back.
Step4:
Line up the three spigots of the decoration ring to the jags from the bottom to the top and then turn
clockwise until you hear a clear sound ”KA”. Now the installation is complete.
Figure 3-1

© Copyright Qvis ®. All documentation rights reserved.
8
Important
Please pay attention to the dome camera direction when you are installing. Please refer to the following
figure for detailed information. See Figure 3-2.
Figure 3-2
Note
This series product supports two cable exits. One is from the bottom and the other is from the side. Please
refer to the following figure for cable exit from the side information.
Figure 3-3

© Copyright Qvis ®. All documentation rights reserved.
9
Please earth the GND port of the device to enhance the device reliability. The GND port is near the cable
exit port on the rear of the dome. The GND screw uses the M2X5 pan screw.
Figure 3-4
3.2 Restore Factory Default Setup Introduction
Important:
Please use RESET button when device is running.
Step1: Please refer to Step 1 and Step2 in Chapter 3.1 to loosen the dome body. Push a little bit; you can
take the dome body from the dome cover.
Step2: Take the dome body out and then turn the top cover hard to remove.
Step3: Slightly press the RESET button to complete the reset function (see Figure 3-5).
Step4: Turn the top cover back to the original position. Please make sure it reaches the original position,
otherwise it may result in water leaking into the housing!
Step5: Put the dome back to the dome cover. Please refer to Step 4 in Chapter 3.1 to install the decoration
ring back.
Figure 3-5

© Copyright Qvis ®. All documentation rights reserved.
10
4Quick Configuration Tool
4.1 Overview
Quick configuration tool can search current IP address and modify IP address. At the same time, you can
use it to upgrade the device.
Please note: the tool only applies to the IP addresses in the same segment.
4.2 Operation
Double click the ‘ConfigTools.exe’ icon and you will see an interface just like the one shown as in Figure
4-1.
In the device list interface, you can view the device’s IP address, port number, subnet mask, default
gateway, MAC address, etc.
Figure 4-1 Search interface
Select one IP address and then right click mouse, you will see an interface like the one shown in Figure 4-2.
Note: You can set the IP address, subnet mask and gateway for the network camera & PC. The network
camera IP address and PC IP address should be in the same network segment if there is no router.
Network camera default IP address is 192.168.1.108. If there is a router, please set the corresponding
gateway and subnet mask.
The factory default user name is admin and password is admin. For security reasons, please modify your
password after you first login.
For detailed WEB operation, please refer to the Network Camera Web Operation Manual in the
resource CD.

© Copyright Qvis ®. All documentation rights reserved.
11
Figure 4-2 Search interface 2
Select the ‘Open Device Web’item; you can go to the corresponding web login interface (see Figure 4-3).
Figure 4-3 Web login
If you want to modify the device IP address without logging in to the device web interface, you can go to the
configuration tool’s main interface to set.
In the configuration tool’s search interface (Figure 4-1), please select a device IP address and then double
click it to open the login interface. Or you can select an IP address and then click the Login button to go to
the login interface. See Figure 4-4.
In Figure 4-4, you can view device IP address, user name, password and port. Please modify the
corresponding information to login.

© Copyright Qvis ®. All documentation rights reserved.
12
Please note the port information here shall be identical with the port value you set in TCP port in Web
Network interface. Otherwise, you cannot login the device.
If you are using device background upgrade port 3800 to login, other setups are all invalid.
Figure 4-4 Login prompt
After you logged in, the configuration tool main interface is shown as below. See Figure 4-5.
Figure 4-5 Main interface
For detailed information and operation instructions of the quick configuration tool, please refer to
the Quick Configuration Tool User’s Manual included in the resources CD.

© Copyright Qvis ®. All documentation rights reserved.
13
5Web Operation
This IP camera product supports the Web access and management using a PC.
Web includes several modules: monitor channel preview, system configuration, alarm, etc.
5.1 Network Connection
Please follow the steps listed below for network connection:
Make sure the network camera has connected to the network properly.
Please set the IP address, subnet mask and gateway of the PC and the network camera
respectively. Network camera default IP address is 192.168.1.108. Subnet mask is 255.255.255.0.
Gateway is 192.168.1.1
Use order ping ***.***.***.***(* network camera address) to check connection is OK or not.
5.2 Login and Logout
1. Open web browser and input network camera address in the address bar.
For example, if your camera IP is 192.168.1.108, then please input http:// 192.168.1.108 into the
web browser’s address bar. See Figure 5-1.
Figure 5-1 IP address
2. The login interface is shown as below. See Figure 5-2.
3. Please input your user name and password.
4. Default factory name is admin and password is admin.
Note: For security reasons, please modify your password after you first login.
Input your IP
address here

© Copyright Qvis ®. All documentation rights reserved.
14
Figure 5-2 Web login
If it is your first time logging in, the system pops up warning information to ask you whether to install the
control ‘webrec.cab’or not, after you have logged in for one minute. Please click OK button, the system
can automatically install the control. When system is upgrading, it can overwrite the previous Web as well.
If you can’t download the ActiveX file, please check whether you have installed the plug-in to disable the
control download. Or you can lower the web browser’s security level. See Figure 5-3.
Figure 5-3 IE security level
This manual suits for next models
2
Table of contents
Other Qvis IP Camera manuals
Popular IP Camera manuals by other brands

Planet Networking & Communication
Planet Networking & Communication ICA-HM230 user manual

Digiguard
Digiguard C-DG-PD2421POE user manual

D-Link
D-Link Securicam Network DCS-2000 manual

D-Link
D-Link SECURICAM Network DCS-2100 user manual

Interlogix
Interlogix TruVision 12 Series installation guide

Digiguard
Digiguard C-DG-PD2421POE quick start guide