METEOROLOGICAL
INSTRUMENTS
MODEL 41382VC/VF RELATIVE HUMIDITY/
TEMPERATURE PROBE, 0-1 V OUTPUT
INSTRUCTION MANUAL
MODEL 41382VC/VF
RELATIVE HUMIDITY/TEMPERATURE PROBE, 0-1 V OUTPUT
INSTRUCTION SHEET 41382V-90
REV A072804
R. M. YOUNG COMPANY 2801 Aero Park Drive , Traverse City, Michigan 49686 USA
TEL (231) 946-3980 FAX (231) 946-4772
INTRODUCTION
The Model 41382VC/VF Relative Humidity/Temperature Probe com-
bines a high accuracy humidity sensor and temperature sensor in one
probe. The probe is available in Celsius or Fahrenheit calibration.
Output signal is 0-1V for both Relative Humidity and Temperature.
INSTALLATION
The Relative Humidity/Temperature probe should always be installed
in a protective radiation shield to ensure accurate data. Use of the
probe without a radiation shield may result in large errors. The probe
installs easily in YOUNG naturally ventilated or motor aspirated
shields. For best performance, the probe and shield should be placed
in a location with good air circulation clear of large masses (buildings,
pavement, solar panels...), exhaust vents, electrical machinery and
motors, water fountains and sprinklers.
MAINTENANCE
The Relative Humidity/Temperature probe is designed to offer years
of service with minimal maintenance. As with most humidity sensors,
humidity calibration may drift slightly with time. Recalibration will
restore probe to acceptable limits.
In areas of high dust or contamination (ie: smokestacks, seawater),
periodic cleaning of the RH sensor protective filter is recommended.
Soaking in clean water or a mild soap solution is recommended. DO
NOT USE SOLVENTS.
CE COMPLIANCE
This product has been tested and shown to comply with European CE
requirements for the EMC Directive. Please note that shielded cable
must be used.
WARRANTY
This product is warranted to be free of defects in materials and
construction for a period of 12 months from date of initial pur-
chase. Liability is limited to repair or replacement of defective
item. A copy of the warranty policy may be obtained from R. M.
Young Company.
Declaration of Conformity
Application of Council Directives: 89/336/EEC
Standards to which Conformity is Declared: EN 50081-2 (IEC 801-2, 3, 4)
EN 50082-2
Manufacturer's Name and Address: R. M. Young Company
Traverse City, MI, 49686, USA
Importer's Name and Address: See Shipper or Invoice
Type of Equipment: Meteorological Instruments
Model Number / Year of Manufacture: 41382 (V, L)/2004
I, the undersigned, hereby declare that the equipment specified conforms to the
above Directives and Standards.
Date / Place: Traverse City, Michigan, USA July 28, 2004
David Poinsett
R & D Manager, R. M. Young Company
SPECIFICATIONS
Power Required: 12-28 VDC, 10 mA
RELATIVE HUMIDITY:
Measuring range: 0-100% RH
Accuracy at 20-25°C: ±2%
Stability: Better than ±1%RH per year
Response Time: 10 seconds (Without Filter)
Sensor type: Rotronic Hygromer
Output signal: 0-1V
TEMPERATURE:
Calibrated measuring
range: -50 to +50°C (suffix C)
-50 to +150°F (suffix F)
Accuracy at 20-25°C: ±0.3°C
Response Time: 10 seconds (Without Filter)
Sensor type: 100 Ohm Platinum RTDW
Output signal: 0-1V
Recommended Cable: 5 COND shielded, 22 AWG (#18446)
Recommended Radiation Shields:
Model 43408P Gill Aspirated Radiation Shield
Model 41003P Gill Multi-Plate Radiation Shield

This manual suits for next models

1

Other R.M. Young Measuring Instrument manuals

R.M. Young 05103L User manual

R.M. Young

R.M. Young 05103L User manual

R.M. Young 05305L User manual

R.M. Young

R.M. Young 05305L User manual

R.M. Young 27106T User manual

R.M. Young

R.M. Young 27106T User manual

R.M. Young 05305V User manual

R.M. Young

R.M. Young 05305V User manual

R.M. Young 05103V User manual

R.M. Young

R.M. Young 05103V User manual

R.M. Young 52202 User manual

R.M. Young

R.M. Young 52202 User manual

Popular Measuring Instrument manuals by other brands

LDG FTL-Meter Operation manual

LDG

LDG FTL-Meter Operation manual

Huazheng HZSM-701 Operation manual

Huazheng

Huazheng HZSM-701 Operation manual

gaskatel FlexCell PTFE user manual

gaskatel

gaskatel FlexCell PTFE user manual

VOLTCRAFT VPT-100 operating instructions

VOLTCRAFT

VOLTCRAFT VPT-100 operating instructions

Sureshotlaser PINLOC 2000 user manual

Sureshotlaser

Sureshotlaser PINLOC 2000 user manual

TESTO 610 instruction manual

TESTO

TESTO 610 instruction manual

Pahlen Autocheck 15 user manual

Pahlen

Pahlen Autocheck 15 user manual

Genie WONVR14P5 quick start guide

Genie

Genie WONVR14P5 quick start guide

PCE Instruments PCE-127 Series manual

PCE Instruments

PCE Instruments PCE-127 Series manual

PeakTech 5145 Operation manual

PeakTech

PeakTech 5145 Operation manual

Simrad PI32 Operator's manual

Simrad

Simrad PI32 Operator's manual

Extech Instruments 407860 user manual

Extech Instruments

Extech Instruments 407860 user manual

KEYCO KK001WH00W/ESM user manual

KEYCO

KEYCO KK001WH00W/ESM user manual

Chauvin Arnoux C.A762 user manual

Chauvin Arnoux

Chauvin Arnoux C.A762 user manual

YOKOGAWA 7556 user manual

YOKOGAWA

YOKOGAWA 7556 user manual

Sylvac S Depth PRO instructions

Sylvac

Sylvac S Depth PRO instructions

Dostmann Electronic VA893 user manual

Dostmann Electronic

Dostmann Electronic VA893 user manual

Worldcast Systems Audemat DVB-T Monitor user manual

Worldcast Systems

Worldcast Systems Audemat DVB-T Monitor user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.