PRODUCT SPECIFICATION
Features:
2 Channels BBQ/Oven monitor.
LORA WAN connectivity
IP66 waterproof.
High/low alarm setting.
Min/max temperature reading
Loud alarm sound
Clear LCD display with backlight
External adapter and battery power
Fan control
Specification:
Measuring range -58 ~ 572 F / -50 ~ 300C
Temperature accuracy ±1.8F(±1 C) between -4F to 248F(-20 to 120C)
±3.6F(±2 C) between -58F to -4F / 248 to 392F(-50 to -20 C /120 to 200C)
±5.4F (±3 C) between 392~572F(200 to 300C)
Wireless distance About 2000 meters in open areas
Display resolution Current temperature 0.1,min/max and alarm limit set 1
Alarm sound volume About 90dB (300mm distance)
Unit reading update 1 second
Receiver reading update 30 seconds
Water resistant rating IP66
Power 2 pieces AA alkaline batteries, external adapter power input
Battery life Transmitter about 125 hours, receiver about 1800 hours
Display size Transmitter 59(W) X 78 (H) mm, receiver 35(W) X 59 (H) mm,
Probe Curved probe: 3.5() x 150(L) mm, tip 2.2() x 10(L) mm, cable length 1200mm.
Straight probe: 3.5() x 51(L) mm, cable length 1200mm.
Product size Transmitter 90 (W) x 119(H) X 28(D)mm , receiver 52 (W) x 113(H) X 28(D)mm
Working temperature Main part 32 ~ 122 F/0 ~ 50 C, cable 700F/371C, probe handle 644F/340C
Attachment 1 piece curved probes, 1 piece straight probe, 1 piece air clip.
Operation
1. Insert all the probes with the correct number. Connect the external power.
2. Press [ON-OFF] button to turn on the unit, the backlight will turn on 10 seconds.
3. Press [ON-OFF] button and hold for 3 seconds to turn off the unit.
4. Press [ON-OFF] button and hold for 10 seconds then release to reset the unit.
Select temperature unit
Press [C/F] button to select the temperature unit.
Low and high temperature alarm setting
1. Press [CH] button to select the channel for alarm setting. All the icons flashing that you selected.
2. Press [SET] button to enter alarm on-off setting. Press [▼] or [▲] button to set the alarm on or off.
3. Press [SET] button once again to enter high alarm limit setting mode, high alarm value will be flashing. Press [▼] or [▲] button to
set the high alarm limit.
4. Press [SET] button once again to enter low alarm limit setting mode, low alarm value will be flashing. Press [▼] or [▲] button to set
the low alarm limit.
5. Press [SET] button once again to finish the alarm setting.
6. If the temperature reading is out of the limited, the alarm will sound, the “LOW” or “HIGH” icon flash, press any key to stop the alarm
sound, the low alarm or high alarm icon will be flashing continue.
7. Alarm sound: the channel 1 alarm sound is “di - - -“, the channel 2 alarm sound is “di di - -“.
* If the both alarms sound active, the last alarm sound will be instead the before one.
* The default low alarm value is 32F, the default high alarm value is 160F,
Backlight control
1) Press [ ] button to switch backlight on or off. The backlight will be turn on 20 seconds, and then turn off automatically.
Volume adjustment
Product number: TMW023-2P and TMW023-2PR. Product name: SMOKE X2 transmitter and receiver Versions: V1.0
Receiver and transmitter are two products that are used simultaneously,The receiver and transmitter
use the same module, and the module is a two-way transceiver.

1. Press [VOL] button to adjust volume level.
2. When the volume class is , it mean that the alarm sound is off.
3. When power up, the sound volume level is the third class.
Calibration
1) Press [CH] button to select the channel for calibrate.
2) Press [CAL] button to enter the calibration mode, “CAL”flash, press [▼] or [▲] button to set reading error.
3) Press [CAL] button again to exit the calibration mode.
The errors adjust range is -4~4F.
Wireless control
1. Press [ ] button to turn on or off the wireless function. When power on, transmission function is on.
Receiver control
1. Press [ ] button to turn on the unit.
2. Press [ ] button to turn on the backlight 20 seconds.
3. Press [ ] button and hold for 3 seconds to turn off the unit.
4. Press [VOL] button to adjust volume level.
5. When the unit alarm, press any button to stop the alarm sound. This situation will send back to the transmitter and mute the alarm
sound.
Code rematch
1. The transmitter has already been synchronized with the receiver at ex-factory setting. If rematch is needed, press and hold [ ]
button for 5 seconds. Rematch mode would start and “Sync” icon will appear in the display.
2. Press and hold [VOL] button for 5 seconds to start rematch.
3. The units would restore the code automatically and return to normal mode.
NOTE:
1. Clean the probe immediately with cleaning wipes after each measurement to avoid cross contamination.
2. Do not expose thermometer to temperatures over 50C/ 122 F or use in ovens, otherwise incorrect readings or damage to the
thermometer may result.
ERROR SYMBOLS:
Symbol Description Action required
Full battery
Low battery Replace the battery with the same type
Battery level indication (75%/50%/25%)
EXT POWER Power adapter connecting
CAL Calibrating
SET TEMP Fan connecting
LLL.L The reading is out of low range(-58 F -50C) Keep the measurement above low range
HHH.H 1.Sensor short circuit
2.The reading is out of high range (572 F/300C) 1.Return the thermometer for repair
2. Keep the measurement below high range
NO PROBE! 1.The sensor open circuit
2.The sensor probe is not connect 1.Return the thermometer for repair
2.Connect the sensor probe correctly
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator
and your body. This device complies with Industry Canada Licence-exempt RSSs. Operation is subject to the
following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference, including interference that may cause undesired operationofthedevice.
Pour maintenir la conformité aux directives d'exposition aux radiofréquences, cet équipement doit être
installé et utilisé avec une?distance minimale de 20 cm entre le radiateur et votre corps.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts
de licence. L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est
susceptible d'en compromettre le fonctionnement.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15
of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
Transmitter: FCC ID: 2AI67-S2T, IC: 22116- S2T. Receiver: FCC ID: 2AI67-S2R, IC: 22116- S2R.
Mark Wu
2020JAN07
Any Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
The products are usually hung on a wall or placed on a table for use.
Two positions on the back of the product are magnets that can be attached to the metal wall.
This manual suits for next models
1
Table of contents
Other Radiance instruments Receiver manuals