Radionode RN400-H2PS User manual

RN400 H2
RADIONODE WiFi DATA LOGGER
✓Supports WiFi b/g/n 2.4GHz
✓Connects to temperature-humidity, NTC
external sensors
✓Supports micro SD/ embedded F-RAM
✓Supports cloud monitoring(Tapaculo365)
✓OLED screen/ sound buzzer installed
✓Waterproof (IP66 standard)
✓Uses C batteries
Product Overview
RN400-H2 is a WiFi-based data logger with a high-performance temperature-humidity sensor
installed. Powered by batteries, it operates in wireless settings and its waterproof and dustproof
design allows for application in a wide range of working conditions. All sensor data is transmitted in
real-time to Tapaculo365 or any other web software. The OLED screen installed on the front allows
users to check data as well as the setup values, and the Micro SD card slot allows for storage of
the measured data as well as supports the use of RN400-H2 in WPA2-enterprise settings. F-RAM,
known for high durability, is used for internal memory, which allows data storage up to a maximum
18 days without any connection to the Internet. Moreover, as it comes with various interface
terminals, RN400-H2 can be linked with several devices, including the external sensors, door
sensors, and dry contact.
Potential Applications Block Diagram
• Collect sensor information via network
• Build an integrated control system
• Build an industrial alarm system
Currently-In-Use Applications
• Food storage sites(refrigerators, freezers)
• Bio-labs
• Building energy usage monitoring
• Medicine and medical goods storage sites
• Semiconductor production lines
Order Number
• RN400H2PS • RN400H2EX
• RN400H2PS-S • RN400H2EX-S

Caution / Warning
Warning
1. When used in combination with large-scale devices that may potentially lead to casualties or
property losses or damages, ensure to use after installing dual safety controls.
These applications may lead to serious fires, human accidents, and property losses or damages.
2. As the product is not explosion-proof, do not use near flammable gases.
Possibility of explosions.
Caution
1. Replace batteries with the power turned off.
RTC embedded within the product may be damaged and cause functional errors.
2. Refrain from using in extreme or non-supported environments.
This leads to shorter product lifespan and may cause breakdowns or malfunctions.
3. Do not use power that exceeds the allowed voltage range.
This may damage the product.
4. Do not short-circuit.
This may damage the product.
5. Do not connect wires to the wrong electrodes.
This may damage the product.
6. Do not apply unreasonable force to the product or bend the product casing.
This may damage or break the product.
Product Components
Model
Components
RN400-H2PS
● RN400-H2PS WiFi Data Logger
● Installation Guide
● 2 Type Cable Glands(PG-9 1EA/ PG11 1EA)
RN400-H2EX
● RN400-H2PS WiFi Data Logger
● Installation Guide
● 2 Type Cable Glands(PG-9 1EA/ PG11 1EA)

1. Product Specifications
RN400 H2
Model Number
RN400-H2PS
RN400-H2EX
Communication
Method
2.4GHz IEEE 802.11 b/g/n
up to WPA2-Enterprise
2.4GHz IEEE 802.11 b/g/n
up to WPA2-Enterprise
Embedded
Sensors/Accuracy
MEMS Sensor CH1:Temp ,CH2:RH
-20~80℃ / ±0.3℃, 5~95 %/±2.0%
MEMS Sensor CH1:Temp ,CH2:RH
-20~80℃ / ±0.3℃, 5~95 %/±2.0%
External Sensor I/F
CH3 : NTC Temp I/F
CH3: TC or PT100 Temp Sensor
CH4: TC or PT100 Temp Sensor
External Sensor
Option (TC-K, PT100)
Door Contact
N/A
Option (Door Magnet Sensor)
CH5: Able / Unable
Dry Contact
N/A
YES, controlled by RN400 Threshold
CH6: On / Off
Buzzer
YES
YES
Screen(color)
OLED 20X2 CHAR (Y or W)
with Timer feature
OLED 20X2 CHAR (Y or W)
with Timer feature
Sensing Interval
1Min, 5Min, 10Min
1Min, 5Min, 10Min
Sending Interval
5Min, 10Min, 30Min
5Min, 10Min, 30Min
Onboard Memory
F-RAM, 32KB
F-RAM, 32KB
External Memory
Option
(16GB microSD, permanent logging)
Option
(16GB microSD, permanent logging)
Water/Dust proof
IP66
IP66
Battery
C Type 1.5V X 2EA OR
C Type 3.6V X 1EA
C Type 1.5V X 2EA OR
C Type 3.6V X 1EA
Battery Lifespan
Over One Years (@10 Min)
Over One Years (@10 Min)
External Power
DC 5~30V
DC 5~30V
UPS
YES(Built In UPS, Operation BAT.)
YES(Built In UPS, Operation BAT.)
Installation Types
Magnet & Screw Hole
Magnet & Screw Hole
Bottom Cable
Glands
Three Holes on the bottom
PG-11 X 2EA / PG-9(Center) X 1EA
Three Holes on the bottom
PG-11 X 2EA / PG-9(Center) X 1EA
Weight
352 g
352 g
Dimension
H100 x W165 x D50 mm
H100 x W165 x D50 mm
* MODEL-S lines are for applications with System Integrator after deleting the Tapaculo365 function.

2. Product Features
● IP66 grade waterproof / dustproof design
● Robust WiFi security
● Built-in UPS (automatic conversion during
blackout)
● Ultra low standby power
● OLED screen, strong in winter
● Tapaculo365 (web storage, reports, alarm)
● Easy installation (supports both magnet and
screws)
● Highly durable F-RAM
● External micro SD memory
● Door Open sensing (EX-model)
● RELAY ON/OFF control (220V 1A, EX model)
● Links to user server (HTTP)
2.1. Power
Actions
Details
Turn On Power
● Once ‘POWER ON’ is pressed, the product shows the model name, firmware
version, power connection type, UPS, basic measurement frequency, basic
transfer frequency, and the name of the connecting WiFi channel.
● When WiFi connection fails:
CONNECT TIMEOUT 25S
!! NO INTERNET !!
Shows WiFi connection failure, and tries
to reconnect to the network
NO WIFI CONNECTION!
PRESS ‘W’ FOR SETUP
If the device continues to fail to connect
to WiFi, press ‘W’ and open the configu-
ration settings.
Shows SOFT AP and ACCESS address for
connection Setup of the product.
(Refer to 4.2. WiFi Settings)
⇩
SOFTAP: _RN400-E2E8
ACCESS: 192.168.1.1
Turn Off Power
● When the device is on ‘WAKEUP’ mode, press ‘POWER OFF ‘[JK1] , which
will show ‘PRESS ‘P’ ONE MORE TO POWER OFF’. Press ’P’ once more
then the device shows ‘POWER OFF! GOOD BYE’ and turns off.
Power Supply
● C Type 1.5V X 2EA OR 3.6V X 1EA
● Batteries should be inserted when connecting to DC power supply for contact
control.
● BUILT-IN UPS: During a DC power blackout, converts automatically to
battery mode(When using DC power supply, batteries are not used.)
Battery Lifespan
● 2 years(when set at 10-min.sensing interval frequency)
Battery Saver
Mode
● The device operates on Battery Saver Mode as the default other than during
data sensing and transfer. Press ‘WAKE UP’ to activate the device to change

settings.
Ex.) Sensing interval 1 min, transfer interval 5 min
● Once the product is activated by pressing ‘WAKE UP’, the last data
transmission time, amount of saved data, name of the connected WiFi
network, and connection signal strength can be checked.
Replace
Batteries
● Low battery warning
1. Shown on RN400 OLED screen
WARNING! | S:menu
Low Battery!
The screen will show ‘WARNING!
LOW BATTERY!’ before showing the
setup screen when the battery is low
once ‘WAKE UP’ is pressed on RN400 in
Battery Saver Mode.
* For general use, Energizer MAX is
recommended.
2. Tapaculo365 web service supports email or SMS alerts to send low
battery warnings.
2.2. Wireless Communication
Actions
Details
WiFi Signal
Strength
(RSSI)
● 0 ~ - 40 dBm : good
● - 40 ~ - 70 dBm : normal
● - 70 ~ - 95 dBm : weak
Lost WiFi
Connection
LOST INTERNET | S:menu
Holding Sample: 230
● When the ‘LOST INTERNET’ message shows after pressing ‘WAKE UP’ on
RN400 in Battery Saver Mode, the amount of data to be transferred will be
shown.
2.3. Memory

Type
Details
Onboard
Memory
●F-RAM
Temporary storage: Saves the data measured at the predefined intervals until
data transmission is made per predefined intervals. Saved data will be
deleted once transmitted.
● When WiFi connection is lost, data will be automatically stored on F-RAM,
and data transmission will be re-attempted every 20 min.
Ex.) Sensing interval 1 min., sending interval 10 min.,
10 data measurements will be sent each transmission
●F-RAM BACKUP SAMPLE SIZE per Model Type
Model
Data Storage Duration
(sensing set at 10min.)
RN400-T2PS(1CH)
27 days
RN400-H2PS(2CH)
18 days
RN400-T2EX(3CH)
11 days
RN400-H2EX(5CH)
7 days
External
Memory
Micro SD Card(16G FAT32, Option)
● Permanent storage: Without the need to configure any settings, insert the
Micro SD card into the slot, and the measured data will be stored under each
date.
* Data storage location: 0-XXXX(last 4 digits of MAC) stored in the order
of>year >month> day
* Example of saved file(measurement every 1 min.)

● May also be used for saving a certificate(CA.PEM) to run the system in a WiFi
enterprise security environment.
- Location of saved certificate: cert/ca.pem
3. Sensors
3.1. H2 Model Onboard Sensors
Type
Spec(Accuracy)
Other Sensor Values
Remarks
MEMS
Temp.-RH
-20~80℃ ( ±0.3℃),
5~95 %(±2.0%)
CH1 : Temp
CH2 : RH
Installed inside the product casing with
membrane filter attached on the front
side
* Membrane filter: Eliminates heavy metals and microorganism contaminants, including ionized virus particles
3.2. Applicable External Sensor Probes
Type
Model
Number
Cable Length/
Diameter
Spec
(Accuracy))
Other Sensor
Values
Size of Sensor Tips
PT100
PR-P1-3
3M / 4.0ø
-200 ~ 300℃
( ± 0.625℃)
-999995.0 :
Sensor not
connected
Diameter: 4.8 ø
Length: 60.0mm
PR-P1-15
15M / 4.0ø
TC-K
PR-K1-3
3M
-20~300℃
( ± 0.8℃)
-999995.0 :
Sensor not
connected
Diameter: 3.0ø
Length: 60.0mm
PR-K1-15
15M
NTC
PR-N1-30
30CM / 4.0ø
-20 ~ 40℃
( ± 1.0℃)
-999995.0 :
Sensor not
connected
Diameter: 6.5 ø
Length: 60.0mm
PR-N1-150
150CM / 4.0ø
DOOR
PR-D1-1
1M
NORMAL
CLOSE
(NC)
99.0 : Open
0.0 : Closed

3.3. External Sensor Calibration
3.3.1. PT100, TC-K Calibrations (Require additional calibration device)
Connect the micro SD port at the Inside the Lower Casing of RN400 to the PC with a USB cable
and calibrate by using Radionode Calibrator software(refer to UA-Calibrations).
3.3.2. NTC Calibration (Require additional calibration device)
1. Activate RN400 by pressing ‘WAKE UP’ while in Battery Saver Mode and press ‘SET UP’ and press
‘ENTER’ after choosing ‘5. CALIBRATE NTC’ from the screen to open the ‘CALIBRATE NTC’ menu.
2. Start calibration by checking the NTC temperature
sensor. The ‘d’ value shows the OFFSET value in mV,
and ‘NTC’ refers to the actual temperature sensor
value.
CAL.NTC |S-W+ P: exit
NTC: -10.0 , d: -20mV
3. When the ‘OFFSET’ value is increased, the actual temperature value goes up. Use ‘SET UP’ (-) and
‘WAKE UP’ (+) on the front of the device to calibrate the sensor value.
4. Once calibration is complete, press ‘POWER’ to save and end the process.
4. How to Use the Product
4.1. Product Exterior and Interior
4.1.1. Front

4.1.2. Side
4.1.3. Inside the Upper Casing
4.1.4. Inside the Lower Casing(PS Model)

ⓐ TEMP NTC
As the NTC temperature sensor does not distinguish ‘+’ and ‘-‘ electrodes, connect freely to the
terminal. The applicable sensor models are: PR-NTC-15CM and PR-NTC-150CM.
ⓑ POWER
When using the contact control function, connect to a DC 5~30V power supply by checking the
‘+’ and‘-‘ electrodes.
* Batteries should be inserted when connecting to a DC power supply for contact control.
* BUILT-IN UPS: During a DC power blackout, converts automatically to battery mode(When using DC
power supply, batteries are not used).

4.2. Connecting to WiFi
Step 1
MANU | W: enter P: exit
2.CONFIG MODE(AP)
Press ‘WAKE UP’ to activate the device and press ‘SET
UP’ twice to move to the ‘CONFIG MODE(AP)’ menu.
SOFTAP: _RN400-E2E8
ACCESS: 192.168.1.1
Enter the mode by pressing ‘WAKE UP(ENTER)’ and
check the SOFT AP and ACCESS address.
Step 2
Proceed with RN400 setup with your smart phone. From the WiFi setting screen of your smart
phone search for ‘WIFI AP’ and select ‘_RN400-E2E8’ as shown on the RN400 device.
Step 3
Run the web browser app on your smart device and input ‘192.168.1.1’ in the address window to
access the site.
Step 4
Select the ‘WIFI’ tab, and from the ‘WIFI SETUP’ window, select the WiFi AP to connect RN400 from
the Access Points list.

Step 5
Select each AP information ‘Access Point Type’ and ‘Personal Security Type’ and input the Security
KEY/PIN.
Step 6
After clicking ‘SAVE’, at the bottom of the device the message will show: ‘Do you want System
Reset?’ When confirmed, the device will reboot and the WIFI AP setting will change.
4.3 WiFi Enterprise Security Connection
To use enterprise-level security, a router AP that supports a RADIUS server and provides enterprise service
is required. A RADIUS server is a server that manages the certification and authority level by user within a
company. A router AP with enterprise support usually comes with an embedded RADIUS server. Thus, to
access the RADIUS server, an ID, PASSWORD, and certificate CA.PEM files should be prepared. Save the
‘ca.pem’ file on the micro SD card under ‘/cert/ca.pem’ and insert the micro SD card into the SD card slot of
RN400 and proceed with AP setup under the CONFIG(AP) menu.
Requirements to Connect to Enterprise Security AP
1. Certificate to access the RADIUS server
When saving the ‘certificate to access the RADIUS server’ on the SD card, the name of the file
should be changed to ‘ca.pem’. The created file shall be stored under the ‘/cert’ folder.
2. ID / PASSWORD for the RADIUS server
If provided with an ID and PASSWORD, input the fields when setting up the AP with a smart
phone.
3. SSID and KEY value for the AP
Input the SSID and KEY values of the enterprise AP to be accessed.

5. Product Configuration
5.1. Access the Configuration Screen
Step 1
MANU | W: enter P: exit
2.CONFIG MODE(AP)
Press ‘WAKE UP’ to activate the device and press ‘SET
UP’ twice to move to the ‘CONFIG MODE(AP)’ menu.
SOFTAP: _RN400-E2E8
ACCESS: 192.168.1.1
Enter into the mode by pressing ‘WAKE UP(ENTER)’
and check the SOFT AP and ACCESS address.
Step 2
Use your smart phone to proceed with RN400 setup. From the
WiFi setup screen of the smart device, search for WIFI AP and
select ‘_RN400-E2E8’ as confirmed from the RN400 device.
Step 3
Run the web browser app on your smart device and input
‘192.168.1.1’ in the address window to access the site.

5.2. System Configuration
Tapaculo365 Owner
Shows the device manager ID for Tapaculo365
owner
MAC
Shows the product MAC
Model Name
Shows model name of product
SW-Version
Shows the currently operating software version
OTA Release Version
Shows the currently operating firmware version
SDCARD Inserted
Micro SD card inserted (yes / no)
WIFI SSID
Shows WiFi SSID
IP Address
Shows the IP address that can change the product
settings
GW Address
Shows the connected gateway

5.3. Server Configuration
5.3.1. When Using Tapaculo365
Destination
Select either Tapaculo365 or User HTTP Server
to set the server to receive the measured data.
* Refer to separate user manual for Tapaculo365.
5.3.1. When Using User HTTP Server
User HTTP Server URL
Host
Enter Host information.
Port
Enter Port information.
Checkin URL
Enter Check-in URL information.
Datain URL
Enter Data-in URL information.
* Refer to ‘HTTP Server Implementation for Connecting to RN400’ for more details.

5.4. Measurement Configuration
SENSOR SETUP
Sensing - Sending Interval
Select a combination of Sensing Interval (1Min,
5Min, 10Min) and Sending Interval (5Min, 10Min,
30Min)
Temperature Scale
Select between ℃ or ℉.
SENSORS
CH Info
Information of the sensors by channel currently
operated by the RN400 model
5.5. WiFi Configuration
5.5.1. When Using Personal Type
Access Point
Select the name of the desired wireless
connection.
SSID
Show the selected wireless connection.
Security Type
Select between ‘Personal’ and ‘Enterprise‘.
Personal Security Type
Select the network authentication method: OPEN,
WEP, WPA/WPA2.
Security KEY/PIN
Input the password.
Static IP
Select the appropriate Dynamic IP or Static IP.

5.5.2. When Using Enterprise Type
Enterprise Security Type
Select the relevant Enterprise Security Type.
RADIUS User ID
Input the User ID for authenticating a registered
user.
RADIUS User Password
Input the Password for authenticating a registered
user
5.6 Other Settings(Time Zone, Screen Display Setting)
Time Zone Configuration
Select the time zone as per the location of the
device.
Display Time OP Mode
Setup the OLED screen to show the sensor value
for a given duration at the pre-fixed time.
Ex.) ‘Show the sensor value on the screen for 30
mins from 08:00’
Setup the start time to display the sensor value on
the OLED screen (Display Timer Start Time: 08:00)
and time for display duration (Display Timer OP
Mode: 30Min).

6. Screen Operations
The buttons on the front of RN400 can be used for many operations, such as checking the information
on RN400.
6.1 Check Sensor Value, Time of Sensing and Transfer
After turning on RN400 by pressing ‘POWER’ on the front, or activating the device by pressing ‘W’ while
RN400 is in Battery Saver Mode, the OLED screen displays the sensor values, time of sensing and data
transfer.
SENSOR DATA | S:menu
1: 10.00 | 2: 20.00
Sensor Data
The RN400 Channel 1 and 2 values are displayed on the OLED
screen.
SENSOR DATA | S:menu
3: 00.00
Sensor Data
The RN400 Channel 3 value is displayed on the OLED screen.
LAST TRANSMIT | S:menu
1 Min Ago, 9 Samples
Data Transfer
Shows time elapsed from the last data transmission, and the
amount of sample data stored for the next transmission.
WIFI SSID, dB | S:menu
dekist, -50dB
Wireless Connection Signal Strength
Shows the connected WiFi network name and the signal strength.
6.2 RN400 Information and Function
After turning on RN400 by pressing ‘POWER’ on the front, or activating the device by pressing ‘W’ while
RN400 is in Battery Saver Mode, press ‘S’ to display the product information, setup mode, firmware
update, reset mode, calibration mode menu on the OLED screen.
MENU | W: enter, P: exit
1.VIEW INFO
1) HOLDING DATA
(Until data transmission) amount of data stored for transmit.
2) POWER
Shows current power supply type (External DC/Battery)
⇩
INFO | S:next, P:exit
1.HOLDING DATA : 1
INFO | S:next, P:exit
2.POWER : External DC

INFO | S:next, P:exit
3.SENSING : 1 Min
INFO | S:next, P:exit
4.SENDING : 10 Min
INFO | S:next, P:exit
5.UPDATE : 1 Min Ago
INFO | S:next, P:exit
6.ID : DEKIST
INFO | S:next, P:exit
7.IP : 192.168.10.13
INFO | S:next, P:exit
8.GW : 192.168.1.1
INFO | S:next, P:exit
9.MAC:9884E3E5E28
INFO | S:next, P:exit
10.SW BUILD : 20171022
INFO | S:next, P:exit
11.OTA VER : VER00
3) SENSING
Shows the setup data sensing interval(1Min, 5Min, 10Min.
4) SENDING
Shows the setup data transmission interval (1Min, 5Min, 10Min,
30Min.
5) UADATE
Shows the last data transmission time.
6) ID
Shows the ID managed by Tapaculo365.
7) IP : 192.168.10.13
Shows the IP address.
8) GW : 192.168.1.1
Shows the gateway address.
9) MAC
Shows the MAC address.
10) SW BUILD : 20170913
Shows the date of the last firmware update.
11) OTA VER : Ver00
Shows the firmware version.
MENU | W: enter, P: exit
2.CONFIG MODE(AP)
Configuration Mode
Shows the SOFT AP and ACCESS address to change the
RN400 settings with a smart device(Refer to ‘7.2 WiFi
Connections’ to access configuration mode).
⇩

SOFTAP: _RN400-7E1F
ACCESS:192.168.1.1
MENU | W: enter, P: exit
3.FIRMWARE-UPGRADE
Firmware Update Mode
Connects to the firmware update mode and starts the firmware
update.
⇩
FIRMWARE IS UPDATING
NOW….
DOWNLOAD COMPLETED
DEVICE WILL BE RESET
Firmware download in progress.
Firmware download completed.
MENU | W: enter, P: exit
4.FACTORY-RESET
Reset Mode
Resets the information and setting of RN400.
⇩
INFO.
Factory Default OK!
MENU | W: enter, P: exit
6.CHECK SYSTEM
Check System Mode
When registering a channel to Tapaculo365, this is used to check
the connection between the device and server. Check the data
value displayed on the RN400 screen every 3 seconds, and
check if the data is correctly updated every 3 seconds on the
device from Tapaculo365.
⇩
CHK.SYSTEM |W.P:exit
TEMP: 24.80
7. RN400-H2EX Additional Functions
This manual suits for next models
1
Table of contents
Other Radionode Data Logger manuals
Popular Data Logger manuals by other brands

Plum
Plum MacR6 N installation manual

MadgeTech
MadgeTech Bridge120 Series Product Information Card

Capetti Elettronica
Capetti Elettronica WineCap WSD12T-CO user manual

Sutron
Sutron Xpert2 Operation and maintenance manual

Hioki
Hioki HiLogger 3145-20 instruction manual

Ijinus
Ijinus LOG03V3-3G installation guide