Radionode RN400-T2TS User manual

User Manual
IoT Temp Data Logger
RN400-T2TS
Keep this document nearby so that it may be referred to when needed.2021 | Rev. 1

02
Introduction Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
CONTENTS
About this Manual 04
Intellectual Property Rights 04
Notational Conventions 04
Introduction 05
Key Features 05
Exterior 06
Accessories 07
Specifications 08
Installation 09
Terminal Block 10
Data Logger Installation 11
Connecting Terminal Block 13
Operation 17
Viewing Channel Information 18
Viewing Device Information 19
Resetting Data Logger 20
Memory Card for Data Logging 21
Configuration 22
Device Information 24
Server 25
Measurement 26
Wi-Fi Network 28
Display 31
Commands 31
Memory Card Usage Configuration 32
Checking Communication With Tapaculo 365 Server 33

03
Introduction Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Tapaculo 365 34
Adding Devices from Your Smartphone 35
Adding Devices from Your Computer 38
Maintenance 41
Cleaning 41
Batteries 41
Firmware Update 42
Customer Service Information 43
Manufacturer Contact Information 43
Warranty 43
Limit of Liability 43
Certifications 44
HTTP Radionode Protocol V2 45
Check-in 45
Data-in 48
Order List 49
Data Logger 49
Accessories 50

04
Introduction Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order List
About
this
Manual
This document contains instructions for usage and installation of
the RADIONODE®RN400-T2TS. Product specifications and certain
features herein may be subject to change without prior notice.
Figures used in this manual are for explanatory purposes only, and
may differ from your system depending on installation conditions.
Software screenshots may change after software updates.
Intellectual
Property
Rights
© 2021 DEKIST Co., Ltd.
All contents and figures herein are property of DEKIST Co., Ltd.
Reproduction or redistribution of all or part of this document in any
way is not permitted without prior consent from DEKIST.
Notational
Conventions
Failure to follow instructions marked with "Warning" may
result in slight injury to the user.
Failure to follow instructions marked with "Caution" may
result in equipment damage or malfunction.
Additional helpful information is marked with "Note".
About this Manual

05
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Introduction
The RADIONODE RN400-T2TS Data Logger periodically measures
temperature and RH, then sends measurement data to the Tapaculo®
365 server. The RN400-T2TS has a total of 4 I/O channels.
Channel 1 External Temp
sensor Channel 2 External Temp
sensor
Channel 3 External Temp
Sensor Channel4 External Temp
sensor
Key Features Key features of the RN400-T2TS include:
SW
POWER
ON/OFF
5BQBDVMPm
●Data Logger can be used with additional temp sensors.
●Use Wi-Fi connection to easily configure your Data Logger.
●Built-in buzzer that activates alarm when measurement is
outside the margin of error.
●Measurement data can be viewed remotely from Tapaculo 365
website. See Tapaculo 365 on page 34.
●Measurement data can be logged on a micro SD card.
Introduction

06
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Exterior
SW POWER
ON/OFF
2
3
4
1
5
❶ Display
❹ Power button
❷ Menu button
❺ Cable gland
❸ Display button
Power cables and cables of other devices, such as external sensors,
are connected via cable glands to the internal terminal block.
For instructions on how to use the buttons, see Operation on page
17.
Introduction

07
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Accessories All accessories, except for cable glands, are sold separately.
TC-K Temp Sensor
1.5 V Battery × 2
Cable Gland
3.6 V Battery DC Adapter (12 V, 500 mA)
TC-T Temp Sensor
In the event of power failure, two C-type 1.5 V batteries or one 3.6 V
battery must be placed in the Data Logger. RADIONODE Data Logger
is designed to not operate without a battery, even when external
power is connected.Use the same type of external temperature
sensor for one device. Type K Thermocouple (TC-K) and Type T
Thermocouple (TC-T) Sensor cannot be used together.
SW POWER
ON/OFF
5$,5$,
SW POWER
ON/OFF
5$5 5$5
SW POWER
ON/OFF
5$, 5$5
In the event of power failure, two C-type 1.5 V batteries or one 3.6 V
battery must be placed in the Data Logger. RADIONODE Data Logger
is designed to not operate without a battery, even when external
power is connected.
Only use Energizer®batteries. The Data Logger’s power
consumption varies significantly depending on operation
functions. Only Energizer batteries can keep performance
stable despite extreme battery usage fluctuations.
Introduction

08
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Specifications
SW
POWER
ON/OFF
165 mm
50 mm
100 mm
115 mm
RN400-T2TS Data Logger
External Temp
Sensor
Ch.1 TC- K/J/T/N/S/E/B/R
Ch.2 TC- K/J/T/N/S/E/B/R
Ch.3 TC- K/J/T/N/S/E/B/R
Ch.4 TC- K/J/T/N/S/E/B/R
Communication
2.4 GHz IEEE 802.11 b/g/n
WPA2-Enterprise
HTTP Get/Post
RS485 MODBUS RTU
Cable Gland PG-9
Water Resistance
Rating IP65 (IP67 is optional)
External DC power 5 - 30 V
Size 165 × 50 × 115mm
Operating conditions
-20 ~ 60 °C, 0 ~ 95% RH (non-condensed)
Note that the performance of the external temperature
sensor separately may differ from when it is connected
to the Data Logger.
Introduction

09
Installation Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual
Specifications
TC-K Temp Sensor
M. Range -20 ~ 300 °C (accuracy: ±0.8 °C)
Cable 3 m or 15 m
Size 55 mm, ⌀3.0
TC-T Temp Sensor
M. Range -100 ~ 200 °C (accuracy: ±0.8 °C)
Cable 3 m or 15 m
Size 55 mm, ⌀3.0
Note that the performance of the external temperature
sensor separately may differ from when it is connected
to the Data Logger.
Introduction

10
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
Installation
The following procedure will guide from the installation procedure to
the Tapaculo 365 registration process.
1. Install sensors or connect other devices to the Data Logger as
needed.
2. Connect power and insert the battery.
3. Use the virtual Wi-Fi router feature to configure the Data Logger.
See Configuration on page 22.
4. Now that the Data Logger has been installed, it must be registered
to Tapaculo 365. See Tapaculo 365 on page 34.
Depending on your installation circumstances and conditions, your
installation process may vary. For example, if you are installing
multiple Data Loggers, you might find it easier to:
1. Insert batteries into all Data Loggers before running.
2. Configure one Data Logger first.
3. Use a micro SD card to set up additional Data Loggers. For this
method, see Memory Card Usage Configuration on page 32.
4. Register the Data Loggers onto Tapaculo 365.
5. Finally, install the Data Loggers.

11
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
Terminal
Block
Terminal Blocks can be found inside of a Data Logger, with other
components arranged as follows:
5 63 4 8
7
9
1 2 2
❶ Micro SD Card Slot
❹
FPC / FFC Connection
❼
RS485 OUTPUT
❷ Battery Holder
❺
USB for
Calibration
❽ DC
POWER(5~30V)
❸ OLED Connection
❻ 4-20mA INPUT
❾ Select Battery
Type
Micro SD card is used to log measurement data. See Memory Card
for Data Logging on page 21.
The micro USB port is used for sensor calibration. As RN400 Series
sensors are shipped after calibration, no further calibration is
required. However, if the sensor malfunctions, contact DEKIST for
inspection.
For more information on the terminal block, see Connecting
Terminal Block on page 14.

12
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
Data Logger
Installation
The general procedure for installing a Data Logger is as follows:
1. Loosen the screw on the right side of the front panel and open
the front panel.
SW
POWER
ON/OFF
2. Loosen the cable gland.
3. Route the cables of the device that will be connected through the
gland and connect to the terminal block. Then, connect external
DC power and insert the battery. For more information on terminal
block connection, see Connecting Terminal Block on page 14.

13
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
4. Tighten the gland firmly.
5. Cover the front panel and tighten the screws.
SW
POWER
ON/OFF
6. There Data Logger is equipped with a magnet at the rear. Place
the Data Logger on a steel panel.
If necessary, use screws to secure. There are three screw holes on
the back of the device.

14
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
Connecting
Terminal
Block
When connecting cables to the terminal block, ensure
that the flat cable does not get disconnected from the
front connector.
Cable Gland If Data Logger cable gland cannot sufficiently receive all cables,
install additional cable glands. There are two more gland slots at the
bottom of the Data Logger.
1. Loosen and remove the cap bolt from the left or right gland slot.
2. Insert the cable gland into the nut and tighten.

15
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
TC Temp
Sensor
Connect Thermocouple cable to Temp.Ch1~CH4 Terminal terminal.
Connect the red cable to the A(+) terminal, and the remaining cables
to the B(-) terminal.
+-
POWER
5~30V
RS485TEMP
1CH
TEMP
1CH
TEMP
1CH
TEMP
1CH
KT JE
Install the external temperature sensor away from the
wall and the floor. The sensor may not touch anything
other than the ambient air.
DC Power Connect the Power cable to the POWER terminal. Connect the red
cable to the +terminal, and the remaining cables to the -terminal.
A(+) B(-)
TEMP
CH1
b A(+) B(-) b
TEMP
CH2
A(+) B(-)
DOOR
CONTACT
A(+) B(-)
LOAD
220V 1A
+-
POWER
5~30V

16
Introduction Operation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Installation
Batteries Insert two C-type 1.5 V batteries into the battery holder, or one 3.6 V
battery into the left-hand battery holder.
Be careful not to connect batteries with opposite
polarities. Doing so may damage the device.
If you are using a 3.6 V battery, move the BAT jumper to the B
position.
A
BAT
1.5V x 2
3.6V x 1
B

17
Introduction Installation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Operation
Operation
When the data logger is turned on, the model number and other key
information is displayed with the corresponding measurements. If
no external power is supplied, the display will turn off shortly and the
Data Logger will enter sleep mode.
SW POWER
ON/OFF
●Viewing Channel Information: To view channel information,
including measurements on sleep mode, press the button.
Press the button repeatedly to display different status
information.
●Selecting a Menu: Press the button, then press the button.
Press the button repeatedly to display different menu items.
Press the button to open the displayed menu. Press the
button to exit the menu.
●Turning Data Logger Off: Press the button and hold the
button until PRESS 'P' ONE MORE TO POWER IT OFFPRESS 'P' ONE MORE TO POWER IT OFF
appears. Hold the button again.
●Turning Data Logger On: Press the button.

18
Introduction Installation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Operation
Viewing
Channel
Information
Press the button repeatedly to display the below channel data. A
sensor channel that is not connected will appear as (none)(none).
LAST SENSING |S:menuLAST SENSING |S:menu
1: 26.2C |2: 21.6%1: 26.2C |2: 21.6%
Measurements of Channels
1 and 2
Measurements of Channels
3 and 4
LAST TRANSMIT|S:menuLAST TRANSMIT|S:menu
5 Min Ago, 9 smpl5 Min Ago, 9 smpl
Elapsed time since last
transfer of measurement
data to the server &
number of datasets to
transfer in the next cycle
WIFI SSID dB|S:menuWIFI SSID dB|S:menu
xxxxxxxx, -50dBxxxxxxxx, -50dB
Wi-Fi network name and
signal strength
LOCAL TIME |S:menuLOCAL TIME |S:menu
2020-11-30 17:002020-11-30 17:00
Current date and time
BATTERY STAT.|S:menuBATTERY STAT.|S:menu
OK. |1.5Vx2|2.88VOK. |1.5Vx2|2.88V
Type of battery inserted
and current voltage. If the
voltage is low, LOWLOW will be
displayed.
DATA FILTER.|S:menuDATA FILTER.|S:menu
SLOW LEVEL (1-15):1SLOW LEVEL (1-15):1
You can select the level
of the digital filter. The
higher the number, the less
sensitive the sensor reacts
(1 level: highest sensitive,
15 level: lowest sensitive).
You can choose from the
settings menu.
GS CELL TEMP.|S:menuGS CELL TEMP.|S:menu
CELL Temp: 22 CCELL Temp: 22 C
[ONLY RN400-T2GS] Displays
the temperature value of
the chemical cell inside the
product.
LAST SENSING |S:menuLAST SENSING |S:menu
3: 24.7C |4: (none)3: 24.7C |4: (none)

19
Introduction Installation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Operation
Viewing
Device
Information
To view device information, select 1.VIEW INFO1.VIEW INFO. To view the next
item, press the button. To exit, press the button.
INFO|S:next, P:exitINFO|S:next, P:exit
1.HOLDING DATA: 41.HOLDING DATA: 4
Number of datasets to send
to the server in the next
cycle.
(number of datasets to send = Transfer Interval ÷ Measurement
Interval)
When measurement interval is set to 5 minutes and the transfer
interval set to 20 minutes, 4 datasets are saved until the
next transfer. If data transfer fails, datasets accumulate until
successful.
INFO|S:next, P:exitINFO|S:next, P:exit
2.POWER: External DC2.POWER: External DC
If no external power is
connected or power failure
occurs, BatBat will appear.
INFO|S:next, P:exitINFO|S:next, P:exit
3.SENSING: 1 Min3.SENSING: 1 Min
Measurement interval
INFO|S:next, P:exitINFO|S:next, P:exit
4.SENDING: 5 Min4.SENDING: 5 Min
Measurement data
transmission to server
interval
INFO|S:next, P:exitINFO|S:next, P:exit
5.UPDATE: 1 Min Ago5.UPDATE: 1 Min Ago
Time elapsed since
last transmission of
measurement data to
server
INFO|S:next, P:exitINFO|S:next, P:exit
6.ID: xxxxxxxx6.ID: xxxxxxxx
Tapaculo 365 account ID
INFO|S:next, P:exitINFO|S:next, P:exit
7.IP:192.168.10.137.IP:192.168.10.13
Data Logger IP Address
INFO|S:next, P:exitINFO|S:next, P:exit
8.GW:192.168.1.18.GW:192.168.1.1
Gateway IP address

20
Introduction Installation Configuration Tapaculo 365 Maintenance Customer Service
Information
HTTP Radionode
Protocol V2 Order ListAbout this Manual Operation
INFO|S:next, P:exitINFO|S:next, P:exit
9.DN:210.220.163.829.DN:210.220.163.82
DNS server IP address
INFO|S:next, P:exitINFO|S:next, P:exit
10.MAC:508CB16FA1B310.MAC:508CB16FA1B3
Data Logger MAC address
INFO|S:next, P:exitINFO|S:next, P:exit
11.SW BUILD:2020072011.SW BUILD:20200720
Firmware version
INFO|S:next, P:exitINFO|S:next, P:exit
12.MODEL:RN400T2TS12.MODEL:RN400T2TS
Model No.
INFO|S:next, P:exitINFO|S:next, P:exit
13.ALARM:OFF (BAT.)13.ALARM:OFF (BAT.)
Alarm relay status
INFO|S:next, P:exitINFO|S:next, P:exit
14.EX-SENSOR: TC-K14.EX-SENSOR: TC-K
Type of external sensor
installed
Resetting
Data Logger
All setting options (except for Wi-Fi network) can be reset. Select
4.FACTORY DEFAULT4.FACTORY DEFAULT.
Table of contents
Other Radionode Data Logger manuals
Popular Data Logger manuals by other brands

Plum
Plum MacR6 N installation manual

MadgeTech
MadgeTech Bridge120 Series Product Information Card

Capetti Elettronica
Capetti Elettronica WineCap WSD12T-CO user manual

Sutron
Sutron Xpert2 Operation and maintenance manual

Hioki
Hioki HiLogger 3145-20 instruction manual

Ijinus
Ijinus LOG03V3-3G installation guide