RAIS/attika NEXO Series User manual

1
POSITIV
OUTLINE
NEGATIV
NEXO GAS
GB
UK

2
Produced at:
RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark
Hergestellt für /Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn
CE Label:
NEXO GAS Modeller
19
C11
C31
C91
0359/
This appliance must be installed in accordance with the rules in force, and only used in
a suffidebtly ventilated space. Consult instructions before installation and use of this
appliance. Tested and Certified for use on Biopropane.
Efficiency class 1
N
A
T
U
R
A
L
P
R
O
P
A
N
E
GAS CATEGORY and SUPPLY PRESSURE
I2H
I2E
I2E+
I2ELL
I2L I2EK
I2 (43.46 -45.3 MJ/m3
(0°C))
I3+
I3P(30)
I3P(37)
I3P(50)
I3B/P(30)
I3B/P(50)
HEAT
INPUT
(Gross, KW)
BURNER
PRESSURE
(Hot, mbar)
COUNTRY
of DESTINATION
G20 @ 20 mbar
G20 @ 20 mbar
G20↔G25 @
20↔25 mbar
G25 @ 20 mbar
G20/G25.3 @
25 mbar
G30↔G31 @
28↔37 mbar
G31 @ 30 mbar
G31 @ 37 mbar
G31 @ 50 mbar
G30↔G31 @
30 mbar
G30↔G31 @
50 mbar
9,1
9,1
9.1/8.4
7,5
8,5
8
7
8
8
8
836
27
36
36
28
27/36
16.6
13.4
13.2/16.4
13,2
13,2 AT, BG, CH, CZ, DK, EE, ES, FI,
GB, GR, HR, IE, IT, LT, LV, NO,
PT, RO, SE, SI, SK, TR
DE, LU, PL, RO
BE, FR
DE
NL
BE, CH, CY, CZ, ES, FR,
GB, GR, IE, IT, LT, PT, SI,
SK, TR
FI, NL, RO
BE, CH, CZ, ES, FR, GB,
GR, HR, IE, IT, LT, NL, PL,
PT, SL, SK, TR
AT, CH, CZ, DE, NL, SK
BE, BG, CY, DK, EE, FI, FR, GB,
GR, HR, HU, IT, LT, MT, NL, NO,
RO, SE, SI, SK, TR
AT, CH, CZ, DE, FR, SK
NEXO 100 Gas / NEXO 100 G Gas / NEXO 100 Classic Gas / NEXO 100 G Classic Gas
NEXO 120 Gas / NEXO 120 G Gas / NEXO 120 Classic Gas / NEXO 120 G Classic Gas
NEXO 140 Gas / NEXO 140 G Gas / NEXO 140 Classic Gas / NEXO 140 G Classic Gas
NEXO 160 Gas / NEXO 160 G Gas / NEXO 160 Classic Gas / NEXO 160 G Classic Gas
NEXO 185 Gas / NEXO 185 G Gas / NEXO 185 Classic Gas / NEXO 185 G Classic Gas
CITY GAS G150.1 @ 8 mbar 6
9,4 DK, SE
Product ID: 0359CS1717
Mærkeplade/Typenschild/Manufacturer’s plate/Plaque signalétique/
Merkeplate/Märkplät/ Tyyppikilpi
UK

This stove had been tested and certicated for several countries (see the rating
plate). It may be necessary to adjust the stove for safe and correct use in your coun-
try/area.
This stove has been tested and certicated for use with natural gas, LPG and bio-
propane.
Biopropane can be used if the stove is adjusted for use with LPG (liquid petroleum
gas), see rating plate under PROPANE.
This manual covers the following models:
NEXO 100 Gas – without side glass
NEXO 100 G Gas – with side glass
NEXO 100 Classic Gas – without side glass
NEXO 100 G Classic Gas – with side glass
NEXO 120 Gas – without side glass
NEXO 120 G Gas – with side glass
NEXO 120 Classic Gas – without side glass
NEXO 120 G Classic Gas – with side glass
NEXO 140 Gas – without side glass
NEXO 140 G Gas – with side glass
NEXO 140 Classic Gas – without side glass
NEXO 140 G Classic Gas – with side glass
NEXO 160 Gas – without side glass
NEXO 160 G Gas – with side glass
NEXO 160 Classic Gas – without side glass
NEXO 160 G Classic Gas – with side glass
NEXO 185 Gas – without side glass
NEXO 185 G Gas – with side glass
NEXO 185 Classic Gas – without side glass
NEXO 185 G Classic Gas – with side glass
The stove is HOT during operation. Wear gloves when opera-
ting the stove. Do not operate the stove with an open door,
damaged glass, worn or damaged seals. Caution there might
be sharp edges.
UK

4
10-6510 - NEXO GAS
0
01-04-2019
Revision :
Date :
INTRODUCTION.................................................................................................................5
GUARANTEE...........................................................................................................................6
SPECIFICATIONS .....................................................................................................................7
DISTANCE/TEMPLATE..............................................................................................................7
GENERAL
GENERAL REMARKS ...............................................................................................................8
EMERGENCY INTERRUPTION OF GAS SUPPLY .........................................................................9
INSTALLATION OF STOVE
INSTALLATION ......................................................................................................................10
GAS CONNECTION...............................................................................................................10
VENTILATION ........................................................................................................................10
GAS INSTALLATION...............................................................................................................10
CHANGING THE CHIMNEY CONNECTION.............................................................................11
CONVERSION TO BOTTLED GAS (LPG) ..................................................................................14
NORMAL INSTALLATION - RECTANGULAR WITHOUT SIDE GLASS .........................................21
NORMAL INSTALLATION - RECTANGULAR WITHOUT SIDE GLASS .........................................22
CORNER INSTALLATION 45° WITHOUT SIDE GLASS...............................................................23
CORNER INSTALLATION 45° WITH SIDE GLASS .....................................................................24
INSTALLATION SPACING FOR NON-FLAMMABLE WALL .........................................................25
CHIMNEY/VENT....................................................................................................................26
LOCATION OF CHIMNEY TERMINALS....................................................................................27
HORIZONTAL WALL TERMINAL TYPE C11 .............................................................................28
VERTICAL ROOF TERMINAL C31 ...........................................................................................29
ASSEMBLY OF SECONDARY BURNER ....................................................................................30
Arrangement of ”Embers” and ”Logs”.................................................................................31
START-UP
BATTERIES ............................................................................................................................36
SETTING UP THE ELECTRONIC CODE ....................................................................................38
COMMISSIONING.................................................................................................................39
INITIAL IGNITION ..................................................................................................................41
USER INSTRUCTIONS
REMOTE CONTROL...............................................................................................................42
USING STOVE WITHOUT REMOTE CONTROL ........................................................................48
SERVICE
SERVICE ...............................................................................................................................50
CLEANING............................................................................................................................51
ACCESSORIES.......................................................................................................................52
MYFIRE WI-FI BOX ................................................................................................................53
SPARE PART LIST VIVA 100 L GAS - VIVA 120 L GAS - VIVA 160 L GAS .................................55
SPARE PART LIST VIVA 100 L G GAS - VIVA 120 L G GAS - VIVA 160 L G GAS ......................56
SPARE PART LIST GAS UNIT...................................................................................................57
TECHNICAL INFORMATION
TECHNICAL INFORMATION ...................................................................................................58
TECHNICAL DATA.................................................................................................................60
EXAMPLES OF CHIMNEY SOLUTIONS....................................................................................62
CHIMNEY COMPONENTS .....................................................................................................71
DECLARATION OF PERFORMANCE........................................................................................75
Reservations for printing errors.
UK

Dealer: Date:
Introduction
Congratulation on your new RAIS / attika Product.
A RAIS/
attika
stove is more than just a source of heat, it also express-
es how you put the emphasis on good design and high quality in your
home.
In order get the most pleasure and benefit from your new stove, it is
important that you read the manual thoroughly before it is installed and
put to use.
For the purpose of the guarantee and all contact regarding the stove in
general, it is important that you can state the stove's production number.
We therefore recommend that you write down the number in the form
below.
The production number can be found at the bottom on the back of the
stove.
Installer: Date:
UK

6
Guarantee
RAIS/
attika
stoves are checked several times with regard to safety, as
well as the quality of materials and manufacturing. We offer a 2 year
guarantee on all models and the guarantee commences on the date of
installation. However only 1 year on wear parts such as thermosensors
ect.
The guarantee covers:
• documented functional faults due to incorrect manufacture
• documented material faults
The guarantee does not cover:
• door and glass gaskets
• ceramic glass
• the appearance of the surface structure or texture of the natural
stone
• the appearance of the stainless steel and colour changes and patina
• expansion blemishes
• batteries
The guarantee is invalidated in the event of:
• damage due to overfiring
• damage due to external influences and the use of unsuitable fuels
• failure to comply with statutory or recommended installation instruc-
tions and in the event the user's own modifications of the stove.
• lack of servicing and care, the stove must be serviced annually
In the event of damage, please contact your dealer. In the event of
claims under the guarantee, we will decide how the damage is to be
repaired. In the event of repairs, we will ensure they are performed pro-
fessionally.
In the event of guarantee claims concerning repaired parts or parts
delivered later, please refer to national/EU law/provisions in relation to
renewed guarantee periods.
The guarantee provisions applying at any time may be requested from
RAIS/
attika
.
UK

7
Specifications
Intertek Ref.:
102929617LHD-001
NEXO 100 NEXO 120 NEXO 140 NEXO 160 NEXO 185
Nominal heat input (kW):
Natural Gas - G20 I2H/I2E 9.1 9.1 9.1 9.1 9.1
Min/Max input (kW):
Natural Gas - G20 I2H/I2E 1.7 - 9.1 1.7 - 1.9 1.7 - 1.9 1.7 - 1.9 1.7 - 1.9
Nominal heat input (kW):
Propane Gas - G30/G31
I3B/P(30)
8 8 8 8 8
Min/Max input (kW):
Propane Gas - G30/G31
I3B/P(30)
1.8 - 8 1.8 - 8 1.8 - 8 1.8 - 8 1.8 - 8
Heating area (m2at -20°): Approx.
180
Approx.
180
Approx.
180
Approx.
180
Approx.
180
Stove width/depth/height
(mm):
446-398-
1025
446-398-
1235
446-398-
1426
446-398-
1601
446-398-
1861
Weight (kg) min., depending
on model:
approx.
125
approx.
140
approx.
156
approx.
166
approx.
190
Efficiency (%): (G20 I2H/I2E) 91 91 91 91 91
CO content (PPM) (G20 I2H/
I2E) 31 31 31 31 31
NOx emissions (G20 I2H/I2E) 23 23 23 23 23
Intertek Testing & Certification Ltd,
Registered office: Academy Place, 1 to 9 Brook Street, Brentwood, Essex
CM14 5NQ, United Kingdom. Registered No: 3272281
(England), VAT No: GB 672-7639-96-011
T: +44 1277 223 400
F: +44 1277 223 127
Maximum Output Natural Gas Net (kW)
Gas type G20
6,4
Maximum Output Propane Net (kW)
Gas type G31
5,8
UK

8
General Comments
This RAIS/
attika
product is an extremely effective convection gas stove
with a sealed combustion chamber for chimneys with a balanced draught.
It is fitted with a burner with the latest burner technology. It has a var-
iable heat output because it uses a special control system that makes it
possible to use three burners for high output or one burner for a lower
output. One of the burners, called the "Main burner" is located in the
centre of the stove, the second and third burners, called the "Secondary
burners" are located behind the Main burner. The secondary burners can
be switched on and off while the stove is on.
Where there is a natural gas connection, the local gas supply conditions
should be investigated to ensure that the gas composition and pressure
suit the stove's settings.
If the stove is connected to bottled gas, only gas bottles fitted with a gas
regulator (Low pressure regulator) providing the correct gas pressure may
be connected. For this reason, gas bottles without a regulator must not
be connected.
This stove must only be installed, set up and serviced by a Gas safe reg-
istered Engineer. The installation must comply with local and national
Building Regulations and Gas Regulations and the user manual must
be adhered to. The user manual should be left with the customer, who
should keep this for later use. The manual is necessary when the stove is
to be serviced.
Ensure that the chimney terminal is not blocked in any way and is free of
vegetation in the form of trees, bushes etc. and that objects are not rest-
ing against the chimney's terminal or the protection around the terminal.
The door glass should always be cleaned before the stove is turned on
and fingerprints wiped as these can be burned into the glass.
The stove must not be used if the door glass is split, cracked, re-
moved or if the door is open. Do not use the stove if the door
gasket is broken or worn.
General
UK

9
UK
This stove is designed for use in many different installation situations,
which can be seen in this manual. Only chimneys approved by RAIS/
at-
tika
may be used with this product. (see chimney section)
This stove is intended for chimneys with balanced draughts (Air intake
and draught in same chimney) so there is no need for any extra air sup-
ply for combustion.
This product is a heating appliance so the surfaces become very
hot and should not be touched during use. It is therefore recom-
mended that you use an approved stove screen to protect chil-
dren, vulnerable adults, older people and persons with reduced
mobility in the same area as the stove.
Keep curtains, washing, furniture etc. at a minimum distance of 300 mm
from this stove.
The stove must not be used for burning waste.
If the stove is extinguished or goes out, do not attempt to turn it back
on until a minimum of 3 minutes have passed.

10
Emergency interruption of gas supply
Where a smell of gas is detected, the gas supply must be interrupted
immediately. Turn off the stove at the isolation tap and the gas meter
Ventilate the room by opening windows and doors, do not use electrical
appliances in the vicinity of the stove. Or operate any electrical switches.
The gas supply must not be switch on, until a Gas Safe Registered engi-
neer has checked the system and deem it as being safe.
UK

11
UK
Installation
It is important that the stove is correctly installed from both an environ-
mental and safety point of view.
The stove must only be installed by a Gas Safe Registered engineer.
When installing the stove, all local rules and regulations, including those
referring to national and European standards must be complied with.
The installation must comlpy with the Building Regulations and Gas Safe-
ty (Installation and use) Regulation.
There must be no unauthorised modifications of the stove.
Before installation begins, it should be confirmed that the information
on the data plate regarding gas type and pressure is in accordance with
the local gas supply conditions under which the stove is to be installed.
You should ensure that the gas supply can supply the required quantity
of gas and pressure as described on the data plate. It is advisable to wear
gloves when installing and servicing the stove.
Gas connection
The inlet supply pipe has an external diameter of Ø8mm. An isolation
tap must be fitted.
Ventilation
This stove has a sealed combustion chamber and is intended for a bal-
anced draught. There is therefore no need for an extra air supply.
It is recommended that sufficient fresh air is supplied to the room to
maintain a comfortable environment.
This stove may be installed in a completely airtight building or a building
with mechanical ventilation.
installation of stove

12
UK
Gas installation
Once it has been decided where the stove will be positioned, a gas in-
stallation should be established in the vicinity of the stove so that the gas
supply and stove can be connected.
As this stove has a sealed combustion chamber and a built-in plinth,
there is no need for a floor slab.
The installation must comply with the Building Regulations, Gas Safe-
ty (Installation & USe) Regulations, BS 5871, BS 5440-1, BS 6891 and
where relevant all LPG Codes of Practice. LPG stoves must not be fitted
in a basement.

13
PLEASE NOTE!
The floor construction must be able to bear the weight of the stove and
chimney, if applicable. If the existing design does not satisfy this prereq-
uisite, suitable measures must be taken (e.g., a load distribution slab).
Consult a construction expert.
The stove must be positioned at a safe distance from flammable materi-
al.
It must be ensured that flammable objects (e.g., furniture) are not po-
sitioned closer than the distances stated in the following sections with
regard to installation (risk of fire).
When you choose where you wish to position your stove, you should
consider the heat distribution to the other rooms. Then you will get the
maximum possible pleasure from your stove.
Inspect the stove for defects upon receipt.
Changes to chimney connection
The stove is supplied ready for a top outlet but can be changed to a
rear outlet in the following manner:
Illustrations
1. The knock-out blank at the rear of the stove
can be knocked out using a hammer. This may
require several blows. Be careful to only hit the
blank.
UK

14
2. Loosen the three screws
on the outer flange on the
top surface of the stove.
And remove it.
5. Loosen the three screws on
the inner flange on the bot-
tom surface of the stove. And
remove it.
4. Unscrew the outer cover
plate at the rear of the stove
and move it to the upper sur-
face of the stove.
3. To open the door, a 14mm open-ended span-
ner is required to turn the two catches at the top
and bottom of the door.
6. The secondary burners are
removed by lifting them verti-
cally up and out.
UK

15
8. The thin side pieces of
the back plate are removed
by removing the locking
brackets at the top. This is
done by pushing the brack-
et upwards.
9.The back plate can now
be removed and the inter-
nal cover plate dismounted.
7. If the ceramic logs are
fitted, remove these.
10. The internal cover plate
is now fitted to the un-
derside of the top plate as
shown. It is vital that this
plate fits and seals correctly
11 Fit the connecting piec-
es where the cover plates
were and replace the back
plate, logs and burners.
UK
The side pieces can then be
removed.

16
LPG
LPG LNG
LNG
Conversion to bottled gas (LPG)
The stove is supplied configured for natural gas but can be converted to
bottled gas (LPG). The conversion must only be carried out by a Gas Safe
Registered engineer.
Conversion kit. Use article number 3713595. This set contains 4 new
injectors suitable for propane/LPG gas.
The injectors for the secondary
burners for LPG are marked
"100"
The injectors for the second-
ary burners for natural gas are
marked "260"
UK

17
LPGLNG
LPGLNG
The injector for the pilot light for
LPG is marked "27"
The injector for the pilot light for
natural gas is marked "32"
The injector for the main burner for LPG
is marked "80"
The injector for the main burner for nat-
ural gas is marked "120"
UK

18
The gas unit needs to be dismantled to gain access to the injectors. Do
this in the following manner:
Lift the perforated plate up and out of
the stove.
Loosen the four screws holding the
gas unit in place.
UK
Remove the reflector plate

19
Replace the two injectors for the second-
ary burners by loosening the coupling and
carefully pulling the pipe out. Loosen the
locknut and then unscrew the injector. Fit
the LPG injector and tighten the lock nut.
Finally, re-tighten the coupling.
Once the gas unit has been dismounted, replace the four injectors and
adjust the three air intakes.
Now the gas unit can be lifted out carefully
by tilting and rotating the unit a little.
UK

20
Remove the injector for the main burner by
loosening the coupling and carefully pulling
the pipe out and then unscrewing the injec-
tor. Fit the LPG injector and tighten the lock
nut. Finally, re-tighten the coupling.
Replace the injector for the pilot light by
loosening the coupling and carefully pull-
ing the pipe out. Note. The small pilot light
injector should now fall out and can be
replaced with the LPG injector.
UK
Other manuals for NEXO Series
1
This manual suits for next models
20
Table of contents
Other RAIS/attika Stove manuals
Popular Stove manuals by other brands

COSDEP
COSDEP STQ14 User and maintenance manual

Rayburn
Rayburn Heatranger 440 Servicing instructions

Extraflame
Extraflame Vicenza V3.4 Installation and operating instructions

Westfire
Westfire WF35 Installation manual and operating instructions

Saey
Saey 200+ series operating instructions

Quadra-Fire
Quadra-Fire CASTILE-B series owner's manual