2.1 Positioning
Generally Sara should be installed in a centrally located
position within the home. When deciding where to
position the appliance, you must consider the following:
1. The place of installation of the pellet fire must
comply with local and national regulations. The
pellet fire must be fuelled only with quality pellets
manufactured to standard AS/NZS4014.6. The
pellet fire cannot operate using traditional fire wood.
2. Do not install a pellet fire in a bedroom or room
where people sleep.
3. Sara has a convection fan which blows air through
tubes in the direction the fire faces. For optimum
performance and heat circulation, locate the pellet
fire in a large and open room that is centrally located
in the house.
4. The fire requires a 230 volt power supply and comes
with a 2m plug in power lead. There must be easy
access to the socket so the fire can be isolated
from the power if required . If the cable supplied is
not long enough to reach the nearest outlet, use a
suitable 3 pin extension cord. A surge protector is
recommended for use with all Ecoteck pellet fires.
2.2 Installing
Installation of the Ecoteck Sara Wood Pellet Fire must
be undertaken by an approved installer, who must
then give the purchaser a declaration of conformity of
the appliance, and will assume all responsibility for the
final installation and consequent correct function of the
installed product.
Please read this Manual thoroughly before commencing
installation as failure to follow the instruction could cause
damage to the pellet fire or property. It is also necessary
for the registered installer to take into consideration
all the laws and national, regional, provincial and local
regulations present in the country in which the appliance
hasbeeninstalled. Intheeventoffailuretorespectthese
precautions, Nature’s Flame declines all responsibility.
1. The fire must be installed on a floor with sufficient
carrying capacity. If the existing building does not
meet this requirement, appropriate measures must
be taken (i.e. a load distribution plate).
2. Sara must be installed on a non-combustible
surface. This surface must protrude a minimum
of 150mm from the front of the closed pellet fire
door and a minimum of 200mm from the side of the
appliance. Please note that if a floating hearth is to
be installed, an allowance must be made below the
fire for installation of the chosen surround.
3. Check clearances to combustibles (see “5. Creating
the Cavity” on page 4) to ensure sufficent space
is created in the cavity, and that the position of
structural elements near the proposed flue have
adequate clearance.
4. Check clearance for service – as the Sara is
designed to be pulled out, as long as there is front
access, this should be sufficient.
5. Check there is sufficient ventilation for combustion
air and this is unaffected by mechanical extraction.
An external air intake may be required. (see
“5. Creating the Cavity” on page 4 for cavity
ventilation requirements).
6. There must be sufficient circulation of air in the room
where the pellet fire is installed. Never open the
door of the pellet fire while it is functioning.
7. Check there is a suitable flue location (studs, joists,
rafters etc).
8. Sara has been Safety Tested to AS/NZS 2918
using the Davins manufactured flue, Test Report
ARS 05/1185. Installation is not exclusive to these
nominated kits, though an alternative flue should
only be considered following consultation with your
local council.
9. Because of the positive pressure in the flue, sealing
of al 75mm stainless joints is mandtory - use high
temperature Maniseal. Both inner and outer flue
This manual is designed for the technician/installer.
Please read this entire manual before operating your
Ecoteck Wood Pellet Fire. Failure to follow these
instructions may result in poor performance, damage to
the fire, property damage, bodily injury or even death.
Any unauthorised modification of the appliance or use
of replacement parts not supplied by the manufacturer
is prohibited.
All national and local regulations shall be complied with
when installing this appliance. Your local Nature’s Flame
dealer will be happy to assist you in obtaining information
with regards to your local building codes and installation
regulations.
1. Introduction
2. Positioning and Installation of the wood pellet fire