manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Ravenheat
  6. •
  7. Boiler
  8. •
  9. Ravenheat CSI PRIMARY AAA User manual

Ravenheat CSI PRIMARY AAA User manual

Other Ravenheat Boiler manuals

Ravenheat White Boiler WH 80 Operating manual

Ravenheat

Ravenheat White Boiler WH 80 Operating manual

Ravenheat CSI85A(T) User guide

Ravenheat

Ravenheat CSI85A(T) User guide

Ravenheat HE 25 S COMPACT Operating manual

Ravenheat

Ravenheat HE 25 S COMPACT Operating manual

Ravenheat Flue Boiler User guide

Ravenheat

Ravenheat Flue Boiler User guide

Ravenheat CSI 85 B User manual

Ravenheat

Ravenheat CSI 85 B User manual

Ravenheat CSI 123(T) Low Nox User manual

Ravenheat

Ravenheat CSI 123(T) Low Nox User manual

Ravenheat Little Star LS 80 User manual

Ravenheat

Ravenheat Little Star LS 80 User manual

Ravenheat CS 80 T Operating manual

Ravenheat

Ravenheat CS 80 T Operating manual

Ravenheat CSI 85 User guide

Ravenheat

Ravenheat CSI 85 User guide

Ravenheat Little Star LS 80 User guide

Ravenheat

Ravenheat Little Star LS 80 User guide

Ravenheat HE Primary AAA Operating manual

Ravenheat

Ravenheat HE Primary AAA Operating manual

Ravenheat CS 80 Operating manual

Ravenheat

Ravenheat CS 80 Operating manual

Ravenheat HE 120N Technical manual

Ravenheat

Ravenheat HE 120N Technical manual

Ravenheat RSF 82ET User manual

Ravenheat

Ravenheat RSF 82ET User manual

Ravenheat RSF820/20T Datasheet

Ravenheat

Ravenheat RSF820/20T Datasheet

Ravenheat HE 85 A User guide

Ravenheat

Ravenheat HE 85 A User guide

Ravenheat RSF 84E User guide

Ravenheat

Ravenheat RSF 84E User guide

Ravenheat CSI SYSTEM AAA T 780 Series User manual

Ravenheat

Ravenheat CSI SYSTEM AAA T 780 Series User manual

Ravenheat RSF 82E User guide

Ravenheat

Ravenheat RSF 82E User guide

Ravenheat RSF 84ET User manual

Ravenheat

Ravenheat RSF 84ET User manual

Ravenheat CSI 120 User manual

Ravenheat

Ravenheat CSI 120 User manual

Ravenheat HE 25 C COMPACT Operating manual

Ravenheat

Ravenheat HE 25 C COMPACT Operating manual

Ravenheat 780 Series Operating manual

Ravenheat

Ravenheat 780 Series Operating manual

Ravenheat HE 80 S Operating manual

Ravenheat

Ravenheat HE 80 S Operating manual

Popular Boiler manuals by other brands

IDEAL IMAX XTRA EL 320 user guide

IDEAL

IDEAL IMAX XTRA EL 320 user guide

UTICA BOILERS BC3D Installation, operation & maintenance manual

UTICA BOILERS

UTICA BOILERS BC3D Installation, operation & maintenance manual

Lochinvar SOLUTION 260000 Installation & service manual

Lochinvar

Lochinvar SOLUTION 260000 Installation & service manual

Weil-McLain EG 6 Series manual

Weil-McLain

Weil-McLain EG 6 Series manual

RBI LCD Series Installation & operation manual

RBI

RBI LCD Series Installation & operation manual

Baxi MainEco Combi 28 Installation and service manual

Baxi

Baxi MainEco Combi 28 Installation and service manual

Unical ALKON R 24 Installation and Servicing Manual

Unical

Unical ALKON R 24 Installation and Servicing Manual

Automatic Heating Gasogen Installation and Servicing Manual

Automatic Heating

Automatic Heating Gasogen Installation and Servicing Manual

Viessmann VITORADIAL 300-T Type VR3 Service instructions for contractors

Viessmann

Viessmann VITORADIAL 300-T Type VR3 Service instructions for contractors

Alpha GasSaver GS-1 Installation and servicing instructions

Alpha

Alpha GasSaver GS-1 Installation and servicing instructions

Baxi ROCA LAURA PLUS 28/28 Operating, cleaning and maintenance instructions for the user

Baxi

Baxi ROCA LAURA PLUS 28/28 Operating, cleaning and maintenance instructions for the user

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Vaillant

Vaillant uniSTOR VIH SW GB 500 BES operating instructions

Kärcher HWE 4000 Gas manual

Kärcher

Kärcher HWE 4000 Gas manual

Radijator BIO max 23.1 instruction manual

Radijator

Radijator BIO max 23.1 instruction manual

Granby BKC Installation, operation and maintenance manual

Granby

Granby BKC Installation, operation and maintenance manual

Brunner BSV 20 Instructions for use

Brunner

Brunner BSV 20 Instructions for use

Potterton 50e Installation and Servicing Manual

Potterton

Potterton 50e Installation and Servicing Manual

UTICA BOILERS TriFire Assembly instructions

UTICA BOILERS

UTICA BOILERS TriFire Assembly instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

ESCAPE OF GAS
Should a gas leak be suspected, contact your gas
supplier without delay.
Do NOT search for gas leaks with a naked flame.
WARNING: This appliance must be earthed. Do not
touch or tamper with this sealed unit or its
components.
1INTRODUCTION
1.1 Please carefully read information given in the
booklet to help you again maximum control from
your appliance with minimum trouble and cost.
1.1.1 Your Ravenheat Condensing Boiler has been
designed to supply your Central Heating
reqirements.
PLEASE NOTE
Due to the high efficiency and resulting low flue
gas exhaust temperature a white plume of
condensation vapour (cool steam) will be emitted
from the flue outlet terminal, this is quite normal.
It will be particularly evident during periods of low
outdoor temparatureor when the boiler is
working at its optimum performance.
1.2 CLEARANCES AROUND THE BOILER
Above 125 mm ( 5 inches)
Below 150 mm ( 6 inches)
Front 450 mm (18 inches)
Sides 5 mm (0.2 inches)
25mm (1inch) in front when installed in a
cupboard.
1.2.1 Minimum clearences are required for safety and
maintenance. Do NOT obstruct any purpose
made ventilation opening if boiler has been
fitted in a compartment.
Never hang clothes,ect, over the appliance
1.3 USER CONTROLS (Fig.1)
1.3.1 This appliance is designed to operate with the
minimum of attention by the User. All the controls
are to be found on the control pannel.
1.4 OPERATING SAFETY CHECKS TO PROTECT
YOUR APPLIANCE
1.4.1 Before lighting theAppliance check that the
Central Heating system is charged with water
within the system.
If it is a pressurised system, check that the bar
gauge is not below 1.
1.4.2 ARED warning light on the control panel warns
of a flame failure of the burner. This can be reset
pressing on/ off switc.
1.4.3 ARED warning intermittance light on the control
panel warms of a high temperature lockout on
the overheat thermostat. This could occur due to
air or poor circulation in the boiler.
This can be reset manually by pressing on/
off switch. If lockout should persist leave the
applliance shut down and consult your installer/
service engineer immediatly.
1.4.4. The CSI Primary condensing boiler is fitted with
a condensate outlet whitch must be connected
by the installer to a suitable discharge point
as specified in the installation manual. On no
account should this discharge pipe be blocked or
modified.
USER’S GUIDE
CSI PRIMARY AAA
CONDENSING PRIMARY INNOVATION SUPER HIGH EFFICIENTY AUTOMATIC
MODULATING BOILER FOR CENTRAL HEATING AND DOMESTIC HOT WATER
It is the law that all gas appliances are installed by
a competent person, in accordance with the gas
safety installation and use current regulations.
To the current Gas Safety (Installation and Use)
Regulations B.S.5440:2-(2000).
All CORGI registered installers carry a CORGI ID card and
have a registration number. Both should be recorded in your
boiler Log book. You can check your installer by calling
CORGI direct on 01256 732300.
1
3.5 TO SHUT DOWN THEAPPLIANCE
3.5.1 For long periods, switch on/off switch to off.
For long periods switch of the on/off switch.
If the appliance is to be shut down for long
periods when there is a risk of freezing, then
appliance should be drained . Similar refilling
must be done by a competent person
following approved procedure.
4 CLEANING OF APPLIANCE OUTER
CASING
4.1 Use a clean damp cloth. Do not use any
abrasive cleaners and with a dry cloth lightly
polish to protect painted surfaces.
Control Panel and fixiture can be wiped with
damp cloth and dried . Spray polishes must
not be used on control panel surfaces or
switches. Care must be taken in preventing
any liquids entering the appliance.
5 CARE OF YOUR APPLIANCE AND
SYSTEM
5.1 Annual servicing of your appliance is required
to maintain safety and efficiency of its
operation. Therefore it is reccommended that
the appliance is serviced at least once a year
and that the whole of the Heating System be
checked at the same time by a qualified
installer. If it is know or suspected that
a fault exists on the boiler then it MUST NOT
be used untill the fault has been corrected by
a COMPETENT PERSON. It is essential that
the Instructions in this booklet are strictly
followe for safe and economic operation of the
boiler.
SERVICING SHOULD BE CARRIED OUT
BY A QUALIFIED INSTALLER.
Ravenheat Manufacturing Ltd
Chartists Way , Morley , Leeds
LS 27 9ET.
2 OPERATING DOMESTIC HOT WATER
2.1 Temperature of domestic hot water can be
varied by djusting the water.
Thermostat will control maximum temperature
leaving the appliance.
The knob can be set between minimum and
maximum appoximately 40° to 85°.
For min./ max temperature of domestic hot
water it may be necessary to set external
thermostat.
3 OPERATING HEATING AND HOT WATER
3.1 Push on/ off switch in on position.
3.3 Switch on timeclock, adjust room stat and/or
thermostatic radiator valves to high settings in
case they are connected.
3.3 Burner will operate, temparature output of
Central Heating can be adjusted by Central
Heating Control Knob. The Knob can be set
between minimum (40°C) and Maximum
(85°C).
Adjust external controls required settings.
The optimum thetmostat setting (condensing
mode) is when the thermostat are set between
60/65°. The optimum thermostat setting for
condensating heatin mode is marked by a
line on the thermostat heating panel. However,
consideration will need to be given to
temperatures of heat required for radiators to
give adequate, comfortable room temperatures.
The overrun thermostat will keep the pump
running when the boiler shuts down, so long
as the temperature within the boiler is above a
predetermined level.
3.4 TO SHUT DOWN THEAPPLIANCE
3.4.1 For long periods, switch on/off switch to off.
For long periods switch of the on/off switch.
If the appliance is to be shut down for long
periods when there is a risk of freezing, then
appliance should be drained . Similar refilling
must be done by a competent person following
approved procedure.
2
Fig. 1
3
COD. 0017FOG06015/2 - 03/2009
Chartists Way, Morley, Leeds, LS27 9ET
Telephone : 0044(0)113 252 7007
Tfax : 0044(0)113 238 0229
Website : www.ravenheat.co.uk
E-mail : [email protected]
Ravenheat reserves the right to make changes and
improvements in our products which may affect the accuracy
of the information contained in this leaflet.