Important Information
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT
REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER TO QUALIFIED SERVICE PERSONNEL.
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning ash with arrowhead symbol. within
an equilateral triangle, is intended to alert the
user to the presence of uninsulated “dangerous
voltage”within the product’s enclosure that may
be of sucient magnitude to constitute a risk of
electric shock to persons.
The exclamation point within an equilateral trian-
gle is intended to alert the user to the presence of
important operating and maintenance (servicing)
instructions in the literature accompanying the
appliance.
Please ll out the product registration card (packed separately) and return it
immediately. For US customers: Your RCA Commercial Electronics product
may also be registered at http://service.rcacommercialtv.com. Registering
this product allows us to contact you if needed.
Keep your sales receipt to obtain warranty parts and service and for proof
of purchase. Attach it here and record the serial and model numbers in case
you need them. These numbers are located on the product.
TO PREVENT FIRE OR
SHOCK HAZARDS, DO NOT
EXPOSE THIS PRODUCT TO
RAIN OR MOISTURE.
This reminder is provided to call the CATV system installer’s attention to
Article 820-40 of the National Electric Code (U.S.A.). The code provides
guidelines for proper grounding and, in particular, species that the cable
ground shall be connected to the grounding system of the building, as
close to the point of the cable entry as practical.
When grounding of the assessable metal parts is required, a separate
grounding lead is to be used.
Product Information
WARNING
CAUTION
NOTE TO CABLE TV INSTALLER
GROUNDING
Product Registration
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO ALL LOCAL
CODES. READ AND FOLLOW THE SAFETY INSTRUCTIONS BEFORE ATTEMPTING THIS INSTALLATION
Model No.
Serial No.
Purchase Date:
Dealer/Address/Phone:

3
Minimum Installation Requirements
Minimum Requirements
• Input Voltage: 100 ~ 120VAC ~ 60Hz, 48 W
• Output Voltage: 24 ± 0.5VDC / 2A.
• Standby power consumption: ≤0.5 W
• DC ripple: 100mV (P-P)
• Ambient Temperature: -10 ~ + 50 °c
• Large, full metal casing provides excellent heat dissipation to protect the electrical power
components.
• Overload and output short circuit protection
• Frequency bandwidth: 5 ~ 1000MHz
• Throughput loss: ≤0.5 dB
• Band atness: ± 0.5dB
• Return loss: ≥ 13dB
• Input / Output impedance: 75 Ω
ADDITIONAL NOTES:
Contact RCA Commercial for a complete list of compatible arm models that can be used with
this wall bracket power supply.
The JPS24D is an ecient switching power supply that provides DC24V / 1 A supply output
combined with the TV input signal on a COAX output. This product is used in hospitals, hotels,
RVs, boats, and other television signal transmission systems incorporating the RCA J14HV840
television designed to be powered over the COAX cable.
At the time of this printing, these congurations have been evaluated and tested by Under-
writers Laboratories. Other means of mounting may be potentially hazardous.
ARM MODEL NOTES:
SPECIFICATIONS
Overview & Cleaning
CLEANING : Clean the exterior of this mount by removing dust with a lint-free cloth. For further cleaning,
use a soft cloth or paper towel dampened with water.
CAUTION : To avoid damage to the surface of the mount, do not use abrasive or chemical cleaning agents.
DISINFECTING : Do not immerse this mount, rather clean with a soft damp cloth. To avoid damage to the
surface of the mount, test a small portion of the mount’s cabinet with any new disinfectant to verify that the
disinfectant will not discolor or soften the enclosure.
This apparatus with class I construction shall be connected to a main socket outlet with a protective earthing
connection.
CLEANING & DISINFECTION:

Mount Installation Instructions
4Mount Installation
GUIDELINES
1. LOCATION – Make certain that the CATV jack is near
enough to the wall bracket so the “RF IN” cable can
be connected to it. Also position the wall bracket near
an AC wall outlet at a mounting height of 47±2 inches.
See Figure 1.
2. WALL STRENGTH – These wall bracket mounting
instructions installation directly into concrete walls.
IN ALL CASES the wall construction must be able
to support a minimum loading of 350 PSI applied
perpendicular to the mounting hole locations by
compression or tension. Some wall construction may
require internal bracing to accept the minimum loading
required.
3. HARDWARE REQUIREMENTS – Mounting fasteners
are NOT supplied with the wall bracket.
4. TOTAL MAXIMUM WEIGHT of the TV receiver and
support arm system cannot exceed 41 lbs.
1. All threaded rods, bolts or machine screws
will be ¼”-20UNC-2A thread or equivalent.
2. All threaded rods will be nished off with an
acorn nut
30”
Minimum
Clearance
Mounting Height
Figure 1.
Mounting Hole Pattern
COMMON WALL
47 ± 2”
4 ”
8” 10”
6 ”
1 ⁄2
3 ⁄8

5
Direct Wall Mounting
Direct Wall Mounting
It is the responsibility of the architect and/or structural engineer in charge of the project to
ensure the strength of the wall where the TV arm and mounting bracket will be installed.
It is the responsibility of the architect and/or structural engineer in charge of the project to
ensure the correct hardware is used to attach the wall mount to the wall.
SOLID CONSTRUCTION WALLS
1. Locate a mounting position near an antenna CATV jack and AC Wall outlet. Mounting height should be
47” from the oor to top of pivot hole as shown in gure 1. It is also important that the mounting location
be within 15” of the side of the patient’s bed. Please note also that the suspension arm requires a min-
imum clearance distance of 30” from ceiling to the top of the wall bracket. A check with the contractor/
architect or Facility Engineering Department regarding hidden objects behind the wall should be made
before proceeding with this installation and nal operation of the arm assembly.
2. Level the wall mount pivot hole and mark the location of the mounting holes.
3. Follow the instructions supplied with the cement expansion anchors and ensure the anchors are
installed properly on the marks. Attach wall mount to cement expansion anchors following instructions
supplied with the anchors.
In concrete, brick, and some types of cement block, cement expansion anchors can be used.
Follow the instructions supplied with the cement expansion anchors to ensure proper
installation.

Power Supply Installation Instructions
6Power Supply Install
Refer to gure 6.
TO AC OUTLET MATV SIGNAL
OPERATION & SAFETY INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS
1. Attach coaxial cable from ARM to “F” Fitting
marked “RF/DC OUT”. Wrench tighten.
2. Attach coaxial cable from Master Antenna TV
System to “F” tting marked “RF IN”. Wrench
tighten.
3. Plug in line cord to 120 VAC outlet.
Save these instructions for future reference. Unplug
this unit from the wall outlet before cleaning. Do not
use liquid cleaners or aerosol cleaners. Use a damp
cloth for cleaning. This unit does not require periodic
maintenance other than cleaning.
Figure 6.
WARNING: TO REDUCE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE THIS
POWER SUPPLY TO RAIN OR MOISTURE.
CAUTION: TO REDUCE THE RISK OF
ELECTRIC SHOCK, DO NOT REMOVE
COVER. NO USER SERVICEABLE PARTS
INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.
CAUTION: MAIN PLUG OF THE POWER SUPPLY UNIT IS THE METHOD OF DISCONNECTING
POWER. THE PLUG MUST REMAIN READILY ASSESSABLE.
CAUTION: ASSESSABLE METAL PARTS OF THIS APPARATUS ARE ELECTRICALLY
ISOLATED FROM THE GROUNDING CONDUCTOR OF THE SUPPLY CORD. WHEN
GROUNDING OF THE ASSESSABLE METAL PARTS IS REQUIRED, A SEPARATE GROUNDING
LEAD IS TO BE USED.
CAUTION: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS
APPARATUS TO DRIPPING OR SPLASHING. DO NOT PLACE OBJECTS FILLED WITH
LIQUIDS, SUCH AS VASES, ON THE APPARATUS.
THIS SUPPLY IS FOR USE ONLY WITH
UL LISTED TV RECEIVERS MARKED
TO INDICATE USE WITH THIS POWER
SUPPLY.
WARNING: TO PREVENT INJURY, THIS APPARATUS MUST BE SECURELY ATTACHED TO
THE FLOOR/WALL IN ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS.

7
Chapter X: Information
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions
5. Do not use this apparatus near water.
6. Clean only with dry cloth.
7. Do not block any ventilation openings. Install
in accordance with the manufacturer’s
instructions.
8. Do not install near any heat sources such
as radiators, heat registers, stoves, or other
apparatus (including ampliers) that produce
heat.
9. Do not defeat the safety purpose of the
polarized or grounding-type plug. A polarized
plug has two blades with one wider than the
other. A grounding type plug has two blades
and a third grounding prong. The wide blade
or the third prong is provided for your safety.
If the provided plug does not t into your
outlet, consult an electrician for replacement
of the obsolete outlet.
10. Protect the power cord from being walked on
or pinched particularly at plugs, convenience
receptacles, and the point where they exit
from the apparatus.
11. Only use attachments/accessories specied
by the manufacturer.
12. Use only with the cart, stand, tripod,
bracket, or table specied by the
manufacturer, or sold with the
apparatus. When a cart is used,
use caution when moving the cart/apparatus
combination to avoid injury from tip-over.
IMPORTANT SAFETY INSTRUCTIONS
Read before operating equipment
13. Unplug this apparatus during lightning storms or
when unused for long periods of time.
14. Refer all servicing to qualied service personnel.
Servicing is required when the apparatus has
been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been
spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or
moisture, does not operate normally, or has
been dropped.
15. If an outside antenna or cable system is
connected to the product, be sure the antenna
or cable system is grounded so as to provide
some protection against voltage surges and
built-up static charges. Section 810 of the
National Electrical Code, ANSI/NFPA No. 70-
1984 (Section 54 of Canadian Electrical Code,
Part 1) provides information with respect to
proper grounding of the mast and supporting
structure, grounding of the lead-in wire to an
antenna-discharge unit, size of grounding
conductors, location of antenna-discharge
unit, connection to grounding electrodes, and
requirements for the grounding electrode. See
following example.
7

Visit the RCA website at http://www.rcacommercialtv.com
DTI Services, LLC
5350 Lakeview Parkway Dr. South
Indianapolis, IN 46268
1-800-722-2161
DTI
Please do not send any products to the Indianapolis address listed in this manual or on the
carton. This will only add delays in service for your product.
Table of contents
Popular Power Supply manuals by other brands

ECTIVE
ECTIVE AccuBox operating instructions

American Magnetics
American Magnetics 05100PS-430-601 Installation, operation and maintenance instructions

Good Will Instrument
Good Will Instrument PSS-3203 user manual

Pepperl+Fuchs
Pepperl+Fuchs HiC2027 Series manual

Lowell power
Lowell power UPS9LI-1500 user manual

Akyga
Akyga AK-EV-06 user manual